{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T10:05:34Z","timestamp":1780481134210,"version":"3.54.1"},"reference-count":17,"publisher":"Oxford University Press (OUP)","issue":"9","license":[{"start":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T00:00:00Z","timestamp":1780272000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/pages\/standard-publication-reuse-rights"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,6,3]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Computed tomography (CT) is an imaging technique commonly used in Radiation Oncology clinics. Accurately determining the specific stochastic risks associated with low-dose ionizing radiation is challenging, so estimating the radiation dose is sometimes necessary. Various computer codes have been employed for this purpose, including the National Cancer Institute dosimetry system (NCICT) used in this study. The NCICT code combines International Commission on Radiation Protection reference pediatric and adult voxel phantoms with Monte Carlo simulation of the reference CT scanner to calculate organ doses for CT patients. This study aimed to investigate the effect of body mass index (BMI) on organ dose and effective dose. The doses received by certain organs were calculated using the NCICT code by varying the mass of a male phantom while keeping the height constant. As a result, changes in doses to the lung, kidney, liver, spinal cord, and the effective dose with respect to BMI were analyzed. It was found that the doses to the lung, kidney, liver, spinal cord, and the overall effective dose decreased as BMI increased.<\/jats:p>","DOI":"10.1093\/rpd\/ncaf183","type":"journal-article","created":{"date-parts":[[2025,12,18]],"date-time":"2025-12-18T12:58:30Z","timestamp":1766062710000},"page":"689-694","source":"Crossref","is-referenced-by-count":0,"title":["Investigation of the effect of patient body mass index on radiation doses in computed tomography imaging"],"prefix":"10.1093","volume":"202","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8648-5050","authenticated-orcid":false,"given":"Hande","family":"\u00dcnal","sequence":"first","affiliation":[{"name":"Science Faculty, Physics Department , Akdeniz University, Antalya, Turkiye"},{"name":"Medicine Faculty, Radiation Oncology , Akdeniz University, Antalya, Turkiye"},{"name":"Vocational School of Health Sciences, Radiaotherapy , Akdeniz University, Antalya Turkiye"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9788-699X","authenticated-orcid":false,"given":"Ismail H","family":"Sarp\u00fcn","sequence":"additional","affiliation":[{"name":"Science Faculty, Physics Department , Akdeniz University, Antalya, Turkiye"},{"name":"Medicine Faculty, Radiation Oncology , Akdeniz University, Antalya, Turkiye"},{"name":"Nuclear Sciences Research and Application Centre , Akdeniz University, Antalya, Turkiye"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Timur","family":"Koca","sequence":"additional","affiliation":[{"name":"Medicine Faculty, Radiation Oncology, Akdeniz University , Antalya, Turkiye"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"B\u00fc\u015fra","family":"Y\u0131lmazer","sequence":"additional","affiliation":[{"name":"Medicine Faculty, Radiation Oncology, Akdeniz University , Antalya, Turkiye"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2026,6,3]]},"reference":[{"key":"2026060305103187900_ref1","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1148\/radiol.2511081686","article-title":"Risks associated with low doses and low dose rates of ionizing radiation: why linearity may be (almost) the best we can do","volume":"251","author":"Little","year":"2009","journal-title":"Radiology"},{"key":"2026060305103187900_ref2","first-page":"1","article-title":"The 2007 recommendations of the international commission on radiological protection, ICRP publication 103","volume":"37","author":"ICRP","year":"2007","journal-title":"Ann ICRP"},{"key":"2026060305103187900_ref3","doi-asserted-by":"crossref","first-page":"362","DOI":"10.1259\/bjr\/01948454","article-title":"Cancer risks from diagnostic radiology","volume":"81","author":"Hall","year":"2008","journal-title":"Br J Radiol"},{"key":"2026060305103187900_ref4","first-page":"1","article-title":"International commission on radiological protection: managing patient dose from multi detector computed tomography (MDCT)","volume":"37","author":"Valentin","year":"2007","journal-title":"ICRP Publication 102"},{"key":"2026060305103187900_ref5","article-title":"Recommendations of the international commission on radiological protection, ICRP publication 26","volume":"1","author":"ICRP","year":"1977","journal-title":"Ann"},{"key":"2026060305103187900_ref6","doi-asserted-by":"crossref","first-page":"828","DOI":"10.1118\/1.598948","article-title":"Calculation of effective dose","volume":"27","author":"McCollough","year":"2000","journal-title":"Med Phys"},{"key":"2026060305103187900_ref7","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1093\/rpd\/ncr333","article-title":"Development of a web-based CT dose calculator: WAZA-ARI","volume":"147","author":"Yoshitake","year":"2011","journal-title":"Radiat Prot Dosim"},{"key":"2026060305103187900_ref8","doi-asserted-by":"crossref","first-page":"555","DOI":"10.1007\/s003300050709","article-title":"A PC program for estimating organ dose and effective dose values in computed tomography","volume":"9","author":"Kalender","year":"1999","journal-title":"Eur Radiol"},{"key":"2026060305103187900_ref9","doi-asserted-by":"crossref","first-page":"072104.","DOI":"10.1118\/1.4883778","article-title":"Patient-based estimation of organ dose for a population of 58 adult patients across 13 protocol categories","volume":"41","author":"Sahbaee","year":"2014","journal-title":"Med Phys"},{"key":"2026060305103187900_ref10","doi-asserted-by":"crossref","first-page":"891","DOI":"10.1088\/0952-4746\/35\/4\/891","article-title":"NCICT: a computational solution to estimate organ doses for pediatric and adult patients undergoing CT scans","volume":"35","author":"Lee","year":"2015","journal-title":"J Radiol Prot"},{"key":"2026060305103187900_ref11","doi-asserted-by":"publisher","first-page":"e0217816","DOI":"10.1371\/journal.pone.0217816","article-title":"How have advances in CT dosimetry software impacted estimates of CT radiation dose and cancer incidence? A comparison of CT dosimetry software: implications for past and future research","volume":"14","author":"Maxwell","year":"2019","journal-title":"PLoS One"},{"key":"2026060305103187900_ref12","doi-asserted-by":"publisher","first-page":"14","DOI":"10.1186\/s41747-019-0130-5","article-title":"Patient organ and effective dose estimation in CT: comparison of four software applications","volume":"4","author":"De Mattia","year":"2020","journal-title":"Eur Radiol Exp"},{"key":"2026060305103187900_ref13","doi-asserted-by":"publisher","first-page":"e214","DOI":"10.1016\/j.radi.2020.02.011","article-title":"A comparison of the CT-dosimetry software packages based on stylized and boundary representation phantoms","volume":"26","author":"Saeed","year":"2020","journal-title":"Radiography (Lond)"},{"key":"2026060305103187900_ref14","doi-asserted-by":"crossref","first-page":"615","DOI":"10.1118\/1.3368596","article-title":"The feasibility of a scanner-independent technique to estimate organ dose from MDCT scans: using CTDIvol to account for differences between scanners","volume":"37","author":"Turner","year":"2010","journal-title":"Med Phys"},{"key":"2026060305103187900_ref15","first-page":"1","article-title":"Size-specific dose estimates (SSDE) in pediatric and adult body CT examinations","volume":"204","author":"Boone","year":"2011","journal-title":"AAPM Report"},{"key":"2026060305103187900_ref16","doi-asserted-by":"crossref","DOI":"10.1007\/978-3-662-05379-9","volume-title":"Multislice CT","author":"Reiser","year":"2004"},{"key":"2026060305103187900_ref17","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1088\/0952-4746\/34\/2\/363","article-title":"Database of normalised computed tomography dose index for retrospective CT dosimetry","volume":"34","author":"Lee","year":"2014","journal-title":"J Radiol Protect"}],"container-title":["Radiation Protection Dosimetry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/rpd\/article-pdf\/202\/9\/689\/68458632\/ncaf183.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/rpd\/article-pdf\/202\/9\/689\/68458632\/ncaf183.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T09:10:42Z","timestamp":1780477842000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/rpd\/article\/202\/9\/689\/8700438"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6]]},"references-count":17,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2026,6,3]]},"published-print":{"date-parts":[[2026,6,3]]}},"URL":"https:\/\/doi.org\/10.1093\/rpd\/ncaf183","relation":{},"ISSN":["0144-8420","1742-3406"],"issn-type":[{"value":"0144-8420","type":"print"},{"value":"1742-3406","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2026,6]]},"published":{"date-parts":[[2026,6]]}}}