{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,13]],"date-time":"2026-03-13T08:51:16Z","timestamp":1773391876241,"version":"3.50.1"},"reference-count":12,"publisher":"Oxford University Press (OUP)","issue":"3\u20134","license":[{"start":{"date-parts":[[2026,3,1]],"date-time":"2026-03-01T00:00:00Z","timestamp":1772323200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/pages\/standard-publication-reuse-rights"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,3,13]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Optimizing radiation dose while maintaining image quality remains a key challenge in computed tomography (CT). This study used a thorax-specific anthropomorphic phantom to assess patient dose, image quality, and artefact presence under automated tube current modulation settings and to evaluate the effect of tube voltage on Hounsfield Unit (HU) response for different iodine concentrations. Dose metrics, noise levels, and image quality indicators were extracted from Digital Imaging and Communications in Medicine (DICOM) metadata and image analysis. The study examined how patient positioning affects modulation performance and how tube voltage influences HU values in iodinated inserts. Results revealed inconsistencies in dose modulation across CT systems and highlighted the importance of synchronized protocols. A methodology was proposed to harmonize scanning protocols, ensuring consistent image quality and improved patient safety. These findings demonstrate the value of anthropomorphic phantoms in validating and optimizing CT protocols across clinical environments.<\/jats:p>","DOI":"10.1093\/rpd\/ncaf192","type":"journal-article","created":{"date-parts":[[2025,12,23]],"date-time":"2025-12-23T12:48:56Z","timestamp":1766494136000},"page":"319-325","source":"Crossref","is-referenced-by-count":0,"title":["Utilization of a thorax anthropomorphic phantom for dose assessment and scanning protocol synchronization in computed tomography"],"prefix":"10.1093","volume":"202","author":[{"given":"Adnan","family":"Beganovi\u0107","sequence":"first","affiliation":[{"name":"Department of Radiation Protection and Medical Physics, Clinical Center of the University of Sarajevo , Bolni\u010dka 25, Sarajevo 71000,","place":["Bosnia and Herzegovina"]},{"name":"Department of Physics, Faculty of Science, University of Sarajevo , Zmaja od Bosne 33\u201335, Sarajevo 71000,","place":["Bosnia and Herzegovina"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tarik","family":"Seferovi\u0107","sequence":"additional","affiliation":[{"name":"Faculty of Health Studies, University of Sarajevo , Bardak\u010dije 1, Sarajevo 71000,","place":["Bosnia and Herzegovina"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mahira","family":"Red\u017ei\u0107","sequence":"additional","affiliation":[{"name":"Department of Radiation Protection and Medical Physics, Clinical Center of the University of Sarajevo , Bolni\u010dka 25, Sarajevo 71000,","place":["Bosnia and Herzegovina"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Amra","family":"Skopljak-Beganovi\u0107","sequence":"additional","affiliation":[{"name":"Department of Radiation Protection and Medical Physics, Clinical Center of the University of Sarajevo , Bolni\u010dka 25, Sarajevo 71000,","place":["Bosnia and Herzegovina"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Melika","family":"Damad\u017ei\u0107","sequence":"additional","affiliation":[{"name":"Department of Medical Physics and Radiation Protection, University Clinical Center of Tuzla , Trnovac bb, Tuzla 75000,","place":["Bosnia and Herzegovina"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fuad","family":"Zuki\u0107","sequence":"additional","affiliation":[{"name":"Clinic of Radiology, Clinical Center of the University of Sarajevo , Bolni\u010dka 25, Sarajevo 71000,","place":["Bosnia and Herzegovina"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sabina","family":"Prevljak","sequence":"additional","affiliation":[{"name":"Clinic of Radiology, Clinical Center of the University of Sarajevo , Bolni\u010dka 25, Sarajevo 71000,","place":["Bosnia and Herzegovina"]}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2026,3,13]]},"reference":[{"key":"2026031302443315700_ref1","first-page":"311","article-title":"Strategies for CT radiation dose optimization","volume":"252","author":"Kalra","year":"2009","journal-title":"Radiology."},{"key":"2026031302443315700_ref2","doi-asserted-by":"publisher","first-page":"637","DOI":"10.1148\/radiol.2015142631","article-title":"Dual- and multi-energy CT: principles, technical approaches, and clinical applications","volume":"276","author":"McCollough","year":"2015","journal-title":"Radiology."},{"key":"2026031302443315700_ref3","doi-asserted-by":"crossref","first-page":"267","DOI":"10.1016\/j.jacr.2013.10.013","article-title":"CT protocol review and optimization","volume":"11","year":"2014","journal-title":"Journal of the American College of Radiology"},{"key":"2026031302443315700_ref4","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1097\/RLI.0000000000000537","article-title":"Automatic tube current modulation and tube voltage selection in pediatric computed tomography: a phantom study on radiation dose and image quality","volume":"54","year":"2019","journal-title":"Invest Radiol."},{"key":"2026031302443315700_ref5","first-page":"418","article-title":"Automatic patient centering for MDCT: effect on radiation dose","volume":"188","year":"2012","journal-title":"American Journal of Roentgenology"},{"key":"2026031302443315700_ref6","first-page":"1517\u201323","article-title":"The influence of miscentering on radiation dose during computed tomography head examinations and the role of localiser orientation: a phantom study","volume":"30","year":"2024","journal-title":"Radiography"},{"key":"2026031302443315700_ref7","article-title":"Efficient use of automatic exposure control systems in computed tomography requires correct patient positioning","volume":"50","year":"2009","journal-title":"Acta Radiol"},{"key":"2026031302443315700_ref8","doi-asserted-by":"publisher","first-page":"229","DOI":"10.2217\/iim.12.13","article-title":"CT artifacts: causes and reduction techniques","volume":"4","author":"Boas","year":"2012","journal-title":"Imaging Med"},{"key":"2026031302443315700_ref9","article-title":"Sensitivity and accuracy of volumetry of pulmonary nodules on low-dose 16- and 64-row multidetector CT: an anthropomorphic phantom study","volume":"23","year":"2013","journal-title":"Eur Radiol"},{"key":"2026031302443315700_ref10","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1088\/0952-4746\/34\/1\/103","article-title":"Relationships between patient size, dose and image noise under automatic tube current modulation systems","volume":"34","author":"Sookpeng","year":"2013","journal-title":"J Radiol Prot"},{"key":"2026031302443315700_ref11","article-title":"CTContour: an open-source Python pipeline for automatic contouring and calculation of mean SSDE along the abdomino-pelvic region for CT images; validation on fifteen systems","volume":"103","year":"2022","journal-title":"Physica Medica"},{"key":"2026031302443315700_ref12","volume":"203","year":"2014","journal-title":"AJR Am J Roentgenol"}],"container-title":["Radiation Protection Dosimetry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/rpd\/article-pdf\/202\/3%E2%80%934\/319\/67333237\/ncaf192.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/rpd\/article-pdf\/202\/3%E2%80%934\/319\/67333237\/ncaf192.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,13]],"date-time":"2026-03-13T06:44:37Z","timestamp":1773384277000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/rpd\/article\/202\/3%E2%80%934\/319\/8518630"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3]]},"references-count":12,"journal-issue":{"issue":"3\u20134","published-online":{"date-parts":[[2026,3,13]]},"published-print":{"date-parts":[[2026,3,13]]}},"URL":"https:\/\/doi.org\/10.1093\/rpd\/ncaf192","relation":{},"ISSN":["0144-8420","1742-3406"],"issn-type":[{"value":"0144-8420","type":"print"},{"value":"1742-3406","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2026,3]]},"published":{"date-parts":[[2026,3]]}}}