{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T10:05:34Z","timestamp":1780481134337,"version":"3.54.1"},"reference-count":12,"publisher":"Oxford University Press (OUP)","issue":"9","license":[{"start":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T00:00:00Z","timestamp":1780272000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/pages\/standard-publication-reuse-rights"}],"funder":[{"name":"Algiers Nuclear Research Center"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,6,3]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>This study evaluates neutron and photon equivalent dose sensitivity in patient organs during prostate three-dimensional conformal radiotherapy (3DCRT) using Monte Carlo simulations. A validated Varian Clinac 2100C LINAC model and a hybrid XCAT adult male phantom were used with an 18 MV photon beam. Component-wise sensitivity analysis showed that removal of the flattening filter caused the largest increase in neutron doses, with ratios of 1.49 in the testes, 1.39 in the bladder, and 1.38 in the colon, indicating a dominant shielding role. The primary collimator also showed significant shielding, with neutron dose ratios up to 1.29 in the rectum. Treatment room shielding contributed up to 61% of the neutron dose in the brain via room-return effects. Photon doses decreased with increasing distance from the field, highlighting spatial dependence and implications for radiological protection.<\/jats:p>","DOI":"10.1093\/rpd\/ncag027","type":"journal-article","created":{"date-parts":[[2026,3,3]],"date-time":"2026-03-03T12:32:29Z","timestamp":1772541149000},"page":"755-761","source":"Crossref","is-referenced-by-count":0,"title":["Sensitivity analysis of neutron and photon equivalent doses in patient organs during 3D conformal radiotherapy using Monte Carlo simulations"],"prefix":"10.1093","volume":"202","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7920-9461","authenticated-orcid":false,"given":"Asma","family":"Alem-Bezoubiri","sequence":"first","affiliation":[{"name":"Department of Radiological and Atomic Physics, Division of Physics , Nuclear Research Centre of Algiers (CRNA), B.P. 399, Alger-Gare, Algiers 16000,","place":["Algeria"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fethi","family":"Bezoubiri","sequence":"additional","affiliation":[{"name":"Atomic Energy Commission (COMENA) , 02, Boulevard Frantz Fanon , Algiers ,","place":["Algeria"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Speiser","sequence":"additional","affiliation":[{"name":"Englewood Hospital and Medical Center , Englewood, NJ ,","place":["United States"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hossam","family":"Donya","sequence":"additional","affiliation":[{"name":"Department of Physics, Faculty of Science, King Abdulaziz University , Jeddah 21589 ,","place":["Saudi Arabia"]},{"name":"Department of Physics, Faculty of Science, Menoufia University , Shibin El-Koom 32511 ,","place":["Egypt"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2026,6,3]]},"reference":[{"key":"2026060305104283500_ref1","doi-asserted-by":"publisher","first-page":"138","DOI":"10.1016\/j.rpor.2010.08.003","article-title":"A review on photoneutrons characteristics in radiation therapy with high-energy photon beams","volume":"15","author":"Naseri","year":"2010","journal-title":"Rep Pract Oncol Radiother"},{"key":"2026060305104283500_ref2","doi-asserted-by":"publisher","first-page":"40","DOI":"10.1016\/j.apradiso.2018.04.022","article-title":"Effect of each component of a LINAC therapy head on neutron and photon spectra","volume":"139","author":"Khabaz","year":"2018","journal-title":"Appl Radiat Isot"},{"key":"2026060305104283500_ref3","doi-asserted-by":"publisher","first-page":"438","DOI":"10.1038\/nrc3069","article-title":"Assessing the risk of second malignancies after modern radiotherapy","volume":"11","author":"Newhauser","year":"2011","journal-title":"Nat Rev Cancer"},{"key":"2026060305104283500_ref4","first-page":"060001","volume-title":"AIP Conference Proceedings","author":"Bezoubiri","year":"2018"},{"key":"2026060305104283500_ref5","doi-asserted-by":"publisher","volume":"25","journal-title":"Reports of Practical Oncology and Radiotherapy","DOI":"10.1016\/j.rpor.2019.12.029"},{"key":"2026060305104283500_ref6","doi-asserted-by":"publisher","first-page":"45","DOI":"10.3390\/qubs7030027","article-title":"GEANT4 simulation of photoneutron spectrum from medical LINACs and experimental validation","volume":"7","author":"Chernyaev","year":"2023","journal-title":"Med Phys Inter"},{"key":"2026060305104283500_ref7","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1177\/15593258231169807","article-title":"MCNPX estimation of photoneutron dose to eye voxel phantom from 18 MV LINAC","volume":"21","author":"Alghamdi","year":"2023","journal-title":"Radiat Prot Dosim"},{"key":"2026060305104283500_ref8","doi-asserted-by":"publisher","first-page":"381","DOI":"10.1016\/j.radphyschem.2013.07.013","article-title":"Monte Carlo estimation of photoneutrons spectra and dose equivalent around an 18 MV medical linear accelerator","volume":"97","author":"Alem-Bezoubiri","year":"2014","journal-title":"Radiat Phys Chem"},{"key":"2026060305104283500_ref9","doi-asserted-by":"publisher","first-page":"111595","DOI":"10.1016\/j.apradiso.2024.111595","article-title":"Monte Carlo study of organ doses and related risk for cancer in Algeria from scattered neutrons in prostate treatment involving 3D-CRT","volume":"216","author":"Alem-Bezoubiri","year":"2025","journal-title":"Appl Radiat Isot"},{"key":"2026060305104283500_ref10","doi-asserted-by":"publisher","first-page":"110986","DOI":"10.48550\/arXiv.2505.09245","article-title":"Evaluating the effectiveness of concrete and metal shields in photoneutron reduction using MCNPX","volume":"195","author":"Jahanimehr","year":"2025","journal-title":"Appl Radiat Isot"},{"key":"2026060305104283500_ref11","doi-asserted-by":"publisher","first-page":"219","DOI":"10.1007\/s00066-023-02138-x","article-title":"Effect of simultaneous integrated boost concepts on photoneutron and distant out-of-field doses in VMAT for prostate cancer","volume":"200","author":"Gauter-Fleckenstein","year":"2024","journal-title":"Strahlenther Onkol"},{"key":"2026060305104283500_ref12","doi-asserted-by":"publisher","first-page":"110065","DOI":"10.1016\/j.apradiso.2021.110065","article-title":"Monte Carlo study of organ doses and related risk for cancer in Algeria from scattered neutrons in prostate treatment involving 3D-CRT","volume":"180","author":"Alem-Bezoubiri","year":"2022","journal-title":"Appl Radiat Isot"}],"container-title":["Radiation Protection Dosimetry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/rpd\/article-pdf\/202\/9\/755\/68458605\/ncag027.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/rpd\/article-pdf\/202\/9\/755\/68458605\/ncag027.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T09:10:49Z","timestamp":1780477849000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/rpd\/article\/202\/9\/755\/8700446"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6]]},"references-count":12,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2026,6,3]]},"published-print":{"date-parts":[[2026,6,3]]}},"URL":"https:\/\/doi.org\/10.1093\/rpd\/ncag027","relation":{},"ISSN":["0144-8420","1742-3406"],"issn-type":[{"value":"0144-8420","type":"print"},{"value":"1742-3406","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2026,6]]},"published":{"date-parts":[[2026,6]]}}}