{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T15:02:25Z","timestamp":1790089345370,"version":"4.0.1"},"reference-count":27,"publisher":"Oxford University Press (OUP)","issue":"15","license":[{"start":{"date-parts":[[2026,6,9]],"date-time":"2026-06-09T00:00:00Z","timestamp":1780963200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/pages\/standard-publication-reuse-rights"}],"funder":[{"name":"EURADOS WG10"},{"name":"RENEB and Public Health England","id":[{"id":"https:\/\/ror.org\/00vbvha87","id-type":"ROR","asserted-by":"crossref"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,9,22]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Various methods of physical retrospective dosimetry based mainly on thermally and optically stimulated luminescence in daily-use items are employed to assess the dose after unplanned radiation exposure. The investigations are usually performed in laboratory conditions, but the situation will differ in a real scenario. This was the motivation for the field test organized by European Radiation Dosimetry Group and Running the European Network of Biological and Retrospective Physical Dosimetry. The field test was arranged outdoors, where phantoms equipped with mobile phones, payment cards, pieces of dental ceramics and enamel, salty snacks and salt dosemeters, cigarettes and textile bags were irradiated. This manuscript presents doses estimated at National Radiation Protection Institute, as one of participating laboratories, using mobile phones and salt dosemeters in comparison with reference values. When using glass from the display, acceptable agreement was achieved for emergency dosimetry purposes. Resistors and salt measurements led to a more significant overestimation, in the case of resistors up to five times the reference value.<\/jats:p>","DOI":"10.1093\/rpd\/ncag051","type":"journal-article","created":{"date-parts":[[2026,5,7]],"date-time":"2026-05-07T11:39:20Z","timestamp":1778153960000},"page":"1245-1252","source":"Crossref","is-referenced-by-count":0,"title":["EURADOS WG10 2019 field test of retrospective dosimetry methods: The NRPI results of mobile phones and salt dosemeters"],"prefix":"10.1093","volume":"202","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5077-9161","authenticated-orcid":false,"given":"Zina","family":"\u010cemusov\u00e1","sequence":"first","affiliation":[{"name":"National Radiation Protection Institute , Barto\u0161kova 28, 14000 Prague ,","place":["Czech Republic"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5376-0797","authenticated-orcid":false,"given":"Daniela","family":"Ekendahl","sequence":"additional","affiliation":[{"name":"National Radiation Protection Institute , Barto\u0161kova 28, 14000 Prague ,","place":["Czech Republic"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2026,6,9]]},"reference":[{"key":"2026092210132984700_ref1","first-page":"3","article-title":"ICRU report 94: methods for initial-phase assessment of individual doses following acute exposure to ionizing radiation","volume":"19","author":"International Commission on Radiation Units and Measurements","year":"2019","journal-title":"J ICRU"},{"key":"2026092210132984700_ref2","doi-asserted-by":"publisher","first-page":"99","DOI":"10.1080\/09553002.2016.1206233","article-title":"Integration of new biological and physical retrospective dosimetry methods into EU emergency response plans- joint RENEB and EURADOS inter-laboratory comparisons","volume":"93","author":"Ainsbury","year":"2017","journal-title":"Int J Radiat Biol"},{"key":"2026092210132984700_ref3","doi-asserted-by":"publisher","first-page":"888","DOI":"10.1080\/09553002.2021.1928782","article-title":"RENEB inter-laboratory comparison 2017: limits and pitfalls of ILCs","volume":"97","author":"Gregoire","year":"2021","journal-title":"Int J Radiat Biol"},{"key":"2026092210132984700_ref4","doi-asserted-by":"publisher","first-page":"475","DOI":"10.1016\/j.radmeas.2014.03.016","article-title":"Retrospective radiation dosimetry using OSL of electronic components: results of an inter-laboratory comparison","volume":"71","author":"Bassinet","year":"2014","journal-title":"Radiat Meas"},{"key":"2026092210132984700_ref5","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1080\/09553002.2016.1206230","article-title":"RENEB accident simulation exercise","volume":"93","author":"Brzozowska","year":"2017","journal-title":"Int J Radiat Biol"},{"key":"2026092210132984700_ref6","doi-asserted-by":"publisher","DOI":"10.1016\/j.radmeas.2021.106544","article-title":"Evaluation of physical retrospective dosimetry methods in a realistic accident scenario: results of a field test","volume":"142","author":"Discher","year":"2021","journal-title":"Radiat Meas"},{"key":"2026092210132984700_ref7","doi-asserted-by":"publisher","first-page":"9756","DOI":"10.1038\/s41598-021-88403-4","article-title":"Inter-laboratory comparison of gene expression biodosimetry for protracted radiation exposures as part of the RENEB and EURADOS WG10 2019 exercise","volume":"11","author":"Abend","year":"2021","journal-title":"Sci Rep"},{"key":"2026092210132984700_ref8","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1080\/09553002.2016.1221545","article-title":"Overview of physical dosimetry methods for triage application integrated in the new European network RENEB","volume":"93","author":"Trompier","year":"2017","journal-title":"Int J Radiat Biol"},{"key":"2026092210132984700_ref9","doi-asserted-by":"publisher","first-page":"1181","DOI":"10.1080\/09553002.2021.1941380","article-title":"RENEB\/EURADOS field exercise 2019: robust dose estimation under outdoor conditions based on the dicentric chromosome assay","volume":"97","author":"Endesfelder","year":"2021","journal-title":"Int J Radiat Biol"},{"key":"2026092210132984700_ref10","doi-asserted-by":"publisher","DOI":"10.1016\/j.radmeas.2024.107307","article-title":"Dose conversion in retrospective dosimetry: results and implications from an inter-laboratory comparison featuring a realistic exposure scenario","volume":"179","author":"Eakins","year":"2024","journal-title":"Radiat Meas"},{"key":"2026092210132984700_ref11","doi-asserted-by":"publisher","DOI":"10.1016\/j.radmeas.2024.107329","article-title":"Monte Carlo dosimetry for a EURADOS WG 10 and RENEB field test of retrospective dosimetry techniques in realistic exposure scenarios","volume":"180","author":"Kim","year":"2025","journal-title":"Radiat Meas"},{"key":"2026092210132984700_ref12","doi-asserted-by":"publisher","first-page":"253","DOI":"10.1667\/RADE-20-00243.1","article-title":"The 2019- 2020 EURADOS WG10 and RENEB field test of retrospective dosimetry methods in a small-scale incident involving ionizing radiation","volume":"195","author":"Waldner","year":"2021","journal-title":"Radiat Res"},{"key":"2026092210132984700_ref13","first-page":"65","article-title":"OSL in household salt (NaCl) for environmental, occupational and medical dosimetry","author":"Bernhardsson","year":"2009","journal-title":"Med Phys Baltic Stat"},{"key":"2026092210132984700_ref14","doi-asserted-by":"publisher","first-page":"740","DOI":"10.1097\/HP.0b013e31825d0e1b","article-title":"Comparative measurements of the external radiation exposure in a 137Cs contaminated village in Belarus based on optically stimulated luminescence in NaCl and thermoluminescence in LiF","volume":"103","author":"Bernhardsson","year":"2012","journal-title":"Health Phys"},{"key":"2026092210132984700_ref15","doi-asserted-by":"publisher","first-page":"240","DOI":"10.1016\/j.radmeas.2013.01.027","article-title":"Improvement of dose determination using glass display of mobile phones for accident dosimetry","volume":"56","author":"Discher","year":"2013","journal-title":"Radiat Meas"},{"key":"2026092210132984700_ref16","doi-asserted-by":"publisher","first-page":"134","DOI":"10.1093\/rpd\/ncr380","article-title":"Retrospective dosimetry with alumina substrate from electronic components","volume":"150","author":"Ekendahl","year":"2012","journal-title":"Radiat Prot Dosim"},{"key":"2026092210132984700_ref17","doi-asserted-by":"publisher","first-page":"206","DOI":"10.1093\/rpd\/ncz203","article-title":"Retrospective dose reconstruction with mobile phones and chip cards","volume":"186","author":"Ekendahl","year":"2019","journal-title":"Radiat Prot Dosim"},{"key":"2026092210132984700_ref18","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1016\/j.radmeas.2013.04.002","article-title":"Thermoluminescence of glass display from mobile phones for retrospective and accident dosimetry","volume":"53-54","author":"Discher","year":"2013","journal-title":"Radiat Meas"},{"key":"2026092210132984700_ref19","doi-asserted-by":"publisher","first-page":"36","DOI":"10.1093\/rpd\/ncq370","article-title":"NaCl as a retrospective and accident dosemeter","volume":"145","author":"Ekendahl","year":"2011","journal-title":"Radiat Prot Dosim"},{"key":"2026092210132984700_ref20","volume-title":"Optically stimulated luminescence dosimetry","author":"B\u00f8tter-Jensen","year":"2003","edition":"First"},{"key":"2026092210132984700_ref21","doi-asserted-by":"publisher","first-page":"329","DOI":"10.1093\/rpd\/ncx114","article-title":"Dosimetry with salt in mixed radiation fields of photons and neutrons","volume":"178","author":"Ekendahl","year":"2018","journal-title":"Radiat Prot Dosim"},{"key":"2026092210132984700_ref22","volume-title":"Radiological protection- X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy- Part 3: Calibration of area and personal dosemeters and the measurement of their response as a function of energy and angle of incidence.","author":"International Organization for Standardization"},{"key":"2026092210132984700_ref23","doi-asserted-by":"publisher","first-page":"621","DOI":"10.1016\/j.radmeas.2007.01.053","article-title":"Synthesis and physical characteristics of radiophotoluminescent glass dosimeters","volume":"42","author":"Hsu","year":"2007","journal-title":"Radiat Meas"},{"key":"2026092210132984700_ref24","volume-title":"Thermoluminescence Dosimetry Materials: Properties and Uses","author":"McKeever","year":"1995"},{"key":"2026092210132984700_ref25","doi-asserted-by":"publisher","DOI":"10.1016\/j.radmeas.2021.106615","article-title":"Investigations into the basic properties of different passive dosimetry systems used in environmental radiation monitoring in the aftermath of a nuclear or radiological event","volume":"146","author":"Kne\u017eevi\u0107","year":"2021","journal-title":"Radiat Meas"},{"key":"2026092210132984700_ref26","doi-asserted-by":"publisher","first-page":"1321","DOI":"10.1088\/1361-6498\/abc052","article-title":"Experimentally determined and Monte Carlo-calculated energy dependence of NaCl pellets read by optically stimulated luminescence for photon beams in the energy range 30 keV to 1.25 MeV","volume":"40","author":"Waldner","year":"2020","journal-title":"J Radiol Prot"},{"key":"2026092210132984700_ref27","doi-asserted-by":"publisher","DOI":"10.1016\/j.radmeas.2025.107443","article-title":"Thermoluminescence and optically stimulated luminescence dosimetry with NaCl detectors made at different sintering temperatures","volume":"184","author":"Ekendahl","year":"2025","journal-title":"Radiat Meas"}],"container-title":["Radiation Protection Dosimetry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/rpd\/article-pdf\/202\/15\/1245\/68500044\/ncag051.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/rpd\/article-pdf\/202\/15\/1245\/68500044\/ncag051.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T14:20:48Z","timestamp":1790086848000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/rpd\/article\/202\/15\/1245\/8704633"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,9]]},"references-count":27,"journal-issue":{"issue":"15","published-online":{"date-parts":[[2026,6,9]]},"published-print":{"date-parts":[[2026,9,22]]}},"URL":"https:\/\/doi.org\/10.1093\/rpd\/ncag051","relation":{},"ISSN":["0144-8420","1742-3406"],"issn-type":[{"value":"0144-8420","type":"print"},{"value":"1742-3406","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2026,9]]},"published":{"date-parts":[[2026,6,9]]}}}