{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T15:01:37Z","timestamp":1790089297665,"version":"4.0.1"},"reference-count":49,"publisher":"Oxford University Press (OUP)","issue":"15","license":[{"start":{"date-parts":[[2026,6,4]],"date-time":"2026-06-04T00:00:00Z","timestamp":1780531200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/pages\/standard-publication-reuse-rights"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,9,22]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Diagnostic reference levels (DRLs) are tools for optimizing medical exposures. We performed a retrospective analysis of 898 adult scintigraphic examinations acquired between 2018 and 2024 at a Peruvian hospital to establish institutional DRLs for eight procedures. Typical values were defined as the median administered activity, and the 75th percentiles were used as institutional action levels to trigger protocol review. Median weight-normalized activities ranged from 0.1\u00a0MBq\u00b7kg\u22121 for 131I thyroid uptake testing to 14.5\u00a0MBq\u00b7kg\u22121 for three-phase bone scintigraphy; corresponding derived effective dose estimates were ~1\u201345\u00a0mSv and are reported only for population-level benchmarking. Comparison with international DRLs showed broad concordance; however, bone scintigraphy exceeded several reference values by &amp;gt;25%, indicating opportunities for optimization. These results provide the first institutional DRLs reported in Peru, identify priorities for local quality improvement, and support periodic review within an optimization cycle.<\/jats:p>","DOI":"10.1093\/rpd\/ncag055","type":"journal-article","created":{"date-parts":[[2026,5,12]],"date-time":"2026-05-12T11:25:30Z","timestamp":1778585130000},"page":"1180-1191","source":"Crossref","is-referenced-by-count":0,"title":["Establishing typical diagnostic reference levels in a Peruvian nuclear medicine centre: a retrospective study"],"prefix":"10.1093","volume":"202","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4975-0147","authenticated-orcid":false,"given":"Paul Elias","family":"Panizo-Olivos","sequence":"first","affiliation":[{"name":"Nuclear Medicine Center, Hospital de Alta Complejidad Virgen de la Puerta , EsSALUD, M. Bastidas 309, La Esperanza 13013, Trujillo ,","place":["Peru"]},{"name":"Postgraduate Unit in Medical Physics, Faculty of Sciences, Universidad Nacional de Ingenier\u00eda (UNI) , Av. T\u00fapac Amaru 210, R\u00edmac, Lima ,","place":["Peru"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2805-9560","authenticated-orcid":false,"given":"Cecilia","family":"Querebal\u00fa-Garc\u00eda","sequence":"additional","affiliation":[{"name":"Nuclear Medicine Center, Hospital de Alta Complejidad Virgen de la Puerta , EsSALUD, M. Bastidas 309, La Esperanza 13013, Trujillo ,","place":["Peru"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0004-5133-1341","authenticated-orcid":false,"given":"Eduardo","family":"Garnique-Millones","sequence":"additional","affiliation":[{"name":"Nuclear Medicine Center, Hospital de Alta Complejidad Virgen de la Puerta , EsSALUD, M. Bastidas 309, La Esperanza 13013, Trujillo ,","place":["Peru"]},{"name":"Postgraduate Unit in Medical Physics, Faculty of Sciences, Universidad Nacional de Ingenier\u00eda (UNI) , Av. T\u00fapac Amaru 210, R\u00edmac, Lima ,","place":["Peru"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1020-8775","authenticated-orcid":false,"given":"Adlin","family":"L\u00f3pez-D\u00edaz","sequence":"additional","affiliation":[{"name":"Department of Physical Sciences, Center of Excellence in Physics and Engineering in Health, Universidad de La Frontera , Francisco Salazar 1145, Temuco, Araucan\u00eda ,","place":["Chile"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9815-9321","authenticated-orcid":false,"given":"Jhonny Antonio","family":"Benavente-Castillo","sequence":"additional","affiliation":[{"name":"Postgraduate Unit in Medical Physics, Faculty of Sciences, Universidad Nacional de Ingenier\u00eda (UNI) , Av. T\u00fapac Amaru 210, R\u00edmac, Lima ,","place":["Peru"]},{"name":"Secondary Standard Dosimetry Laboratory (LSCD), Peruvian Institute of Nuclear Energy (IPEN) , Av. Canad\u00e1 N\u00b0 1470 \u2013 San Borja, Lima ,","place":["Peru"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0711-7899","authenticated-orcid":false,"given":"Jorge L\u00e1zaro","family":"Delgado-Morales","sequence":"additional","affiliation":[{"name":"Department of Mathematics-Physics, Agrarian University of Havana , Carretera Tapaste y Autopista Nacional km 23 1\/2, San Jos\u00e9 de las Lajas, Mayabeque ,","place":["Cuba"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2026,6,4]]},"reference":[{"key":"2026092210134314300_ref1","author":"United Nations Scientific Committee on the Effects of Atomic Radiation","year":"2022"},{"key":"2026092210134314300_ref2","doi-asserted-by":"publisher","first-page":"108879","DOI":"10.1016\/j.nucmedbio.2024.108879","article-title":"Advancements in the development of radiopharmaceuticals for nuclear medicine applications in the treatment of bone metastases","volume":"130\u2013131","author":"Dyer","year":"2024","journal-title":"Nucl Med Biol"},{"key":"2026092210134314300_ref3","doi-asserted-by":"publisher","first-page":"e250","DOI":"10.1016\/S1470-2045(24)00037-8","article-title":"Trends in nuclear medicine and the radiopharmaceutical sciences in oncology: workforce challenges and training in the age of theranostics","volume":"25","author":"Scott","year":"2024","journal-title":"Lancet Oncol"},{"key":"2026092210134314300_ref4","doi-asserted-by":"publisher","first-page":"e236","DOI":"10.1016\/S1470-2045(24)00030-5","article-title":"Recent advances and impending challenges for the radiopharmaceutical sciences in oncology","volume":"25","author":"Lapi","year":"2024","journal-title":"Lancet Oncol"},{"key":"2026092210134314300_ref5","volume-title":"IAEA Safety Reports Series No. 112 Patient Radiation Exposure Monitoring in Medical Imaging","author":"IAEA","year":"2023"},{"key":"2026092210134314300_ref6","author":"IAEA","year":"2022"},{"key":"2026092210134314300_ref7","author":"Clement","year":"2024"},{"key":"2026092210134314300_ref8","doi-asserted-by":"publisher","first-page":"1163","DOI":"10.1097\/MNM.0000000000001630","article-title":"Current status of nuclear cardiology practice in Latin America and the Caribbean, in the era of multimodality cardiac imaging approach: 2022 update","volume":"43","author":"Peix","year":"2022","journal-title":"Nucl Med Commun"},{"key":"2026092210134314300_ref9","volume-title":"Instituto Peruano de Energia Nuclear Informe de Gesti\u00f3n A\u00f1o 2023","author":"IPEN","year":"2024"},{"key":"2026092210134314300_ref10"},{"key":"2026092210134314300_ref11","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1177\/0146645317717209","article-title":"ICRP publication 135: diagnostic reference levels in medical imaging","volume":"46","author":"Va\u00f1\u00f3","year":"2017","journal-title":"Ann ICRP"},{"key":"2026092210134314300_ref12","volume-title":"Annals of the ICRP"},{"key":"2026092210134314300_ref13","first-page":"1","volume-title":"IBM SPSS Statistics 20 Documentation. Version 20.0.","author":"IBM corporation","year":"2016"},{"key":"2026092210134314300_ref14","doi-asserted-by":"publisher","first-page":"64","DOI":"10.1007\/s13139-019-00585-y","article-title":"Diagnostic reference levels for adult nuclear medicine imaging established from the National Survey in Korea","volume":"53","author":"Song","year":"2019","journal-title":"Nucl Med Mol Imaging"},{"key":"2026092210134314300_ref15","doi-asserted-by":"publisher","first-page":"799","DOI":"10.1007\/s12149-020-01512-4","article-title":"The 2020 national diagnostic reference levels for nuclear medicine in Japan","volume":"34","author":"Abe","year":"2020","journal-title":"Ann Nucl Med"},{"key":"2026092210134314300_ref16","doi-asserted-by":"publisher","first-page":"54","DOI":"10.2967\/jnmt.121.262175","article-title":"National diagnostic reference levels for nuclear medicine in Kuwait","volume":"50","author":"Alnaaimi","year":"2022","journal-title":"J Nucl Med Technol"},{"key":"2026092210134314300_ref17"},{"key":"2026092210134314300_ref18","doi-asserted-by":"publisher","first-page":"258","DOI":"10.4236\/ojrad.2016.64034","article-title":"Establishment of dose reference levels for nuclear medicine in Sudan","volume":"06","author":"Ali","year":"2016","journal-title":"Open J Radiol"},{"key":"2026092210134314300_ref19","author":"Pozo","year":"2022"},{"key":"2026092210134314300_ref20"},{"key":"2026092210134314300_ref21","doi-asserted-by":"publisher","first-page":"525","DOI":"10.1097\/MNM.0000000000000462","article-title":"Diagnostic reference level: an important tool for reducing radiation doses in adult and pediatric nuclear medicine procedures in Brazil","volume":"37","author":"Willegaignon","year":"2016","journal-title":"Nucl Med Commun"},{"key":"2026092210134314300_ref22","first-page":"1","volume-title":"Guidance National Diagnostic Reference Levels (NDRLs) from 20 November 2024 Updated 20 November 2024","author":"UK Health Security Agency","year":"2024"},{"key":"2026092210134314300_ref23","author":"Maronna","edition":"2nd ed."},{"key":"2026092210134314300_ref24","doi-asserted-by":"publisher","first-page":"1177","DOI":"10.1007\/s12149-021-01656-x","article-title":"Optimization of injection dose in 18F-FDG PET\/CT based on the 2020 national diagnostic reference levels for nuclear medicine in Japan","volume":"35","author":"Sagara","year":"2021","journal-title":"Ann Nucl Med"},{"key":"2026092210134314300_ref25","doi-asserted-by":"publisher","volume":"10","journal-title":"EJNMMI Physics","DOI":"10.1186\/s40658-023-00533-y"},{"key":"2026092210134314300_ref26","doi-asserted-by":"publisher","first-page":"180","DOI":"10.1007\/s13139-023-00795-5","article-title":"Optimization of BMI-based images for overweight and obese patients \u2014 implications on image quality, quantification, and radiation dose in whole body 18F-FDG PET\/CT imaging","volume":"57","author":"Bouchareb","year":"2023","journal-title":"Nucl Med Mol Imaging"},{"key":"2026092210134314300_ref27","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejmp.2023.102565","article-title":"Establishment and utilization of diagnostic reference levels in medical imaging: results from a survey and consultation under the IAEA technical cooperation programme in Europe and Central Asia","volume":"108","author":"Faj","year":"2023","journal-title":"Phys Med"},{"key":"2026092210134314300_ref28","doi-asserted-by":"publisher","first-page":"158\u2013162","DOI":"10.2967\/jnmt.123.266836","article-title":"Establishment of national diagnostic reference levels for administered activity in diagnostic nuclear medicine in Thailand","volume":"52","author":"Suttho","year":"2024","journal-title":"J Nucl Med Technol"},{"key":"2026092210134314300_ref29","doi-asserted-by":"publisher","first-page":"007","DOI":"10.1055\/s-0042-1751053","article-title":"Utility of 99m technetium pertechnetate thyroid scan and uptake in thyrotoxic patients: Jordanian experience","volume":"22","author":"Al-Muqbel","year":"2023","journal-title":"World J Nucl Med"},{"key":"2026092210134314300_ref30","doi-asserted-by":"publisher","DOI":"10.1016\/j.lpm.2022.104116","article-title":"Thyroid functional and molecular imaging","volume":"51","author":"Giovanella","year":"2022","journal-title":"Presse Med"},{"key":"2026092210134314300_ref31","doi-asserted-by":"publisher","first-page":"2514","DOI":"10.1007\/s00259-019-04472-8","article-title":"EANM practice guideline\/SNMMI procedure standard for RAIU and thyroid scintigraphy","volume":"46","author":"Giovanella","year":"2019","journal-title":"Eur J Nucl Med Mol Imaging"},{"key":"2026092210134314300_ref32","doi-asserted-by":"publisher","first-page":"283","DOI":"10.14201\/orl.21496","article-title":"Medicina nuclear. Diagn\u00f3stico de la patolog\u00eda de tiroides y paratiroides","volume":"11","author":"Garc\u00eda-Talavera","year":"2019","journal-title":"Rev ORL"},{"key":"2026092210134314300_ref33","doi-asserted-by":"publisher","first-page":"2138","DOI":"10.1210\/jc.2013-4390","article-title":"Low-activity 124I-PET\/low-dose CT versus 131I probe measurements in pretherapy assessment of radioiodine uptake in benign thyroid diseases","volume":"99","author":"Westphal","year":"2014","journal-title":"J Clin Endocrinol Metab"},{"key":"2026092210134314300_ref34","doi-asserted-by":"publisher","first-page":"250","DOI":"10.1016\/j.zemedi.2011.01.006","article-title":"Dosimetry prior to I-131-therapy of benign thyroid disease","volume":"21","author":"H\u00e4nscheid","year":"2011","journal-title":"Z Med Phys"},{"key":"2026092210134314300_ref35","doi-asserted-by":"publisher","first-page":"45","DOI":"10.2967\/jnmt.117.198077","article-title":"\u03b3-camera-based method for measuring the \u03b3-count from 131I capsules: an alternative to the thyroid uptake probe","volume":"46","author":"Menon","year":"2018","journal-title":"J Nucl Med Technol"},{"key":"2026092210134314300_ref36","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1159\/000541147","article-title":"Comparison of thyroid uptake values measured from 131I scintigraphy and uptake probe in hyperthyroid patients","volume":"33","author":"Yeyin","year":"2024","journal-title":"Med Princ Pract"},{"key":"2026092210134314300_ref37","doi-asserted-by":"publisher","first-page":"283","DOI":"10.1016\/j.zemedi.2021.11.007","article-title":"Diagnostic reference levels for nuclear medicine imaging in Austria: a nationwide survey of used dose levels for adult patients","volume":"32","author":"Wachabauer","year":"2022","journal-title":"Z Med Phys"},{"key":"2026092210134314300_ref38","doi-asserted-by":"publisher","first-page":"1339","DOI":"10.1093\/rpd\/ncae170","article-title":"Evaluation of patients\u2019 radiation doses and establishment of institutional diagnostic reference levels in nuclear medicine in Oman","volume":"200","author":"Ebrahim","year":"2024","journal-title":"Radiat Prot Dosim"},{"key":"2026092210134314300_ref39","volume-title":"Analysis of Data for Updating Diagnostic Reference Levels in Radiology and Nuclear Medecine 2019\u20132021 Report","author":"Institut De Radioprotection Et De S\u00fbret\u00e9 Nucl\u00e9aire","year":"2023"},{"key":"2026092210134314300_ref40","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1186\/s13244-023-01369-x","article-title":"How to establish and use local diagnostic reference levels: an ESR EuroSafe imaging expert statement","volume":"14","author":"Damilakis","year":"2023","journal-title":"Insights Imaging"},{"key":"2026092210134314300_ref41","doi-asserted-by":"publisher","first-page":"294","DOI":"10.1051\/radiopro\/2025043","article-title":"Les niveaux de r\u00e9f\u00e9rence diagnostiques en imagerie m\u00e9dicale : exigences pour l\u2019optimisation de la radioprotection des patients","volume":"60","author":"Habib","year":"2025","journal-title":"Radioprotection"},{"key":"2026092210134314300_ref42","doi-asserted-by":"publisher","first-page":"104984","DOI":"10.1016\/j.ejmp.2025.104984","article-title":"Diagnostic reference levels in nuclear medicine for positron emission tomography examinations: first Italian multicenter data collection","volume":"133","author":"Zorz","year":"2025","journal-title":"Phys Med"},{"key":"2026092210134314300_ref43","doi-asserted-by":"publisher","first-page":"031520","DOI":"10.1088\/1361-6498\/ae0650","article-title":"Regional diagnostic reference levels in paediatric interventional cardiology in Latin America and the Caribbean countries","volume":"45","author":"Ubeda","year":"2025","journal-title":"J Radiol Prot"},{"key":"2026092210134314300_ref44","first-page":"338","article-title":"IAEA RLA 6091: enhancing capacity building of medical physicists in Latin America and Caribbean","volume":"10","author":"Renha","year":"2022","journal-title":"Med Phys Int"},{"key":"2026092210134314300_ref45","doi-asserted-by":"publisher","first-page":"633","DOI":"10.1097\/HP.0000000000001850","article-title":"Regional workshop on optimization of protection in pediatric interventional radiology in Latin American and Caribbean countries","volume":"127","author":"Ubeda","year":"2024","journal-title":"Health Phys"},{"key":"2026092210134314300_ref46","doi-asserted-by":"publisher","DOI":"10.1051\/radiopro\/2025014","article-title":"Evaluation of an asynchronous virtual course for continuing education in radiation protection in nuclear medicine in Latin America: outcomes and lessons learned","volume":"60","author":"L\u00f3pez","year":"2025","journal-title":"Radioprotection"},{"key":"2026092210134314300_ref47","doi-asserted-by":"publisher","first-page":"112043","DOI":"10.1016\/j.apradiso.2025.112043","article-title":"Setting up a national diagnostic reference level for computed tomography for the public sector in Costa Rica: first step","volume":"225","author":"Gonz\u00e1lez-L\u00f3pez","year":"2025","journal-title":"Appl Radiat Isot"},{"key":"2026092210134314300_ref48","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2023.111191","article-title":"Establishing national clinical diagnostic reference levels and achievable doses for CT examinations in Brazil: a prospective study","volume":"169","author":"Oliveira Bernardo","year":"2023","journal-title":"Eur J Radiol"},{"key":"2026092210134314300_ref49","first-page":"37","article-title":"Niveles de Referencia Para Diagn\u00f3stico seg\u00fan PUBMED: \u00bfes suficiente la informaci\u00f3n disponible?","volume":"9","author":"L\u00f3pez","year":"2023","journal-title":"J Health Med Sci"}],"container-title":["Radiation Protection Dosimetry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/rpd\/article-pdf\/202\/15\/1180\/68476293\/ncag055.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/rpd\/article-pdf\/202\/15\/1180\/68476293\/ncag055.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T14:21:16Z","timestamp":1790086876000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/rpd\/article\/202\/15\/1180\/8702534"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,4]]},"references-count":49,"journal-issue":{"issue":"15","published-online":{"date-parts":[[2026,6,4]]},"published-print":{"date-parts":[[2026,9,22]]}},"URL":"https:\/\/doi.org\/10.1093\/rpd\/ncag055","relation":{},"ISSN":["0144-8420","1742-3406"],"issn-type":[{"value":"0144-8420","type":"print"},{"value":"1742-3406","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2026,9]]},"published":{"date-parts":[[2026,6,4]]}}}