{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T15:02:51Z","timestamp":1790089371884,"version":"4.0.1"},"reference-count":34,"publisher":"Oxford University Press (OUP)","issue":"15","license":[{"start":{"date-parts":[[2026,6,4]],"date-time":"2026-06-04T00:00:00Z","timestamp":1780531200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/pages\/standard-publication-reuse-rights"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,9,22]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Typical values, as defined by the International Commission on Radiological Protection, support the optimization of protection in Computed Tomography (CT). They provide comparisons when new technologies are introduced, as well as for assessing the impact of factors such as the number of phases per examination, image-quality adjustments, and clinical-indication-based prescribing. This study assessed CT dose levels in a radiology department using a two-phase approach. Part I retrospectively assessed volume computed tomography dose index, dose length product, and size specific dose estimate values (2021\u20132022) across clinical indications and compared them with international Diagnostic Reference Levels. Protocol standardization, staff training, and optimization measures were implemented. Part II prospectively evaluated outcomes in 2024. Results showed that median dose values frequently exceeded international benchmarks and revealed variability in local practice. After optimization, most examinations demonstrated dose reductions of up to 61%, although some procedures remained ~20% above references. These findings highlight how multidisciplinary collaboration and staff education can strengthen radiation-protection culture and support clinically aligned imaging practice.<\/jats:p>","DOI":"10.1093\/rpd\/ncag056","type":"journal-article","created":{"date-parts":[[2026,5,15]],"date-time":"2026-05-15T11:42:16Z","timestamp":1778845336000},"page":"1192-1208","source":"Crossref","is-referenced-by-count":0,"title":["Establishment of typical values in computed tomography to support the optimization of protection in clinical practice"],"prefix":"10.1093","volume":"202","author":[{"ORCID":"https:\/\/orcid.org\/0009-0003-0201-6655","authenticated-orcid":false,"given":"Diogo","family":"Madaleno","sequence":"first","affiliation":[{"name":"Imagiologia, Unidade Local de Sa\u00fade da Cova da Beira , Alameda P\u00earo da Covilh\u00e3, 6200-251 Covilh\u00e3 , Castelo Branco,","place":["Portugal"]},{"name":"Instituto de Plasmas e Fus\u00e3o Nuclear, Instituto Superior T\u00e9cnico, Universidade de Lisboa , Av. Rovisco Pais 1, 1049-001 Lisboa ,","place":["Portugal"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cec\u00edlia","family":"Borges","sequence":"additional","affiliation":[{"name":"Radiation Protection Department, CUF Hospitals & Clinics , Av. do Forte 3, 2nd floor, 2790-072 Carnaxide , Lisboa,","place":["Portugal"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"In\u00eas","family":"Pereira","sequence":"additional","affiliation":[{"name":"Unidade Local de Sa\u00fade da Lez\u00edria, Hospital Distrital de Santar\u00e9m , Av. Bernardo Santareno, 2005-177 Santar\u00e9m ,","place":["Portugal"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joana","family":"Santos","sequence":"additional","affiliation":[{"name":"Coimbra Health School, Medical Imaging and Radiotherapy, Polytechnic University of Coimbra , Corti\u00e7os, S. Martinho do Bispo, 3045-093 Coimbra ,","place":["Portugal"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pedro","family":"Vaz","sequence":"additional","affiliation":[{"name":"Instituto de Plasmas e Fus\u00e3o Nuclear, Instituto Superior T\u00e9cnico, Universidade de Lisboa , Av. Rovisco Pais 1, 1049-001 Lisboa ,","place":["Portugal"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2026,6,4]]},"reference":[{"key":"2026092210135670000_ref1","doi-asserted-by":"publisher","first-page":"20210389","DOI":"10.1259\/bjr.20210389","article-title":"Radiation risk issues in recurrent imaging","volume":"94","author":"Brower","year":"2021","journal-title":"Br J Radiol"},{"key":"2026092210135670000_ref2","volume-title":"Sources, effects and risks of ionizing radiation. UNSCEAR Report 2020\/2021\u2013Scientific Annex A\u2013Evaluation of medical exposure to ionizing radiation","author":"United Nations Scientific Committee on the Effects of Atomic Radiation","year":"2022"},{"key":"2026092210135670000_ref3","volume-title":"Healthcare resource statistics \u2013 technical resources and medical technology","author":"Eurostat","year":"2024"},{"key":"2026092210135670000_ref4","volume-title":"Size-specific dose estimate (SSDE) in pediatric and adult body CT examinations","author":"American Association of Physicists in Medicine Task Group 204","year":"2011"},{"key":"2026092210135670000_ref5","volume-title":"Patient radiation exposure monitoring in medical imaging","author":"International Atomic Energy Agency","year":"2023"},{"key":"2026092210135670000_ref6","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1177\/0146645317717209","article-title":"ICRP publication 135\u2013diagnostic reference levels in medical imaging","volume":"46","author":"Va\u00f1\u00f3","year":"2017","journal-title":"Ann ICRP"},{"key":"2026092210135670000_ref7","volume-title":"Recommendation on the establishment, review and use of diagnostic reference levels for radiodiagnostic examinations and interventional radiology procedures","author":"European Commission","year":"2026"},{"key":"2026092210135670000_ref8","doi-asserted-by":"publisher","first-page":"205","DOI":"10.4274\/dir.2023.232265","article-title":"Establishment of local diagnostic reference levels for computed tomography with cloud-based automated dose-tracking software in T\u00fcrkiye","volume":"30","author":"Kahraman","year":"2024","journal-title":"Diagn Interv Radiol"},{"key":"2026092210135670000_ref9","doi-asserted-by":"publisher","first-page":"96","DOI":"10.1186\/s13244-020-00899-y","article-title":"Diagnostic reference levels based on clinical indications in computed tomography: a literature review","volume":"11","author":"Paulo","year":"2020","journal-title":"Insights Imaging"},{"key":"2026092210135670000_ref10","doi-asserted-by":"publisher","first-page":"285","DOI":"10.1016\/j.ejmp.2021.03.018","article-title":"The growing potential of diagnostic reference levels as a dynamic tool for dose optimization","volume":"84","author":"Damilakis","year":"2021","journal-title":"Phys Med"},{"key":"2026092210135670000_ref11","volume-title":"European study on clinical diagnostic reference levels for X-ray medical imaging \u2013 EUCLID","author":"Damilakis","year":"2021"},{"key":"2026092210135670000_ref12","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1186\/s13244-023-01369-x","article-title":"How to establish and use local diagnostic reference levels: an ESR EuroSafe imaging expert statement","volume":"14","author":"Damilakis","year":"2023","journal-title":"Insights Imaging"},{"key":"2026092210135670000_ref13","doi-asserted-by":"publisher","first-page":"961","DOI":"10.1016\/j.radi.2023.07.011","article-title":"Size based dependence of patient dose metrics, and image quality metrics for clinical indicator-based imaging protocols in abdominal CT procedures","volume":"29","author":"Sebelego","year":"2023","journal-title":"Radiography"},{"key":"2026092210135670000_ref14","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1186\/s13244-025-02028-z","article-title":"Current practices and perceptions on diagnostic reference levels: a EuroSafe imaging survey analysis","volume":"16","author":"Damilakis","year":"2025","journal-title":"Insights Imaging"},{"key":"2026092210135670000_ref15","doi-asserted-by":"publisher","first-page":"786","DOI":"10.1016\/j.radi.2023.05.003","article-title":"Investigating CT head diagnostic reference levels based on indication-based protocols \u2013 a single site study","volume":"29","author":"Tan","year":"2023","journal-title":"Radiography"},{"key":"2026092210135670000_ref16","doi-asserted-by":"publisher","first-page":"12","DOI":"10.5114\/pjr.2023.124376","article-title":"Summary of radiation dose management and optimization: comparison of radiation protection measures between Poland and other countries","volume":"88","author":"Jasieniak","year":"2023","journal-title":"Pol J Radiol"},{"key":"2026092210135670000_ref17","volume-title":"Enhancing radiation safety culture in health care: guidance for health care providers","author":"World Health Organization","year":"2024"},{"key":"2026092210135670000_ref18","volume-title":"European guidelines on quality criteria for computed tomography","author":"European Commission","year":"2000"},{"key":"2026092210135670000_ref19","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1093\/jamia\/ocw035","article-title":"Patient crossover and potentially avoidable repeat computed tomography exams across a health information exchange","volume":"24","author":"Slovis","year":"2017","journal-title":"J Am Med Inform Assoc"},{"key":"2026092210135670000_ref20","doi-asserted-by":"publisher","first-page":"1596","DOI":"10.1093\/bjr\/tqaf178","article-title":"Are high-dose CT examinations on the rise?","volume":"98","author":"Rehani","year":"2025","journal-title":"Br J Radiol"},{"key":"2026092210135670000_ref21","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1186\/s13244-023-01371-3","article-title":"Does clinical decision support system promote expert consensus for appropriate imaging referrals? Chest\u2013abdominal\u2013pelvis CT as a case study","volume":"14","author":"Markus","year":"2023","journal-title":"Insights Imaging"},{"key":"2026092210135670000_ref22","doi-asserted-by":"publisher","first-page":"111933","DOI":"10.1016\/j.ejrad.2025.111933","article-title":"Using evidence-based imaging referral guidelines to facilitate appropriate imaging: are they all the same?","volume":"183","author":"Tay","year":"2025","journal-title":"Eur J Radiol"},{"key":"2026092210135670000_ref23","doi-asserted-by":"publisher","first-page":"532","DOI":"10.1007\/s00330-024-10938-7","article-title":"Impact and effect of imaging referral guidelines on patients and radiology services: a systematic review","volume":"35","author":"Tay","year":"2024","journal-title":"Eur Radiol"},{"key":"2026092210135670000_ref24","doi-asserted-by":"publisher","first-page":"4459","DOI":"10.1007\/s00330-020-07652-5","article-title":"CT diagnostic reference levels based on clinical indications: results of a large-scale European survey","volume":"31","author":"Tsapaki","year":"2021","journal-title":"Eur Radiol"},{"key":"2026092210135670000_ref25","doi-asserted-by":"publisher","first-page":"581","DOI":"10.1148\/radiol.2017170285","article-title":"Evaluation of kidney stones with reduced-radiation dose CT: progress from 2011\u20132012 to 2015\u20132016 \u2013 not there yet","volume":"286","author":"Weisenthal","year":"2018","journal-title":"Radiology"},{"key":"2026092210135670000_ref26","volume-title":"Computed tomography for technologists: a comprehensive text","author":"Romans","year":"2018","edition":"2nd"},{"key":"2026092210135670000_ref27","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1111\/bju.15116","article-title":"A prospective, matched comparison of ultra-low and standard-dose computed tomography for assessment of renal colic","volume":"126","author":"Roberts","year":"2020","journal-title":"BJU Int"},{"key":"2026092210135670000_ref28","doi-asserted-by":"publisher","first-page":"109861","DOI":"10.1016\/j.ejrad.2021.109861","article-title":"Simplified size adjusted dose reference levels for adult CT examinations: a regional study","volume":"142","author":"Moghadam","year":"2021","journal-title":"Eur J Radiol"},{"key":"2026092210135670000_ref29","doi-asserted-by":"publisher","first-page":"112813","DOI":"10.1016\/j.radphyschem.2025.112813","article-title":"A study of SSDE, CTDI, and DLP dose indexes for establishing diagnostic reference levels in pediatric CT exams","volume":"235","author":"Monteiro","year":"2025","journal-title":"Radiat Phys Chem"},{"key":"2026092210135670000_ref30","doi-asserted-by":"publisher","first-page":"1142","DOI":"10.1093\/rpd\/ncad157","article-title":"Survey of computed tomography practice in Ukraine and establishment of national diagnostic reference levels for most common CT examinations of adults","volume":"199","author":"Stadnyk","year":"2023","journal-title":"Radiat Prot Dosim"},{"key":"2026092210135670000_ref31","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1016\/j.ejmp.2019.04.004","article-title":"Patient dose evaluation in computed tomography: a French national study based on clinical indications","volume":"61","author":"Habib Geryes","year":"2019","journal-title":"Phys Med"},{"key":"2026092210135670000_ref32","volume-title":"National diagnostic reference levels (NDRLs) from 20 November 2024","author":"UK Health Security Agency"},{"key":"2026092210135670000_ref33","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1002\/jmrs.372","article-title":"Updated Australian diagnostic reference levels for adult CT","volume":"67","author":"Lee","year":"2020","journal-title":"J Med Radiat Sci"},{"key":"2026092210135670000_ref34","volume-title":"Diagnostic reference levels guidance on the establishment, use and review of diagnostic reference levels for medical exposure to ionising radiation","author":"Health Information and Quality Authority","year":"2023"}],"container-title":["Radiation Protection Dosimetry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/rpd\/article-pdf\/202\/15\/1192\/68475913\/ncag056.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/rpd\/article-pdf\/202\/15\/1192\/68475913\/ncag056.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T14:21:53Z","timestamp":1790086913000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/rpd\/article\/202\/15\/1192\/8702476"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,4]]},"references-count":34,"journal-issue":{"issue":"15","published-online":{"date-parts":[[2026,6,4]]},"published-print":{"date-parts":[[2026,9,22]]}},"URL":"https:\/\/doi.org\/10.1093\/rpd\/ncag056","relation":{},"ISSN":["0144-8420","1742-3406"],"issn-type":[{"value":"0144-8420","type":"print"},{"value":"1742-3406","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2026,9]]},"published":{"date-parts":[[2026,6,4]]}}}