{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T11:53:07Z","timestamp":1791287587110,"version":"4.1.0"},"reference-count":28,"publisher":"Oxford University Press (OUP)","issue":"16","license":[{"start":{"date-parts":[[2026,7,14]],"date-time":"2026-07-14T00:00:00Z","timestamp":1783987200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/pages\/standard-publication-reuse-rights"}],"funder":[{"DOI":"10.13039\/501100000646","name":"JSPS","doi-asserted-by":"publisher","award":["JP23K07143"],"award-info":[{"award-number":["JP23K07143"]}],"id":[{"id":"10.13039\/501100000646","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,10,6]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>In diagnostic computed tomography (CT), radiological technologists and assisting staff may need to remain inside the CT room during patient assistance. Understanding temporal changes in scattered radiation distribution is therefore important for reducing occupational exposure. Conventional measurements mainly provide instantaneous dose rates or accumulated doses and are less suited to intuitively capturing temporal changes during CT scanning. This study conducted a fundamental investigation of a visualization approach, defined as dynamic dose distribution (DDD), based on time-resolved air kerma measurements obtained with a semiconductor survey meter. Scattered radiation was measured during chest-to-pelvis helical CT scanning of an anthropomorphic phantom under fixed tube current and automatic exposure control conditions. DDD allowed temporal changes in scattered radiation distribution to be visually identified in relation to tube current modulation, patient table position, and measurement height. DDD may provide useful temporal information for considering staff positioning and reducing occupational exposure.<\/jats:p>","DOI":"10.1093\/rpd\/ncag073","type":"journal-article","created":{"date-parts":[[2026,7,14]],"date-time":"2026-07-14T18:49:59Z","timestamp":1784054999000},"page":"1354-1364","source":"Crossref","is-referenced-by-count":0,"title":["Visualization of time-resolved scattered radiation distribution in a computed tomography room utilizing a semiconductor survey meter"],"prefix":"10.1093","volume":"202","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0273-0755","authenticated-orcid":false,"given":"Masanao","family":"Kobayashi","sequence":"first","affiliation":[{"name":"Graduate School of Medical Sciences, Fujita Health University , 1-98 Dengakugakubo, Kutsukake-cho, Toyoake, Aichi ,","place":["Japan"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Juria","family":"Suzuki","sequence":"additional","affiliation":[{"name":"Department of Radiology, Fujita Health University Okazaki Medical Center , 1 Gotannda, Harisaki-cho, Okazaki, Aichi ,","place":["Japan"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yusei","family":"Nishihara","sequence":"additional","affiliation":[{"name":"Department of Radiology, Fujita Health University Hospital , 1-98 Dengakugakubo, Kutsukake-cho, Toyoake, Aichi ,","place":["Japan"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5257-6162","authenticated-orcid":false,"given":"Tomonobu","family":"Haba","sequence":"additional","affiliation":[{"name":"Graduate School of Medical Sciences, Fujita Health University , 1-98 Dengakugakubo, Kutsukake-cho, Toyoake, Aichi ,","place":["Japan"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shigeki","family":"Kobayashi","sequence":"additional","affiliation":[{"name":"Graduate School of Medical Sciences, Fujita Health University , 1-98 Dengakugakubo, Kutsukake-cho, Toyoake, Aichi ,","place":["Japan"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2026,7,14]]},"reference":[{"key":"2026100607114001800_ref1","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.icrp.2012.02.001","article-title":"ICRP Publication 118: ICRP statement on tissue reactions and early and late effects of radiation in normal tissues and organs--threshold doses for tissue reactions in a radiation protection context","volume":"41","author":"Stewart","year":"2012","journal-title":"Ann ICRP"},{"key":"2026100607114001800_ref2","volume-title":"Radiation Protection and Safety of Radiation Sources: International Basic Safety Standards. General Safety Requirements Part 3","author":"International Atomic Energy Agency (IAEA)","year":"2014"},{"key":"2026100607114001800_ref3","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1016\/j.icrp.2011.01.002","article-title":"ICRP Publication 113. Education and training in radiological protection for diagnostic and interventional procedures","volume":"39","author":"Va\u00f1o","year":"2009","journal-title":"Ann ICRP"},{"key":"2026100607114001800_ref4","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1177\/0146645317746010","article-title":"ICRP Publication 138: ethical foundations of the system of radiological protection","volume":"47","author":"Cho","year":"2018","journal-title":"Ann ICRP"},{"key":"2026100607114001800_ref5","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1016\/j.icrp.2008.08.001","article-title":"ICRP Publication 105. Radiation protection in medicine","volume":"37","author":"ICRP","year":"2007","journal-title":"Ann ICRP"},{"key":"2026100607114001800_ref6","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.icrp.2012.09.001","article-title":"ICRP Publication 120: radiological protection in cardiology","volume":"42","author":"Cousins","year":"2013","journal-title":"Ann ICRP"},{"key":"2026100607114001800_ref7","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.icrp.2012.03.001","article-title":"ICRP Publication 117. Radiological protection in fluoroscopically guided procedures performed outside the imaging department","volume":"40","author":"Rehani","year":"2010","journal-title":"Ann ICRP"},{"key":"2026100607114001800_ref8"},{"key":"2026100607114001800_ref9","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1177\/0146645317717209","article-title":"ICRP Publication 135: diagnostic reference levels in medical imaging","volume":"46","author":"Va\u00f1\u00f3","year":"2017","journal-title":"Ann ICRP"},{"key":"2026100607114001800_ref10","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1177\/0146645317750356","article-title":"ICRP Publication 139: occupational radiological protection in interventional procedures","volume":"47","author":"L\u00f3pez","year":"2018","journal-title":"Ann ICRP"},{"key":"2026100607114001800_ref11","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1007\/s00330-017-5177-1","article-title":"Evaluation of geometric efficiency and radiation exposure in z-axis for volume scan","volume":"143","author":"Kobayashi","year":"2011","journal-title":"Radiat Prot Dosim"},{"key":"2026100607114001800_ref12","doi-asserted-by":"publisher","first-page":"646","DOI":"10.3390\/diagnostics11040646","article-title":"Occupational radiation dose to eye lenses in CT-guided interventions using MDCT-fluoroscopy","volume":"11","author":"Inaba","year":"2021","journal-title":"Diagnostics (Basel)"},{"key":"2026100607114001800_ref13","doi-asserted-by":"publisher","first-page":"403","DOI":"10.1093\/rpd\/ncq100","article-title":"Criteria for establishing shielding of multi-detector computed tomography (MDCT) rooms","volume":"139","author":"Verdun","year":"2010","journal-title":"Radiat Prot Dosim"},{"key":"2026100607114001800_ref14","doi-asserted-by":"publisher","first-page":"268","DOI":"10.1016\/j.jradnu.2021.04.006","article-title":"Development of visual educational materials for radiation protection in computed tomography","volume":"40","author":"Daioku","year":"2021","journal-title":"J Radiol Nurs"},{"key":"2026100607114001800_ref15","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1007\/s12194-019-00550-6","article-title":"A more accurate and safer method for the measurement of scattered radiation in X-ray examination rooms","volume":"13","author":"Nakamura","year":"2020","journal-title":"Radiol Phys Technol"},{"key":"2026100607114001800_ref16","doi-asserted-by":"publisher","first-page":"R351","DOI":"10.1088\/0031-9155\/53\/20\/R01","article-title":"Optically stimulated luminescence (OSL) dosimetry in medicine","volume":"53","author":"Yukihara","year":"2008","journal-title":"Phys Med Biol"},{"key":"2026100607114001800_ref17","doi-asserted-by":"publisher","first-page":"229","DOI":"10.14407\/jrpr.2016.41.3.229","article-title":"Fundamental study of nanoDot OSL dosimeters for entrance skin dose measurement in diagnostic x-ray examinations","volume":"41","author":"Okazaki","year":"2016","journal-title":"J Radiat Prot Res"},{"key":"2026100607114001800_ref18","volume-title":"Radiation Protection Instrumentation - Ambient and\/or Directional Dose Equivalent (Rate) Meters and\/or Monitors for Beta, X and Gamma Radiation - Part 1: Portable Workplace and Environmental Meters and Monitors. IEC 60846\u20131","author":"International Electrotechnical Commission","year":"2009"},{"key":"2026100607114001800_ref19"},{"key":"2026100607114001800_ref20","doi-asserted-by":"publisher","first-page":"2","DOI":"10.11269\/jjrsm.21.2","article-title":"Fundamental characteristics of a hybrid survey meter -measurement of scattered radiation","volume":"21","author":"Omori","year":"2022","journal-title":"Jpn J Radiat Saf Manag"},{"key":"2026100607114001800_ref21","doi-asserted-by":"publisher","first-page":"244","DOI":"10.6009\/jjrt.2016_JSRT_72.3.244","article-title":"Development of a lead-covered case for a wireless x-ray output analyzer to perform CT half-value layer measurements","volume":"72","author":"Akaishi","year":"2016","journal-title":"Jpn J Radiol Technol"},{"key":"2026100607114001800_ref22","doi-asserted-by":"publisher","journal-title":"ECR","DOI":"10.1594\/ecr2018\/C-0477"},{"key":"2026100607114001800_ref23","volume-title":"IEC 60601-2-44:2009+AMD1:2012+AMD2:2016 CSV. Medical Electrical Equipment\u2014Part 2-44: Particular Requirements for the Basic Safety and Essential Performance of X-Ray Equipment for Computed Tomography","author":"International Electrotechnical Commission","year":"2016"},{"key":"2026100607114001800_ref24","doi-asserted-by":"publisher","first-page":"158","DOI":"10.1007\/s12194-013-0246-x","article-title":"Evaluation of the effectiveness of X-ray protective aprons in experimental and practical fields","volume":"7","author":"Mori","year":"2014","journal-title":"Radiol Phys Technol"},{"key":"2026100607114001800_ref25","doi-asserted-by":"publisher","first-page":"102543","DOI":"10.1016\/j.ejmp.2023.102543","article-title":"Effectiveness of staff radiation protection devices for interventional cardiology procedures","volume":"107","author":"Christelle","year":"2023","journal-title":"Phys Med"},{"key":"2026100607114001800_ref26","doi-asserted-by":"publisher","first-page":"E687","DOI":"10.1002\/ccd.29894","article-title":"Evaluation of a suspended radiation protection system to reduce operator exposure in cardiology interventional procedures","volume":"98","author":"Federica","year":"2021","journal-title":"Catheter Cardiovasc Interv"},{"key":"2026100607114001800_ref27","doi-asserted-by":"publisher","first-page":"4270","DOI":"10.1118\/1.2786861","article-title":"Shielding properties of lead-free protective clothing and their impact on radiation doses","volume":"34","author":"Helmut","year":"2007","journal-title":"Med Phys"},{"key":"2026100607114001800_ref28","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1177\/0146645315575485","article-title":"Radiological protection in Cone Beam Computed Tomography (CBCT). ICRP Publication 129","volume":"44","author":"Rehani","year":"2015","journal-title":"Ann ICRP"}],"container-title":["Radiation Protection Dosimetry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/rpd\/article-pdf\/202\/16\/1354\/68781641\/ncag073.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/rpd\/article-pdf\/202\/16\/1354\/68781641\/ncag073.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T11:11:51Z","timestamp":1791285111000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/rpd\/article\/202\/16\/1354\/8734224"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,14]]},"references-count":28,"journal-issue":{"issue":"16","published-online":{"date-parts":[[2026,7,14]]},"published-print":{"date-parts":[[2026,10,6]]}},"URL":"https:\/\/doi.org\/10.1093\/rpd\/ncag073","relation":{},"ISSN":["0144-8420","1742-3406"],"issn-type":[{"value":"0144-8420","type":"print"},{"value":"1742-3406","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2026,10]]},"published":{"date-parts":[[2026,7,14]]}}}