{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,17]],"date-time":"2026-11-17T13:21:55Z","timestamp":1794921715637,"version":"4.9.1"},"reference-count":36,"publisher":"Oxford University Press (OUP)","issue":"19","license":[{"start":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T00:00:00Z","timestamp":1787702400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/pages\/standard-publication-reuse-rights"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,11,17]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Accurate evaluation of eye lens exposure during pediatric computed tomography (CT) examinations is essential for radiation protection because the lens is among the most radiosensitive organs in the human body. In this study, a scanner-specific Monte Carlo framework based on Geant4 (v11.02.p2) was developed to quantify slice-resolved absorbed dose to the eye lens and selected head organs in pediatric axial CT imaging. The CT system was modeled in detail, including X-ray spectra, bowtie filtration, beam collimation, and source geometry. Beam quality was tuned using half-value layer and lateral beam profile measurements. Model validation was performed through comparison with experimental computed tomography dose index ratios, ${\\text{CTDI}}_{\\text{air}}\/{\\text{CTDI}}_{w}$, for tube voltages between 80 and 140 kVp and collimations between 10 and 40 mm, showing agreement within 2%. Simulations using 10 pediatric voxel phantoms based on International Commission on Radiological Protection-143 reference models revealed a strong dependence of ocular dose on acquisition parameters and patient anatomy. Although absolute eye-lens dose differed substantially between the two acquisition configurations, normalization relative to brain dose showed that beam collimation altered the eye-to-brain dose ratio by only about 6%. However, reducing tube voltage from 140 to 80 kVp decreased eye lens dose by $\\sim $86% in newborn phantoms. The proposed framework enables detailed slice-resolved assessment of ocular exposure beyond conventional CTDI-based estimates and provides a robust tool for evaluating pediatric CT protocols and supporting optimization strategies aimed at improving radiation protection of radiosensitive tissues.<\/jats:p>","DOI":"10.1093\/rpd\/ncag097","type":"journal-article","created":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T12:05:21Z","timestamp":1785585921000},"page":"1616-1630","source":"Crossref","is-referenced-by-count":0,"title":["Slice-resolved ocular dosimetry in pediatric axial CT using a validated Geant4 Monte Carlo framework"],"prefix":"10.1093","volume":"202","author":[{"given":"Nouf","family":"Abuhadi","sequence":"first","affiliation":[{"name":"Diagnostic Radiography Technology Department, College of Nursing and Health Sciences, Jazan university, Al Maarefah Road , Ash Shati District Building Code 6265, P.O. Box 6809, Jazan 82817 - 2820, Kingdom of","place":["Saudi Arabia"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Omrane","family":"Kadri","sequence":"additional","affiliation":[{"name":"Research Laboratory on Energy and Matter for Nuclear Science Development (LR16CNSTN02), National Center for Nuclear Science and Technologies , Sidi Thabet Technopark 2020 Tunis,","place":["Tunisia"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kais","family":"Manai","sequence":"additional","affiliation":[{"name":"Laboratory of Condensed Matter Physics (LPMC), Faculty of Sciences of Tunis, El Manar Campus. University of Tunis El Manar , Tunis 2092,","place":["Tunisia"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2026,8,26]]},"reference":[{"key":"2026111708033269100_ref1","doi-asserted-by":"publisher","first-page":"3111","DOI":"10.1038\/s41591-023-02620-0","article-title":"Risk of hematological malignancies from CT radiation exposure in children, adolescents and young adults","volume":"29","author":"Bosch de Basea","year":"2023","journal-title":"Nat Med"},{"key":"2026111708033269100_ref2","doi-asserted-by":"crossref","DOI":"10.18356\/fd14587c-en","volume-title":"Sources, Effects and Risks of Ionizing Radiation, United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) 2013 Report, Volume II: Scientific Annex B - Effects of Radiation Exposure of Children","author":"United Nations Scientific Committee on the Effects of Atomic Radiation","year":"2014"},{"key":"2026111708033269100_ref3","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.icrp.2012.02.001","article-title":"ICRP publication 118: ICRP statement on tissue reactions and early and late effects of radiation in normal tissues and organs \u2014 threshold doses for tissue reactions in a radiation protection context","author":"Stewart","year":"2012","journal-title":"Annals of the ICRP"},{"key":"2026111708033269100_ref4","doi-asserted-by":"publisher","first-page":"151","DOI":"10.1007\/s00270-015-1207-z","article-title":"Radiation-induced cataractogenesis: a critical literature review for the interventional radiologist","volume":"39","author":"Seals","year":"2016","journal-title":"Cardiovasc Intervent Radiol"},{"key":"2026111708033269100_ref5","doi-asserted-by":"publisher","first-page":"311","DOI":"10.1148\/radiol.11101800","article-title":"CT dose index and patient dose: they are not the same thing","volume":"259","author":"McCollough","year":"2011","journal-title":"Radiology"},{"key":"2026111708033269100_ref6","doi-asserted-by":"publisher","first-page":"166","DOI":"10.1093\/rpd\/ncv074","article-title":"Evaluation of organ doses in adult and paediatric CT examinations based on Monte Carlo simulations and in-phantom dosimetry","volume":"165","author":"Fujii","year":"2015","journal-title":"Radiat Prot Dosim"},{"key":"2026111708033269100_ref7","doi-asserted-by":"publisher","first-page":"2154","DOI":"10.1118\/1.3117683","article-title":"A method to generate equivalent energy spectra and filtration models based on measurement for multidetector CT Monte Carlo dosimetry simulations","volume":"36","author":"Turner","year":"2009","journal-title":"Med Phys"},{"key":"2026111708033269100_ref8","doi-asserted-by":"publisher","first-page":"e13625","DOI":"10.1002\/acm2.13625","article-title":"Comparison of organ and effective dose estimations from different Monte Carlo simulation-based software methods in infant CT and comparison with direct phantom measurements","volume":"23","author":"Lawson","year":"2022","journal-title":"J Appl Clin Med Phys"},{"key":"2026111708033269100_ref9","doi-asserted-by":"publisher","first-page":"713","DOI":"10.1118\/1.596185","article-title":"Monte Carlo simulation of the scattered radiation distribution in diagnostic radiology","volume":"15","author":"Boone","year":"1988","journal-title":"Med Phys"},{"key":"2026111708033269100_ref10","doi-asserted-by":"publisher","first-page":"186","DOI":"10.1016\/j.nima.2016.06.125","article-title":"Recent developments in Geant4. Nuclear instruments and methods in physics research section a: accelerators, spectrometers, detectors and associated equipment","volume":"835","author":"Allison","year":"2016","journal-title":"Nucl Instrum Methods Phys Res A"},{"key":"2026111708033269100_ref11","doi-asserted-by":"publisher","first-page":"406","DOI":"10.1118\/1.3551990","article-title":"Experimental validation of a method characterizing bow tie filters in CT scanners using a real-time dose probe","volume":"38","author":"McKenney","year":"2011","journal-title":"Med Phys"},{"key":"2026111708033269100_ref12","volume-title":"Computed Tomography: Fundamentals, System Technology, Image Quality, Applications","author":"Kalender","year":"2011"},{"key":"2026111708033269100_ref13","doi-asserted-by":"publisher","first-page":"5439","DOI":"10.1002\/mp.15798","article-title":"Dose coefficients for organ dosimetry in tomosynthesis imaging of adults and pediatrics across diverse protocols","volume":"49","author":"Sharma","year":"2022","journal-title":"Med Phys"},{"key":"2026111708033269100_ref14","doi-asserted-by":"publisher","first-page":"111920","DOI":"10.1118\/1.4824918","article-title":"Dose equations for tube current modulation in CT scanning and the interpretation of the associated CTDI$_vol$","volume":"40","author":"Dixon","year":"2013","journal-title":"Med Phys"},{"key":"2026111708033269100_ref15","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1177\/0146645320915031","article-title":"ICRP publication 143: paediatric reference computational phantoms","volume":"49","author":"Bolch","year":"2020","journal-title":"Ann ICRP"},{"key":"2026111708033269100_ref16","doi-asserted-by":"publisher","first-page":"339","DOI":"10.1088\/0031-9155\/55\/2\/002","article-title":"The UF family of reference hybrid phantoms for computational radiation dosimetry","volume":"55","author":"Lee","year":"2009","journal-title":"Phys Med Biol"},{"key":"2026111708033269100_ref17","doi-asserted-by":"publisher","first-page":"4711","DOI":"10.1118\/1.4955438","article-title":"Technical note: SPEKTR 3.0-a computational tool for x-ray spectrum modeling and analysis","volume":"43","author":"Punnoose","year":"2016","journal-title":"Med Phys"},{"key":"2026111708033269100_ref18","doi-asserted-by":"publisher","first-page":"1340001","DOI":"10.1142\/s1793962313400011","article-title":"The Geant4 visualization system: a multi-driver graphics system","volume":"04","author":"John","year":"2013","journal-title":"Int J Model Simul Sci"},{"key":"2026111708033269100_ref19","volume-title":"Tables of X-Ray Mass Attenuation Coefficients and Mass Energy-Absorption Coefficients (version 1.4)","author":"Hubbell","year":"2004"},{"key":"2026111708033269100_ref20","doi-asserted-by":"publisher","first-page":"57","DOI":"10.1002\/mp.12024","article-title":"Direct and fast measurement of CT beam filter profiles with simultaneous geometrical calibration","volume":"44","author":"Yang","year":"2017","journal-title":"Med Phys"},{"key":"2026111708033269100_ref21","doi-asserted-by":"publisher","first-page":"271","DOI":"10.31661\/jbpe.v0i0.2012-1254","article-title":"A Monte Carlo platform for characterization of X-ray radiation dose in CT imaging","volume":"11","author":"Pakravan","year":"2012","journal-title":"J Biomed Phys Eng"},{"key":"2026111708033269100_ref22","doi-asserted-by":"publisher","first-page":"5243","DOI":"10.1088\/0031-9155\/59\/18\/5243","article-title":"Development of 1-year-old computational phantom and calculation of organ doses during CT scans using Monte Carlo simulation","volume":"59","author":"Pan","year":"2014","journal-title":"Phys Med Biol"},{"key":"2026111708033269100_ref23","article-title":"Paediatric computational reference phantoms. ICRP publication 143","author":"ICRP","year":"2020"},{"key":"2026111708033269100_ref24","doi-asserted-by":"publisher","first-page":"2583","DOI":"10.1088\/0031-9155\/52\/9\/017","article-title":"Estimating radiation doses from multidetector CT using Monte Carlo simulations: effects of different size voxelized patient models on magnitudes of organ and effective dose","volume":"52","author":"DeMarco","year":"2007","journal-title":"Phys Med Biol"},{"key":"2026111708033269100_ref25","doi-asserted-by":"publisher","first-page":"4517","DOI":"10.1088\/0031-9155\/60\/11\/4517","article-title":"New absorbed dose measurement with cylindrical water phantoms for multidetector CT","volume":"60","author":"Ohno","year":"2015","journal-title":"Phys Med Biol"},{"key":"2026111708033269100_ref26","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1177\/0146645317717209","article-title":"ICRP publication 135: diagnostic reference levels in medical imaging","volume":"46","author":"Va\u00f1\u00f3","year":"2017","journal-title":"Ann ICRP"},{"key":"2026111708033269100_ref27","doi-asserted-by":"publisher","first-page":"841","DOI":"10.1148\/radiol.12112365","article-title":"Size-specific dose estimates for adult patients at CT of the torso","volume":"265","author":"Christner","year":"2012","journal-title":"Radiology"},{"key":"2026111708033269100_ref28","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1016\/j.rcl.2008.10.006","article-title":"Strategies for reducing radiation dose in CT","volume":"47","author":"McCollough","year":"2009","journal-title":"Radiol Clin North Am"},{"key":"2026111708033269100_ref29","doi-asserted-by":"publisher","first-page":"1057","DOI":"10.1148\/rg.304095167","article-title":"Overranging at multisection CT: an underestimated source of excess radiation exposure","volume":"30","author":"Schilham","year":"2010","journal-title":"Radiographics"},{"key":"2026111708033269100_ref30","doi-asserted-by":"publisher","first-page":"2508","DOI":"10.1007\/s00247-025-06371-7","article-title":"A systematic review of radiation dose to the eye lens from pediatric brain computed tomography scans","volume":"55","author":"Perdomo","year":"2025","journal-title":"Pediatr Radiol"},{"key":"2026111708033269100_ref31","doi-asserted-by":"publisher","first-page":"1858","DOI":"10.1118\/1.2723885","article-title":"Organ and effective doses in pediatric patients undergoing helical multislice computed tomography examination","volume":"34","author":"Lee","year":"2007","journal-title":"Med Phys"},{"key":"2026111708033269100_ref32","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1007\/174_2012_542","article-title":"Radiation dose metrics and the effect of CT scan protocol parameters","volume-title":"Radiation Dose from Multidetector CT","author":"Edyvean","year":"2012"},{"key":"2026111708033269100_ref33","doi-asserted-by":"publisher","DOI":"10.37206\/97","article-title":"AAPM Task Group 23; CT dosimetry. Diagnostic Imaging Council CT Committee: the measurement, reporting, and management of radiation dose in CT. AAPM Report No, 96","author":"McCollough","year":"2008"},{"key":"2026111708033269100_ref34","doi-asserted-by":"publisher","first-page":"2129","DOI":"10.1118\/1.3693052","article-title":"Organ doses for reference pediatric and adolescent patients undergoing computed tomography estimated by Monte Carlo simulation","volume":"39","author":"Lee","year":"2012","journal-title":"Med Phys"},{"key":"2026111708033269100_ref35","doi-asserted-by":"publisher","first-page":"e67494","DOI":"10.7759\/cureus.67494","article-title":"Techniques and strategies to minimize radiation exposure in pediatric computed tomography (CT) abdominal examinations: a review","volume":"16","author":"Sayed","year":"2024","journal-title":"Cureus"},{"key":"2026111708033269100_ref36","doi-asserted-by":"publisher","first-page":"112471","DOI":"10.1016\/j.ejrad.2025.112471","article-title":"Over-scanning in pediatric head CT: prevalence, dosimetric impact, and associated cancer risks","volume":"194","author":"Zadeh","year":"2026","journal-title":"Eur J Radiol"}],"container-title":["Radiation Protection Dosimetry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/rpd\/article-pdf\/202\/19\/1616\/70811675\/ncag097.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/rpd\/article-pdf\/202\/19\/1616\/70811675\/ncag097.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,11,17]],"date-time":"2026-11-17T13:03:39Z","timestamp":1794920619000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/rpd\/article\/202\/19\/1616\/8771537"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,26]]},"references-count":36,"journal-issue":{"issue":"19","published-online":{"date-parts":[[2026,8,26]]},"published-print":{"date-parts":[[2026,11,17]]}},"URL":"https:\/\/doi.org\/10.1093\/rpd\/ncag097","relation":{},"ISSN":["0144-8420","1742-3406"],"issn-type":[{"value":"0144-8420","type":"print"},{"value":"1742-3406","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2026,11]]},"published":{"date-parts":[[2026,8,26]]}}}