{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,6]],"date-time":"2025-11-06T20:05:16Z","timestamp":1762459516065},"reference-count":44,"publisher":"Oxford University Press (OUP)","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2018,1,1]]},"DOI":"10.1093\/rpd\/ncx101","type":"journal-article","created":{"date-parts":[[2017,7,13]],"date-time":"2017-07-13T09:09:50Z","timestamp":1499936990000},"page":"213-222","source":"Crossref","is-referenced-by-count":6,"title":["PATIENT-SPECIFIC DOSIMETRY FOR PEDIATRIC IMAGING OF 99mTc-DIMERCAPTOSUCCINIC ACID WITH GATE MONTE CARLO CODE"],"prefix":"10.1093","volume":"178","author":[{"given":"Mahmoud","family":"Bagheri","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ali Asghar","family":"Parach","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Seid Kazem","family":"Razavi-Ratki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Reza","family":"Nafisi-Moghadam","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mohammad Ali","family":"Jelodari","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2017,8,5]]},"reference":[{"issue":"8","key":"key\n\t\t\t\t20180201030810_ncx101C1","first-page":"1331","article-title":"Biokinetic behavior of technetium-99m-DMSA in children","volume":"37","author":"Evans","year":"1996","journal-title":"J. Nucl. Med."},{"issue":"12","key":"key\n\t\t\t\t20180201030810_ncx101C2","first-page":"1955","article-title":"Diuretic MAG3 scintigraphy (F0) in acute pyelonephritis: regional parenchymal dysfunction and comparison with DMSA","volume":"41","author":"Sfakianakis","year":"2000","journal-title":"J. Nucl. Med."},{"issue":"1","key":"key\n\t\t\t\t20180201030810_ncx101C3","doi-asserted-by":"crossref","first-page":"159","DOI":"10.2967\/jnumed.112.110528","article-title":"Renal uptake of 99mTc-dimercaptosuccinic acid is dependent on normal proximal tubule receptor-mediated endocytosis","volume":"54","author":"Weyer","year":"2013","journal-title":"J. Nucl. Med."},{"issue":"1","key":"key\n\t\t\t\t20180201030810_ncx101C4","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1007\/s12519-012-0335-7","article-title":"Acute phase 99mTc-dimercaptosuccinic acid scan in infants with first episode of febrile urinary tract infection","volume":"8","author":"Printza","year":"2012","journal-title":"World J. Pediatr."},{"issue":"6","key":"key\n\t\t\t\t20180201030810_ncx101C5","doi-asserted-by":"crossref","first-page":"905","DOI":"10.2967\/jnumed.110.084202","article-title":"Nuclear medicine in the first year of life","volume":"52","author":"Treves","year":"2011","journal-title":"J. Nucl. Med."},{"issue":"3","key":"key\n\t\t\t\t20180201030810_ncx101C6","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1007\/BF02990025","article-title":"Technetium-99m-N, N-ethylenedicysteine and Tc-99m DMSA scintigraphy in the evaluation of renal parenchymal abnormalities in children","volume":"17","author":"Kibar","year":"2003","journal-title":"Ann. Nucl. Med."},{"issue":"12","key":"key\n\t\t\t\t20180201030810_ncx101C7","doi-asserted-by":"crossref","first-page":"1923","DOI":"10.2967\/jnumed.111.092221","article-title":"An approach for balancing diagnostic image quality with cancer risk: application to pediatric diagnostic imaging of 99mTc-dimercaptosuccinic acid","volume":"52","author":"Sgouros","year":"2011","journal-title":"J. Nucl. Med."},{"issue":"12","key":"key\n\t\t\t\t20180201030810_ncx101C8","doi-asserted-by":"crossref","first-page":"2269","DOI":"10.1007\/s00259-011-1904-z","article-title":"Biokinetics and dosimetry of commonly used radiopharmaceuticals in diagnostic nuclear medicine\u2014a review","volume":"38","author":"Eberlein","year":"2011","journal-title":"Eur. J. Nucl. Med. Mol. Imaging"},{"issue":"8","key":"key\n\t\t\t\t20180201030810_ncx101C9","first-page":"1336","article-title":"Radiation dosimetry of technetium-99m-DMSA in children","volume":"37","author":"Smith","year":"1996","journal-title":"J. Nucl. Med."},{"issue":"3","key":"key\n\t\t\t\t20180201030810_ncx101C10","doi-asserted-by":"crossref","first-page":"1288","DOI":"10.1118\/1.4907957","article-title":"Model\u2010based versus specific dosimetry in diagnostic context: comparison of three dosimetric approaches","volume":"42","author":"Marcatili","year":"2015","journal-title":"Med. Phys."},{"issue":"6","key":"key\n\t\t\t\t20180201030810_ncx101C11","doi-asserted-by":"crossref","first-page":"1008","DOI":"10.2967\/jnumed.106.038000","article-title":"Three-dimensional radiobiologic dosimetry: application of radiobiologic modeling to patient-specific 3-dimensional imaging-based internal dosimetry","volume":"48","author":"Prideaux","year":"2007","journal-title":"J. Nucl. Med."},{"issue":"9","key":"key\n\t\t\t\t20180201030810_ncx101C12","doi-asserted-by":"crossref","first-page":"926","DOI":"10.1097\/MNM.0b013e328355b6d5","article-title":"SPECT-CT in routine clinical practice: increase in patient radiation dose compared with SPECT alone","volume":"33","author":"Sharma","year":"2012","journal-title":"Nucl. Med. Commun."},{"issue":"4","key":"key\n\t\t\t\t20180201030810_ncx101C13","first-page":"266","article-title":"Estimation of radiation dosimetry for some common SPECT-CT exams","volume":"1","author":"Mhiri","year":"2012","journal-title":"Int. J. Biotechnol. Wellness Ind."},{"issue":"2","key":"key\n\t\t\t\t20180201030810_ncx101C14","first-page":"202","article-title":"Clinical oncologic applications of PET\/MRI: a new horizon","volume":"4","author":"Partovi","year":"2014","journal-title":"Am. J. Nucl. Med. Mol. Imaging"},{"issue":"1","key":"key\n\t\t\t\t20180201030810_ncx101C15","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1007\/s00259-008-1007-7","article-title":"Towards quantitative PET\/MRI: a review of MR-based attenuation correction techniques","volume":"36","author":"Hofmann","year":"2009","journal-title":"Eur. J. Nucl. Med. Mol. Imaging"},{"issue":"Suppl. 2","key":"key\n\t\t\t\t20180201030810_ncx101C16","doi-asserted-by":"crossref","first-page":"32S","DOI":"10.2967\/jnumed.113.129304","article-title":"Potential pediatric applications of PET\/MR","volume":"55","author":"Purz","year":"2014","journal-title":"J. Nucl. Med."},{"issue":"4","key":"key\n\t\t\t\t20180201030810_ncx101C17","doi-asserted-by":"crossref","first-page":"520","DOI":"10.2967\/jnumed.108.054726","article-title":"Tissue classification as a potential approach for attenuation correction in whole-body PET\/MRI: evaluation with PET\/CT data","volume":"50","author":"Martinez-M\u00f6ller","year":"2009","journal-title":"J. Nucl. Med."},{"issue":"6","key":"key\n\t\t\t\t20180201030810_ncx101C18","doi-asserted-by":"crossref","first-page":"977","DOI":"10.2967\/jnumed.111.098350","article-title":"Variable lung density consideration in attenuation correction of whole-body PET\/MRI","volume":"53","author":"Marshall","year":"2012","journal-title":"J. Nucl. Med."},{"issue":"9","key":"key\n\t\t\t\t20180201030810_ncx101C19","doi-asserted-by":"crossref","first-page":"1392","DOI":"10.2967\/jnumed.110.078949","article-title":"MRI-based attenuation correction for whole-body PET\/MRI: quantitative evaluation of segmentation-and atlas-based methods","volume":"52","author":"Hofmann","year":"2011","journal-title":"J. Nucl. Med."},{"issue":"11","key":"key\n\t\t\t\t20180201030810_ncx101C20","doi-asserted-by":"crossref","first-page":"1875","DOI":"10.2967\/jnumed.107.049353","article-title":"MRI-based attenuation correction for PET\/MRI: a novel approach combining pattern recognition and atlas registration","volume":"49","author":"Hofmann","year":"2008","journal-title":"J. Nucl. Med."},{"key":"key\n\t\t\t\t20180201030810_ncx101C21","volume-title":"MRI-Based Attenuation Correction in Emission Computed Tomography","author":"Marshall","year":"2012"},{"issue":"12","key":"key\n\t\t\t\t20180201030810_ncx101C22","doi-asserted-by":"crossref","first-page":"1878","DOI":"10.2967\/jnumed.112.104109","article-title":"Comparison of segmentation-based attenuation correction methods for PET\/MRI: evaluation of bone and liver standardized uptake value with oncologic PET\/CT data","volume":"53","author":"Kim","year":"2012","journal-title":"J. Nucl. Med."},{"issue":"6","key":"key\n\t\t\t\t20180201030810_ncx101C23","article-title":"A review of the use and potential of the GATE Monte Carlo simulation code for radiation therapy and dosimetry applications","volume":"41","author":"Sarrut","year":"2014","journal-title":"Med. Phys."},{"issue":"3","key":"key\n\t\t\t\t20180201030810_ncx101C24","doi-asserted-by":"crossref","first-page":"250","DOI":"10.1016\/S0168-9002(03)01368-8","article-title":"GEANT4\u2014a simulation toolkit","volume":"506","author":"Agostinelli","year":"2003","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"issue":"3","key":"key\n\t\t\t\t20180201030810_ncx101C25","doi-asserted-by":"crossref","first-page":"0341011","DOI":"10.1118\/1.4864237","article-title":"Toward an organ based dose prescription method for the improved accuracy of murine dose in orthovoltage x\u2010ray irradiators","volume":"41","author":"Belley","year":"2014","journal-title":"Med. Phys."},{"issue":"3","key":"key\n\t\t\t\t20180201030810_ncx101C26","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1007\/s00411-011-0370-0","article-title":"Assessment of MIRD data for internal dosimetry using the GATE Monte Carlo code","volume":"50","author":"Parach","year":"2011","journal-title":"Radiat. Environ. Biophys."},{"issue":"3","key":"key\n\t\t\t\t20180201030810_ncx101C27","doi-asserted-by":"crossref","first-page":"122","DOI":"10.3413\/Nukmed-0363-10-10","article-title":"A comparison between GATE4 results and MCNP4B published data for internal radiation dosimetry","volume":"50","author":"Parach","year":"2011","journal-title":"Nuklearmedizin"},{"issue":"10","key":"key\n\t\t\t\t20180201030810_ncx101C28","doi-asserted-by":"crossref","first-page":"5509","DOI":"10.1118\/1.3637493","article-title":"Paired organs\u2014should they be treated jointly or separately in internal dosimetry?","volume":"38","author":"Parach","year":"2011","journal-title":"Med. Phys."},{"issue":"1","key":"key\n\t\t\t\t20180201030810_ncx101C29","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1089\/cbr.2007.304","article-title":"Implementing dosimetry in GATE: dose-point kernel validation with GEANT4 4.8. 1","volume":"22","author":"Ferrer","year":"2007","journal-title":"Cancer Biother. Radiopharm."},{"issue":"3","key":"key\n\t\t\t\t20180201030810_ncx101C30","doi-asserted-by":"crossref","first-page":"1026","DOI":"10.1118\/1.2558115","article-title":"Monte Carlo simulations of absorbed dose in a mouse phantom from 18\u2010fluorine compounds","volume":"34","author":"Taschereau","year":"2007","journal-title":"Med. Phys."},{"issue":"2","key":"key\n\t\t\t\t20180201030810_ncx101C31","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1016\/j.nima.2006.08.049","article-title":"Use of the GATE Monte Carlo package for dosimetry applications","volume":"569","author":"Visvikis","year":"2006","journal-title":"Nucl. Instrum. Methods Phys. Res. A"},{"issue":"3","key":"key\n\t\t\t\t20180201030810_ncx101C32","doi-asserted-by":"crossref","first-page":"298","DOI":"10.1093\/rpd\/ncr411","article-title":"3D calculation of absorbed dose for 131I-targeted radiotherapy: a Monte Carlo study","volume":"150","author":"Saeedzadeh","year":"2011","journal-title":"Radiat. Prot. Dosimetry"},{"issue":"6","key":"key\n\t\t\t\t20180201030810_ncx101C33","doi-asserted-by":"crossref","first-page":"921","DOI":"10.2967\/jnumed.109.071571","article-title":"Quantitative accuracy of clinical 99mTc SPECT\/CT using ordered-subset expectation maximization with 3-dimensional resolution recovery, attenuation, and scatter correction","volume":"51","author":"Zeintl","year":"2010","journal-title":"J. Nucl. Med."},{"issue":"7","key":"key\n\t\t\t\t20180201030810_ncx101C34","doi-asserted-by":"crossref","first-page":"1119","DOI":"10.2967\/jnumed.113.133843","article-title":"Radiation dosimetry of 18F-FPEB in humans","volume":"55","author":"Kessler","year":"2014","journal-title":"J. Nucl. Med."},{"key":"key\n\t\t\t\t20180201030810_ncx101C35","doi-asserted-by":"crossref","first-page":"300","DOI":"10.1016\/j.apradiso.2013.09.006","article-title":"Determination of the biodistribution and dosimetry of 123 I-FP-CIT in male patients with suspected Parkinsonism or Lewy body dementia using planar and combined planar and SPECT\/CT imaging","volume":"82","author":"Sydoff","year":"2013","journal-title":"Appl. Radiat. Isot."},{"issue":"2","key":"key\n\t\t\t\t20180201030810_ncx101C36","doi-asserted-by":"crossref","first-page":"114","DOI":"10.4103\/1450-1147.174700","article-title":"A 3D Monte Carlo method for estimation of patient-specific internal organs absorbed dose for 99mTc-hynic-Tyr3-octreotide Imaging","volume":"15","author":"Momennezhad","year":"2016","journal-title":"World J. Nucl. Med."},{"issue":"2","key":"key\n\t\t\t\t20180201030810_ncx101C37","first-page":"37S","article-title":"MIRD pamphlet no. 16: techniques for quantitative radiopharmaceutical biodistribution data acquisition and analysis for use in human radiation dose estimates","volume":"40","author":"Siegel","year":"1999","journal-title":"J. Nucl. Med."},{"issue":"1\u20132","key":"key\n\t\t\t\t20180201030810_ncx101C38","doi-asserted-by":"crossref","first-page":"258","DOI":"10.1093\/rpd\/ncr329","article-title":"Patient-specific dosimetry in radionuclide therapy","volume":"147","author":"Lyra","year":"2011","journal-title":"Radiat. Prot. Dosimetry"},{"issue":"9","key":"key\n\t\t\t\t20180201030810_ncx101C39","doi-asserted-by":"crossref","first-page":"1474","DOI":"10.2967\/jnumed.111.088203","article-title":"Patient-specific radiation dosimetry of 99mTc-HYNIC-Tyr3-octreotide in neuroendocrine tumors","volume":"52","author":"Grimes","year":"2011","journal-title":"J. Nucl. Med."},{"issue":"5","key":"key\n\t\t\t\t20180201030810_ncx101C40","doi-asserted-by":"crossref","first-page":"1595","DOI":"10.1118\/1.3100265","article-title":"Comparison of organ residence time estimation methods for radioimmunotherapy dosimetry and treatment planning\u2014patient studies","volume":"36","author":"He","year":"2009","journal-title":"Med. Phys."},{"issue":"8","key":"key\n\t\t\t\t20180201030810_ncx101C41","doi-asserted-by":"crossref","first-page":"1310","DOI":"10.2967\/jnumed.111.100123","article-title":"MIRD pamphlet no. 23: quantitative SPECT for patient-specific 3-dimensional dosimetry in internal radionuclide therapy","volume":"53","author":"Dewaraja","year":"2012","journal-title":"J. Nucl. Med."},{"issue":"9","key":"key\n\t\t\t\t20180201030810_ncx101C42","doi-asserted-by":"crossref","first-page":"0925011","DOI":"10.1118\/1.4892606","article-title":"Comparison of internal dose estimates obtained using organ\u2010level, voxel S value, and Monte Carlo techniques","volume":"41","author":"Grimes","year":"2014","journal-title":"Med. Phys."},{"issue":"10","key":"key\n\t\t\t\t20180201030810_ncx101C43","doi-asserted-by":"crossref","first-page":"1439","DOI":"10.1007\/s00467-005-1925-6","article-title":"Evaluation of acute pyelonephritis with DMSA scans in children presenting after the age of 5 years","volume":"20","author":"Ataei","year":"2005","journal-title":"Pediatr. Nephrol."},{"issue":"9","key":"key\n\t\t\t\t20180201030810_ncx101C44","first-page":"1467","article-title":"Dosimetry in peptide radionuclide receptor therapy: a review","volume":"47","author":"Cremonesi","year":"2006","journal-title":"J. Nucl. Med."}],"container-title":["Radiation Protection Dosimetry"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/academic.oup.com\/rpd\/article-pdf\/178\/2\/213\/23736863\/ncx101.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2018,2,1]],"date-time":"2018-02-01T08:08:33Z","timestamp":1517472513000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/rpd\/article\/178\/2\/213\/4067736"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,8,5]]},"references-count":44,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2017,8,5]]},"published-print":{"date-parts":[[2018,1,1]]}},"URL":"https:\/\/doi.org\/10.1093\/rpd\/ncx101","relation":{},"ISSN":["0144-8420","1742-3406"],"issn-type":[{"value":"0144-8420","type":"print"},{"value":"1742-3406","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2018,1]]},"published":{"date-parts":[[2017,8,5]]}}}