{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,19]],"date-time":"2025-10-19T06:07:03Z","timestamp":1760854023240},"reference-count":23,"publisher":"Oxford University Press (OUP)","issue":"1","license":[{"start":{"date-parts":[[2018,11,14]],"date-time":"2018-11-14T00:00:00Z","timestamp":1542153600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019,7,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>The aim of this work was to investigate the optically-stimulated luminescence (OSL) properties of potassium chloride (KCl) and its potential use in radiation dosimetry. The optimal condition for OSL readout with blue light stimulation were designated using a commercially available Ris\u00f8 TL\/OSL reader. KCl was studied in three sample forms: crystals, powder and pellets. The following OSL characteristics were determined: signal reproducibility, OSL measurement-induced sensitivity changes, temperature dependence of OSL and signal stability over time. The results show a high reproducibility of KCl samples and strong sensitivity changes, which can be corrected for by using a test-dose. The long-term OSL studies confirmed the occurrence of both inverse fading and fading phenomena in KCl. In addition, a comparison with corresponding measurements using sodium chloride (NaCl) were carried out. Although it was confirmed that NaCl is more suitable for dosimetry, there might be benefits of combining NaCl with KCl for more accurate absorbed dose determinations.<\/jats:p>","DOI":"10.1093\/rpd\/ncy189","type":"journal-article","created":{"date-parts":[[2018,10,12]],"date-time":"2018-10-12T15:14:25Z","timestamp":1539357265000},"page":"90-97","source":"Crossref","is-referenced-by-count":13,"title":["OSL PROPERTIES IN VARIOUS FORMS OF KCl AND NaCl SAMPLES AFTER EXPOSURE TO IONIZING RADIATION"],"prefix":"10.1093","volume":"184","author":[{"given":"Renata","family":"Majgier","sequence":"first","affiliation":[{"name":"Institute of Physics, Faculty of Mathematics and Natural Sciences, Jan Dlugosz University, ul. Armii Krajowej 13\/15, Cz\u0119stochowa, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christopher L","family":"R\u00e4\u00e4f","sequence":"additional","affiliation":[{"name":"Medical Radiation Physics, Department of Translational Medicine, Lund University, Sk\u00e5ne University Hospital, Malm\u00f6, Sweden"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Arkadiusz","family":"Mandowski","sequence":"additional","affiliation":[{"name":"Institute of Physics, Faculty of Mathematics and Natural Sciences, Jan Dlugosz University, ul. Armii Krajowej 13\/15, Cz\u0119stochowa, Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christian","family":"Bernhardsson","sequence":"additional","affiliation":[{"name":"Medical Radiation Physics, Department of Translational Medicine, Lund University, Sk\u00e5ne University Hospital, Malm\u00f6, Sweden"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2018,11,14]]},"reference":[{"issue":"1","key":"2019072512301480200_ncy189C1","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1007\/s00411-008-0191-y","article-title":"Household salt as a retrospective dosemeter using optically stimulated luminescence","volume":"48","author":"Bernhardsson","year":"2009","journal-title":"Radiat. Environ. Biophys."},{"issue":"5","key":"2019072512301480200_ncy189C2","doi-asserted-by":"crossref","first-page":"717","DOI":"10.1016\/S1350-4487(00)00087-1","article-title":"OSL properties of NaCl relative to dating and dosimetry","volume":"32","author":"Bailey","year":"2000","journal-title":"Radiat. Meas."},{"key":"2019072512301480200_ncy189C3","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1016\/j.radmeas.2014.02.007","article-title":"Anomalous regeneration of OSL in sodium chloride\u2014Experiment and modeling","volume":"71","author":"Mandowski","year":"2014","journal-title":"Radiat. Meas."},{"key":"2019072512301480200_ncy189C4","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/j.radmeas.2013.03.021","article-title":"Investigation of regeneration effect of blue luminescence in NaCl using variable delay optically stimulated luminescence (VD-OSL)","volume":"56","author":"Biernacka","year":"2013","journal-title":"Radiat. Meas."},{"issue":"3","key":"2019072512301480200_ncy189C5","doi-asserted-by":"crossref","first-page":"234","DOI":"10.1016\/j.jlumin.2005.01.009","article-title":"Feasibility of optical dating using halite","volume":"114","author":"Zhang","year":"2005","journal-title":"J. Lumin."},{"key":"2019072512301480200_ncy189C6","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1016\/j.radmeas.2016.02.022","article-title":"Peculiarities of optically stimulated luminescence in halite","volume":"90","author":"Biernacka","year":"2016","journal-title":"Radiat. Meas."},{"key":"2019072512301480200_ncy189C7","doi-asserted-by":"crossref","first-page":"459","DOI":"10.1016\/j.radmeas.2017.01.016","article-title":"OSL properties of halite from K\u0142odawa salt mine","volume":"106","author":"Biernacka","year":"2017","journal-title":"Radiat. Meas."},{"issue":"1\u20134","key":"2019072512301480200_ncy189C8","doi-asserted-by":"crossref","first-page":"584","DOI":"10.1093\/rpd\/ncq430","article-title":"Using an optimised OSL single-aliquot regenerative-dose protocol for low-dose retrospective dosimetry on household salt","volume":"144","author":"Christiansson","year":"2011","journal-title":"Radiat. Prot. Dosim."},{"issue":"6","key":"2019072512301480200_ncy189C9","doi-asserted-by":"crossref","first-page":"631","DOI":"10.1097\/HP.0b013e31824108f5","article-title":"Optimizing a readout protocol for low dose retrospective OSL-dosimetry using household salt","volume":"102","author":"Christiansson","year":"2012","journal-title":"Health Phys."},{"issue":"3","key":"2019072512301480200_ncy189C10","doi-asserted-by":"crossref","first-page":"559","DOI":"10.1007\/s00411-014-0544-7","article-title":"Household salt for retrospective dose assessments using OSL: signal integrity and its dependence on containment, sample collection, and signal readout","volume":"53","author":"Christiansson","year":"2014","journal-title":"Radiat. Environ. Biophys."},{"issue":"1","key":"2019072512301480200_ncy189C11","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1093\/rpd\/ncq370","article-title":"NaCl as a retrospective and accident dosemeter","volume":"145","author":"Ekendahl","year":"2010","journal-title":"Radiat. Prot. Dosim."},{"key":"2019072512301480200_ncy189C12","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1016\/j.radmeas.2015.12.023","article-title":"A low-cost personal dosemeter based on optically stimulated luminescence (OSL) of common household salt (NaCl)","volume":"85","author":"Ekendahl","year":"2016","journal-title":"Radiat. Meas."},{"key":"2019072512301480200_ncy189C13","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1016\/j.radmeas.2018.09.001","article-title":"Physical and dosimetric properties of NaCl pellets made in-house for the use in prospective optically stimulated luminescence dosimetry applications","volume":"119","author":"Waldner","year":"2018","journal-title":"Radiat. Meas."},{"key":"2019072512301480200_ncy189C14","doi-asserted-by":"crossref","first-page":"242","DOI":"10.1016\/j.radmeas.2016.01.019","article-title":"Influence of thermal treatment on OSL regeneration in potassium chloride","volume":"90","author":"Majgier","year":"2016","journal-title":"Radiat. Meas."},{"key":"2019072512301480200_ncy189C15","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1016\/j.radmeas.2017.05.006","article-title":"Analysis of OSL decay characteristics for beta-irradiated potassium chloride samples","volume":"106","author":"Majgier","year":"2017","journal-title":"Radiat. Meas."},{"issue":"11","key":"2019072512301480200_ncy189C16","doi-asserted-by":"crossref","first-page":"7493","DOI":"10.1063\/1.356621","article-title":"Eu\u2010doped KCl phosphor crystals as a storage material for two\u2010dimensional ultraviolet\u2010ray or x\u2010ray imaging sensors","volume":"75","author":"Nanto","year":"1994","journal-title":"J. Appl. Phys."},{"issue":"8","key":"2019072512301480200_ncy189C17","doi-asserted-by":"crossref","first-page":"3748","DOI":"10.1118\/1.3171687","article-title":"Quantitative megavoltage radiation therapy dosimetry using the storage phosphor KCl: Eu2+","volume":"36","author":"Han","year":"2009","journal-title":"Med. Phys."},{"issue":"12","key":"2019072512301480200_ncy189C18","doi-asserted-by":"crossref","first-page":"4357","DOI":"10.1088\/0031-9155\/58\/12\/4357","article-title":"Performance of KCl: Eu2+ storage phosphor dosimeters for low-dose measurements","volume":"58","author":"Li","year":"2013","journal-title":"Phys. Med. Biol."},{"issue":"5","key":"2019072512301480200_ncy189C19","doi-asserted-by":"crossref","first-page":"523","DOI":"10.1016\/S1350-4487(00)00039-1","article-title":"Advances in luminescence instrument systems","volume":"32","author":"B\u00f8tter-Jensen","year":"2000","journal-title":"Radiat. Meas."},{"issue":"1\u20134","key":"2019072512301480200_ncy189C20","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1093\/oxfordjournals.rpd.a031680","article-title":"Optically stimulated luminescence sensitivity changes in quartz due to repeated use in single aliquot readout: experiments and computer simulations","volume":"65","author":"McKeever","year":"1996","journal-title":"Radiat. Prot. Dosim."},{"issue":"4","key":"2019072512301480200_ncy189C21","doi-asserted-by":"crossref","first-page":"535","DOI":"10.1016\/1350-4487(95)00006-Z","article-title":"Luminescence sensitivity changes in quartz as a result of annealing","volume":"24","author":"B\u00f8tter-Jensen","year":"1995","journal-title":"Radiat. Meas."},{"issue":"1\u20134","key":"2019072512301480200_ncy189C22","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1093\/oxfordjournals.rpd.a005825","article-title":"The theory of thermoluminescence with an arbitrary spatial distribution of traps","volume":"100","author":"Mandowski","year":"2002","journal-title":"Radiat. Prot. Dosim."},{"issue":"2","key":"2019072512301480200_ncy189C23","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1016\/j.radmeas.2007.10.009","article-title":"Semi-localized transitions model\u2014General formulation and classical limits","volume":"43","author":"Mandowski","year":"2008","journal-title":"Radiat. Meas."}],"container-title":["Radiation Protection Dosimetry"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/academic.oup.com\/rpd\/article-pdf\/184\/1\/90\/29001831\/ncy189.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,7,25]],"date-time":"2019-07-25T12:30:32Z","timestamp":1564057832000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/rpd\/article\/184\/1\/90\/5182330"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,11,14]]},"references-count":23,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2018,11,14]]},"published-print":{"date-parts":[[2019,7,1]]}},"URL":"https:\/\/doi.org\/10.1093\/rpd\/ncy189","relation":{},"ISSN":["0144-8420","1742-3406"],"issn-type":[{"value":"0144-8420","type":"print"},{"value":"1742-3406","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2019,7]]},"published":{"date-parts":[[2018,11,14]]}}}