{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2022,3,31]],"date-time":"2022-03-31T19:58:37Z","timestamp":1648756717569},"reference-count":26,"publisher":"Oxford University Press (OUP)","license":[{"start":{"date-parts":[[2019,2,26]],"date-time":"2019-02-26T00:00:00Z","timestamp":1551139200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"DOI":"10.1093\/rpd\/ncz020","type":"journal-article","created":{"date-parts":[[2019,1,31]],"date-time":"2019-01-31T12:34:25Z","timestamp":1548938065000},"source":"Crossref","is-referenced-by-count":1,"title":["MCNP SIMULATIONS WITH A PERSONALISED VOXEL PHANTOM TO VERIFY 131I CONTENT IN THYROID ESTIMATED BASED ON MEASUREMENTS WITH AN NaI(Tl) SPECTROMETER"],"prefix":"10.1093","author":[{"given":"Kotaro","family":"Tani","sequence":"first","affiliation":[{"name":"Department of Radiation Measurement and Dose Assessment, National Institutes for Quantum and Radiological Sciences and Technology, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba-city, Chiba, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Naoaki","family":"Kunishima","sequence":"additional","affiliation":[{"name":"Department of Radiation Measurement and Dose Assessment, National Institutes for Quantum and Radiological Sciences and Technology, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba-city, Chiba, Japan"},{"name":"Department of Radiology, Self-Defense Forces Central Hospital, 1-2-24 Ikejiri, Setagaya-ku, Tokyo, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yu","family":"Igarashi","sequence":"additional","affiliation":[{"name":"Department of Environment Systems, University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa-City, Chiba, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eunjoo","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Radiation Measurement and Dose Assessment, National Institutes for Quantum and Radiological Sciences and Technology, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba-city, Chiba, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takeshi","family":"Iimoto","sequence":"additional","affiliation":[{"name":"Department of Environment Systems, University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa-City, Chiba, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Osamu","family":"Kurihara","sequence":"additional","affiliation":[{"name":"Department of Radiation Measurement and Dose Assessment, National Institutes for Quantum and Radiological Sciences and Technology, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba-city, Chiba, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2019,2,26]]},"reference":[{"key":"key\n\t\t\t\t2019022606005636900_ncz020C1","doi-asserted-by":"crossref","first-page":"507","DOI":"10.1038\/srep00507","article-title":"Thyroid doses for evacuees from the Fukushima nuclear accident","volume":"2","author":"Tokonami","year":"2012","journal-title":"Sci. Rep."},{"key":"key\n\t\t\t\t2019022606005636900_ncz020C2","doi-asserted-by":"crossref","first-page":"17","DOI":"10.5453\/jhps.47.17","article-title":"Results of simplified survey for thyroid internal exposure of children in Fukushima and other surveys","volume":"47","author":"Fukushima","year":"2012","journal-title":"Jpn. J. Health Phys."},{"issue":"2","key":"key\n\t\t\t\t2019022606005636900_ncz020C3","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1080\/00223131.2013.757449","article-title":"Measurements of 131I in the thyroids of employees involved in the Fukushima Daiichi nuclear power station accident","volume":"50","author":"Kurihara","year":"2013","journal-title":"J. Nucl. Sci. Tech."},{"key":"key\n\t\t\t\t2019022606005636900_ncz020C4","author":"Nakano"},{"key":"key\n\t\t\t\t2019022606005636900_ncz020C5","doi-asserted-by":"crossref","first-page":"420","DOI":"10.1093\/rpd\/ncw002","article-title":"Internal doses of three persons staying 110 km south of the Fukushima Daiichi nuclear power station during the arrival of radioactive plumes based on direct measurements","volume":"170","author":"Kurihara","year":"2016","journal-title":"Radiat. Prot. Dosim."},{"key":"key\n\t\t\t\t2019022606005636900_ncz020C6","author":"International Commission on Radiation Units and Measurements"},{"key":"key\n\t\t\t\t2019022606005636900_ncz020C7","article-title":"Thyroid radioiodine uptake measurements: a standard system for universal intercalibration","volume":"19","author":"Brucer","year":"1959","journal-title":"United States Atomic Energy Commission Report ORINS"},{"key":"key\n\t\t\t\t2019022606005636900_ncz020C8","author":"American National Standards Institute","year":"1973"},{"key":"key\n\t\t\t\t2019022606005636900_ncz020C9","author":"International Commission on Radiological Protection","year":"1993"},{"issue":"1","key":"key\n\t\t\t\t2019022606005636900_ncz020C10","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1093\/rpd\/ncr405","article-title":"The contemporary JAEA Japanese voxel phantom","volume":"149","author":"Sato","year":"2011","journal-title":"Radiat. Prot. Dosim."},{"issue":"3","key":"key\n\t\t\t\t2019022606005636900_ncz020C11","doi-asserted-by":"crossref","first-page":"300","DOI":"10.1093\/rpd\/nct014","article-title":"Assessing internal contamination after the detonation of a radiological dispersion device using a 2\u00d72-inch sodium iodide detector","volume":"155","author":"Dewji","year":"2013","journal-title":"Radiat. Prot. Dosim."},{"issue":"6","key":"key\n\t\t\t\t2019022606005636900_ncz020C12","doi-asserted-by":"crossref","first-page":"612","DOI":"10.1097\/HP.0000000000000496","article-title":"Use of transportable radiation detection instruments to assess internal contamination from intakes of radionuclides part I: field tests and Monte Carlo simulations","volume":"110","author":"Anigstein","year":"2016","journal-title":"Health Phys."},{"issue":"6","key":"key\n\t\t\t\t2019022606005636900_ncz020C13","doi-asserted-by":"crossref","first-page":"542","DOI":"10.1097\/HP.0000000000000572","article-title":"Use of transportable radiation detection instruments to assess internal contamination from intakes of radionuclides part II: calibration factors and ICAT computer program","volume":"111","author":"Anigstein","year":"2016","journal-title":"Health Phys."},{"key":"key\n\t\t\t\t2019022606005636900_ncz020C14","first-page":"36","article-title":"Image processing with ImageJ","volume":"11","author":"Abramoff","year":"2004","journal-title":"Biophoto. Int."},{"key":"key\n\t\t\t\t2019022606005636900_ncz020C15","first-page":"161","article-title":"Monte Carlo based voxel phantoms for in vivo internal dosimetry","volume":"125","author":"G\u00f3mez-Ros","year":"2007","journal-title":"Radiat. Prot. Dosim."},{"key":"key\n\t\t\t\t2019022606005636900_ncz020C16","doi-asserted-by":"crossref","DOI":"10.2172\/1339944","volume-title":"Development of PIMAL: mathematical phantom with moving arms and legs","author":"Akkurt","year":"2007"},{"key":"key\n\t\t\t\t2019022606005636900_ncz020C17","author":"Pelowitz","year":"2011"},{"key":"key\n\t\t\t\t2019022606005636900_ncz020C18","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1016\/j.radphyschem.2016.03.020","article-title":"A study of the effect of Al 2 O 3 reflector on response function of NaI(Tl) detector","volume":"125","author":"Tam","year":"2016","journal-title":"Radiat. Phys. Chem."},{"key":"key\n\t\t\t\t2019022606005636900_ncz020C19","doi-asserted-by":"crossref","first-page":"364","DOI":"10.1093\/rpd\/ncv509","article-title":"Numerical assessment of 131 I deposited in thyroid for non-standard situations","volume":"170","author":"Moraleda","year":"2015","journal-title":"Radiat. Prot. Dosim."},{"key":"key\n\t\t\t\t2019022606005636900_ncz020C20","doi-asserted-by":"crossref","first-page":"635","DOI":"10.1088\/1361-6498\/aa714d","article-title":"Estimation of counting efficiencies of a portable NaI detector using Monte Carlo simulation for thyroid measurement following nuclear accidents","volume":"37","author":"Ha","year":"2017","journal-title":"J. Radiol. Prot."},{"key":"key\n\t\t\t\t2019022606005636900_ncz020C21","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1093\/rpd\/ncw001","article-title":"Numerical simulation of direct measurement to determine thyroid 131I content of two TEPCO workers considering individual tissue thickness","volume":"170","author":"Tani","year":"2016","journal-title":"Radiat. Prot. Dosim."},{"key":"key\n\t\t\t\t2019022606005636900_ncz020C22","author":"Kunishima"},{"key":"key\n\t\t\t\t2019022606005636900_ncz020C23","author":"Beaumont"},{"key":"key\n\t\t\t\t2019022606005636900_ncz020C24","author":"Karachalias"},{"key":"key\n\t\t\t\t2019022606005636900_ncz020C25","author":"Etherington"},{"key":"key\n\t\t\t\t2019022606005636900_ncz020C26","author":"SHAMISEN Consortium"}],"container-title":["Radiation Protection Dosimetry"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/academic.oup.com\/rpd\/advance-article-pdf\/doi\/10.1093\/rpd\/ncz020\/27983906\/ncz020.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,11,15]],"date-time":"2019-11-15T20:11:51Z","timestamp":1573848711000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/rpd\/advance-article\/doi\/10.1093\/rpd\/ncz020\/5365234"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,2,26]]},"references-count":26,"URL":"https:\/\/doi.org\/10.1093\/rpd\/ncz020","relation":{},"ISSN":["0144-8420","1742-3406"],"issn-type":[{"value":"0144-8420","type":"print"},{"value":"1742-3406","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,2,26]]}}}