{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2022,3,31]],"date-time":"2022-03-31T11:02:01Z","timestamp":1648724521914},"reference-count":15,"publisher":"Oxford University Press (OUP)","issue":"4","license":[{"start":{"date-parts":[[2019,4,23]],"date-time":"2019-04-23T00:00:00Z","timestamp":1555977600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"}],"funder":[{"name":"Malaysian Ministry of Education and Universiti Teknologi Malaysia","award":["17H79","17H19","18H68","03G72"],"award-info":[{"award-number":["17H79","17H19","18H68","03G72"]}]},{"name":"National Medical Research Register","award":["NMRR-17-2092-34972"],"award-info":[{"award-number":["NMRR-17-2092-34972"]}]},{"name":"Malaysian Ethical Research Committee","award":["MREC(5)KKM\/NIHSEC\/P17-1524"],"award-info":[{"award-number":["MREC(5)KKM\/NIHSEC\/P17-1524"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019,12,31]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>Long exposure to radiation from fluoroscopy-guided interventions (FGIs) can be detrimental to both patients and radiologists. The effective doses received by the interventional radiology staff after performing 230 FGIs in a year were assessed by using double dosimetry and five various algorithms. The Shapiro\u2013Wilk test revealed normally-distributed data (p &amp;lt; 0.01), while the significant correlation coefficients between the effective doses ranged between 0.88 and 1.00. As for the Bland\u2013Altman analysis, both Niklason and Boetticher algorithms strongly supported the absence of statistical significance between the estimated effective doses. This portrays that the occupational doses received by the interventional radiology staff during FGIs fall within the acceptable limit regardless of the varied algorithms applied. In short, the Niklason and Boetticher algorithms appeared to be the more interchangeable ones for effective evaluation of doses. This is in view of their strong mutual correlations and excellent agreement.<\/jats:p>","DOI":"10.1093\/rpd\/ncz051","type":"journal-article","created":{"date-parts":[[2019,3,20]],"date-time":"2019-03-20T12:11:33Z","timestamp":1553083893000},"page":"462-468","source":"Crossref","is-referenced-by-count":0,"title":["ASSESSMENT ON THE INTERCHANGEABILITY OF PERSONAL EFFECTIVE DOSE ALGORITHMS IN FLUOROSCOPY-GUIDED INTERVENTIONS USING BLAND-ALTMAN ANALYSIS"],"prefix":"10.1093","volume":"186","author":[{"given":"Asmah","family":"Bohari","sequence":"first","affiliation":[{"name":"Department of Physics, Faculty of Science, Universiti Teknologi Malaysia, 81310 Johor, Malaysia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Suhairul","family":"Hashim","sequence":"first","affiliation":[{"name":"Department of Physics, Faculty of Science, Universiti Teknologi Malaysia, 81310 Johor, Malaysia"},{"name":"Centre for Sustainable Nanomaterials (CSNano), Ibnu Sina Institute for Scientific and Industrial Research (ISI-SIR), Universiti Teknologi Malaysia, 81310 Johor, Malaysia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sib Krishna","family":"Ghoshal","sequence":"first","affiliation":[{"name":"Department of Physics, Faculty of Science, Universiti Teknologi Malaysia, 81310 Johor, Malaysia"},{"name":"Centre for Sustainable Nanomaterials (CSNano), Ibnu Sina Institute for Scientific and Industrial Research (ISI-SIR), Universiti Teknologi Malaysia, 81310 Johor, Malaysia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Siti Norsyafiqah","family":"Mohd Mustafa","sequence":"first","affiliation":[{"name":"Department of Radiology, Institut Kanser Negara, 62250 Putrajaya, Malaysia"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2019,4,23]]},"reference":[{"key":"2020040515251534100_ncz051C1","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1097\/HP.0000000000000674","article-title":"Appropriate use of effective dose in radiation protection and risk assessment","volume":"113","author":"Fisher","year":"2017","journal-title":"Health Phys."},{"key":"2020040515251534100_ncz051C2","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1093\/rpd\/ncn239","article-title":"Comparison of double dosimetry algorithms for estimating the effective dose in occupational dosimetry of interventional radiology staff","volume":"131","author":"J\u00e4rvinen","year":"2008","journal-title":"Radiat. Prot. Dosim."},{"key":"2020040515251534100_ncz051C3","doi-asserted-by":"crossref","first-page":"170","DOI":"10.1080\/02841850802616745","article-title":"Effect of radiation monitoring method and formula differences on estimated physician dose during percutaneous coronary intervention","volume":"50","author":"Chida","year":"2009","journal-title":"Acta Radiol."},{"key":"2020040515251534100_ncz051C4","doi-asserted-by":"crossref","first-page":"647","DOI":"10.1166\/jmihi.2015.1438","article-title":"Comparison of five developed algorithms to estimate staff effective dose in interventional cardiology: are they interchangeable?","volume":"5","author":"Moladoust","year":"2015","journal-title":"J. Med. Imaging Health Inform."},{"key":"2020040515251534100_ncz051C5","doi-asserted-by":"crossref","first-page":"321","DOI":"10.1093\/rpd\/ncn148","article-title":"Double-dosimetry algorithm for workers in interventional radiology","volume":"129","author":"Clerinx","year":"2008","journal-title":"Radiat. Prot. Dosim."},{"key":"2020040515251534100_ncz051C6","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1093\/oxfordjournals.rpd.a006490","article-title":"Staff dosimetry in interventional cardiology","volume":"94","author":"Padovani","year":"2001","journal-title":"Radiat. Prot. Dosim."},{"key":"2020040515251534100_ncz051C7","doi-asserted-by":"crossref","first-page":"611","DOI":"10.1097\/00004032-199412000-00003","article-title":"The estimation of occupational effective dose in diagnostic radiology with two dosimeters","volume":"67","author":"Niklason","year":"1994","journal-title":"Health Phys."},{"key":"2020040515251534100_ncz051C8","author":"Ministry of Health Malaysia","year":"2016"},{"key":"2020040515251534100_ncz051C9","doi-asserted-by":"crossref","first-page":"800","DOI":"10.1097\/HP.0b013e3181e850da","article-title":"An analytic approach to double dosimetry algorithms in occupational dosimetry using energy dependent organ dose conversion coefficients","volume":"99","author":"von Boetticher","year":"2010","journal-title":"Health Phys."},{"key":"2020040515251534100_ncz051C10","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1016\/j.radmeas.2013.01.023","article-title":"A survey on radiation exposure of primary operators from interventional X-ray procedures","volume":"55","author":"Kong","year":"2013","journal-title":"Radiat. Meas."},{"key":"2020040515251534100_ncz051C11","author":"ICRP 103","year":"2007"},{"key":"2020040515251534100_ncz051C12","author":"ICRP 60","year":"1991"},{"key":"2020040515251534100_ncz051C13","doi-asserted-by":"crossref","first-page":"622","DOI":"10.1097\/01.HP.0000363843.01041.99","article-title":"Cardiac catheterization: Impact of face and neck shielding on new estimates of effective dose","volume":"97","author":"von Boetticher","year":"2009","journal-title":"Health Phys."},{"key":"2020040515251534100_ncz051C14","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1016\/j.tjem.2018.09.001","article-title":"Bland-Altman analysis: a paradigm to understand correlation and agreement","volume":"18","author":"Do\u011fan","year":"2018","journal-title":"Turk. J. Emerg. Med."},{"key":"2020040515251534100_ncz051C15","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1093\/rpd\/ncx081","article-title":"The challenges in the estimation of the effective dose when wearing radioprotective garments","volume":"178","author":"Vargas","year":"2018","journal-title":"Radiat. Prot. Dosim."}],"container-title":["Radiation Protection Dosimetry"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/academic.oup.com\/rpd\/article-pdf\/186\/4\/462\/32994029\/ncz051.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/academic.oup.com\/rpd\/article-pdf\/186\/4\/462\/32994029\/ncz051.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,4,5]],"date-time":"2020-04-05T19:25:30Z","timestamp":1586114730000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/rpd\/article\/186\/4\/462\/5476794"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,4,23]]},"references-count":15,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2019,4,23]]},"published-print":{"date-parts":[[2019,12,31]]}},"URL":"https:\/\/doi.org\/10.1093\/rpd\/ncz051","relation":{},"ISSN":["0144-8420","1742-3406"],"issn-type":[{"value":"0144-8420","type":"print"},{"value":"1742-3406","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2019,12]]},"published":{"date-parts":[[2019,4,23]]}}}