{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,17]],"date-time":"2025-11-17T14:21:18Z","timestamp":1763389278396},"reference-count":24,"publisher":"Oxford University Press (OUP)","issue":"3","license":[{"start":{"date-parts":[[2019,12,27]],"date-time":"2019-12-27T00:00:00Z","timestamp":1577404800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2020,6,24]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>The aim of the study was to estimate organ dose rate reduction to a female anthropomorphic phantom, which simulated the cardiologist, during percutaneous coronary interventions (PCI) when the patient\u2019s arm support was covered with 0.4-mm lead foil. Organ dose rates were determined using five radiation detectors inserted into the left eye, left thyroid, left breast, left liver lobe and uterus of the phantom. A male anthropomorphic phantom was placed on the examination table of an angiography system. Heart images of the patient phantom were acquired under 10 gantry angulations typical for PCI. The lead-covered arm support did not interfere with any of the cardiac images. The median organ dose rate reductions to the left eye, left thyroid, left breast, left liver lobe and uterus were 7.8, 36.0, 28.8, 35.7 and 33.5%, respectively. The lead-covered arm support substantially reduced scattered radiation to the female cardiologist without interfering with clinical environments.<\/jats:p>","DOI":"10.1093\/rpd\/ncz292","type":"journal-article","created":{"date-parts":[[2019,12,6]],"date-time":"2019-12-06T12:37:27Z","timestamp":1575635847000},"page":"340-349","source":"Crossref","is-referenced-by-count":7,"title":["COVERING THE PATIENT\u2019S ARM SUPPORT IN LEAD REDUCED THE RADIATION DOSE RATE TO THE CARDIOLOGISTS DURING PERCUTANEOUS CORONARY INTERVENTIONS: A PHANTOM STUDY"],"prefix":"10.1093","volume":"188","author":[{"given":"Atsushi","family":"Fukuda","sequence":"first","affiliation":[{"name":"Preparing Section for New Faculty of Medical Science, Fukushima Medical University, 1 Hikarigaoka, Fukushima 960-1295, Japan"},{"name":"Division of Diagnostic Medical Physics, Department of Radiology, Virginia Commonwealth University Medical Center, 1300 East Marshall Street, Richmond, VA 23298-0615, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pei-Jan Paul","family":"Lin","sequence":"first","affiliation":[{"name":"Division of Diagnostic Medical Physics, Department of Radiology, Virginia Commonwealth University Medical Center, 1300 East Marshall Street, Richmond, VA 23298-0615, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2019,12,27]]},"reference":[{"issue":"20","key":"2020062503234429800_ref1","doi-asserted-by":"publisher","first-page":"2017","DOI":"10.1016\/j.jacc.2012.08.966","article-title":"A contemporary view of diagnostic cardiac catheterization and percutaneous coronary intervention in the United States: a report from the CathPCI Registry of the National Cardiovascular Data Registry, 2010 through June 2011","volume":"60","author":"Dehmer","year":"2012","journal-title":"J. Am. Coll. Cardiol"},{"issue":"15","key":"2020062503234429800_ref2","doi-asserted-by":"publisher","first-page":"1611","DOI":"10.1016\/j.jacc.2006.12.040","article-title":"Trends in outcomes after percutaneous coronary intervention for chronic total occlusions: a 25-year experience from the Mayo Clinic","volume":"49","author":"Prasad","year":"2007","journal-title":"J. Am. Coll. Cardiol."},{"issue":"1","key":"2020062503234429800_ref3","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1253\/circj.70.44","article-title":"Radiation exposure to patient's skin during percutaneous coronary intervention for various lesions, including chronic total occlusion","volume":"70","author":"Suzuki","year":"2006","journal-title":"Circ. J."},{"issue":"3","key":"2020062503234429800_ref4","doi-asserted-by":"publisher","first-page":"336","DOI":"10.1016\/j.jcin.2010.10.014","article-title":"Clinical determinants of radiation dose in percutaneous coronary interventional procedures: influence of patient size, procedure complexity, and performing physician","volume":"4","author":"Fetterly","year":"2011","journal-title":"JACC. Cardiovasc. Interv"},{"issue":"5","key":"2020062503234429800_ref5","doi-asserted-by":"publisher","first-page":"501","DOI":"10.1161\/CIRCINTERVENTIONS.113.000220","article-title":"Clinical and procedural characteristics associated with higher radiation exposure during percutaneous coronary interventions and coronary angiography","volume":"6","author":"Delewi","year":"2013","journal-title":"Circ. Cardiovasc. Interv."},{"issue":"4","key":"2020062503234429800_ref6","doi-asserted-by":"publisher","first-page":"409","DOI":"10.1007\/s00246-008-9375-0","article-title":"Staff radiation doses in interventional cardiology: correlation with patient exposure","volume":"30","author":"Vano","year":"2009","journal-title":"Pediatr. Cardiol."},{"key":"2020062503234429800_ref7","first-page":"998","article-title":"Somatic DNA damage in interventional cardiologists: a case-control study","author":"Andreassi","year":"2005"},{"issue":"9","key":"2020062503234429800_ref8","doi-asserted-by":"publisher","first-page":"1368","DOI":"10.1016\/j.amjcard.2012.12.060","article-title":"Brain and neck tumors among physicians performing interventional procedures","volume":"111","author":"Roguin","year":"2013","journal-title":"Am. J. Cardiol."},{"key":"2020062503234429800_ref9","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.icrp.2012.09.001","article-title":"International Commission on Radiological Protection. ICRP publication 120: Radiological protection in cardiology","author":"Cousins","year":"2013"},{"issue":"1","key":"2020062503234429800_ref10","doi-asserted-by":"crossref","first-page":"12","DOI":"10.2174\/1573403X11666150407110849","article-title":"Reducing radiation in chronic total occlusion percutaneous coronary interventions","volume":"12","author":"Pavlidis","year":"2016","journal-title":"Curr. Cardiol. Rev."},{"key":"2020062503234429800_ref11","volume-title":"Medical Electrical Equipment: Part 2-43 Particular Requirements for the Basic Safety and Essential Performance of X Ray Equipment for Interventional Procedures (IEC 60601-2-43)","author":"International Electrotechnical Commission","year":"2010","edition":"second"},{"key":"2020062503234429800_ref12","volume-title":"Report of the Task Group on Reference Man","author":"International Commission on Radiological Protection","year":"1975"},{"issue":"1","key":"2020062503234429800_ref13","article-title":"Phantoms and computational models in therapy, diagnosis and protection. ICRU Report 48","volume":"25","author":"International Commission on Radiation Units and Measurements","year":"1992","journal-title":"J. ICRU."},{"key":"2020062503234429800_ref14","volume-title":"User Guide of Adult Female Phantom (Model 702)","author":"Computerized Imaging Reference Systems (CIRS)","year":"2010"},{"key":"2020062503234429800_ref15","volume-title":"CT Dose Profiler User's Manual","author":"RTI Electronics","year":"2014"},{"issue":"2","key":"2020062503234429800_ref16","doi-asserted-by":"publisher","first-page":"316","DOI":"10.1007\/s12194-014-0269-y","article-title":"Differences in behavior of tube current modulation techniques for thoracic CT examinations between male and female anthropomorphic phantoms","volume":"7","author":"Matsubara","year":"2014","journal-title":"Radiol. Phys. Technol"},{"issue":"1\u20132","key":"2020062503234429800_ref17","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.icrp.2012.02.001","article-title":"ICRP publication 118: ICRP statement on tissue reactions and early and late effects of radiation in normal tissues and organs--threshold doses for tissue reactions in a radiation protection context","volume":"41","author":"International Commission on Radiological Protection","year":"2012","journal-title":"Ann. ICRP"},{"issue":"1","key":"2020062503234429800_ref18","doi-asserted-by":"publisher","first-page":"569","DOI":"10.1038\/s41598-017-00556-3","article-title":"Occupational eye dose in interventional cardiology procedures","volume":"7","author":"Haga","year":"2017","journal-title":"Sci. Rep"},{"issue":"6","key":"2020062503234429800_ref19","doi-asserted-by":"publisher","first-page":"622","DOI":"10.1097\/01.HP.0000363843.01041.99","article-title":"Cardiac catheterization: impact of face and neck shielding on new estimates of effective dose","volume":"97","author":"von Boetticher","year":"2009","journal-title":"Health. Phys"},{"key":"2020062503234429800_ref20","volume-title":"Risk to the thyroid from ionizing radiation","author":"National Council on Radiation Protection and Measurements","year":"2008"},{"issue":"6","key":"2020062503234429800_ref21","doi-asserted-by":"publisher","first-page":"877","DOI":"10.1667\/RR1953.1","article-title":"Non-malignant thyroid diseases after a wide range of radiation exposures","volume":"174","author":"Ron","year":"2010","journal-title":"Radiat. Res."},{"issue":"2-4","key":"2020062503234429800_ref22","first-page":"1","article-title":"The 2007 recommendations of the international commission on radiological protection. ICRP publication 103","volume":"37","author":"International Commission on Radiological Protection","year":"2007","journal-title":"Ann. ICRP"},{"key":"2020062503234429800_ref23","volume-title":"ICRU report 44: tissue substitutes in radiation dosimetry and measurement","author":"International Commission on Radiation Units and Measurements","year":"1989"},{"issue":"2","key":"2020062503234429800_ref24","doi-asserted-by":"publisher","first-page":"188","DOI":"10.1016\/j.amjcard.2016.04.045","article-title":"Radiation exposure of the operator during coronary interventions (from the RADIO Study)","volume":"118","author":"Kallinikou","year":"2016","journal-title":"Am. J. Cardiol."}],"container-title":["Radiation Protection Dosimetry"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/academic.oup.com\/rpd\/article-pdf\/188\/3\/340\/33423015\/ncz292.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/academic.oup.com\/rpd\/article-pdf\/188\/3\/340\/33423015\/ncz292.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,6,25]],"date-time":"2020-06-25T07:23:53Z","timestamp":1593069833000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/rpd\/article\/188\/3\/340\/5681344"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,12,27]]},"references-count":24,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2019,12,27]]},"published-print":{"date-parts":[[2020,6,24]]}},"URL":"https:\/\/doi.org\/10.1093\/rpd\/ncz292","relation":{},"ISSN":["0144-8420","1742-3406"],"issn-type":[{"value":"0144-8420","type":"print"},{"value":"1742-3406","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2020,3]]},"published":{"date-parts":[[2019,12,27]]}}}