{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,13]],"date-time":"2026-05-13T20:18:51Z","timestamp":1778703531485,"version":"3.51.4"},"reference-count":17,"publisher":"Oxford University Press (OUP)","issue":"3","license":[{"start":{"date-parts":[[2025,9,13]],"date-time":"2025-09-13T00:00:00Z","timestamp":1757721600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,3,11]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Study objectives<\/jats:title>\n                    <jats:p>To determine the accuracy of transcutaneous carbon dioxide measurements using SenTec tcPCO2 during adult polysomnography (PSG) compared to arterial PCO2.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>In consecutive patients having PSG with transcutaneous CO2 (tcPCO2) monitoring using a SenTec monitor, arterial blood gas samples were taken at the beginning and at the end of each sleep study. tcPCO2 measurements recorded at 0, 60, and 120\u00a0s after arterial sampling was determined in 51 participants who underwent PSG with tcPCO2 monitoring at the Austin Health Sleep Laboratory (Heidelberg, VIC, Australia) during the period 01\/05\/22\u201310\/06\/22. The mean of differences between arterial carbon dioxide tension (PaCO2) and the predicted value based on tcPCO2 measurements determined at each time point for evening and morning arterial samples.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Data were obtained from 37 participants. A statistically significant difference in the tcPCO2 values at the point of arterial sampling was found, with tcPCO2 on average 2.2\u20132.8\u00a0mmHg less than PaCO2 at various timepoints after arterial sampling. The upper limit of measurement accuracy represented a moderate difference (2\u20134.9\u00a0mmHg), within the clinically acceptable range of \u22127.5 to +7.5\u00a0mmHg variation from PaCO2 values.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The SenTec tcPCO2 electrode was found to be an appropriate alternative to arterial sampling for assessment of arterial carbon dioxide in adult patients in the PSG setting, with no significant difference in tcPCO2 accuracy based on the timing of transcutaneous measurements (up to 2\u00a0min) following arterial sampling.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1093\/sleep\/zsaf277","type":"journal-article","created":{"date-parts":[[2025,9,12]],"date-time":"2025-09-12T11:55:54Z","timestamp":1757678154000},"source":"Crossref","is-referenced-by-count":3,"title":["Transcutaneous versus arterial carbon dioxide monitoring in adult polysomnography studies"],"prefix":"10.1093","volume":"49","author":[{"given":"Keeley A","family":"Miller","sequence":"first","affiliation":[{"name":"Department of Medicine, University of Melbourne , Melbourne, VIC ,","place":["Australia"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thomas J","family":"Churchward","sequence":"additional","affiliation":[{"name":"Department of Respiratory and Sleep Medicine, Austin Health , Heidelberg, VIC ,","place":["Australia"]},{"name":"Institute for Breathing and Sleep , Heidelberg, VIC ,","place":["Australia"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7002-2657","authenticated-orcid":false,"given":"Julie","family":"Tolson","sequence":"additional","affiliation":[{"name":"Department of Medicine, University of Melbourne , Melbourne, VIC ,","place":["Australia"]},{"name":"Department of Respiratory and Sleep Medicine, Austin Health , Heidelberg, VIC ,","place":["Australia"]},{"name":"Institute for Breathing and Sleep , Heidelberg, VIC ,","place":["Australia"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9626-7460","authenticated-orcid":false,"given":"Warren R","family":"Ruehland","sequence":"additional","affiliation":[{"name":"Department of Respiratory and Sleep Medicine, Austin Health , Heidelberg, VIC ,","place":["Australia"]},{"name":"Institute for Breathing and Sleep , Heidelberg, VIC ,","place":["Australia"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christine F","family":"McDonald","sequence":"additional","affiliation":[{"name":"Department of Medicine, University of Melbourne , Melbourne, VIC ,","place":["Australia"]},{"name":"Department of Respiratory and Sleep Medicine, Austin Health , Heidelberg, VIC ,","place":["Australia"]},{"name":"Institute for Breathing and Sleep , Heidelberg, VIC ,","place":["Australia"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christopher J","family":"Worsnop","sequence":"additional","affiliation":[{"name":"Department of Medicine, University of Melbourne , Melbourne, VIC ,","place":["Australia"]},{"name":"Department of Respiratory and Sleep Medicine, Austin Health , Heidelberg, VIC ,","place":["Australia"]},{"name":"Institute for Breathing and Sleep , Heidelberg, VIC ,","place":["Australia"]}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"286","published-online":{"date-parts":[[2025,9,13]]},"reference":[{"issue":"4","key":"2026031105042205100_ref1","doi-asserted-by":"publisher","first-page":"308","DOI":"10.1111\/resp.13469","article-title":"Benefits of non-invasive ventilation in acute hypercapnic respiratory failure","volume":"24","author":"Comellini","year":"2019","journal-title":"Respirology."},{"issue":"6","key":"2026031105042205100_ref2","doi-asserted-by":"publisher","first-page":"527","DOI":"10.1097\/mcp.0000000000000320","article-title":"Noninvasive monitoring of CO2 during polysomnography: a review of the recent literature","volume":"22","author":"Gerdung","year":"2016","journal-title":"Curr Opin Pulm Med"},{"issue":"6","key":"2026031105042205100_ref3","doi-asserted-by":"publisher","first-page":"409","DOI":"10.1016\/0954-6111(93)90065-8","article-title":"Hypercapnic respiratory failure","volume":"87","author":"Zakynthinos","year":"1993","journal-title":"Respir Med"},{"key":"2026031105042205100_ref4","volume-title":"Noninvasive Positive Pressure Ventilation in the Home","author":"Wilson","year":"2019"},{"issue":"4","key":"2026031105042205100_ref5","doi-asserted-by":"publisher","first-page":"394","DOI":"10.1111\/j.1365-2044.2007.04987.x","article-title":"The accuracy of non-invasive carbon dioxide monitoring: a clinical evaluation of two transcutaneous systems","volume":"62","author":"Bolliger","year":"2007","journal-title":"Anaesthesia."},{"issue":"11","key":"2026031105042205100_ref6","doi-asserted-by":"publisher","first-page":"2035","DOI":"10.1513\/AnnalsATS.201606-454FR","article-title":"Home mechanical ventilation: an overview","volume":"13","author":"Simmonds","year":"2016","journal-title":"Ann Am Thorac Soc."},{"issue":"1","key":"2026031105042205100_ref7","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1016\/j.chest.2017.06.036","article-title":"Initiation of noninvasive ventilation for sleep related hypoventilation disorders: advanced modes and devices","volume":"153","author":"Selim","year":"2018","journal-title":"Chest"},{"key":"2026031105042205100_ref8","doi-asserted-by":"publisher","first-page":"908","DOI":"10.1152\/jappl.1998.85.3.908","article-title":"Activities of respiratory pump and upper airway muscles during sleep onset","volume":"85","author":"Worsnop","year":"1998","journal-title":"J Appl Physiol"},{"issue":"4","key":"2026031105042205100_ref9","doi-asserted-by":"publisher","first-page":"920","DOI":"10.1183\/09031936.97.10040920","article-title":"Impact of sleep in respiratory failure","volume":"10","author":"McNicholas","year":"1997","journal-title":"Eur Respir J"},{"issue":"2","key":"2026031105042205100_ref10","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1136\/thoraxjnl-2017-211466","article-title":"Accuracy and precision of transcutaneous carbon dioxide monitoring: a systematic review and meta-analysis","volume":"74","author":"Conway","year":"2018","journal-title":"Thorax."},{"issue":"16","key":"2026031105042205100_ref11","doi-asserted-by":"publisher","first-page":"5636","DOI":"10.3390\/s21165636","article-title":"Recent insights into the measurement of carbon dioxide concentrations for clinical practice in respiratory medicine","volume":"21","author":"Umeda","year":"2021","journal-title":"Sensors."},{"key":"2026031105042205100_ref12","volume-title":"Noninvasive Ventilation and Oxygenation Monitoring. Instruction Manual for the SenTec Digital Monitoring System: Software Version SMB SW-V08.03","author":"SenTec Digital Monitoring System"},{"issue":"1","key":"2026031105042205100_ref13","doi-asserted-by":"publisher","first-page":"60","DOI":"10.1007\/BF01619178","article-title":"History of blood gas analysis. III. Carbon dioxide tension","volume":"2","author":"Severinghaus","year":"1986","journal-title":"J Clin Monit Comput"},{"issue":"10","key":"2026031105042205100_ref14","doi-asserted-by":"publisher","first-page":"2203","DOI":"10.1097\/01.CCM.0000181734.26070.26","article-title":"Transcutaneous PCO2 monitoring in critically ill adults: clinical evaluation of a new sensor","volume":"33","author":"Bendjelid","year":"2005","journal-title":"Crit Care Med"},{"issue":"7","key":"2026031105042205100_ref15","doi-asserted-by":"publisher","first-page":"907","DOI":"10.4187\/respcare.05936","article-title":"Accuracy of transcutaneous CO2 values compared with arterial and capillary blood gases","volume":"63","author":"Lambert","year":"2018","journal-title":"Respir Care"},{"issue":"1","key":"2026031105042205100_ref16","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1016\/j.rmed.2010.10.007","article-title":"Transcutaneous monitoring as a replacement for arterial PCO2 monitoring during nocturnal non-invasive ventilation","volume":"105","author":"Storre","year":"2011","journal-title":"Respir Med"},{"issue":"3","key":"2026031105042205100_ref17","doi-asserted-by":"publisher","first-page":"768","DOI":"10.1378\/chest.113.3.768","article-title":"Transcutaneous PCO2 to monitor noninvasive mechanical ventilation in adults: assessment of a new transcutaneous PCO2 device","volume":"113","author":"Janssens","year":"1997","journal-title":"Chest"}],"container-title":["SLEEPJ"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/sleep\/advance-article-pdf\/doi\/10.1093\/sleep\/zsaf277\/64260928\/zsaf277.pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/sleep\/article-pdf\/49\/3\/zsaf277\/64260928\/zsaf277.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/sleep\/article-pdf\/49\/3\/zsaf277\/64260928\/zsaf277.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,11]],"date-time":"2026-03-11T09:04:27Z","timestamp":1773219867000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/sleep\/article\/doi\/10.1093\/sleep\/zsaf277\/8253412"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,13]]},"references-count":17,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2025,9,13]]},"published-print":{"date-parts":[[2026,3,11]]}},"URL":"https:\/\/doi.org\/10.1093\/sleep\/zsaf277","relation":{},"ISSN":["0161-8105","1550-9109"],"issn-type":[{"value":"0161-8105","type":"print"},{"value":"1550-9109","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2026,3]]},"published":{"date-parts":[[2025,9,13]]},"article-number":"zsaf277"}}