{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T02:48:34Z","timestamp":1785552514832,"version":"3.56.0"},"reference-count":18,"publisher":"Oxford University Press (OUP)","issue":"3","license":[{"start":{"date-parts":[[2025,11,22]],"date-time":"2025-11-22T00:00:00Z","timestamp":1763769600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/pages\/standard-publication-reuse-rights"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,3,11]]},"DOI":"10.1093\/sleep\/zsaf372","type":"journal-article","created":{"date-parts":[[2025,11,20]],"date-time":"2025-11-20T13:37:59Z","timestamp":1763645879000},"source":"Crossref","is-referenced-by-count":2,"title":["Are transcutaneous partial pressure of carbon dioxide measurements valid as estimates of arterial partial pressure of carbon dioxide during sleep?"],"prefix":"10.1093","volume":"49","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3115-9842","authenticated-orcid":false,"given":"Akira","family":"Umeda","sequence":"first","affiliation":[{"name":"Department of General Medicine, School of Medicine, International University of Health and Welfare (IUHW) , Narita-City, Chiba Prefecture ,","place":["Japan"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8195-6036","authenticated-orcid":false,"given":"David","family":"Gozal","sequence":"additional","affiliation":[{"name":"Office of the Dean and Departments of Pediatrics and Biomedical Sciences, Joan C. Edwards School of Medicine, Marshal University , Huntington, WV ,","place":["United States"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2025,11,22]]},"reference":[{"issue":"6","key":"2026031105085483800_ref1","doi-asserted-by":"publisher","first-page":"527","DOI":"10.1097\/MCP.0000000000000320","article-title":"Noninvasive monitoring of CO2 during polysomnography: a review of the recent literature","volume":"22","author":"Gerdung","year":"2016","journal-title":"Curr Opin Pulm Med"},{"issue":"1","key":"2026031105085483800_ref2","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1016\/j.artmed.2007.09.001","article-title":"Overnight features of transcutaneous carbon dioxide measurement as predictors of metabolic status","volume":"42","author":"Virkki","year":"2008","journal-title":"Artif Intell Med"},{"key":"2026031105085483800_ref3","doi-asserted-by":"publisher","author":"","DOI":"10.1093\/sleep\/zsaf277"},{"issue":"2","key":"2026031105085483800_ref4","doi-asserted-by":"publisher","first-page":"139","DOI":"10.1159\/000295904","article-title":"Evaluation of a system for transcutaneous long-term capnometry","volume":"80","author":"Randerath","year":"2010","journal-title":"Respiration."},{"issue":"4","key":"2026031105085483800_ref5","doi-asserted-by":"publisher","first-page":"442","DOI":"10.4187\/respcare.00454","article-title":"Transcutaneous measurement of carbon dioxide tension during extended monitoring: evaluation of accuracy and stability, and an algorithm for correcting calibration drift","volume":"56","author":"Berlowitz","year":"2011","journal-title":"Respir Care"},{"issue":"6","key":"2026031105085483800_ref6","doi-asserted-by":"publisher","first-page":"977","DOI":"10.1183\/09031936.03.00066802","article-title":"Sleep hypoventilation in hypercapnic chronic obstructive pulmonary disease: prevalence and associated factors","volume":"21","author":"O'Donoghue","year":"2003","journal-title":"Eur Respir J"},{"issue":"11","key":"2026031105085483800_ref7","doi-asserted-by":"publisher","first-page":"1955","DOI":"10.4187\/respcare.02011","article-title":"AARC clinical practice guideline: transcutaneous monitoring of carbon dioxide and oxygen: 2012","volume":"57","author":"Restrepo","year":"2012","journal-title":"Respir Care"},{"issue":"1","key":"2026031105085483800_ref8","doi-asserted-by":"publisher","first-page":"151","DOI":"10.1186\/s12890-020-01184-w","article-title":"Evaluation of time courses of agreement between minutely obtained transcutaneous blood gas data and the gold standard arterial data from spontaneously breathing Asian adults, and various subgroup analyses","volume":"20","author":"Umeda","year":"2020","journal-title":"BMC Pulm Med"},{"issue":"2","key":"2026031105085483800_ref9","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1164\/arrd.1981.124.2.199","article-title":"Transcutaneous carbon dioxide monitoring","volume":"124","author":"McLellan","year":"1981","journal-title":"Am Rev Respir Dis"},{"key":"2026031105085483800_ref10","first-page":"1","volume-title":"Ventilation\/Blood Flow and Gas Exchange","author":"West","year":"1985","edition":"4th"},{"key":"2026031105085483800_ref11","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/978-1-4613-1167-6","volume-title":"Respiratory Physiology","author":"Prange","year":"1996"},{"key":"2026031105085483800_ref12","first-page":"152\u2013159.","article-title":"Transcutaneous blood gas analysis","volume":"27","author":"Severinghaus","year":"1982","journal-title":"Respir Care"},{"key":"2026031105085483800_ref13","volume-title":"SDM Technical Manual","author":"SenTec"},{"issue":"8476","key":"2026031105085483800_ref14","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","article-title":"Statistical methods for assessing agreement between two methods of clinical measurement","volume":"1","author":"Bland","year":"1986","journal-title":"Lancet."},{"issue":"1","key":"2026031105085483800_ref15","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1016\/j.rmed.2010.10.007","article-title":"Transcutaneous monitoring as a replacement for arterial PCO(2) monitoring during nocturnal non-invasive ventilation","volume":"105","author":"Storre","year":"2011","journal-title":"Respir Med"},{"key":"2026031105085483800_ref16","first-page":"387","volume-title":"Clinical Blood Gases: Assessment and Intervention","author":"Malley","year":"2005","edition":"2nd"},{"issue":"16","key":"2026031105085483800_ref17","doi-asserted-by":"publisher","first-page":"5636","DOI":"10.3390\/s21165636","article-title":"Recent insights into the measurement of carbon dioxide concentrations for clinical practice in respiratory medicine","volume":"21","author":"Umeda","year":"2021","journal-title":"Sensors (Basel)"},{"issue":"5","key":"2026031105085483800_ref18","doi-asserted-by":"publisher","first-page":"887","DOI":"10.1016\/j.resinv.2025.06.001","article-title":"Transcutaneous CO2 and O2 monitoring during walking with a high-flow nasal cannula in patients with chronic obstructive pulmonary disease","volume":"63","author":"Umeda","year":"2025","journal-title":"Respir Investig"}],"container-title":["SLEEPJ"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/sleep\/advance-article-pdf\/doi\/10.1093\/sleep\/zsaf372\/65467867\/zsaf372.pdf","content-type":"application\/pdf","content-version":"am","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/sleep\/article-pdf\/49\/3\/zsaf372\/65467867\/zsaf372.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/sleep\/article-pdf\/49\/3\/zsaf372\/65467867\/zsaf372.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,11]],"date-time":"2026-03-11T09:08:58Z","timestamp":1773220138000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/sleep\/article\/doi\/10.1093\/sleep\/zsaf372\/8340168"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11,22]]},"references-count":18,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2025,11,22]]},"published-print":{"date-parts":[[2026,3,11]]}},"URL":"https:\/\/doi.org\/10.1093\/sleep\/zsaf372","relation":{},"ISSN":["0161-8105","1550-9109"],"issn-type":[{"value":"0161-8105","type":"print"},{"value":"1550-9109","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2026,3]]},"published":{"date-parts":[[2025,11,22]]},"article-number":"zsaf372"}}