{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,14]],"date-time":"2026-10-14T17:12:34Z","timestamp":1791997954392,"version":"4.4.0"},"reference-count":30,"publisher":"Oxford University Press (OUP)","issue":"3","license":[{"start":{"date-parts":[[2020,8,5]],"date-time":"2020-08-05T00:00:00Z","timestamp":1596585600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2021,7,2]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:sec>\n                  <jats:title>Objective<\/jats:title>\n                  <jats:p>Hemoglobin (Hb) measurement is one of the most commonly used laboratory tests in medical practice. Unnecessary blood sampling, especially in neonatal intensive care units (NICUs), contributes to iatrogenic anemia. Continuous non-invasive monitoring of total Hb (SpHb) was compared with invasive venous blood samples (tHb) in NICU patients.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Methods<\/jats:title>\n                  <jats:p>Three hundred and ten patients were identified in NICU. Non-invasive Hb measurement was performed immediately before venous blood sampling and comparison of invasive with non-invasive values was undertaken.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Results<\/jats:title>\n                  <jats:p>There was a strongly positive correlation between SpHb and tHb (r\u2009=\u20090.965, p\u2009&amp;lt;\u20090.001). Bland\u2013Altman analysis was performed in 95% limits of agreement for Hb values measured by both methods. The mean bias between tHb and SpHb measurements was 0.05\u2009g\/dl (\u22121.85 to 1.96). In Passing\u2013Bablok regression analysis, the CUSUM test p value was found to be 0.98 for Hb levels measured by SpHb and tHb; and the difference between the methods was not significant.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Conclusion<\/jats:title>\n                  <jats:p>In newborns, SpHb method offers reliable Hb values, which are comparable with the more traditional tHb method. Continuous non-invasive monitoring of total Hb may help prevent unnecessary blood sampling and iatrogenic anemia. Further clinical studies are required for the effectiveness of the method in critically ill patients with circulatory disorders.<\/jats:p>\n               <\/jats:sec>","DOI":"10.1093\/tropej\/fmaa050","type":"journal-article","created":{"date-parts":[[2020,6,16]],"date-time":"2020-06-16T19:11:11Z","timestamp":1592334671000},"source":"Crossref","is-referenced-by-count":15,"title":["The Comparison of Hemoglobin Values Measured by Blood and Continuous Non-Invasive Monitoring (SpHb) in Newborn Infants"],"prefix":"10.1093","volume":"67","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4671-4028","authenticated-orcid":false,"given":"Halil","family":"Kazanasmaz","sequence":"first","affiliation":[{"name":"Department of Pediatrics, Faculty of Medicine, Harran University, Sanliurfa, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mahmut","family":"Demir","sequence":"additional","affiliation":[{"name":"Department of Pediatrics, Faculty of Medicine, Harran University, Sanliurfa, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"286","published-online":{"date-parts":[[2020,8,5]]},"reference":[{"key":"2021072906194619300_fmaa050-B1","doi-asserted-by":"crossref","first-page":"513","DOI":"10.1016\/j.clinbiochem.2017.04.006","article-title":"Effects of preanalytical factors on hemoglobin measurement: a comparison of two HemoCue\u00ae point-of-care analyzers","volume":"50","author":"Whitehead","year":"2017","journal-title":"Clin Biochem"},{"key":"2021072906194619300_fmaa050-B2","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1111\/ijlh.12583","article-title":"A method comparison study between two hemoglobinometer models (Hemocue Hb 301 and Hb 201+) to measure hemoglobin concentrations and estimate anemia prevalence among women in Preah Vihear, Cambodia","volume":"39","author":"Rappaport","year":"2017","journal-title":"Int J Lab Hematol"},{"key":"2021072906194619300_fmaa050-B3","doi-asserted-by":"crossref","first-page":"2055","DOI":"10.1016\/j.jpedsurg.2017.12.015","article-title":"Continuous hemoglobin monitoring in pediatric trauma patients with solid organ injury","volume":"53","author":"Welker","year":"2018","journal-title":"J Pediatr Surg"},{"key":"2021072906194619300_fmaa050-B4","doi-asserted-by":"crossref","first-page":"1025","DOI":"10.1007\/s10877-018-0101-z","article-title":"Accuracy and trending of non-invasive hemoglobin measurement during different volume and perfusion statuses","volume":"32","author":"Adel","year":"2018","journal-title":"J Clin Monit Comput"},{"key":"2021072906194619300_fmaa050-B5","doi-asserted-by":"crossref","first-page":"638","DOI":"10.1016\/j.hrtlng.2018.06.007","article-title":"Is the new, noninvasive, continuous cardiorespiratory monitoring reliable during neonatal ECMO?","volume":"47","author":"Raffaeli","year":"2018","journal-title":"Heart Lung"},{"key":"2021072906194619300_fmaa050-B6","doi-asserted-by":"crossref","first-page":"349","DOI":"10.2106\/JBJS.O.00820","article-title":"Noninvasive hemoglobin monitoring: a rapid, reliable, and cost-effective method following total joint replacement","volume":"98","author":"Martin","year":"2016","journal-title":"J Bone Joint Surg Am"},{"key":"2021072906194619300_fmaa050-B7","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1016\/j.medin.2016.06.011","article-title":"Noninvasive hemoglobin monitoring in critically ill pediatric patients at risk of bleeding","volume":"41","author":"Garc\u00eda-Soler","year":"2017","journal-title":"Med Intensiva"},{"key":"2021072906194619300_fmaa050-B8","doi-asserted-by":"crossref","first-page":"863","DOI":"10.1007\/s10877-017-0098-8","article-title":"Comparison of the accuracy of noninvasive hemoglobin monitoring for preoperative evaluation between adult and pediatric patients: a retrospective study","volume":"32","author":"Park","year":"2018","journal-title":"J Clin Monit Comput"},{"key":"2021072906194619300_fmaa050-B9","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1097\/PCC.0b013e318260117d","article-title":"The efficacy of noninvasive hemoglobin measurement by pulse CO-oximetry in neonates","volume":"14","author":"Jung","year":"2013","journal-title":"Pediatr Crit Care Med"},{"key":"2021072906194619300_fmaa050-B10","doi-asserted-by":"crossref","first-page":"1046","DOI":"10.1111\/pan.12683","article-title":"Comparison of the gold standard of hemoglobin measurement with the clinical standard (BGA) and noninvasive hemoglobin measurement (SpHb) in small children: a prospective diagnostic observational study","volume":"25","author":"Wittenmeier","year":"2015","journal-title":"Paediatr Anaesth"},{"key":"2021072906194619300_fmaa050-B11","doi-asserted-by":"crossref","first-page":"617","DOI":"10.1038\/jp.2015.12","article-title":"Validation of noninvasive hemoglobin measurement by pulse CO-oximeter in newborn infants","volume":"35","author":"Nicholas","year":"2015","journal-title":"J Perinatol"},{"key":"2021072906194619300_fmaa050-B12","doi-asserted-by":"crossref","first-page":"604","DOI":"10.1111\/anae.13450","article-title":"Radical-7 pulse CO-oximetry","volume":"71","author":"Geoghegan","year":"2016","journal-title":"Anaesthesia"},{"key":"2021072906194619300_fmaa050-B13","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1093\/tropej\/fmx037","article-title":"Comprehensive analysis of liberal and restrictive transfusion strategies in pediatric intensive care unit","volume":"64","author":"Akyildiz","year":"2018","journal-title":"J Trop Pediatr"},{"key":"2021072906194619300_fmaa050-B14","doi-asserted-by":"crossref","DOI":"10.1136\/bcr-2016-216787","article-title":"Pulse oximetry error in a patient with a Santa Ana haemoglobinopathy","author":"Robertson","year":"2016","journal-title":"BMJ Case Rep"},{"key":"2021072906194619300_fmaa050-B15","doi-asserted-by":"crossref","first-page":"1519","DOI":"10.1213\/ANE.0000000000002721","article-title":"The clinical utility of noninvasive pulse CO-oximetry hemoglobin measurements in dark-skinned critically ill patients","volume":"126","author":"Murphy","year":"2018","journal-title":"Anesth Analg"},{"key":"2021072906194619300_fmaa050-B16","doi-asserted-by":"crossref","first-page":"826","DOI":"10.1080\/15563650.2016.1217421","article-title":"Methemoglobin measurements are underestimated by the Radical 7 CO-oximeter: experience from a series of moderate to severe propanil poisonings","volume":"54","author":"Hulse","year":"2016","journal-title":"Clin Toxicol (Phila)"},{"key":"2021072906194619300_fmaa050-B17","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1080\/15563650.2016.1263856","article-title":"RE: methemoglobin measurements are underestimated by the radical 7 CO-oximeter: experience from a series of moderate to severe propanil poisonings","volume":"55","author":"Zamani","year":"2017","journal-title":"Clin Toxicol (Phila)"},{"key":"2021072906194619300_fmaa050-B18","doi-asserted-by":"crossref","first-page":"352","DOI":"10.4097\/kjae.2015.68.4.352","article-title":"The changes of non-invasive hemoglobin and perfusion index of pulse CO-Oximetry during induction of general anesthesia","volume":"68","author":"Park","year":"2015","journal-title":"Korean J Anesthesiol"},{"key":"2021072906194619300_fmaa050-B19","doi-asserted-by":"crossref","first-page":"20150039","DOI":"10.1515\/ijb-2015-0039","article-title":"Sample size for assessing agreement between two methods of measurement by Bland-Altman method","volume":"12","author":"Lu","year":"2016","journal-title":"Int J Biostat"},{"key":"2021072906194619300_fmaa050-B20","doi-asserted-by":"crossref","first-page":"565","DOI":"10.1213\/ANE.0000000000000605","article-title":"Continuous noninvasive hemoglobin monitoring: a measured response to a critical review","volume":"122","author":"Barker","year":"2016","journal-title":"Anesth Analg"},{"key":"2021072906194619300_fmaa050-B21","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","article-title":"Statistical methods for assessing agreement between two methods of clinical measurement","volume":"327","author":"Bland","year":"1986","journal-title":"Lancet"},{"key":"2021072906194619300_fmaa050-B22","doi-asserted-by":"crossref","first-page":"191","DOI":"10.17219\/acem\/32065","article-title":"Prevention of iatrogenic anemia in critical and neonatal care","volume":"25","author":"Jakacka","year":"2016","journal-title":"Adv Clin Exp Med"},{"key":"2021072906194619300_fmaa050-B23","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1016\/j.aucc.2015.06.002","article-title":"True Blood\u2019 The Critical Care Story: An audit of blood sampling practice across three adult, paediatric and neonatal intensive care settings","volume":"29","author":"Ullman","year":"2016","journal-title":"Aust Crit Care"},{"key":"2021072906194619300_fmaa050-B24","doi-asserted-by":"crossref","first-page":"278","DOI":"10.1186\/s13054-019-2511-9","article-title":"Interventions to prevent iatrogenic anemia: a Laboratory Medicine Best Practices systematic review","volume":"23","author":"Whitehead","year":"2019","journal-title":"Crit Care"},{"key":"2021072906194619300_fmaa050-B25","doi-asserted-by":"crossref","first-page":"485","DOI":"10.23736\/S0375-9393.17.11652-4","article-title":"Accuracy of non-invasive hemoglobin monitoring by pulse CO-oximeter during liver transplantation","volume":"83","author":"Erdogan Kayhan","year":"2017","journal-title":"Minerva Anestesiol"},{"key":"2021072906194619300_fmaa050-B26","doi-asserted-by":"crossref","first-page":"1367","DOI":"10.3390\/s18051367","article-title":"Economic analysis of the reduction of blood transfusions during surgical procedures while continuous hemoglobin monitoring is used","volume":"18","author":"Ribed-S\u00e1nchez","year":"2018","journal-title":"Sensors (Basel)"},{"key":"2021072906194619300_fmaa050-B27","doi-asserted-by":"crossref","first-page":"1131","DOI":"10.1111\/pan.13229","article-title":"Can noninvasive hemoglobin measurement reduce the need for preoperative venipuncture in pediatric outpatient surgery?","volume":"27","author":"Zeng","year":"2017","journal-title":"Pediatr Anaesth"},{"key":"2021072906194619300_fmaa050-B28","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1186\/s12871-019-0755-1","article-title":"Continuous noninvasive hemoglobin monitoring estimates timing for detecting anemia better than clinicians: a randomized controlled trial","volume":"19","author":"Tang","year":"2019","journal-title":"BMC Anesthesiol"},{"key":"2021072906194619300_fmaa050-B29","first-page":"778","article-title":"[Comparison between continuous noninvasive hemoglobin monitoring and venous blood hemoglobin monitoring in children with kidney disease]","volume":"49","author":"Liu","year":"2017","journal-title":"Beijing Da Xue Xue Bao Yi Xue Ban"},{"key":"2021072906194619300_fmaa050-B30","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1007\/s10877-012-9397-2","article-title":"Validation of continuous and noninvasive hemoglobin monitoring by pulse CO-oximetry in Japanese surgical patients","volume":"27","author":"Isosu","year":"2013","journal-title":"J Clin Monit Comput"}],"container-title":["Journal of Tropical Pediatrics"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/academic.oup.com\/tropej\/article-pdf\/67\/3\/fmaa050\/39376907\/fmaa050.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/academic.oup.com\/tropej\/article-pdf\/67\/3\/fmaa050\/39376907\/fmaa050.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,7,29]],"date-time":"2021-07-29T06:20:28Z","timestamp":1627539628000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/tropej\/article\/doi\/10.1093\/tropej\/fmaa050\/5881348"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,8,5]]},"references-count":30,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2021,7,2]]}},"URL":"https:\/\/doi.org\/10.1093\/tropej\/fmaa050","relation":{},"ISSN":["0142-6338","1465-3664"],"issn-type":[{"value":"0142-6338","type":"print"},{"value":"1465-3664","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2021,6,1]]},"published":{"date-parts":[[2020,8,5]]},"article-number":"fmaa050"}}