{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,20]],"date-time":"2025-12-20T22:11:58Z","timestamp":1766268718578,"version":"3.37.3"},"reference-count":25,"publisher":"Oxford University Press (OUP)","issue":"8","license":[{"start":{"date-parts":[[2024,5,21]],"date-time":"2024-05-21T00:00:00Z","timestamp":1716249600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/pages\/standard-publication-reuse-rights"}],"funder":[{"name":"European Radiation Dosimetry Group"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,6,3]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>Interventional cardiology is characterized by high radiation exposure for both the patient and the operator. Adequate shielding and monitoring of the operator are fundamental to comply with radiation protection principles. In a previous work, the effect on the dose of the dosemeter position on the chest was studied. In this paper, the investigation has been completed, employing an anthropomorphic thorax phantom, equipped with arms. Although there are differences between the Monte Carlo simulations and the measurements, similar trends are observed, showing that the reduction in dose, due to the arms, is between 20 and 60%, compared with the situation without arms. For that reason, considering a dosemeter placed on the chest, the upper position, which is the least affected by the arms, should be preferred while the extreme lateral position, near the armpit, should be avoided.<\/jats:p>","DOI":"10.1093\/rpd\/ncae125","type":"journal-article","created":{"date-parts":[[2024,5,22]],"date-time":"2024-05-22T05:56:20Z","timestamp":1716357380000},"page":"802-807","source":"Crossref","is-referenced-by-count":1,"title":["Medical staff monitoring in interventional cardiology: over apron dosemeter placement based on measurements and simulations"],"prefix":"10.1093","volume":"200","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3912-7626","authenticated-orcid":false,"given":"Paolo","family":"Ferrari","sequence":"first","affiliation":[{"name":"ENEA-Italian National Agency for New Technologies, Energy and Sustainable Economic Development, IRP-Radiation Protection Institute , Bologna 40129 , Italy"}]},{"given":"Giovanna","family":"Venturi","sequence":"additional","affiliation":[{"name":"Medical Physics Department , , Forl\u00ec 47121 , Italy"},{"name":"AUSL Romagna , , Forl\u00ec 47121 , Italy"}]},{"given":"Lorenzo","family":"Campani","sequence":"additional","affiliation":[{"name":"ENEA-Italian National Agency for New Technologies, Energy and Sustainable Economic Development, IRP-Radiation Protection Institute , Bologna 40129 , Italy"}]},{"given":"Francesca","family":"Mariotti","sequence":"additional","affiliation":[{"name":"ENEA-Italian National Agency for New Technologies, Energy and Sustainable Economic Development, IRP-Radiation Protection Institute , Bologna 40129 , Italy"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0893-5391","authenticated-orcid":false,"given":"Frank","family":"Becker","sequence":"additional","affiliation":[{"name":"KIT-Karlsruhe Institute of Technology , , Eggenstein-Leopoldshafen 76344 , Germany"},{"name":"Institute for Nuclear Waste Disposal , , Eggenstein-Leopoldshafen 76344 , Germany"}]},{"given":"Jan","family":"Jansen","sequence":"additional","affiliation":[{"name":"UK Health Security Agency , Oxon OX11 0RQ , United Kingdom"}]},{"given":"Zoran","family":"Jovanovi\u0107","sequence":"additional","affiliation":[{"name":"Faculty of Science , , Kragujevac 34000 , Serbia"},{"name":"University of Kragujevac , , Kragujevac 34000 , Serbia"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3517-9210","authenticated-orcid":false,"given":"Dragana","family":"Krsti\u0107","sequence":"additional","affiliation":[{"name":"Faculty of Science , , Kragujevac 34000 , Serbia"},{"name":"University of Kragujevac , , Kragujevac 34000 , Serbia"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2705-7077","authenticated-orcid":false,"given":"Pedro","family":"Teles","sequence":"additional","affiliation":[{"name":"Faculty of Science , , Porto 4169-007 , Portugal"},{"name":"University of Porto and CI-IPOP (Porto Cancer Institute Research Centre) , , Porto 4169-007 , Portugal"}]}],"member":"286","published-online":{"date-parts":[[2024,5,21]]},"reference":[{"key":"2024060500061322600_ref1","doi-asserted-by":"crossref","first-page":"437","DOI":"10.1093\/rpd\/ncq326","article-title":"International project on individual monitoring and radiation exposure levels in interventional cardiology","volume":"144","author":"Padovani","year":"2011","journal-title":"Radiat Prot Dosim"},{"key":"2024060500061322600_ref2","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1177\/0146645317750356","article-title":"ICRP Publication139: occupational radiological protection in interventional procedures","volume":"47","author":"ICRP","year":"2018","journal-title":"Ann ICRP"},{"key":"2024060500061322600_ref3","doi-asserted-by":"crossref","first-page":"13131","DOI":"10.3390\/ijerph182413131","article-title":"Radiation protection in interventional radiology\/cardiology\u2014is state-of-the-art equipment used?","volume":"18","author":"Behr-Meenen","year":"2021","journal-title":"Int J Environ Res Public Health"},{"key":"2024060500061322600_ref4","doi-asserted-by":"crossref","first-page":"490","DOI":"10.1667\/RR2207.1","article-title":"Radiation cataract risk in interventional cardiology personnel","volume":"174","author":"Vano","year":"2010","journal-title":"Radiat Res"},{"key":"2024060500061322600_ref5","doi-asserted-by":"crossref","first-page":"1208","DOI":"10.1016\/j.ehj.2004.04.024","article-title":"Percutaneous coronary interventions in Europe 1992\u20132001","volume":"25","author":"Togni","year":"2004","journal-title":"Eur Heart J"},{"key":"2024060500061322600_ref6","first-page":"261","article-title":"The contribution of interventional cardiology procedures to the population radiation dose in a \u2018health-care level I\u2019 representative region","volume":"168","author":"Cornetto","year":"2016","journal-title":"Radiat Prot Dosim"},{"key":"2024060500061322600_ref7","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1002\/ccd.20457","article-title":"Impact of a lead glass screen on scatter radiation to eyes and hands in interventional cardiologists","volume":"67","author":"Maeder","year":"2006","journal-title":"Catheter Cardiovasc Interv"},{"key":"2024060500061322600_ref8","doi-asserted-by":"crossref","first-page":"1216","DOI":"10.1016\/j.radmeas.2011.06.057","article-title":"Study of the parameters affecting operator doses in interventional radiology using Monte Carlo simulations","volume":"46","author":"Koukorava","year":"2011","journal-title":"Radiat Meas"},{"key":"2024060500061322600_ref9","doi-asserted-by":"crossref","first-page":"902","DOI":"10.1088\/0952-4746\/36\/4\/902","article-title":"Monte Carlo study of the scattered radiation field near the eyes of the operator in interventional procedures","volume":"36","author":"Ferrari","year":"2016","journal-title":"J Radiol Prot"},{"key":"2024060500061322600_ref10","doi-asserted-by":"crossref","first-page":"250","DOI":"10.1093\/rpd\/ncm418","article-title":"Personal dose monitoring in hospitals: global assessment, critical applications and future needs","volume":"124","author":"Covens","year":"2007","journal-title":"Radiat Prot Dosim"},{"key":"2024060500061322600_ref11","doi-asserted-by":"crossref","first-page":"1077","DOI":"10.1088\/1361-6498\/aad429","article-title":"Strategies to optimise occupational radiation protection in interventional cardiology using simultaneous registration of patient and staff doses","volume":"38","author":"Vano","year":"2018","journal-title":"J Radiol Prot"},{"key":"2024060500061322600_ref12","doi-asserted-by":"crossref","first-page":"809","DOI":"10.1088\/1361-6498\/ab2c42","article-title":"Simulation of Hp(10) and effective dose received by the medical staff in interventional radiology procedures","volume":"39","author":"Ferrari","year":"2019","journal-title":"J Radiol Prot"},{"key":"2024060500061322600_ref13","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1016\/j.apradiso.2016.01.013","article-title":"Correlation between scatter radiation dose at height of operator's eye and dose to patient for different angiographic projections","volume":"117","author":"Leyton","year":"2016","journal-title":"Appl Radiat Isot"},{"key":"2024060500061322600_ref14","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1111\/joic.12263","article-title":"Impact of operators\u2019 height on individual radiation exposure measurement during catheter-based cardiovascular interventions","volume":"29","author":"Rigatelli","year":"2016","journal-title":"J Interv Cardiol"},{"key":"2024060500061322600_ref15","doi-asserted-by":"crossref","first-page":"1111","DOI":"10.1016\/j.ejmp.2016.08.010","article-title":"The influence of operator position, height and body orientation on eye lens dose in interventional radiology and cardiology: Monte Carlo simulations versus realistic clinical measurements","volume":"32","author":"Principi","year":"2016","journal-title":"Phys Med"},{"key":"2024060500061322600_ref16","doi-asserted-by":"crossref","first-page":"53","DOI":"10.3390\/environments9040053","article-title":"What is worth knowing in interventional practices about medical staff radiation exposure monitoring: a review of recent outcomes of EURADOS working group 12","volume":"9","author":"Ferrari","year":"2022","journal-title":"Environments-MDPI"},{"key":"2024060500061322600_ref17","doi-asserted-by":"crossref","first-page":"345","DOI":"10.1093\/rpd\/ncz173","article-title":"Determining the dose rate dependence of different active personal dosemeters in standardized pulsed and continuous radiation fields","volume":"187","author":"Hupe","year":"2019","journal-title":"Rad Prot Dosim"},{"key":"2024060500061322600_ref18","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1088\/1361-6498\/aaf2c0","article-title":"Effect of the radiation protective apron on the response of active and passive personal dosemeters used in interventional radiology and cardiology","volume":"39","author":"Ginjaume","year":"2019","journal-title":"J Radiol Prot"},{"key":"2024060500061322600_ref19","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1093\/rpd\/ncz253","article-title":"The use of active personal dosemeters in interventional workplaces in hospitals: comparison between active and passive dosemeters worn simultaneously by medical staff","volume":"188","author":"Vanhavere","year":"2020","journal-title":"Radiat Prot Dosim"},{"key":"2024060500061322600_ref20","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1016\/j.ejmp.2021.05.015","article-title":"Recommendations for the use of active personal dosemeters (APDs) in interventional workplaces in hospitals","volume":"87","author":"O'Connor","year":"2021","journal-title":"Phys Med"},{"key":"2024060500061322600_ref21","doi-asserted-by":"crossref","first-page":"1495","DOI":"10.1093\/rpd\/ncac188","article-title":"The placement of apron dosemeters and dose assessment in interventional cardiology procedures: preliminary results","volume":"198","author":"Ferrari","year":"2022","journal-title":"Radiat Prot Dosim"},{"volume-title":"MCNP6 User\u2019s Manual Version 1.0","year":"2013","author":"Pelowitz","key":"2024060500061322600_ref22"},{"key":"2024060500061322600_ref23","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1002\/ccd.24694","article-title":"Recommendations for occupational radiation protection in interventional cardiology","volume":"82","author":"Duran","year":"2013","journal-title":"Catheter Cardiovasc Interv"},{"key":"2024060500061322600_ref24","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1093\/rpd\/ncn085","article-title":"Dosemeter readings and effective dose to the cardiologist with protective clothing in a simulated interventional procedure","volume":"129","author":"Schultz","year":"2008","journal-title":"Radiat Prot Dosim"},{"key":"2024060500061322600_ref25","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1093\/rpd\/ncn082","article-title":"Overview of double dosimetry procedures for the determination of the effective dose to the interventional radiology staff","volume":"129","author":"J\u00e4rvinen","year":"2008","journal-title":"Radiat Prot Dosim"}],"container-title":["Radiation Protection Dosimetry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/academic.oup.com\/rpd\/article-pdf\/200\/8\/802\/58081043\/ncae125.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/academic.oup.com\/rpd\/article-pdf\/200\/8\/802\/58081043\/ncae125.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,6,5]],"date-time":"2024-06-05T01:37:26Z","timestamp":1717551446000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/rpd\/article\/200\/8\/802\/7678828"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,5,21]]},"references-count":25,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2024,5,21]]},"published-print":{"date-parts":[[2024,6,3]]}},"URL":"https:\/\/doi.org\/10.1093\/rpd\/ncae125","relation":{},"ISSN":["0144-8420","1742-3406"],"issn-type":[{"type":"print","value":"0144-8420"},{"type":"electronic","value":"1742-3406"}],"subject":[],"published-other":{"date-parts":[[2024,6]]},"published":{"date-parts":[[2024,5,21]]}}}