{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,6,7]],"date-time":"2025-06-07T22:22:15Z","timestamp":1749334935279,"version":"3.37.3"},"reference-count":23,"publisher":"Oxford University Press (OUP)","issue":"2","license":[{"start":{"date-parts":[[2018,11,29]],"date-time":"2018-11-29T00:00:00Z","timestamp":1543449600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/academic.oup.com\/journals\/pages\/open_access\/funder_policies\/chorus\/standard_publication_model"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019,8,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>In this work, the initial results of the type testing of the LiF:Mg,Cu,P (TLD-100H) whole-body personal dosemeters are presented. An assessment of reproducibility, linearity of the response, the residual signal as a function of the dose, energy and angular dependence of the response was performed. In general, the dosemeters show good reproducibility for different dose values and a linear behaviour for a range between 0.1 and 300 mSv. The detection limits obtained are lower than 50 \u03bcSv. The system presents a good energy and angular response for different radiation qualities.<\/jats:p>","DOI":"10.1093\/rpd\/ncy202","type":"journal-article","created":{"date-parts":[[2018,10,30]],"date-time":"2018-10-30T08:32:38Z","timestamp":1540888358000},"page":"216-223","source":"Crossref","is-referenced-by-count":2,"title":["TYPE TESTING OF LiF:Mg,Cu,P (TLD-100H)  WHOLE-BODY DOSEMETERS FOR THE ASSESSMENT OF Hp(10) AND Hp(0.07)"],"prefix":"10.1093","volume":"184","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0091-5097","authenticated-orcid":false,"given":"J S","family":"Pereira","sequence":"first","affiliation":[{"name":"Universidade de Lisboa (UL), Instituto Superior T\u00e9cnico (IST), Laborat\u00f3rio de Prote\u00e7\u00e3o e Seguran\u00e7a Radiol\u00f3gica (LPSR), Estrada Nacional 10 (ao km 139,7), Bobadela LRS, Portugal"},{"name":"UL-IST, Centro de Ci\u00eancias e Tecnologias Nucleares (C2TN), Estrada Nacional 10 (ao km 139,7), Bobadela LRS, Portugal"}]},{"given":"M F","family":"Pereira","sequence":"additional","affiliation":[{"name":"Universidade de Lisboa (UL), Instituto Superior T\u00e9cnico (IST), Laborat\u00f3rio de Prote\u00e7\u00e3o e Seguran\u00e7a Radiol\u00f3gica (LPSR), Estrada Nacional 10 (ao km 139,7), Bobadela LRS, Portugal"},{"name":"UL-IST, Centro de Ci\u00eancias e Tecnologias Nucleares (C2TN), Estrada Nacional 10 (ao km 139,7), Bobadela LRS, Portugal"}]},{"given":"S","family":"Rangel","sequence":"additional","affiliation":[{"name":"Universidade de Lisboa (UL), Instituto Superior T\u00e9cnico (IST), Laborat\u00f3rio de Prote\u00e7\u00e3o e Seguran\u00e7a Radiol\u00f3gica (LPSR), Estrada Nacional 10 (ao km 139,7), Bobadela LRS, Portugal"}]},{"given":"M","family":"Caldeira","sequence":"additional","affiliation":[{"name":"Universidade de Lisboa (UL), Instituto Superior T\u00e9cnico (IST), Laborat\u00f3rio de Prote\u00e7\u00e3o e Seguran\u00e7a Radiol\u00f3gica (LPSR), Estrada Nacional 10 (ao km 139,7), Bobadela LRS, Portugal"},{"name":"UL-IST, Centro de Ci\u00eancias e Tecnologias Nucleares (C2TN), Estrada Nacional 10 (ao km 139,7), Bobadela LRS, Portugal"}]},{"given":"G","family":"Carvalhal","sequence":"additional","affiliation":[{"name":"Universidade de Lisboa (UL), Instituto Superior T\u00e9cnico (IST), Laborat\u00f3rio de Prote\u00e7\u00e3o e Seguran\u00e7a Radiol\u00f3gica (LPSR), Estrada Nacional 10 (ao km 139,7), Bobadela LRS, Portugal"}]},{"given":"L M","family":"Santos","sequence":"additional","affiliation":[{"name":"Universidade de Lisboa (UL), Instituto Superior T\u00e9cnico (IST), Laborat\u00f3rio de Prote\u00e7\u00e3o e Seguran\u00e7a Radiol\u00f3gica (LPSR), Estrada Nacional 10 (ao km 139,7), Bobadela LRS, Portugal"}]},{"given":"J V","family":"Cardoso","sequence":"additional","affiliation":[{"name":"Universidade de Lisboa (UL), Instituto Superior T\u00e9cnico (IST), Laborat\u00f3rio de Prote\u00e7\u00e3o e Seguran\u00e7a Radiol\u00f3gica (LPSR), Estrada Nacional 10 (ao km 139,7), Bobadela LRS, Portugal"}]},{"given":"J G","family":"Alves","sequence":"additional","affiliation":[{"name":"Universidade de Lisboa (UL), Instituto Superior T\u00e9cnico (IST), Laborat\u00f3rio de Prote\u00e7\u00e3o e Seguran\u00e7a Radiol\u00f3gica (LPSR), Estrada Nacional 10 (ao km 139,7), Bobadela LRS, Portugal"},{"name":"UL-IST, Centro de Ci\u00eancias e Tecnologias Nucleares (C2TN), Estrada Nacional 10 (ao km 139,7), Bobadela LRS, Portugal"}]}],"member":"286","published-online":{"date-parts":[[2018,11,29]]},"reference":[{"volume-title":"Thermoluminescence Dosimetry Materials\u2014Properties and Uses","year":"1995","author":"McKeever","key":"2019082108152844100_ncy202C1"},{"key":"2019082108152844100_ncy202C2","doi-asserted-by":"crossref","DOI":"10.1017\/CBO9780511564994","volume-title":"Thermoluminescence of Solids","author":"McKeever","year":"1985"},{"key":"2019082108152844100_ncy202C3","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1093\/oxfordjournals.rpd.a079841","article-title":"The characteristics of new LiF preparations and sensitised LiF","volume":"17","author":"Driscoll","year":"1986","journal-title":"Radiat. Prot. Dosim."},{"key":"2019082108152844100_ncy202C4","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1016\/S0168-583X(01)00717-0","article-title":"High sensitivity thermoluminescence dosimetry","volume":"184","author":"Bos","year":"2001","journal-title":"Nucl. Instrum. Methods. Phys. Res. Sect. B"},{"key":"2019082108152844100_ncy202C5","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1093\/oxfordjournals.rpd.a005983","article-title":"A new paradigm in personal dosimetry using LiF:Mg,Cu,P","volume":"101","author":"Cassata","year":"2002","journal-title":"Radiat. Prot. Dosim."},{"key":"2019082108152844100_ncy202C6","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1016\/j.radmeas.2007.01.008","article-title":"Thermoluminescent materials for medical applications: LiF:Mg,Ti and LiF:Mg,Cu,P","volume":"41","author":"Moscovitch","year":"2007","journal-title":"Radiat. Meas."},{"key":"2019082108152844100_ncy202C7","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1093\/oxfordjournals.rpd.a032904","article-title":"Personnel dosimetry using LiF:Mg,Cu,P","volume":"85","author":"Moscovitch","year":"1999","journal-title":"Radiat. Prot. Dosim."},{"key":"2019082108152844100_ncy202C8","doi-asserted-by":"crossref","first-page":"248","DOI":"10.1093\/rpd\/nci692","article-title":"The application of LiF:Mg,Cu,P to large scale personnel dosimetry: current status and future directions","volume":"119","author":"Moscovitch","year":"2006","journal-title":"Radiat. Prot. Dosim."},{"key":"2019082108152844100_ncy202C9","first-page":"223","article-title":"Comparison of time effects, decision limit and residual signal in Harshaw LiF:Mg,Ti and LiF:Mg,Cu,P","volume":"125","author":"Gilvin","year":"2007","journal-title":"Radiat. Prot. Dosim."},{"key":"2019082108152844100_ncy202C10","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1093\/rpd\/ncm239","article-title":"Type testing of a new TLD for the UK health protection agency","volume":"128","author":"Gilvin","year":"2008","journal-title":"Radiat. Prot. Dosim."},{"key":"2019082108152844100_ncy202C11","doi-asserted-by":"crossref","first-page":"324","DOI":"10.1093\/rpd\/nci657","article-title":"Performance of Harshaw TLD-100H two-element dosemeter","volume":"120","author":"Luo","year":"2006","journal-title":"Radiat. Prot. Dosim."},{"key":"2019082108152844100_ncy202C12","first-page":"599","article-title":"Energy dependence of TLD-100 and MCP-N detectors","volume":"43","author":"Carinou","year":"2008","journal-title":"Radiat. Prot. Dosim."},{"key":"2019082108152844100_ncy202C13","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1093\/rpd\/ncv445","article-title":"Fading effect of LiF:Mg,Ti and LiF:Mg,Cu,P ext-rad and whole-body detectors","volume":"170","author":"Pereira","year":"2016","journal-title":"Radiat. Prot. Dosim."},{"year":"2009","author":"European Comission","key":"2019082108152844100_ncy202C14"},{"key":"2019082108152844100_ncy202C15"},{"key":"2019082108152844100_ncy202C16"},{"year":"2012","author":"International Electrotechnical Commission","key":"2019082108152844100_ncy202C17"},{"year":"1996","author":"International Organization for Standardization","key":"2019082108152844100_ncy202C18"},{"year":"1996","author":"International Organization for Standardization","key":"2019082108152844100_ncy202C19"},{"year":"1991","author":"International Organization for Standardization","key":"2019082108152844100_ncy202C20"},{"year":"1992","author":"Harshaw-Bicron","key":"2019082108152844100_ncy202C21"},{"year":"1994","author":"Harshaw-Bicron","key":"2019082108152844100_ncy202C22"},{"issue":"3","key":"2019082108152844100_ncy202C23","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1097\/00004032-199203000-00002","article-title":"Detection and determination limits for thermoluminescence dosimetry","volume":"62","author":"Hirning","year":"1992","journal-title":"Health Phys."}],"container-title":["Radiation Protection Dosimetry"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/academic.oup.com\/rpd\/article-pdf\/184\/2\/216\/29193945\/ncy202.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,8,21]],"date-time":"2019-08-21T08:16:52Z","timestamp":1566375412000},"score":1,"resource":{"primary":{"URL":"https:\/\/academic.oup.com\/rpd\/article\/184\/2\/216\/5212664"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,11,29]]},"references-count":23,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2018,11,29]]},"published-print":{"date-parts":[[2019,8,1]]}},"URL":"https:\/\/doi.org\/10.1093\/rpd\/ncy202","relation":{},"ISSN":["0144-8420","1742-3406"],"issn-type":[{"type":"print","value":"0144-8420"},{"type":"electronic","value":"1742-3406"}],"subject":[],"published-other":{"date-parts":[[2019,8]]},"published":{"date-parts":[[2018,11,29]]}}}