{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,9,24]],"date-time":"2023-09-24T04:22:10Z","timestamp":1695529330714},"reference-count":33,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Adv Skin Wound Care"],"published-print":{"date-parts":[[2018,3]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n          <jats:sec>\n            <jats:title>OBJECTIVE:<\/jats:title>\n            <jats:p>In the presence of pathologic conditions such as diabetes or neuropathy and activity-related forces, the plantar surface of the foot is a common place for skin breakdown. With this risk, foundational knowledge of typical plantar skin behavior is needed. The purpose of this study was to characterize the plantar skin properties (tangential stiffness, normal compliance, and thickness) across environmental condition and time.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>DESIGN AND SETTING:<\/jats:title>\n            <jats:p>Nonexperimental laboratory design.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>PATIENTS:<\/jats:title>\n            <jats:p>Sixteen individuals participated (age range, 19\u201378 years; mean age, 48.5 \u00b1 19.23 years; mean body mass index, 31.5 \u00b1 7.61 kg\/m<jats:sup>2<\/jats:sup>).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>MAIN OUTCOME MEASURES:<\/jats:title>\n            <jats:p>Tangential stiffness, normal compliance, and thickness were assessed with the Tissue Interrogation Device (TID), Myotonometer, and ultrasound, respectively. Measurements were taken at 5 anatomic locations over 4 visits across a day (morning and afternoon), week, and month. Measurements were taken in standard (20\u00b0 C to 24\u00b0 C, 35%\u201350% relative humidity) and shoe conditions (32\u00b0 C, 66% relative humidity).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>MAIN RESULTS:<\/jats:title>\n            <jats:p>Tangential stiffness (<jats:italic toggle=\"yes\">P<\/jats:italic> = .000), normal compliance (<jats:italic toggle=\"yes\">P<\/jats:italic> = .000), and thickness (epidermis, <jats:italic toggle=\"yes\">P<\/jats:italic> = .000; dermis, <jats:italic toggle=\"yes\">P<\/jats:italic> = .044) all varied by location. No main effect differences were noted across visits or environment across devices. Reliability varied across visits.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>CONCLUSIONS:<\/jats:title>\n            <jats:p>All 3 skin properties were found to vary across location and people. Given skin property consistency over time and device reliability, it is reasonable to take and compare measurements within a week. Environmental conditions should be reported and controlled in research assessing plantar skin.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/01.asw.0000530067.37008.e8","type":"journal-article","created":{"date-parts":[[2018,2,13]],"date-time":"2018-02-13T18:59:13Z","timestamp":1518548353000},"page":"123-129","source":"Crossref","is-referenced-by-count":1,"title":["The Characterization of Plantar Skin Across Environmental Condition and Time"],"prefix":"10.1097","volume":"31","author":[{"given":"Deborah M.","family":"Wendland","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stephen H.","family":"Sprigle","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"issue":"(10)","key":"bib1-20230923","first-page":"1386","article-title":"Identifying diabetic patients at high risk for lower-extremity amputation in a primary health care setting. A prospective evaluation of simple screening criteria","volume":"15","year":"1992","journal-title":"Diabetes Care"},{"issue":"(7)","key":"bib2-20230923","first-page":"1036","article-title":"A prospective study of risk factors for diabetic foot ulcer. The Seattle Diabetic Foot Study","volume":"22","year":"1999","journal-title":"Diabetes Care"},{"issue":"(1)","key":"bib3-20230923","first-page":"68","article-title":"Identifying patients with diabetes mellitus who are at risk for lower-extremity complications: use of Semmes-Weinstein monofilaments","volume":"76","year":"1996","journal-title":"Phys Ther"},{"issue":"(9)","key":"bib4-20230923","first-page":"1918","article-title":"Elevated plantar pressures in neuropathic diabetic patients with claw\/hammer toe deformity","volume":"38","year":"2005","journal-title":"J Biomech"},{"issue":"(12)","key":"bib5-20230923","first-page":"1796","article-title":"Plantar tissue stiffness in patients with diabetes mellitus and peripheral neuropathy","volume":"83","year":"2002","journal-title":"Arch Phys Med Rehabil"},{"issue":"(9)","key":"bib6-20230923","first-page":"1484","article-title":"Changes in the thickness and stiffness of plantar soft tissues in people with diabetic peripheral neuropathy","volume":"92","year":"2011","journal-title":"Arch Phys Med Rehabil"},{"issue":"(7)","key":"bib7-20230923","first-page":"1029","article-title":"Epidermal thickness and biomechanical properties of plantar tissues in diabetic foot","volume":"37","year":"2011","journal-title":"Ultrasound Med Amp Biol"},{"issue":"(3)","key":"bib8-20230923","first-page":"129","article-title":"Hardness of plantar skin in diabetic neuropathic feet","volume":"13","year":"1999","journal-title":"J Diabetes Complications"},{"issue":"(3)","key":"bib9-20230923","first-page":"451","article-title":"Biomechanical assessment of plantar foot tissue in diabetic patients using an ultrasound indentation system","volume":"26","year":"2000","journal-title":"Ultrasound Med Biol"},{"issue":"(5)","key":"bib10-20230923","first-page":"309","article-title":"Relationship of skin thickness to duration of diabetes, glycemic control, and diabetic complications in male IDDM patients","volume":"12","year":"1989","journal-title":"Diabetes Care"},{"issue":"(1)","key":"bib11-20230923","first-page":"55","article-title":"Dynamic indentation on human skin in vivo: ageing effects","volume":"15","year":"2009","journal-title":"Skin Res Technol"},{"issue":"(4)","key":"bib12-20230923","first-page":"590","article-title":"Dermal fluid translocation is an important determinant of the diurnal variation in human skin thickness","volume":"145","year":"2001","journal-title":"Br J Dermatol"},{"issue":"(3)","key":"bib13-20230923","first-page":"718","article-title":"Analysis of circadian and ultradian rhythms of skin surface properties of face and forearm of healthy women","volume":"117","year":"2001","journal-title":"J Invest Dermatol"},{"issue":"(3)","key":"bib14-20230923","first-page":"200","article-title":"Methodological aspects of high-frequency ultrasound of skin in children","volume":"10","year":"2004","journal-title":"Skin Res Technol"},{"issue":"(4)","key":"bib15-20230923","first-page":"147","article-title":"A tactile sensor for detection of physical properties of human skin in vivo","volume":"22","year":"1998","journal-title":"J Med Eng Technol"},{"issue":"(3)","key":"bib16-20230923","first-page":"353","article-title":"Age-related mechanical properties of human skin: an in vivo study","volume":"93","year":"1989","journal-title":"J Invest Dermatol"},{"issue":"(5)","key":"bib17-20230923","first-page":"621","article-title":"Assessment of aging of the human skin by in vivo ultrasonic imaging","volume":"93","year":"1989","journal-title":"J Invest Dermatol"},{"issue":"(2)","key":"bib18-20230923","first-page":"127","article-title":"Mechanical properties of human skin in vivo: a comparative evaluation in 300 men and women","volume":"20","year":"2014","journal-title":"Skin Res Technol"},{"issue":"(10)","key":"bib19-20230923","first-page":"921","article-title":"Integration of plantar soft tissue stiffness measurements in routine MRI of the diabetic foot","volume":"16","year":"2001","journal-title":"Clin Biomech (Bristol Avon)"},{"issue":"(3 Pt 1)","key":"bib20-20230923","first-page":"546","article-title":"Pathologic features of diabetic thick skin","volume":"16","year":"1987","journal-title":"J Am Acad Dermatol"},{"issue":"(5)","key":"bib21-20230923","first-page":"257","article-title":"Quantitative determination of skin thickness in diabetes mellitus: relationship to disease parameters","volume":"21","year":"1990","journal-title":"J Med"},{"issue":"(2)","key":"bib22-20230923","first-page":"96","article-title":"Model of the viscoelastic behaviour of skin in vivo and study of anisotropy","volume":"10","year":"2004","journal-title":"Skin Res Technol"},{"issue":"(2)","key":"bib23-20230923","first-page":"122","article-title":"Measurement of the mechanical properties of skin with ballistometer and suction cup","volume":"7","year":"2001","journal-title":"Skin Res Technol"},{"issue":"(6)","key":"bib24-20230923","first-page":"421","article-title":"Sex- and site-dependent variations in the thickness and mechanical properties of human skin in vivo","volume":"22","year":"2000","journal-title":"Int J Cosmet Sci"},{"issue":"(4)","key":"bib26-20230923","first-page":"308","article-title":"Mechanical properties and barrier function of healthy human skin","volume":"86","year":"2006","journal-title":"Acta Derm Venereol"},{"key":"bib27-20230923","article-title":"Systems and methods for the analysis of mechanical properties of materials"},{"issue":"(6)","key":"bib28-20230923","first-page":"928","article-title":"Myotonometer intra- and interrater reliabilities","volume":"84","year":"2003","journal-title":"Arch Phys Med Rehabil"},{"issue":"(3)","key":"bib29-20230923","first-page":"248","article-title":"Reliability of the myotonometer for assessment of posterior shoulder tightness","volume":"8","year":"2013","journal-title":"Int J Sports Phys Ther"},{"issue":"(6)","key":"bib30-20230923","first-page":"804","article-title":"Assessment of an ultrasonic dermal scanner for skin thickness measurements","volume":"30","year":"2008","journal-title":"Med Eng Phys"},{"issue":"(1)","key":"bib33-20230923","first-page":"18","article-title":"Viscoelastic properties of human skin and processed dermis","volume":"7","year":"2001","journal-title":"Skin Res Technol"},{"issue":"(2)","key":"bib34-20230923","first-page":"145","article-title":"On the orthogonal anisotropy of human skin as a function of anatomical region","volume":"34","year":"1996","journal-title":"Connect Tissue Res"},{"key":"bib35-20230923","first-page":"657","article-title":"Skin thickness measurement by pulsed ultrasound: its reproducibility, validation and variability","volume":"106","year":"1982","journal-title":"Br J Dermatol"},{"key":"bib36-20230923","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1136\/ard.20.1.36","article-title":"Quantitative and qualitative analysis of joint stiffness in normal subjects and in patients with connective tissue diseases","volume":"20","year":"1961","journal-title":"Ann Rheum Dis"}],"container-title":["Advances in Skin &amp; Wound Care"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00129334-201803000-00005","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,23]],"date-time":"2023-09-23T10:09:08Z","timestamp":1695463748000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00129334-201803000-00005"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,3]]},"references-count":33,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2018]]}},"URL":"https:\/\/doi.org\/10.1097\/01.asw.0000530067.37008.e8","relation":{},"ISSN":["1538-8654","1527-7941"],"issn-type":[{"value":"1538-8654","type":"electronic"},{"value":"1527-7941","type":"print"}],"subject":[],"published":{"date-parts":[[2018,3]]}}}