{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T14:58:08Z","timestamp":1780498688021,"version":"3.54.1"},"reference-count":17,"publisher":"Wiley","issue":"12","license":[{"start":{"date-parts":[[2005,12,1]],"date-time":"2005-12-01T00:00:00Z","timestamp":1133395200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"},{"start":{"date-parts":[[2005,12,1]],"date-time":"2005-12-01T00:00:00Z","timestamp":1133395200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/doi.wiley.com\/10.1002\/tdm_license_1.1"}],"funder":[{"DOI":"10.13039\/501100002924","name":"Federaci\u00f3n Espa\u00f1ola de Enfermedades Raras","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100002924","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["OVS"],"published-print":{"date-parts":[[2005,12]]},"abstract":"<jats:title>ABSTRACT:<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose.<\/jats:title>\n                    <jats:p>The purpose of this study was to evaluate the performance of quartic axicons for presbyopia compensation. The working principle relies on profiting the high depth of focus of the axicons to supplement the reduced accommodation amplitude of presbyopes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods.<\/jats:title>\n                    <jats:p>We present the design equations of a particular kind of axicon to compensate a general presbyopia condition using simultaneous vision. A rotationally symmetric polynomial of fourth\u2010order, corresponding to the well\u2010known Seidel spherical aberration term, was chosen as its refractive profile. To validate its performance, we computed the retinal images with Stiles\u2010Crawford apodization for a presbyopic eye compensated with this quartic axicon and compared them with those obtained without compensation or with other available solutions based on the simultaneous vision principle.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results.<\/jats:title>\n                    <jats:p>The quartic axicon provides an important improvement of the image quality for intermediate distance vision in comparison with conventional bifocal and trifocal solutions. The image quality, however, is still not optimum for all distances.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions.<\/jats:title>\n                    <jats:p>The results show the usefulness of the proposed approach and point out the need for developing further adapted optimizations.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/01.opx.0000192347.57764.4c","type":"journal-article","created":{"date-parts":[[2005,12,15]],"date-time":"2005-12-15T04:10:00Z","timestamp":1134619800000},"page":"1071-1078","source":"Crossref","is-referenced-by-count":37,"title":["Presbyopia Compensation with a Quartic Axicon"],"prefix":"10.1002","volume":"82","author":[{"given":"Jorge","family":"Ares","sequence":"first","affiliation":[{"name":"\u00c1rea de \u00d3ptica, Departamento de F\u00edsica Aplicada Universidade de Santiago de Compostela Compostela Galiza Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ram\u00f3n","family":"Flores","sequence":"additional","affiliation":[{"name":"\u00c1rea de \u00d3ptica, Departamento de F\u00edsica Aplicada Universidade de Santiago de Compostela Compostela Galiza Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Salvador","family":"Bar\u00e1","sequence":"additional","affiliation":[{"name":"\u00c1rea de \u00d3ptica, Departamento de F\u00edsica Aplicada Universidade de Santiago de Compostela Compostela Galiza Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zbigniew","family":"Jaroszewicz","sequence":"additional","affiliation":[{"name":"Institute of Applied Optics Warsaw Poland"},{"name":"National Institute of Telecommunications Warsaw Poland"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"311","published-online":{"date-parts":[[2005,12,1]]},"reference":[{"key":"e_1_2_7_2_1","first-page":"410","volume-title":"Clinical Manual of Contact Lenses, 2nd ed","author":"Bennett ES","year":"2000"},{"key":"e_1_2_7_3_1","volume-title":"Research and Development Treatises","author":"Jaroszewicz Z","year":"1997"},{"key":"e_1_2_7_4_1","unstructured":"De CarleJT.Bifocal Corneal Contact Lens. US Patent Re25 286. Nov 13 1962."},{"key":"e_1_2_7_5_1","doi-asserted-by":"crossref","first-page":"453","DOI":"10.1016\/S0021-5155(99)00109-4","article-title":"Design of computer\u2010generated hologram with ring focus for nonmechanical corneal trephination with Er:YAG laser in penetrating keratoplasty","volume":"43","author":"Langenbucher A","year":"1999","journal-title":"Jpn J Ophthalmol"},{"key":"e_1_2_7_6_1","doi-asserted-by":"crossref","first-page":"243","DOI":"10.1364\/OL.27.000243","article-title":"High\u2010resolution optical coherence tomography over a large depth range with an axicon lens","volume":"27","author":"Ding Z","year":"2002","journal-title":"Opt Lett"},{"key":"e_1_2_7_7_1","doi-asserted-by":"crossref","first-page":"975","DOI":"10.1117\/12.7973610","article-title":"Triangulation with expanded range of depth","volume":"24","author":"Bickel G","year":"1985","journal-title":"Opt Eng"},{"key":"e_1_2_7_8_1","doi-asserted-by":"crossref","first-page":"4838","DOI":"10.1364\/AO.43.004838","article-title":"Simple lens axicon","volume":"43","author":"Burvall A","year":"2004","journal-title":"Appl Opt"},{"key":"e_1_2_7_9_1","volume-title":"Visual Optics","author":"Emsley HH","year":"1952"},{"key":"e_1_2_7_10_1","doi-asserted-by":"crossref","first-page":"1611","DOI":"10.1364\/JOSAA.10.001611","article-title":"Parametric representation of Stiles\u2010Crawford functions: normal variation of peak location and directionality","volume":"10","author":"Applegate RA","year":"1993","journal-title":"J Opt Soc Am (A)"},{"key":"e_1_2_7_11_1","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1097\/00006324-197501000-00002","article-title":"The depth\u2010of\u2010focus of the human eye for Snellen letters","volume":"52","author":"Tucker J","year":"1975","journal-title":"Am J Optom Physiol Opt"},{"key":"e_1_2_7_12_1","doi-asserted-by":"crossref","first-page":"812","DOI":"10.1364\/JOSAA.16.000812","article-title":"Apodization by the Stiles\u2010Crawford effect moderates the visual impact of retinal image defocus","volume":"16","author":"Zhang X","year":"1999","journal-title":"J Opt Soc Am (A)"},{"key":"e_1_2_7_13_1","first-page":"36","article-title":"A method to predict refractive errors from wave aberration data","volume":"80","author":"Guirao A","year":"2003","journal-title":"Optom Vis Sci"},{"key":"e_1_2_7_14_1","first-page":"91","article-title":"The frequency response of a defocused optical system","volume":"231","author":"Hopkins HH","year":"1955","journal-title":"Proc R Soc London Ser (A)"},{"key":"e_1_2_7_15_1","volume-title":"Introduction to Fourier Optics","author":"Goodman JW","year":"1968"},{"key":"e_1_2_7_16_1","unstructured":"FreemanMH.Method and Contact Lenses for Treating Presbyopia. US patent 5 296 881. March 22 1994."},{"key":"e_1_2_7_17_1","first-page":"23","article-title":"Multifocal 101","volume":"14","author":"Stigemeier MJ","year":"1999","journal-title":"Contact Lens Spectrum"},{"key":"e_1_2_7_18_1","doi-asserted-by":"crossref","first-page":"812","DOI":"10.1097\/00006324-200312000-00011","article-title":"Predicting and assessing visual performance with multizone bifocal contact lenses","volume":"80","author":"Martin JA","year":"2003","journal-title":"Optom Vis Sci"}],"container-title":["Optometry and Vision Science"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1097\/01.opx.0000192347.57764.4c","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/full-xml\/10.1097\/01.opx.0000192347.57764.4c","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1097\/01.opx.0000192347.57764.4c","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,31]],"date-time":"2026-03-31T09:49:10Z","timestamp":1774950550000},"score":1,"resource":{"primary":{"URL":"https:\/\/onlinelibrary.wiley.com\/doi\/10.1097\/01.opx.0000192347.57764.4c"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005,12]]},"references-count":17,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2005,12]]}},"alternative-id":["10.1097\/01.opx.0000192347.57764.4c"],"URL":"https:\/\/doi.org\/10.1097\/01.opx.0000192347.57764.4c","archive":["Portico"],"relation":{},"ISSN":["1040-5488","1538-9235"],"issn-type":[{"value":"1040-5488","type":"print"},{"value":"1538-9235","type":"electronic"}],"subject":[],"published":{"date-parts":[[2005,12]]}}}