{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,4]],"date-time":"2025-09-04T14:12:13Z","timestamp":1756995133141},"reference-count":27,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2020,10]]},"abstract":"<jats:sec>\n            <jats:title>Purpose of review<\/jats:title>\n            <jats:p>Why is pulse oximetry a standard monitor, whereas tissue oximeter is not? Is this a double-standard treatment?<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Recent findings<\/jats:title>\n            <jats:p>There appears to be a lack of enthusiasm for a continual investigation into whether the use of pulse oximetry leads to reduced morbidity and mortality in acute care although there is no robust evidence attesting to its outcome benefits. In contrast, research investigating the outcome effectiveness of tissue oximetry-guided care is consistently ongoing. A recent randomized controlled trial involving 800 patients who underwent laparoscopic hysterectomy found that, although muscular tissue oxygen saturation-guided care did not reduce the overall occurrence of postoperative nausea and vomiting for all patients, it did reduce the occurrence of these symptoms in patients who had a body mass index \u226525. It was also observed that muscular tissue oxygen saturation increases when blood pressure falls following the administration of nicardipine. These studies highlight the persistence of interest in understanding the value of tissue oximetry in patient care.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Summary<\/jats:title>\n            <jats:p>Pulse oximetry and tissue oximetry are treated differently although neither monitor has robust evidence attesting to its outcome benefits. This difference may root in the difference in the physiology they monitor, the cost, the ease of use\/interpretation\/intervention and the relevance to patient safety and care quality. Pulse oxygen saturation represents a vital sign, whereas tissue oxygen saturation is likely a quality sign; however, further research endeavors are required to fully understand how to best use tissue oximetry.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/aco.0000000000000910","type":"journal-article","created":{"date-parts":[[2020,8,21]],"date-time":"2020-08-21T16:08:59Z","timestamp":1598026139000},"page":"619-625","source":"Crossref","is-referenced-by-count":8,"title":["Double standards: why is pulse oximetry standard care, whereas tissue oximetry is not?"],"prefix":"10.1097","volume":"33","author":[{"given":"Xu","family":"Zhao","sequence":"first","affiliation":[{"name":"Department of Anesthesiology, Yale University School of Medicine, New Haven, Connecticut, USA"},{"name":"Department of Anesthesiology, The Second Xiangya Hospital, Central South University, Changsha, Hunan Province"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Huaping","family":"Xiao","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Jiangxi Cancer Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Junying","family":"Cai","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology and Perioperative Medicine, The Second Affiliated Hospital of Nanchang University, Nanchang, Jiangxi Province, China"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lingzhong","family":"Meng","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Yale University School of Medicine, New Haven, Connecticut, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2020,8,19]]},"reference":[{"key":"R1-20230827","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1007\/BF00858362","article-title":"History of blood gas analysis. VII. Pulse oximetry","volume":"3","author":"Severinghaus","year":"1987","journal-title":"J Clin Monit"},{"key":"R2-20230827","doi-asserted-by":"crossref","first-page":"873","DOI":"10.1007\/978-1-4684-3291-6_88","article-title":"Continuous non invasive monitoring of human brain by near infrared spectroscopy","volume":"191","author":"Ferrari","year":"1985","journal-title":"Adv Exp Med Biol"},{"key":"R3-20230827","first-page":"599","article-title":"Physiology, intervention, and outcome: three critical questions about cerebral tissue oxygen saturation monitoring","volume":"84","author":"Meng","year":"2018","journal-title":"Miner Anestesiol"},{"key":"R4-20230827","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1093\/bja\/aer150","article-title":"Effect of phenylephrine and ephedrine bolus treatment on cerebral oxygenation in anaesthetized patients","volume":"107","author":"Meng","year":"2011","journal-title":"Br J Anaesth"},{"key":"R5-20230827","article-title":"Calcium channel blockers in acute care: the links and missing links between hemodynamic effects and outcome evidence","author":"Wang","year":"2020","journal-title":"Am J Cardiovasc Drugs"},{"key":"R6-20230827","doi-asserted-by":"crossref","first-page":"1198","DOI":"10.1097\/ALN.0000000000000872","article-title":"Cardiac output and cerebral blood flowthe integrated regulation of brain perfusion in adult humans","volume":"123","author":"Meng","year":"2015","journal-title":"Anesthesiology"},{"key":"R7-20230827","doi-asserted-by":"crossref","first-page":"1606","DOI":"10.1007\/s001340101064","article-title":"Accuracy of pulse oximetry in the intensive care unit","volume":"27","author":"Louw","year":"2001","journal-title":"Intensive Care Med"},{"key":"R8-20230827","doi-asserted-by":"crossref","first-page":"427","DOI":"10.1053\/ajem.2000.7330","article-title":"The accuracy of pulse oximetry in the emergency department","volume":"18","author":"Lee","year":"2000","journal-title":"Am J Emerg Med"},{"key":"R9-20230827","doi-asserted-by":"crossref","first-page":"834","DOI":"10.1097\/ALN.0b013e31824c00d7","article-title":"Impact of extracranial contamination on regional cerebral oxygen saturation: a comparison of three cerebral oximetry technologies","volume":"116","author":"Davie","year":"2012","journal-title":"Anesthesiology"},{"key":"R10-20230827","doi-asserted-by":"crossref","first-page":"1825","DOI":"10.1177\/0271678X16667953","article-title":"Application of optical methods in the monitoring of traumatic brain injury: a review","volume":"36","author":"Weigl","year":"2016","journal-title":"J Cereb Blood Flow Metab"},{"key":"R11-20230827","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1097\/00000542-199303000-00007","article-title":"Randomized evaluation of pulse oximetry in 20,802 patients: II. Perioperative events and postoperative complications","volume":"78","author":"Moller","year":"1993","journal-title":"Anesthesiology"},{"key":"R12-20230827","doi-asserted-by":"crossref","first-page":"868","DOI":"10.1213\/01.ane.0000195583.76486.c4","article-title":"The impact of continuous pulse oximetry monitoring on intensive care unit admissions from a postsurgical care floor","volume":"102","author":"Ochroch","year":"2006","journal-title":"Anesth Analg"},{"key":"R13-20230827","first-page":"Cd002013","article-title":"Pulse oximetry for perioperative monitoring","author":"Pedersen","year":"2014","journal-title":"Cochrane Database Syst Rev"},{"key":"R14-20230827","doi-asserted-by":"crossref","first-page":"102","DOI":"10.4103\/0971-9784.109740","article-title":"Impact of monitoring cerebral oxygen saturation on the outcome of patients undergoing open heart surgery","volume":"16","author":"Mohandas","year":"2013","journal-title":"Ann Card Anaesth"},{"key":"R15-20230827","doi-asserted-by":"crossref","first-page":"447","DOI":"10.1093\/ejcts\/ezu193","article-title":"Influence of intraoperative cerebral oximetry monitoring on neurocognitive function after coronary artery bypass surgery: a randomized, prospective study","volume":"47","author":"Colak","year":"2015","journal-title":"Eur J Cardiothorac Surg"},{"key":"R16-20230827","doi-asserted-by":"crossref","first-page":"544","DOI":"10.5761\/atcs.oa.15-00118","article-title":"The effects of near-infrared spectroscopy on the neurocognitive functions in the patients undergoing coronary artery bypass grafting with asymptomatic carotid artery disease: a randomized prospective study","volume":"21","author":"Kara","year":"2015","journal-title":"Ann Thorac Cardiovasc Surg"},{"key":"R17-20230827","doi-asserted-by":"crossref","first-page":"826","DOI":"10.1097\/ALN.0000000000001029","article-title":"Cerebral oximetry monitoring to maintain normal cerebral oxygen saturation during high-risk cardiac surgery: a randomized controlled feasibility trial","volume":"124","author":"Deschamps","year":"2016","journal-title":"Anesthesiology"},{"key":"R18-20230827","doi-asserted-by":"crossref","first-page":"1456","DOI":"10.1111\/anae.14056","article-title":"Cerebral oximetry and postoperative delirium after cardiac surgery: a randomised, controlled trial","volume":"72","author":"Lei","year":"2017","journal-title":"Anaesthesia"},{"key":"R19-20230827","doi-asserted-by":"crossref","first-page":"1172","DOI":"10.1053\/j.jvca.2019.10.054","article-title":"Intraoperative optimization of both depth of anesthesia and cerebral oxygenation in elderly patients undergoing coronary artery bypass graft surgery: a randomized controlled pilot trial","volume":"34","author":"Kunst","year":"2020","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"R20-20230827","doi-asserted-by":"crossref","first-page":"943","DOI":"10.1016\/j.jtcvs.2019.03.036","article-title":"Optimizing cerebral oxygenation in cardiac surgery: a randomized controlled trial examining neurocognitive and perioperative outcomes","volume":"159","author":"Uysal","year":"2019","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R21-20230827","doi-asserted-by":"crossref","first-page":"81","DOI":"10.18051\/UnivMed.2019.v38.81-89","article-title":"Brain oximetry is not a good monitor on reducing neurological complications after cardiac surgery","volume":"38","author":"Zavareh","year":"2019","journal-title":"Univ Med"},{"key":"R22-20230827","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1213\/01.ane.0000246814.29362.f4","article-title":"Monitoring brain oxygen saturation during coronary bypass surgery: a randomized, prospective study","volume":"104","author":"Murkin","year":"2007","journal-title":"Anesth Analg"},{"key":"R23-20230827","doi-asserted-by":"crossref","first-page":"384","DOI":"10.1093\/bja\/aex182","article-title":"Randomized trial of near-infrared spectroscopy for personalized optimization of cerebral tissue oxygenation during cardiac surgery","volume":"119","author":"Rogers","year":"2017","journal-title":"Br J Anaesth"},{"key":"R24-20230827","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1186\/1749-8090-8-145","article-title":"Monitoring of brain oxygen saturation (INVOS) in a protocol to direct blood transfusions during cardiac surgery: a prospective randomized clinical trial","volume":"8","author":"Vretzakis","year":"2013","journal-title":"J Cardiothorac Surg"},{"key":"R25-20230827","doi-asserted-by":"crossref","first-page":"318","DOI":"10.1097\/ALN.0000000000003305","article-title":"Muscular tissue oxygen saturation and posthysterectomy nausea and vomiting: the iMODIPONV randomized controlled trial","volume":"133","author":"Li","year":"2020","journal-title":"Anesthesiology"},{"key":"R26-20230827","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1186\/s12871-019-0740-8","article-title":"Tourniquet-induced tissue hypoxia characterized by near-infrared spectroscopy during ankle surgery: an observational study","volume":"19","author":"Lin","year":"2019","journal-title":"BMC Anesthesiol"},{"key":"R27-20230827","doi-asserted-by":"crossref","first-page":"597","DOI":"10.1007\/s10877-018-0193-5","article-title":"Muscular tissue oxygen saturation during robotic hysterectomy and postoperative nausea and vomiting: exploring the potential therapeutic thresholds","volume":"33","author":"Li","year":"2019","journal-title":"J Clin Monit Comput"}],"container-title":["Current Opinion in Anaesthesiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/ACO.0000000000000910","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,27]],"date-time":"2023-08-27T03:43:04Z","timestamp":1693107784000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/ACO.0000000000000910"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,8,19]]},"references-count":27,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/aco.0000000000000910","relation":{},"ISSN":["0952-7907","1473-6500"],"issn-type":[{"value":"0952-7907","type":"print"},{"value":"1473-6500","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,8,19]]}}}