{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,15]],"date-time":"2026-05-15T02:42:16Z","timestamp":1778812936168,"version":"3.51.4"},"reference-count":22,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,10]]},"abstract":"<jats:sec>\n            <jats:title>Purpose of review<\/jats:title>\n            <jats:p>Ultrasound has become the standard imaging technique for regional anesthesia. Traditional guidelines discourage direct needle-nerve contact to prevent fascicle impalement and nerve injury from high-pressure injections. However, despite its widespread usage, efficacy remains inconsistent, with significant rates of secondary continuous block failure and unchanged side-effect profiles. Current ultrasound (8\u201314 MHz) provides insufficient resolution to reliably differentiate nerve structures from surrounding tissues, particularly in patients with conditions affecting tissue differentiation, such as rheumatoid arthritis.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Recent findings<\/jats:title>\n            <jats:p>Recent microultrasound studies (&gt;30 MHz) challenge conventional paradigms by revealing multiple fascicles and distinct adipose tissue compartments that are critical for anesthetic distribution. These studies indicate that the needle-tip location relative to adipose tissue, rather than mere proximity to nerves, dictates clinical outcomes. Intraneural injections into adipose compartments seem to be common and clinically beneficial, in contrast to traditional beliefs that associate intraneural injections exclusively with harm.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Summary<\/jats:title>\n            <jats:p>Innovative technologies such as ultra-high-resolution ultrasound and fiber-optic needle integration promise significantly improved visualization and accurate pressure monitoring for precise anesthetic placement. Until these technologies mature, a combined approach that utilizes ultrasound for anatomical guidance and nerve stimulation to confirm accurate needle and catheter positioning is recommended to enhance block reliability and patient safety.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/aco.0000000000001534","type":"journal-article","created":{"date-parts":[[2025,6,10]],"date-time":"2025-06-10T15:00:10Z","timestamp":1749567610000},"page":"652-659","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":5,"title":["High-definition ultrasound in regional anesthesia"],"prefix":"10.1097","volume":"38","author":[{"given":"Graeme A.","family":"McLeod","sequence":"first","affiliation":[{"name":"Department of Anaesthesia, NHS Tayside"},{"name":"School of Medicine, University of Dundee, Dundee"},{"name":"School of Engineering and Physical Sciences, Heriot-Watt University, Edinburgh, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Miguel A.","family":"Reina","sequence":"additional","affiliation":[{"name":"CEU San Pablo University School of Medicine"},{"name":"Department of Anesthesiology, Madrid-Montepr\u00edncipe University Hospital, Madrid, Spain"},{"name":"Department of Anesthesiology, University of Florida College of Medicine, Gainesville, Florida, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andr\u00e9 P.","family":"Boezaart","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, University of Florida College of Medicine, Gainesville, Florida, USA"},{"name":"Lumina Health, Surrey, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2025,5,30]]},"reference":[{"key":"R1-20250905","doi-asserted-by":"crossref","first-page":"401","DOI":"10.1097\/AAP.0000000000000286","article-title":"The second ASRA practice advisory on neurologic complications associated with regional anesthesia and pain medicine: executive summary 2015.","volume":"40","author":"Neal","year":"2015","journal-title":"Reg Anesth Pain Med"},{"key":"R2-20250905","doi-asserted-by":"crossref","first-page":"479","DOI":"10.1097\/AAP.0000000000000125","article-title":"Pathophysiology and etiology of nerve injury following peripheral nerve blockade.","volume":"40","author":"Brull","year":"2015","journal-title":"Reg Anesth Pain Med"},{"key":"R3-20250905","doi-asserted-by":"crossref","first-page":"1084","DOI":"10.1111\/anae.13098","article-title":"A systematic review and meta-analysis of ultrasound versus electrical stimulation for peripheral nerve location and blockade.","volume":"70","author":"Munirama","year":"2015","journal-title":"Anaesthesia"},{"key":"R4-20250905","doi-asserted-by":"crossref","first-page":"794","DOI":"10.1016\/j.mpaic.2023.09.011","article-title":"Physics of ultrasound.","volume":"24","author":"Patey","year":"2023","journal-title":"Anaest Intens Care Med"},{"key":"R5-20250905","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1111\/anae.15274","article-title":"The use of artificial intelligence and robotics in regional anaesthesia.","volume":"76","author":"McKendrick","year":"2021","journal-title":"Anaesthesia"},{"key":"R6-20250905","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1111\/anae.13708","article-title":"The feasibility of micro-ultrasound as a tool to image peripheral nerves.","volume":"72","author":"Chandra","year":"2017","journal-title":"Anaesthesia"},{"key":"R7-20250905","doi-asserted-by":"crossref","first-page":"854","DOI":"10.1016\/j.bja.2017.12.035","article-title":"Investigation into the visual perceptive ability of anaesthetists during ultrasound-guided interscalene and femoral blocks conducted on soft embalmed cadavers: a randomised single-blind study.","volume":"120","author":"Mustafa","year":"2018","journal-title":"Br J Anaesth"},{"key":"R8-20250905","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1016\/j.bja.2021.03.036","article-title":"Real-time visualisation of peripheral nerve trauma during subepineural injection in pig brachial plexus using micro-ultrasound.","volume":"127","author":"Chandra","year":"2021","journal-title":"Br J Anaesth"},{"key":"R9-20250905","doi-asserted-by":"crossref","first-page":"501","DOI":"10.1136\/rapm-2022-104282","article-title":"Accuracy of injection pressure measurement at peripheral nerves using high-resolution 40 MHz ultrasound in an anesthetized porcine model.","volume":"48","author":"McLeod","year":"2023","journal-title":"Reg Anesth Pain Med"},{"key":"R10-20250905","doi-asserted-by":"crossref","first-page":"279","DOI":"10.1136\/rapm-2018-100087","article-title":"Our best anesthetic blocks are probably related to unintentional and unnoticed intraneural injection.","volume":"44","author":"Boezaart","year":"2019","journal-title":"Reg Anesth Pain Med"},{"key":"R11-20250905","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1002\/ca.23442","article-title":"Another (Internal) epineurium: beyond the anatomical barriers of nerves.","volume":"33","author":"Reina","year":"2020","journal-title":"Clin Anat"},{"key":"R12-20250905","doi-asserted-by":"crossref","first-page":"1007","DOI":"10.1097\/ALN.0000000000002647","article-title":"Extrafasicular and intraperineural, but no endoneural, spread after deliberate intraneural injections in a cadaveric study.","volume":"130","author":"Reina","year":"2019","journal-title":"Anesthesiology"},{"key":"R13-20250905","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1097\/AAP.0b013e31819a2795","article-title":"Structural injury to the human sciatic nerve after intraneural needle insertion.","volume":"34","author":"Sala-Blanch","year":"2009","journal-title":"Reg Anesth Pain Med"},{"key":"R14-20250905","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1097\/00115550-200409000-00005","article-title":"Combination of intraneural injection and high injection pressure leads to fascicular injury and neurologic deficits in dogs.","volume":"29","author":"Hadzic","year":"2004","journal-title":"Reg Anesth Pain Med"},{"key":"R15-20250905","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1111\/j.1399-6576.2006.01169.x","article-title":"Neurologic and histologic outcome after intraneural injections of lidocaine in canine sciatic nerves.","volume":"51","author":"Kapur","year":"2007","journal-title":"Acta Anaesthesiol Scand"},{"key":"R16-20250905","doi-asserted-by":"crossref","first-page":"677","DOI":"10.1136\/rapm-2023-104820","article-title":"Identification of spread after deliberated intraneural injection in five mammalian species: not all animal models and needle types are valid for studying the effect of intraneural injections in humans.","volume":"49","author":"Server","year":"2024","journal-title":"Reg Anesth Pain Med"},{"key":"R17-20250905","doi-asserted-by":"crossref","first-page":"545","DOI":"10.1016\/j.bja.2024.11.030","article-title":"Risk of intrafascicular spread after deliberate ex vivo intraneural injections of brachial plexus nerve roots.","volume":"134","author":"Sala-Blanch","year":"2025","journal-title":"Br J Anaesth"},{"key":"R18-20250905","doi-asserted-by":"crossref","DOI":"10.1136\/rapm-2024-105721","article-title":"Peripheral nerve microanatomy: new insights into possible mechanisms for block success.","author":"McLeod","year":"2024","journal-title":"Reg Anesth Pain Med"},{"key":"R19-20250905","doi-asserted-by":"crossref","first-page":"368","DOI":"10.1016\/j.bja.2019.04.060","article-title":"Validity and reliability of metrics for translation of regional anaesthesia performance from cadavers to patients.","volume":"123","author":"McLeod","year":"2019","journal-title":"Br J Anaesth"},{"key":"R20-20250905","first-page":"603","article-title":"Injection pressure monitoring during peripheral nerve blocks: from bench to operating theatre.","volume":"39","author":"Capdevila","year":"2020","journal-title":"Anaesth Crit Care Pain Med"},{"key":"R21-20250905","first-page":"597","article-title":"Real-time continuous monitoring of injection pressure during peripheral nerve blocks in fresh cadavers.","volume":"39","author":"Capdevila","year":"2020","journal-title":"Anaesth Crit Care Pain Med"},{"key":"R22-20250905","article-title":"Real time continuous monitoring of injection pressure at the needle tip is better than ultrasound in early detecting intraneural injection.","author":"Dossi","year":"2025","journal-title":"Reg Anesth Pain Med"}],"container-title":["Current Opinion in Anaesthesiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/ACO.0000000000001534","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,5]],"date-time":"2025-09-05T12:02:31Z","timestamp":1757073751000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/ACO.0000000000001534"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,30]]},"references-count":22,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/aco.0000000000001534","relation":{},"ISSN":["0952-7907","1473-6500"],"issn-type":[{"value":"0952-7907","type":"print"},{"value":"1473-6500","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,30]]}}}