{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,17]],"date-time":"2026-09-17T23:58:48Z","timestamp":1789689528038,"version":"4.0.1"},"reference-count":29,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2020,6]]},"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>Management of acute respiratory failure by noninvasive ventilation is often associated with asynchronies, like autotriggering or delayed cycling, incurred by leaks from the interface. These events are likely to impair patient\u2019s tolerance and to compromise noninvasive ventilation. The development of methods for easy detection and monitoring of asynchronies is therefore necessary. The authors describe two new methods to detect patient\u2013ventilator asynchronies, based on ultrasound analysis of diaphragm excursion or thickening combined with airway pressure. The authors tested these methods in a diagnostic accuracy study.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>Fifteen healthy subjects were placed under noninvasive ventilation and subjected to artificially induced leaks in order to generate the main asynchronies (autotriggering or delayed cycling) at event-appropriate times of the respiratory cycle. Asynchronies were identified and characterized by conjoint assessment of ultrasound records and airway pressure waveforms; both were visualized on the ultrasound screen. The performance and accuracy of diaphragm excursion and thickening to detect each asynchrony were compared with a \u201ccontrol method\u201d of flow\/pressure tracings alone, and a \u201cworking standard method\u201d combining flow, airway pressure, and diaphragm electromyography signals analyses.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>Ultrasound recordings were performed for the 15 volunteers, unlike electromyography recordings which could be collected in only 9 of 15 patients (60%). Autotriggering was correctly identified by continuous recording of electromyography, excursion, thickening, and flow\/pressure tracings with sensitivity of 93% (95% CI, 89\u201397%), 94% (95% CI, 91\u201398%), 91% (95% CI, 87\u201396%), and 79% (95% CI, 75\u201384%), respectively. Delayed cycling was detected by electromyography, excursion, thickening, and flow\/pressure tracings with sensitivity of 84% (95% CI, 77\u201390%), 86% (95% CI, 80\u201393%), 89% (95% CI, 83\u201394%), and 67% (95% CI, 61\u201373%), respectively.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>Ultrasound is a simple, bedside adjustable, clinical tool to detect the majority of patient\u2013ventilator asynchronies associated with noninvasive ventilation leaks, provided that it is possible to visualize the airway pressure curve on the ultrasound machine screen. Ultrasound detection of autotriggering and delayed cycling is more accurate than isolated observation of pressure and flow tracings, and more feasible than electromyogram.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Editor\u2019s Perspective<\/jats:title>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>What We Already Know about This Topic<\/jats:title>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>What This Article Tells Us That Is New<\/jats:title>\n          <\/jats:sec>","DOI":"10.1097\/aln.0000000000003239","type":"journal-article","created":{"date-parts":[[2020,3,20]],"date-time":"2020-03-20T10:29:36Z","timestamp":1584700176000},"page":"1494-1502","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":19,"title":["Diagnostic Accuracy of Diaphragm Ultrasound in Detecting and Characterizing Patient\u2013Ventilator Asynchronies during Noninvasive Ventilation"],"prefix":"10.1097","volume":"132","author":[{"given":"Emmanuel","family":"Vivier","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anne Fleur","family":"Haudebourg","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philippe","family":"Le Corvoisier","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Armand","family":"Mekontso Dessap","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guillaume","family":"Carteaux","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20241219","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1186\/s13613-016-0179-8","article-title":"Patterns of diaphragm function in critically ill patients receiving prolonged mechanical ventilation: A prospective longitudinal study.","volume":"6","year":"2016","journal-title":"Ann Intensive Care"},{"key":"R2-20241219","doi-asserted-by":"crossref","first-page":"1718","DOI":"10.1007\/s00134-001-1114-4","article-title":"Predictors of failure of noninvasive positive pressure ventilation in patients with acute hypoxemic respiratory failure: A multi-center study.","volume":"27","year":"2001","journal-title":"Intensive Care Med"},{"key":"R3-20241219","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1378\/chest.11-2279","article-title":"Patient-ventilator asynchrony during noninvasive ventilation: A bench and clinical study.","volume":"142","year":"2012","journal-title":"Chest"},{"key":"R4-20241219","doi-asserted-by":"crossref","first-page":"840","DOI":"10.1007\/s00134-009-1416-5","article-title":"Patient-ventilator asynchrony during noninvasive ventilation for acute respiratory failure: A multicenter study.","volume":"35","year":"2009","journal-title":"Intensive Care Med"},{"key":"R5-20241219","doi-asserted-by":"crossref","first-page":"1887","DOI":"10.1007\/s00134-001-1146-9","article-title":"Mask mechanics and leak dynamics during noninvasive pressure support ventilation: A bench study.","volume":"27","year":"2001","journal-title":"Intensive Care Med"},{"key":"R6-20241219","article-title":"Efficacy of ventilator waveform observation for detection of patient-ventilator asynchrony during NIV: A multicentre study.","volume":"3","year":"2017","journal-title":"ERJ Open Res"},{"key":"R7-20241219","doi-asserted-by":"crossref","first-page":"2053","DOI":"10.1007\/s00134-010-1994-2","article-title":"Performance of noninvasive ventilation algorithms on ICU ventilators during pressure support: A clinical study.","volume":"36","year":"2010","journal-title":"Intensive Care Med"},{"key":"R8-20241219","doi-asserted-by":"crossref","first-page":"796","DOI":"10.1007\/s00134-012-2547-7","article-title":"Diaphragm ultrasonography to estimate the work of breathing during noninvasive ventilation.","volume":"38","year":"2012","journal-title":"Intensive Care Med"},{"key":"R9-20241219","doi-asserted-by":"crossref","first-page":"801","DOI":"10.1007\/s00134-013-2823-1","article-title":"Sonographic evaluation of the diaphragm in critically ill patients. Technique and clinical applications.","volume":"39","year":"2013","journal-title":"Intensive Care Med"},{"key":"R10-20241219","doi-asserted-by":"crossref","first-page":"907","DOI":"10.1002\/sim.906","article-title":"Simultaneous comparison of sensitivity and specificity of two tests in the paired design: A straightforward graphical approach.","volume":"20","year":"2001","journal-title":"Stat Med"},{"key":"R12-20241219","doi-asserted-by":"crossref","first-page":"e3999","DOI":"10.1136\/bmj.e3999","article-title":"Interpreting diagnostic accuracy studies for patient care.","volume":"345","year":"2012","journal-title":"BMJ"},{"key":"R13-20241219","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1002\/sim.2929","article-title":"Evaluating the added predictive ability of a new marker: From area under the ROC curve to reclassification and beyond.","volume":"27","year":"2008","journal-title":"Stat Med"},{"key":"R14-20241219","doi-asserted-by":"crossref","first-page":"447","DOI":"10.1177\/0272989X9701700410","article-title":"Application of treatment thresholds to diagnostic-test evaluation: An alternative to the comparison of areas under receiver operating characteristic curves.","volume":"17","year":"1997","journal-title":"Med Decis Making"},{"key":"R15-20241219","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1016\/j.jbi.2014.02.013","article-title":"Sample size estimation in diagnostic test studies of biomedical informatics.","volume":"48","year":"2014","journal-title":"J Biomed Inform"},{"key":"R16-20241219","doi-asserted-by":"crossref","first-page":"1592","DOI":"10.1378\/chest.112.6.1592","article-title":"Patient-ventilator trigger asynchrony in prolonged mechanical ventilation.","volume":"112","year":"1997","journal-title":"Chest"},{"key":"R17-20241219","doi-asserted-by":"crossref","first-page":"1515","DOI":"10.1007\/s00134-006-0301-8","article-title":"Patient-ventilator asynchrony during assisted mechanical ventilation.","volume":"32","year":"2006","journal-title":"Intensive Care Med"},{"key":"R18-20241219","doi-asserted-by":"crossref","first-page":"633","DOI":"10.1007\/s00134-015-3692-6","article-title":"Asynchronies during mechanical ventilation are associated with mortality.","volume":"41","year":"2015","journal-title":"Intensive Care Med"},{"key":"R19-20241219","first-page":"2740","article-title":"Ineffective triggering predicts increased duration of mechanical ventilation.","volume":"37","year":"2009","journal-title":"Crit Care Med"},{"key":"R20-20241219","article-title":"Patient-ventilator asynchronies during mechanical ventilation: Current knowledge and research priorities.","volume":"7","year":"2019","journal-title":"Intensive Care Med Exp"},{"key":"R21-20241219","doi-asserted-by":"crossref","first-page":"1477","DOI":"10.1007\/s00134-008-1121-9","article-title":"Reduction of patient-ventilator asynchrony by reducing tidal volume during pressure-support ventilation.","volume":"34","year":"2008","journal-title":"Intensive Care Med"},{"key":"R22-20241219","doi-asserted-by":"crossref","first-page":"503","DOI":"10.1097\/CCM.0000000000001418","article-title":"Comparison between neurally adjusted ventilatory assist and pressure support ventilation levels in terms of respiratory effort.","volume":"44","year":"2016","journal-title":"Crit Care Med"},{"key":"R23-20241219","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1186\/s13054-015-0763-6","article-title":"Neurally adjusted ventilatory assist and proportional assist ventilation both improve patient-ventilator interaction.","volume":"19","year":"2015","journal-title":"Crit Care"},{"key":"R24-20241219","doi-asserted-by":"crossref","first-page":"2177","DOI":"10.1097\/CCM.0b013e31828c2d7a","article-title":"Impact of ventilator adjustment and sedation-analgesia practices on severe asynchrony in patients ventilated in assist-control mode.","volume":"41","year":"2013","journal-title":"Crit Care Med"},{"key":"R25-20241219","doi-asserted-by":"crossref","first-page":"1048","DOI":"10.1097\/01.CCM.0000260055.64235.7C","article-title":"Patient-ventilator interaction and sleep in mechanically ventilated patients: Pressure support versus proportional assist ventilation.","volume":"35","year":"2007","journal-title":"Crit Care Med"},{"key":"R26-20241219","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1016\/j.jcrc.2008.08.011","article-title":"Observational study of patient-ventilator asynchrony and relationship to sedation level.","volume":"24","year":"2009","journal-title":"J Crit Care"},{"key":"R27-20241219","doi-asserted-by":"crossref","first-page":"2452","DOI":"10.1097\/CCM.0b013e318225753c","article-title":"Efficacy of ventilator waveforms observation in detecting patient-ventilator asynchrony.","volume":"39","year":"2011","journal-title":"Crit Care Med"},{"key":"R28-20241219","first-page":"PA3016","article-title":"Measuring respiratory function using a novel device in healthy volunteers.","volume":"50","year":"2017","journal-title":"Eur Respir J"},{"key":"R29-20241219","doi-asserted-by":"crossref","first-page":"500","DOI":"10.1136\/thx.49.5.500","article-title":"Ultrasound assessment of normal hemidiaphragmatic movement: Relation to inspiratory volume.","volume":"49","year":"1994","journal-title":"Thorax"},{"key":"R30-20241219","doi-asserted-by":"crossref","first-page":"R239","DOI":"10.1186\/cc13063","article-title":"An automated and standardized neural index to quantify patient-ventilator interaction.","volume":"17","year":"2013","journal-title":"Crit Care"}],"container-title":["Anesthesiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/pubs.asahq.org\/anesthesiology\/article-pdf\/132\/6\/1494\/518127\/20200600_0-00031.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/anesthesiology.pubs.asahq.org\/article.aspx?doi=10.1097\/ALN.0000000000003239","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,1,3]],"date-time":"2025-01-03T14:08:29Z","timestamp":1735913309000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/ALN.0000000000003239"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,6]]},"references-count":29,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/aln.0000000000003239","relation":{},"ISSN":["0003-3022"],"issn-type":[{"value":"0003-3022","type":"print"}],"subject":[],"published":{"date-parts":[[2020,6]]}}}