{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,11]],"date-time":"2026-06-11T17:26:20Z","timestamp":1781198780836,"version":"3.54.1"},"reference-count":23,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2021,1]]},"abstract":"<jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>Disease severity in coronavirus disease 2019 (COVID-19) may be associated with inoculation dose. This has triggered interest in intubation barrier devices to block droplet exposure; however, aerosol protection with these devices is not known. This study hypothesized that barrier devices reduce aerosol outside of the barrier.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>Aerosol containment in closed, semiclosed, semiopen, and open barrier devices was investigated: (1) \u201cglove box\u201d sealed with gloves and caudal drape, (2) \u201cdrape tent\u201d with a drape placed over a frame, (3) \u201cslit box\u201d with armholes and caudal end covered by vinyl slit diaphragms, (4) original \u201caerosol box,\u201d (5) collapsible \u201cinterlocking box,\u201d (6) \u201csimple drape\u201d over the patient, and (7) \u201cno barrier.\u201d Containment was investigated by (1) vapor instillation at manikin\u2019s right arm with video-assisted visual evaluation and (2) submicrometer ammonium sulfate aerosol particles ejected through the manikin\u2019s mouth with ventilation and coughs. Samples were taken from standardized locations inside and around the barriers using a particle counter and a mass spectrometer. Aerosol evacuation from the devices was measured using standard hospital suction, a surgical smoke evacuator, and a Shop-Vac.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>Vapor experiments demonstrated leakage <jats:italic toggle=\"yes\">via<\/jats:italic> arm holes and edges. Only closed and semiclosed devices and the aerosol box reduced aerosol particle counts (median [25th, 75th percentile]) at the operator\u2019s mouth compared to no barrier (combined median 29 [\u221211, 56], n = 5 <jats:italic toggle=\"yes\">vs<\/jats:italic>. 157 [151, 166], n = 5). The other barrier devices provided less reduction in particle counts (133 [128, 137], n = 5). Aerosol evacuation to baseline required 15 min with standard suction and the Shop-Vac and 5 min with a smoke evacuator.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>Barrier devices may reduce exposure to droplets and aerosol. With meticulous tucking, the glove box and drape tent can retain aerosol during airway management. Devices that are not fully enclosed may direct aerosol toward the laryngoscopist. Aerosol evacuation reduces aerosol content inside fully enclosed devices. Barrier devices must be used in conjunction with body-worn personal protective equipment.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Editor\u2019s Perspective<\/jats:title>\n            <jats:sec>\n              <jats:title>What We Already Know about This Topic<\/jats:title>\n            <\/jats:sec>\n            <jats:sec>\n              <jats:title>What This Article Tells Us That Is New<\/jats:title>\n            <\/jats:sec>\n          <\/jats:sec>","DOI":"10.1097\/aln.0000000000003597","type":"journal-article","created":{"date-parts":[[2020,10,30]],"date-time":"2020-10-30T15:32:21Z","timestamp":1604071941000},"page":"61-71","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":24,"title":["Aerosol Retention Characteristics of Barrier Devices"],"prefix":"10.1097","volume":"134","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4358-7887","authenticated-orcid":false,"given":"Richard L.","family":"Fidler","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher R.","family":"Niedek","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Justin J.","family":"Teng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mary E.","family":"Sturgeon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qi","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David L.","family":"Robinowitz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan","family":"Hirsch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2020,10,30]]},"reference":[{"key":"R1-20251014","doi-asserted-by":"crossref","first-page":"1346","DOI":"10.1097\/ALN.0000000000003303","article-title":"COVID-19 infection: Implications for perioperative and critical care physicians.","volume":"132","author":"Greenland","year":"2020","journal-title":"Anesthesiology."},{"key":"R2-20251014","doi-asserted-by":"crossref","first-page":"656","DOI":"10.1016\/S1473-3099(20)30232-2","article-title":"Viral dynamics in mild and severe cases of COVID-19.","volume":"20","author":"Liu","year":"2020","journal-title":"Lancet Infect Dis."},{"key":"R3-20251014","doi-asserted-by":"crossref","first-page":"1957","DOI":"10.1056\/NEJMc2007589","article-title":"Barrier enclosure during endotracheal intubation.","volume":"382","author":"Canelli","year":"2020","journal-title":"N Engl J Med."},{"key":"R4-20251014","doi-asserted-by":"crossref","first-page":"e179","DOI":"10.1016\/j.bja.2020.04.059","article-title":"A multipurpose portable negative air flow isolation chamber for aerosol-generating procedures during the COVID-19 pandemic.","volume":"125","author":"Cubillos","year":"2020","journal-title":"Br J Anaesth."},{"key":"R5-20251014","first-page":"1","article-title":"Clear plastic drapes may be effective at limiting aerosolization and droplet spray during extubation: Implications for COVID-19.","author":"Matava","year":"2020","journal-title":"Can J Anaesth."},{"key":"R6-20251014","article-title":"Intubation boxes: An extra layer of safety or a false sense of security?","author":"Turer","year":"2020","journal-title":"STAT News."},{"key":"R7-20251014","doi-asserted-by":"crossref","first-page":"e135","DOI":"10.1213\/ANE.0000000000004983","article-title":"Caution regarding enclosures for airway procedures.","volume":"131","author":"Jain","year":"2020","journal-title":"Anesth Analg."},{"key":"R9-20251014","doi-asserted-by":"crossref","first-page":"S102","DOI":"10.1016\/j.ajic.2016.06.003","article-title":"Airborne spread of infectious agents in the indoor environment.","volume":"44","author":"Wei","year":"2016","journal-title":"Am J Infect Control."},{"key":"R10-20251014","doi-asserted-by":"crossref","first-page":"537","DOI":"10.1017\/jfm.2014.88","article-title":"Violent expiratory events: On coughing and sneezing.","volume":"745","author":"Bourouiba","year":"2014","journal-title":"J Fluid Mech."},{"key":"R11-20251014","doi-asserted-by":"crossref","first-page":"1564","DOI":"10.1056\/NEJMc2004973","article-title":"Aerosol and surface stability of SARS\u2013CoV-2 as compared with SARS\u2013CoV-1.","volume":"382","author":"van Doremalen","year":"2020","journal-title":"N Engl J Med."},{"key":"R12-20251014","doi-asserted-by":"crossref","first-page":"e1003205","DOI":"10.1371\/journal.ppat.1003205","article-title":"Influenza virus aerosols in human exhaled breath: Particle size, culturability, and effect of surgical masks.","volume":"9","author":"Milton","year":"2013","journal-title":"PLoS Pathog."},{"key":"R13-20251014","doi-asserted-by":"crossref","first-page":"1628","DOI":"10.3201\/eid2607.200764","article-title":"COVID-19 outbreak associated with air conditioning in restaurant, Guangzhou, China, 2020.","volume":"26","author":"Lu","year":"2020","journal-title":"Emerg Infect Dis."},{"key":"R15-20251014","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1080\/027868200410840","article-title":"Development of an aerosol mass spectrometer for size and composition analysis of submicron particles.","volume":"33","author":"Jayne","year":"2000","journal-title":"Aerosol Science and Technology."},{"key":"R16-20251014","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1002\/mas.20115","article-title":"Chemical and microphysical characterization of ambient aerosols with the aerodyne aerosol mass spectrometer.","volume":"26","author":"Canagaratna","year":"2007","journal-title":"Mass Spectrom Rev."},{"key":"R17-20251014","doi-asserted-by":"crossref","first-page":"804","DOI":"10.1080\/02786826.2012.663948","article-title":"Soot particle aerosol mass spectrometer: Development, validation, and initial application.","volume":"46","author":"Onasch","year":"2012","journal-title":"Aerosol Science and Technology."},{"key":"R18-20251014","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1016\/j.ijms.2010.12.004","article-title":"Real-time aerosol mass spectrometry with millisecond resolution.","volume":"303","author":"Kimmel","year":"2011","journal-title":"International Journal of Mass Spectrometry."},{"key":"R19-20251014","doi-asserted-by":"crossref","first-page":"517","DOI":"10.1111\/j.1600-0668.2009.00619.x","article-title":"Flow dynamics and characterization of a cough.","volume":"19","author":"Gupta","year":"2009","journal-title":"Indoor Air."},{"key":"R20-20251014","doi-asserted-by":"crossref","first-page":"279","DOI":"10.1016\/S0166-4328(01)00297-2","article-title":"Controlling the false discovery rate in behavior genetics research.","volume":"125","author":"Benjamini","year":"2001","journal-title":"Behav Brain Res."},{"key":"R21-20251014","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1016\/S1473-3099(07)70029-4","article-title":"Transmission of influenza A in human beings.","volume":"7","author":"Brankston","year":"2007","journal-title":"Lancet Infect Dis."},{"key":"R22-20251014","doi-asserted-by":"crossref","first-page":"S783","DOI":"10.1098\/rsif.2009.0302.focus","article-title":"Aerosol transmission of influenza A virus: A review of new studies.","volume":"6","author":"Tellier","year":"2009","journal-title":"J R Soc Interface."},{"key":"R23-20251014","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1016\/j.jinf.2008.08.013","article-title":"Inactivation of influenza A viruses in the environment and modes of transmission: A critical review.","volume":"57","author":"Weber","year":"2008","journal-title":"J Infect."},{"key":"R24-20251014","article-title":"Measurement of airborne particle exposure during simulated tracheal intubation using various proposed aerosol containment devices during the COVID-19 pandemic.","author":"Simpson","year":"2008","journal-title":"Anaesthesia."},{"key":"R25-20251014","doi-asserted-by":"crossref","first-page":"1014","DOI":"10.1111\/anae.15115","article-title":"The aerosol box for intubation in coronavirus disease 2019 patients: An in-situ simulation crossover study.","volume":"75","author":"Begley","year":"2020","journal-title":"Anaesthesia."}],"container-title":["Anesthesiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/pubs.asahq.org\/anesthesiology\/article-pdf\/134\/1\/61\/513860\/20210100.0-00017.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/journals.lww.com\/10.1097\/ALN.0000000000003597","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,14]],"date-time":"2025-10-14T15:46:12Z","timestamp":1760456772000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/ALN.0000000000003597"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,10,30]]},"references-count":23,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.1097\/aln.0000000000003597","relation":{},"ISSN":["0003-3022","1528-1175"],"issn-type":[{"value":"0003-3022","type":"print"},{"value":"1528-1175","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,10,30]]}}}