{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,5]],"date-time":"2026-06-05T21:16:40Z","timestamp":1780694200948,"version":"3.54.1"},"reference-count":23,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019,8]]},"abstract":"<jats:sec>\n            <jats:title>Background:<\/jats:title>\n            <jats:p>Neonates are at a high risk for pressure ulcers (PU) due to skin immaturity and exposure to various medical devices. The prevalence of PU in the neonatal intensive care unit is estimated to be 23%, with 80% of those being related to medical devices, including electroencephalographic (EEG) electrodes. Proposed mechanisms involve prolonged pressure to the electrodes and chemical reactions to conductive agents.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Purpose:<\/jats:title>\n            <jats:p>The object of this quality improvement project was to reduce PU in neonates during continuous EEG (cEEG) monitoring by 50% within 12 months and 75% within 18 months. A secondary objective was to eliminate electrode-related infections by 12 months. Balancing measures included gestational age at the time of monitoring, integrity of the EEG setup, and cost effectiveness. The process measure was adherence to the skin-monitoring tool kit.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>A multiple Plan-Do-Study-Act cycle method was used. All neonates monitored with cEEG were included. The monitoring tool kit was used to document the condition of scalp and EEG electrodes before, during, and after cEEG.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>In the preproject period, 8.5% (9\/106) of monitored patients developed PU, and 22.2% (2\/9) of those developed infections. During the project period, 3.5% (7\/198) of monitored patients developed PU and no infections were observed. During monitoring, 21 patients showed skin irritation, and timely intervention resulted in resolution in more than 90% of the cases and prevented progression into PU. Silver\/silver chloride\u2013plated electrodes, when exposed to external heat sources, can cause burns, resembling PU.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Implications for Practice:<\/jats:title>\n            <jats:p>Intervention at the electrode level together with skin inspection successfully reduces PU in neonates. Silver\/silver chloride\u2013plated electrodes should be avoided in neonates.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Implications for Research:<\/jats:title>\n            <jats:p>Further research is needed to identify the optimal electrode for neonatal EEG.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/anc.0000000000000641","type":"journal-article","created":{"date-parts":[[2019,7,21]],"date-time":"2019-07-21T21:30:54Z","timestamp":1563744654000},"page":"262-274","source":"Crossref","is-referenced-by-count":13,"title":["Successful Reduction in Electrode-Related Pressure Ulcers During EEG Monitoring in Critically Ill Neonates"],"prefix":"10.1097","volume":"19","author":[{"given":"Ulrike","family":"Mietzsch","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kristin L.","family":"Cooper","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mandy L.","family":"Harris","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"issue":"2","key":"R1-20230812","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1080\/1086508X.2011.11079809","article-title":"Technical tips: electrode safety in pediatric prolonged EEG recordings","volume":"51","author":"Jarrar","year":"2011","journal-title":"Am J Electroneurodiagnostic Technol"},{"issue":"4","key":"R2-20230812","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1080\/1086508X.2006.11079592","article-title":"Mechanisms of electrode induced injury. Part 1: theory","volume":"46","author":"Stecker","year":"2006","journal-title":"Am J Electroneurodiagnostic Technol"},{"issue":"4","key":"R3-20230812","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1053\/siny.2000.0015","article-title":"Adhesives and emollients in the preterm infant","volume":"5","author":"Hoath","year":"2000","journal-title":"Semin Neonatol"},{"issue":"3","key":"R4-20230812","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1016\/S0022-3476(97)80060-1","article-title":"Disruption of barrier function in neonatal skin associated with adhesive removal","volume":"131","author":"Lund","year":"1997","journal-title":"J Pediatr"},{"issue":"2","key":"R5-20230812","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1159\/000076015","article-title":"Stratum corneum maturation. A review of neonatal skin function","volume":"17","author":"Chiou","year":"2004","journal-title":"Skin Pharmacol Physiol"},{"issue":"4","key":"R6-20230812","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1053\/siny.2000.0014","article-title":"Clinical consequences of an immature barrier","volume":"5","author":"Rutter","year":"2000","journal-title":"Semin Neonatol"},{"issue":"6","key":"R7-20230812","doi-asserted-by":"crossref","first-page":"483","DOI":"10.1111\/j.1600-0625.2009.01023.x","article-title":"Functional skin adaptation in infancy\u2014almost complete but not fully competent","volume":"19","author":"Fluhr","year":"2010","journal-title":"Exp Dermatol"},{"issue":"2","key":"R8-20230812","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1891\/0730-0832.34.2.126","article-title":"Neonatal pressure ulcer prevention","volume":"34","author":"Scheans","year":"2015","journal-title":"Neonatal Netw"},{"issue":"4","key":"R9-20230812","doi-asserted-by":"crossref","first-page":"208","DOI":"10.1097\/01.ASW.0000266646.43159.99","article-title":"Pressure ulcers in neonates and children: an NPUAP white paper","volume":"20","author":"Baharestani","year":"2007","journal-title":"Adv Skin Wound Care"},{"issue":"5","key":"R10-20230812","doi-asserted-by":"crossref","first-page":"358","DOI":"10.1111\/j.1742-481X.2010.00699.x","article-title":"Medical device related pressure ulcers in hospitalized patients","volume":"7","author":"Black","year":"2010","journal-title":"Int Wound J"},{"key":"R11-20230812","doi-asserted-by":"crossref","first-page":"7429","DOI":"10.1038\/srep07429","article-title":"Pressure ulcers in the hospitalized neonate: rates and risk factors","volume":"4","author":"Visscher","year":"2014","journal-title":"Sci Rep"},{"issue":"2","key":"R12-20230812","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1111\/apa.12869","article-title":"Overcoming the practical challenges of electroencephalography for very preterm infants in the neonatal intensive care unit","volume":"104","author":"Lloyd","year":"2015","journal-title":"Acta Paediatr"},{"issue":"1","key":"R13-20230812","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1080\/21646821.2016.1271197","article-title":"ASET Position Statement on skin safety during EEG procedures\u2014a guideline to improving outcome addendum: neonatal continuous EEG","volume":"57","year":"2017","journal-title":"Neurodiagn J"},{"issue":"4","key":"R14-20230812","first-page":"343","article-title":"National Pressure Ulcer Advisory Panel's updated pressure ulcer staging system","volume":"19","author":"Black","year":"2007","journal-title":"Dermatol Nurs"},{"issue":"6","key":"R15-20230812","doi-asserted-by":"crossref","first-page":"622","DOI":"10.1016\/j.clindermatol.2011.08.006","article-title":"Iatrogenic skin injury in hospitalized patients","volume":"29","author":"Cheng","year":"2011","journal-title":"Clin Dermatol"},{"issue":"5","key":"R16-20230812","doi-asserted-by":"crossref","first-page":"267","DOI":"10.1097\/NOR.0b013e3182a39caf","article-title":"Medical adhesives and patient safety: state of the science: consensus statements for the assessment, prevention, and treatment of adhesive-related skin injuries","volume":"32","author":"McNichol","year":"2013","journal-title":"Orthop Nurs"},{"issue":"3","key":"R17-20230812","doi-asserted-by":"crossref","first-page":"432","DOI":"10.1542\/peds.2015-1386","article-title":"Costs of venous thromboembolism, catheter-associated urinary tract infection, and pressure ulcer","volume":"136","author":"Goudie","year":"2015","journal-title":"Pediatrics"},{"issue":"6","key":"R18-20230812","doi-asserted-by":"crossref","first-page":"585","DOI":"10.1016\/j.pedn.2013.05.004","article-title":"Medical device-related hospital-acquired pressure ulcers in children: an integrative review","volume":"28","author":"Murray","year":"2013","journal-title":"J Pediat Nurs"},{"issue":"2","key":"R19-20230812","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1097\/WNP.0000000000000237","article-title":"Evaluation of dry sensors for neonatal EEG recordings","volume":"33","author":"Fridman","year":"2016","journal-title":"J Clin Neurophysiol"},{"issue":"6","key":"R20-20230812","doi-asserted-by":"crossref","first-page":"486","DOI":"10.1016\/j.ajic.2012.02.029","article-title":"Nurse staffing, burnout, and health care-associated infection","volume":"40","author":"Cimiotti","year":"2012","journal-title":"Am J Infect Control"},{"issue":"2","key":"R21-20230812","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1038\/jp.2017.146","article-title":"Association of nursing overtime, nurse staffing and unit occupancy with medical incidents and outcomes of very preterm infants","volume":"38","author":"Beltempo","year":"2018","journal-title":"J Perinatol"},{"issue":"16","key":"R22-20230812","doi-asserted-by":"crossref","first-page":"1987","DOI":"10.1001\/jama.288.16.1987","article-title":"Hospital nurse staffing and patient mortality, nurse burnout, and job dissatisfaction","volume":"288","author":"Aiken","year":"2002","journal-title":"JAMA"},{"issue":"4","key":"R23-20230812","doi-asserted-by":"crossref","first-page":"296","DOI":"10.1080\/21646821.2016.1246336","article-title":"ASET Position Statement on skin safety during EEG procedures\u2014a guideline to improving outcome","volume":"56","year":"2016","journal-title":"Neurodiagn J"}],"container-title":["Advances in Neonatal Care"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00149525-201908000-00005","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,12]],"date-time":"2023-08-12T06:09:03Z","timestamp":1691820543000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00149525-201908000-00005"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,8]]},"references-count":23,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.1097\/anc.0000000000000641","relation":{},"ISSN":["1536-0903"],"issn-type":[{"value":"1536-0903","type":"print"}],"subject":[],"published":{"date-parts":[[2019,8]]}}}