{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,27]],"date-time":"2026-10-27T07:35:21Z","timestamp":1793086521868,"version":"4.5.0"},"reference-count":8,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2017,9]]},"abstract":"<jats:sec>\n                    <jats:title>BACKGROUND:<\/jats:title>\n                    <jats:p>Severe separation of the pubic symphysis is a rare delivery complication. Facing this pathology, we decided to study a new elastic band device.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHOD:<\/jats:title>\n                    <jats:p>To evaluate the elastic band device, clinical (pain-rated) and imaging (magnetic resonance imaging and radiography) evaluations with and without the device were performed. The elastic band device is a European Conformity-certified medical device, which is made of neoprene straps, that reduces the mobility of the pelvis and the use of the internal rotator muscles.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>EXPERIENCE:<\/jats:title>\n                    <jats:p>Once the elastic band device was in place, on postpartum day 1, radiography showed a decrease of the pubic width from 41 to 12 mm. Furthermore, pain decreased from 10 of 10 to 2 of 10 in 2 days, allowing the patient to ambulate and avoid surgery. After 1 month, the pubic width (6 mm) and anatomy were recovered but minor pain was still present with hip rotatory movements. The elastic band device was worn 24 hours a day from postpartum days 1\u201390 and 12 hours a day from postpartum days 90 to 150; afterward, the patient returned to normal life without the elastic band device.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSION:<\/jats:title>\n                    <jats:p>Use of an elastic band device was associated with a reduction of the pubic width and pain associated after obstetric pubic symphysis separation.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/aog.0000000000002194","type":"journal-article","created":{"date-parts":[[2017,8,8]],"date-time":"2017-08-08T15:27:30Z","timestamp":1502206050000},"page":"625-629","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":5,"title":["Using an Elastic Band Device After a Severe Obstetric Pubic Symphyseal Separation"],"prefix":"10.1097","volume":"130","author":[{"given":"Jeremy","family":"Lasbleiz","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fran\u00e7ois-Xavier","family":"Sevestre","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pierre-Yves","family":"Moquet","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20261027","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1111\/j.1469-7580.2010.01300.x","article-title":"The adult human pubic symphysis: a systematic review","volume":"217","author":"Becker","year":"2010","journal-title":"J Anat"},{"key":"R2-20261027","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1576\/toag.8.3.153.27250","article-title":"Symphysis pubis dysfunction: a practical approach to management","volume":"8","author":"Jain","year":"2006","journal-title":"Obstet Gynaecol"},{"key":"R3-20261027","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1016\/S0301-2115(02)00192-6","article-title":"Symphysis pubis dysfunction a cause of significant obstetric morbidity","volume":"105","author":"Owens","year":"2002","journal-title":"Eur J Obstet Gynecol Reprod Biol"},{"key":"R5-20261027","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1097\/OGX.0b013e31821f84d9","article-title":"Peripartum pubic symphysis separation: a case report and review of the literature","volume":"66","author":"Nitsche","year":"2011","journal-title":"Obstet Gynecol Surv"},{"key":"R6-20261027","doi-asserted-by":"crossref","first-page":"1074","DOI":"10.1016\/j.injury.2015.02.030","article-title":"Peripartum pubic symphysis separation\u2014current strategies in diagnosis and therapy and presentation of two cases","volume":"46","author":"Herren","year":"2015","journal-title":"Injury"},{"key":"R7-20261027","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1097\/AOG.0b013e3181998bd1","article-title":"Severe separation of the pubic symphysis and prompt orthopedic surgical intervention","volume":"114","author":"Dunivan Gena","year":"2009","journal-title":"Obstet Gynecol"},{"key":"R8-20261027","first-page":"1114","article-title":"Rupture of the symphysis pubis during vaginal delivery followed by two subsequent uneventful pregnancies","volume":"100","author":"Culligan","year":"2002","journal-title":"Obstet Gynecol"},{"key":"R9-20261027","doi-asserted-by":"crossref","first-page":"e367","DOI":"10.3928\/01477447-20160307-02","article-title":"Management of postpartum diastasis of the pubic symphysis","volume":"39","author":"Erickson","year":"2016","journal-title":"Orthopedics"}],"container-title":["Obstetrics &amp; Gynecology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/00006250-201709000-00018","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,27]],"date-time":"2026-10-27T07:00:14Z","timestamp":1793084414000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/00006250-201709000-00018"}},"subtitle":["Clinical and Imaging Evaluation"],"short-title":[],"issued":{"date-parts":[[2017,9]]},"references-count":8,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2017]]}},"URL":"https:\/\/doi.org\/10.1097\/aog.0000000000002194","relation":{},"ISSN":["0029-7844","1873-233X"],"issn-type":[{"value":"0029-7844","type":"print"},{"value":"1873-233X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,9]]}}}