{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,18]],"date-time":"2026-11-18T18:26:59Z","timestamp":1795026419707,"version":"4.10.2"},"reference-count":2,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2019,2]]},"abstract":"<jats:sec>\n                    <jats:title>BACKGROUND:<\/jats:title>\n                    <jats:p>Minimally invasive fingerstick sampling allows testing of reproductive hormone levels at home, providing women with increased access to tests that can screen for conditions such as polycystic ovarian syndrome, primary ovarian insufficiency, and pituitary and thyroid dysfunction.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHOD:<\/jats:title>\n                    <jats:p>\n                      We present a measurement procedure comparison study of matched venipuncture and fingerstick samples from 130 women aged 18\u201340 years, tested on menstrual cycle day 3. Samples were measured for anti-m\u00fcllerian hormone, estradiol (E2), follicle-stimulating hormone (FSH), luteinizing hormone (LH), prolactin (PRL), testosterone, thyroid-stimulating hormone (TSH), and free thyroxine (T\n                      <jats:sub>4<\/jats:sub>\n                      ) levels. Samples were tested using U.S. Food and Drug Administration\u2013cleared immunoassays, with a modified reconstitution step for fingerstick samples.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>EXPERIENCE:<\/jats:title>\n                    <jats:p>Venipuncture and fingerstick hormone values were concordant and linear across all assay ranges. There was no evidence of systematic bias across the assay ranges, and bias measures were below recommended guidelines. The correlation between venipuncture and fingerstick was between 0.99 and 1.0 for each hormone. Each assay displayed a high degree of precision (less than 13% coefficient of variation) and a high level of accuracy (average recovery equaled 95.5\u2013102.3%).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSION:<\/jats:title>\n                    <jats:p>\n                      Venipuncture and fingerstick samples can be used interchangeably to measure anti-m\u00fcllerian hormone, E2, FSH, LH, PRL, testosterone, TSH, and free T\n                      <jats:sub>4<\/jats:sub>\n                      levels. Fingerstick sampling provides doctors and women more convenient testing options.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>FUNDING SOURCE:<\/jats:title>\n                    <jats:p>The study was sponsored by Modern Fertility.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/aog.0000000000003066","type":"journal-article","created":{"date-parts":[[2019,1,24]],"date-time":"2019-01-24T10:36:52Z","timestamp":1548326212000},"page":"343-348","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":16,"title":["Concordance of Fingerstick and Venipuncture Sampling for Fertility Hormones"],"prefix":"10.1097","volume":"133","author":[{"given":"Erin E.","family":"Burke","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Safedin","family":"Beqaj","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nataki C.","family":"Douglas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert","family":"Luo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20261118","doi-asserted-by":"crossref","first-page":"2503","DOI":"10.1093\/humrep\/des194","article-title":"Quantification of anti-M\u00fcllerian hormone (AMH) in dried blood spots: validation of a minimally invasive method for assessing ovarian reserve","volume":"27","author":"McDade","year":"2012","journal-title":"Hum Reprod"},{"key":"R2-20261118","doi-asserted-by":"crossref","first-page":"899","DOI":"10.1353\/dem.2007.0038","article-title":"What a drop can do: dried blood spots as a minimally invasive method for integrating biomarkers into population-based research","volume":"44","author":"McDade","year":"2007","journal-title":"Demography"}],"container-title":["Obstetrics &amp; Gynecology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/00006250-201902000-00015","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,11,18]],"date-time":"2026-11-18T18:02:07Z","timestamp":1795024927000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/00006250-201902000-00015"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,2]]},"references-count":2,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.1097\/aog.0000000000003066","relation":{},"ISSN":["0029-7844","1873-233X"],"issn-type":[{"value":"0029-7844","type":"print"},{"value":"1873-233X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,2]]},"assertion":[{"value":"2018-08-31","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2018-11-08","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}