{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T11:23:22Z","timestamp":1787743402092,"version":"build-2784847793"},"reference-count":32,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","funder":[{"name":"National Institute of Child Health and Human Development","award":["K23HD103875"],"award-info":[{"award-number":["K23HD103875"]}]}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,11]]},"abstract":"<jats:p>Continuous glucose monitoring (CGM) has the potential to revolutionize diabetes management during pregnancy by providing detailed and real-time data to patients and clinicians, overcoming many of the limitations of self-monitoring of blood glucose. Although there are limited data on the role of CGM to improve pregnancy outcomes in patients with type 2 diabetes or gestational diabetes, CGM has been shown to reduce pregnancy complications in patients with type 1 diabetes. Despite the limited data in some populations, given its ease of use and recent U.S. Food and Drug Administration approval with expanding insurance coverage, CGM has gained widespread popularity among pregnant patients with all types of diabetes. It is critical for obstetric clinicians to understand how CGM can be successfully integrated into clinical practice. We present a practical, step-wise approach to CGM data interpretation that can be incorporated into diabetes management during pregnancy and common CGM pitfalls and solutions. Although technology will continue to advance with newer-generation CGM devices and diabetes technology such as automated insulin delivery (not covered here), these key principles form a basic foundation for understanding CGM technology and its utility for pregnant people.<\/jats:p>","DOI":"10.1097\/aog.0000000000005669","type":"journal-article","created":{"date-parts":[[2024,7,17]],"date-time":"2024-07-17T08:02:23Z","timestamp":1721203343000},"page":"649-659","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":18,"title":["Continuous Glucose Monitoring for Diabetes Management During Pregnancy"],"prefix":"10.1097","volume":"144","author":[{"given":"Ashley N.","family":"Battarbee","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Celeste","family":"Durnwald","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lynn M.","family":"Yee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amy M.","family":"Valent","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2024,7,17]]},"reference":[{"key":"R1-20260826","doi-asserted-by":"crossref","first-page":"e228","DOI":"10.1097\/AOG.0000000000002960","article-title":"Pregestational diabetes mellitus. ACOG Practice Bulletin No. 201. American College of Obstetricians and Gynecologists","volume":"132","year":"2018","journal-title":"Obstet Gynecol"},{"key":"R2-20260826","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1016\/S2213-8587(20)30406-X","article-title":"Characteristics and outcomes of pregnant women with type 1 or type 2 diabetes: a 5-year national population-based cohort study","volume":"9","author":"Murphy","year":"2021","journal-title":"Lancet Diabetes Endocrinol"},{"key":"R3-20260826","doi-asserted-by":"crossref","first-page":"232","DOI":"10.1038\/s41372-019-0516-5","article-title":"The association of pregestational and gestational diabetes with severe neonatal morbidity and mortality","volume":"40","author":"Battarbee","year":"2020","journal-title":"J Perinatol"},{"key":"R4-20260826","doi-asserted-by":"crossref","first-page":"364","DOI":"10.1016\/S0002-9378(00)70225-0","article-title":"Risks of preeclampsia and adverse neonatal outcomes among women with pregestational diabetes mellitus: National Institute of Child Health and Human Development Network of Maternal-Fetal Medicine Units","volume":"182","author":"Sibai","year":"2000","journal-title":"Am J Obstet Gynecol"},{"key":"R5-20260826","doi-asserted-by":"crossref","first-page":"e49","DOI":"10.1097\/AOG.0000000000002501","article-title":"Gestational diabetes mellitus. ACOG Practice Bulletin No. 190. American College of Obstetricians and Gynecologists","volume":"131","year":"2018","journal-title":"Obstet Gynecol"},{"key":"R6-20260826","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1016\/0002-9378(91)90637-7","article-title":"Maternal postprandial glucose levels and infant birth weight: the diabetes in early pregnancy study: the National Institute of Child Health and Human Development\u2013Diabetes in Early pregnancy study","volume":"164","author":"Jovanovic-Peterson","year":"1991","journal-title":"Am J Obstet Gynecol"},{"key":"R7-20260826","first-page":"515","article-title":"Glycemic thresholds for spontaneous abortion and congenital malformations in insulin-dependent diabetes mellitus","volume":"84","author":"Rosenn","year":"1994","journal-title":"Obstet Gynecol"},{"issue":"suppl 1","key":"R8-20260826","first-page":"S282","article-title":"15. Management of diabetes in pregnancy: Standards of Care in Diabetes\u20132024","volume":"47","year":"2024","journal-title":"Diabetes Care"},{"key":"R9-20260826","doi-asserted-by":"crossref","first-page":"1048","DOI":"10.1111\/1753-0407.13454","article-title":"Patient experiences of continuous glucose monitoring and sensor-augmented insulin pump therapy for diabetes: a systematic review of qualitative studies","volume":"15","author":"Natale","year":"2023","journal-title":"J Diabetes"},{"key":"R10-20260826","doi-asserted-by":"crossref","first-page":"e270622206400","DOI":"10.2174\/1573399819666220627111430","article-title":"Barriers and facilitators to diabetes self-management in pregnant women with pre-existing type 2 diabetes mellitus: a scoping review","volume":"19","author":"Phonyiam","year":"2023","journal-title":"Curr Diabetes Rev"},{"key":"R11-20260826","doi-asserted-by":"crossref","first-page":"926","DOI":"10.1353\/hpu.2015.0073","article-title":"\u201cI was tired of all the sticking and poking\u201d: identifying barriers to diabetes self-care among low-income pregnant women","volume":"26","author":"Yee","year":"2015","journal-title":"J Health Care Poor Underserved"},{"key":"R12-20260826","doi-asserted-by":"crossref","first-page":"1242","DOI":"10.1055\/s-0036-1584540","article-title":"Examining the role of health literacy in optimizing the care of pregnant women with diabetes","volume":"33","author":"Yee","year":"2016","journal-title":"Am J Perinatol"},{"key":"R13-20260826","doi-asserted-by":"crossref","first-page":"2347","DOI":"10.1016\/S0140-6736(17)32400-5","article-title":"Continuous glucose monitoring in pregnant women with type 1 diabetes (CONCEPTT): a multicentre international randomised controlled trial","volume":"390","author":"Feig","year":"2017","journal-title":"Lancet"},{"key":"R14-20260826","doi-asserted-by":"crossref","first-page":"1652","DOI":"10.1111\/dme.14046","article-title":"Modelling potential cost savings from use of real\u2010time continuous glucose monitoring in pregnant women with type 1 diabetes","volume":"36","author":"Murphy","year":"2019","journal-title":"Diabetic Med"},{"key":"R15-20260826","doi-asserted-by":"crossref","first-page":"100969","DOI":"10.1016\/j.ajogmf.2023.100969","article-title":"Continuous glucose monitor use in type 2 diabetes mellitus in pregnancy and perinatal outcomes: a systematic review and meta-analysis","volume":"5","author":"Wilkie","year":"2023","journal-title":"Am J Obstet Gynecol MFM"},{"key":"R16-20260826","doi-asserted-by":"crossref","first-page":"697","DOI":"10.3389\/fendo.2019.00697","article-title":"Application and utility of continuous glucose monitoring in pregnancy: a systematic review","volume":"10","author":"Yu","year":"2019","journal-title":"Front Endocrinol (Lausanne)"},{"issue":"suppl 1","key":"R17-20260826","first-page":"S126","article-title":"7. Diabetes technology: standards of care in diabetes\u20132024","volume":"47","year":"2024","journal-title":"Diabetes Care"},{"key":"R18-20260826","doi-asserted-by":"crossref","first-page":"S72","DOI":"10.1089\/dia.2021.0233","article-title":"Integrating continuous glucose monitoring into clinical practices and patients' lives","volume":"23","author":"Hirsch","year":"2021","journal-title":"Diabetes Technol Ther"},{"key":"R19-20260826","doi-asserted-by":"crossref","first-page":"1182","DOI":"10.1177\/1932296819867683","article-title":"Understanding patient and provider perspective on impact of professional continuous glucose monitors on diabetes control in a complex care population","volume":"13","author":"Raju","year":"2019","journal-title":"J Diabetes Sci Technol"},{"key":"R20-20260826","doi-asserted-by":"crossref","first-page":"664","DOI":"10.1177\/1932296818813581","article-title":"Continuous glucose monitoring integration in clinical practice: a stepped guide to data review and interpretation","volume":"13","author":"Aleppo","year":"2019","journal-title":"J Diabetes Sci Technol"},{"key":"R21-20260826","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1089\/dia.2023.0516","article-title":"Performance of the Dexcom G7 continuous glucose monitoring system in pregnant women with diabetes","volume":"26","author":"Polsky","year":"2024","journal-title":"Diabetes Technol Ther"},{"key":"R22-20260826","doi-asserted-by":"crossref","first-page":"767","DOI":"10.1007\/s13300-023-01385-6","article-title":"Accuracy of the third generation of a 14-day continuous glucose monitoring system","volume":"14","author":"Alva","year":"2023","journal-title":"Diabetes Ther"},{"key":"R23-20260826","doi-asserted-by":"crossref","first-page":"943","DOI":"10.1089\/dia.2020.0085","article-title":"Performance of the Dexcom G6 continuous glucose monitoring system in pregnant women with diabetes","volume":"22","author":"Castorino","year":"2020","journal-title":"Diabetes Technol Ther"},{"key":"R24-20260826","doi-asserted-by":"crossref","first-page":"743","DOI":"10.1080\/00325481.2022.2110507","article-title":"Stepwise approach to continuous glucose monitoring interpretation for internists and family physicians","volume":"134","author":"Szmuilowicz","year":"2022","journal-title":"Postgrad Med"},{"key":"R25-20260826","doi-asserted-by":"crossref","first-page":"1593","DOI":"10.2337\/dci19-0028","article-title":"Clinical targets for continuous glucose monitoring data interpretation: recommendations from the international consensus on time in range","volume":"42","author":"Battelino","year":"2019","journal-title":"Diabetes Care"},{"key":"R26-20260826","doi-asserted-by":"crossref","DOI":"10.1016\/j.ajog.2024.01.010","article-title":"Continuous glucose monitoring in pregnancies with type 1 diabetes: small increases in time-in-range improve maternal and perinatal outcomes","author":"Sobhani","year":"2024","journal-title":"Am J Obstet Gynecol"},{"key":"R27-20260826","doi-asserted-by":"crossref","first-page":"89","DOI":"10.2337\/dc23-0636","article-title":"Association of continuous glucose monitoring metrics with pregnancy outcomes in patients with preexisting diabetes","volume":"47","author":"Sanusi","year":"2024","journal-title":"Diabetes Care"},{"key":"R28-20260826","doi-asserted-by":"crossref","first-page":"1894","DOI":"10.1111\/dom.13310","article-title":"Continuous glucose monitoring during diabetic pregnancy (GlucoMOMS): a multicentre randomized controlled trial","volume":"20","author":"Voormolen","year":"2018","journal-title":"Diabetes Obes Metab"},{"key":"R29-20260826","doi-asserted-by":"crossref","first-page":"1123","DOI":"10.1007\/s00125-019-4904-3","article-title":"Continuous glucose monitoring targets in type 1 diabetes pregnancy: every 5% time in range matters","volume":"62","author":"Murphy","year":"2019","journal-title":"Diabetologia"},{"key":"R30-20260826","doi-asserted-by":"crossref","first-page":"785","DOI":"10.1016\/S2213-8587(23)00259-0","article-title":"Faster and faster: meeting the challenges of delayed insulin action during pregnancy","volume":"11","author":"Feig","year":"2023","journal-title":"Lancet Diabetes Endocrinol"},{"key":"R31-20260826","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1089\/dia.2022.0540","article-title":"Expert guidance on off-label use of hybrid closed-loop therapy in pregnancies complicated by diabetes","volume":"25","author":"Szmuilowicz","year":"2023","journal-title":"Diabetes Technol Ther"},{"key":"R32-20260826","doi-asserted-by":"crossref","first-page":"1566","DOI":"10.1056\/NEJMoa2303911","article-title":"Automated insulin delivery in women with pregnancy complicated by type 1 diabetes","volume":"389","author":"Lee","year":"2023","journal-title":"N Engl J Med"}],"container-title":["Obstetrics &amp; Gynecology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/AOG.0000000000005669","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T11:00:36Z","timestamp":1787742036000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/AOG.0000000000005669"}},"subtitle":["Evidence, Practical Tips, and Common Pitfalls"],"short-title":[],"issued":{"date-parts":[[2024,7,17]]},"references-count":32,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1097\/aog.0000000000005669","relation":{},"ISSN":["0029-7844","1873-233X"],"issn-type":[{"value":"0029-7844","type":"print"},{"value":"1873-233X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,7,17]]},"assertion":[{"value":"2024-03-15","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-05-23","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}