{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,7]],"date-time":"2026-09-07T13:29:46Z","timestamp":1788787786332,"version":"build-2803163510"},"reference-count":16,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,1]]},"abstract":"<jats:sec>\n                    <jats:title>OBJECTIVE:<\/jats:title>\n                    <jats:p>To compare intrauterine balloon tamponade and vacuum-induced hemorrhage-control devices in a multicenter hospital system using a standardized three-stage postpartum hemorrhage response algorithm.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>As part of a quality improvement project, data were prospectively collected through ongoing detailed hemorrhage case audits from 65 facilities from August 2022 to February 2024. Postpartum hemorrhage-control devices are recommended for stage 2 or 3 of the postpartum hemorrhage algorithm. The primary outcomes were 1) quantitative blood loss after device placement, 2) rate of packed red blood cell (RBC) transfusion, 3) use of 3 units of packed RBCs or more, and 4) device failure.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>\n                      During the 17-month observation period, there were 123,292 deliveries, and postpartum hemorrhage occurred in 5,931 (4.8%). Postpartum hemorrhage-control devices were used in 11.2% of cases (666 total, intrauterine balloon tamponade n=300, and vacuum-induced hemorrhage control n=366). For intrauterine balloon tamponade and vacuum-induced hemorrhage-control devices, quantitative blood loss (median and interquartile range) after device placement was similar at 194 (67\u2013440) mL and 240 (113\u2013528) mL (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =.40), respectively, as was the rate of any packed RBC transfusion (59.7% vs 50.0%,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =.08), transfusion of 3 packed RBC units or more (27.0% vs 24.9%,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =.53), and device failure (7.7% vs 8.5%,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      =.70). Placement of either device at a quantitative blood loss between 1,000 and 1,499 mL compared with 1,500 mL or more resulted in significantly lower rates of packed RBC transfusion (39.1% vs 70.3%,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt;.001), transfusion of 3 or more packed RBC units (13.7 vs 38.1%,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt;.001), and device failure (3.4% vs 12.9%,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt;.001).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSION:<\/jats:title>\n                    <jats:p>Transfusion and blood loss after device placement were similar with both hemorrhage-control devices. Earlier hemorrhage-control device placement reduced device failure and the need for transfusion.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/aog.0000000000005770","type":"journal-article","created":{"date-parts":[[2024,10,24]],"date-time":"2024-10-24T17:00:26Z","timestamp":1729789226000},"page":"65-71","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":13,"title":["Effectiveness of the Intrauterine Balloon Tamponade Compared With an Intrauterine, Vacuum-Induced, Hemorrhage-Control Device for Postpartum Hemorrhage"],"prefix":"10.1097","volume":"145","author":[{"given":"Laurence E.","family":"Shields","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Catherine","family":"Klein","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jennie","family":"Torti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mindy","family":"Foster","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Curtis","family":"Cook","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2024,10,24]]},"reference":[{"key":"R1-20260825","doi-asserted-by":"crossref","first-page":"e168","DOI":"10.1097\/AOG.0000000000002351","article-title":"Postpartum hemorrhage. Practice Bulletin No. 183. American College of Obstetricians and Gynecologists","volume":"130","year":"2017","journal-title":"Obstet Gynecol"},{"key":"R2-20260825","doi-asserted-by":"crossref","first-page":"353.e1","DOI":"10.1016\/j.ajog.2010.01.011","article-title":"Trends in postpartum hemorrhage: United States, 1994-2006","volume":"202","author":"Callaghan","year":"2010","journal-title":"Am J Obstet Gynecol"},{"key":"R3-20260825","doi-asserted-by":"crossref","first-page":"1066","DOI":"10.1016\/S0140-6736(06)68397-9","article-title":"WHO analysis of causes of maternal death: a systematic review","volume":"367","author":"Khan","year":"2006","journal-title":"Lancet"},{"key":"R4-20260825","doi-asserted-by":"crossref","first-page":"1000","DOI":"10.1097\/AOG.0000000000005403","article-title":"Intrauterine postpartum hemorrhage-control devices","volume":"142","author":"Jackson","year":"2023","journal-title":"Obstet Gynecol"},{"key":"R6-20260825","doi-asserted-by":"crossref","first-page":"753","DOI":"10.1055\/s-0031-1280856","article-title":"Assessing preventability for obstetric hemorrhage","volume":"28","author":"Della Torre","year":"2011","journal-title":"Am J Perinatol"},{"key":"R7-20260825","first-page":"155","article-title":"National Partnership for Maternal Safety: consensus bundle on obstetric hemorrhage","volume":"126","author":"Main","year":"2015","journal-title":"Obstet Gynecol"},{"key":"R8-20260825","doi-asserted-by":"crossref","first-page":"290","DOI":"10.1002\/ijgo.13028","article-title":"Postpartum hemorrhage care bundles to improve adherence to guidelines: a WHO technical consultation","volume":"148","author":"Althabe","year":"2020","journal-title":"Int J Gynaecol Obstet"},{"key":"R9-20260825","doi-asserted-by":"crossref","first-page":"882","DOI":"10.1097\/AOG.0000000000004138","article-title":"Intrauterine vacuum-induced hemorrhage-control device for rapid treatment of postpartum hemorrhage","volume":"136","author":"D'Alton","year":"2020","journal-title":"Obstet Gynecol"},{"key":"R10-20260825","doi-asserted-by":"crossref","first-page":"1006","DOI":"10.1097\/AOG.0000000000005366","article-title":"Real-world utilization of an intrauterine, vacuum-induced, hemorrhage-control device","volume":"142","author":"Goffman","year":"2023","journal-title":"Obstet Gynecol"},{"key":"R11-20260825","doi-asserted-by":"crossref","first-page":"293.e1","DOI":"10.1016\/j.ajog.2019.11.1287","article-title":"Uterine balloon tamponade for the treatment of postpartum hemorrhage: a systematic review and meta-analysis","volume":"222","author":"Suarez","year":"2020","journal-title":"Am J Obstet Gynecol"},{"key":"R12-20260825","doi-asserted-by":"crossref","first-page":"267","DOI":"10.1016\/j.jogc.2023.02.017","article-title":"Vacuum-induced hemorrhage control versus uterine balloon tamponade for postpartum hemorrhage","volume":"45","author":"Gulersen","year":"2023","journal-title":"J Obstet Gynaecol Can"},{"key":"R13-20260825","doi-asserted-by":"crossref","first-page":"65","DOI":"10.7812\/TPP\/15-141","article-title":"SQUIRE 2.0 (standards for QUality improvement reporting excellence): revised publication guidelines from a detailed consensus process","volume":"19","author":"Ogrinc","year":"2015","journal-title":"Perm J"},{"key":"R14-20260825","doi-asserted-by":"crossref","first-page":"368.e1","DOI":"10.1016\/j.ajog.2011.06.084","article-title":"Comprehensive maternal hemorrhage protocols improve patient safety and reduce utilization of blood products","volume":"205","author":"Shields","year":"2011","journal-title":"Am J Obstet Gynecol"},{"key":"R15-20260825","doi-asserted-by":"crossref","first-page":"272","DOI":"10.1016\/j.ajog.2014.07.012","article-title":"Comprehensive maternal hemorrhage protocols reduce the use of blood products and improve patient safety","volume":"212","author":"Shields","year":"2015","journal-title":"Am J Obstet Gynecol"},{"key":"R16-20260825","doi-asserted-by":"crossref","first-page":"252","DOI":"10.1097\/AOG.0000000000005628","article-title":"Pregnancy-related deaths due to hemorrhage: Pregnancy Mortality Surveillance System, 2012\u20132019","volume":"144","author":"Hollier","year":"2024","journal-title":"Obstet Gynecol"},{"key":"R17-20260825","doi-asserted-by":"crossref","first-page":"992","DOI":"10.1016\/j.jval.2017.02.009","article-title":"How to compare the length of stay of two samples of inpatients? A simulation study to compare type I and type II errors of 12 statistical tests","volume":"20","author":"Chazard","year":"2017","journal-title":"Value Health"}],"container-title":["Obstetrics &amp; Gynecology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/AOG.0000000000005770","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T10:00:51Z","timestamp":1787652051000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/AOG.0000000000005770"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,10,24]]},"references-count":16,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/aog.0000000000005770","relation":{},"ISSN":["0029-7844","1873-233X"],"issn-type":[{"value":"0029-7844","type":"print"},{"value":"1873-233X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,10,24]]},"assertion":[{"value":"2024-06-04","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-08-08","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}