{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T20:09:21Z","timestamp":1792786161673,"version":"4.5.0"},"reference-count":25,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","funder":[{"DOI":"10.13039\/100000124","name":"Office of Research on Women's Health","doi-asserted-by":"crossref","award":["NIH K12AR08421"],"award-info":[{"award-number":["NIH K12AR08421"]}],"id":[{"id":"10.13039\/100000124","id-type":"DOI","asserted-by":"crossref"}]},{"name":"National Science Foundation","award":["1934824"],"award-info":[{"award-number":["1934824"]}]},{"name":"Coordena\u00c3\u00a7\u00c3\u00a3o de Aperfei\u00c3\u00a7oamento de Pessoal de N\u00c3\u2010vel Superior","award":["ME\/CAPES N\u00c2\u00ba 8\/2020"],"award-info":[{"award-number":["ME\/CAPES N\u00c2\u00ba 8\/2020"]}]}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,7]]},"abstract":"<jats:sec>\n                    <jats:title>OBJECTIVE:<\/jats:title>\n                    <jats:p>To evaluate the environmental effects and cost of four different uterine manipulators using life cycle assessment and life cycle costing.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>\n                      Life cycle assessment, which evaluates the environmental effects of a product or process throughout its life cycle, including production, use, and disposal, was performed on a reusable stainless-steel manipulator, two disposable manipulators, and a hybrid manipulator with both reusable and disposable pieces. Uncertainty in data was addressed through Monte Carlo analysis. Life cycle costing was conducted concurrently, incorporating procurement, sterilization, and waste removal costs and excluding capital equipment costs. Costs were estimated from institutional contracts, labor, materials, and energy use. The primary outcome of this study was the environmental footprint of four uterine manipulators. Secondarily, we compared the global warming potential (kilograms of CO\n                      <jats:sub>2<\/jats:sub>\n                      -equivalents) and costs (U.S. dollars) associated with the production, use, sterilization, and disposal of these manipulators over 300 hysterectomies, the approximate life of the reusable manipulator.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>The reusable stainless-steel manipulator had the lowest carbon footprint and environmental effect in every category. The disposable manipulators had global warming emissions 4.24 and 2.39 times higher than the reusable manipulator, and the hybrid had emissions 3.76 times higher at 15 uses. Sterilization contributed most of the effects for the reusable manipulator, and production contributed the most for the other devices. The reusable manipulator had the highest up-front costs, but over 300 uses saved the institution $16,000\u201343,000 compared with the other devices.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSION:<\/jats:title>\n                    <jats:p>The reusable stainless-steel uterine manipulator had the lowest carbon footprint and cost compared with the disposable and hybrid devices over their life cycles. Health care leadership should invest in reusable devices; clinicians should prioritize reusable options; and industry partners should innovate and manufacture stainless-steel instruments to help decarbonize the health care system.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/aog.0000000000005949","type":"journal-article","created":{"date-parts":[[2025,5,22]],"date-time":"2025-05-22T17:00:31Z","timestamp":1747933231000},"page":"104-112","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["A Comparative Carbon Footprint and Cost Analysis of Uterine Manipulators for Hysterectomy"],"prefix":"10.1097","volume":"146","author":[{"given":"Alexandra I.","family":"Melnyk","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nathalia","family":"Silva de Souza Lima Cano","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephanie","family":"Glass Clark","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Melissa M.","family":"Bilec","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amanda","family":"Artsen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,5,22]]},"reference":[{"key":"R1-20260826","first-page":"663","article-title":"Sustainability initiatives in the operating room","volume":"47","author":"Wu","year":"2021","journal-title":"Jt Comm J Qual Patient Saf"},{"key":"R2-20260826","doi-asserted-by":"crossref","first-page":"1970","DOI":"10.1001\/jama.2009.1610","article-title":"Estimate of the carbon footprint of the US health care sector","volume":"302","author":"Chung","year":"2009","journal-title":"JAMA"},{"key":"R4-20260826","doi-asserted-by":"crossref","first-page":"1779","DOI":"10.1021\/es504719g","article-title":"Environmental impacts of surgical procedures: life cycle assessment of hysterectomy in the United States","volume":"49","author":"Thiel","year":"2015","journal-title":"Environ Sci Technol"},{"key":"R5-20260826","doi-asserted-by":"crossref","first-page":"e094","DOI":"10.1097\/AS9.0000000000000094","article-title":"A standardized method for estimating the carbon footprint of disposable minimally invasive surgical devices: application in transurethral prostate surgery","volume":"2","author":"Misrai","year":"2021","journal-title":"Ann Surg Open"},{"key":"R7-20260826","doi-asserted-by":"crossref","first-page":"1108","DOI":"10.1097\/SLA.0000000000004755","article-title":"Empowering surgeons, anesthesiologists, and obstetricians to incorporate environmental sustainability in the operating room","volume":"273","author":"Yates","year":"2021","journal-title":"Ann Surg"},{"key":"R8-20260826","doi-asserted-by":"crossref","first-page":"979","DOI":"10.1001\/jamasurg.2022.2346","article-title":"The surgical suite\u2014a field laboratory for sustainability","volume":"157","author":"Belliveau","year":"2022","journal-title":"JAMA Surg"},{"key":"R9-20260826","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1016\/j.ajog.2023.04.025","article-title":"Going green in gynecology: a call to action","volume":"229","author":"Melnyk","year":"2023","journal-title":"Am J Obstet Gynecol"},{"key":"R10-20260826","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1097\/01.ogx.0001010444.52038.f1","article-title":"Sustainability in obstetrics and gynecology","volume":"79","author":"Wright","year":"2024","journal-title":"Obstet Gynecol Surv"},{"key":"R11-20260826","doi-asserted-by":"crossref","first-page":"225.e1","DOI":"10.1016\/j.ajog.2020.02.007","article-title":"A comparative carbon footprint analysis of disposable and reusable vaginal specula","volume":"223","author":"Donahue","year":"2020","journal-title":"Am J Obstet Gynecol"},{"key":"R12-20260826","doi-asserted-by":"crossref","first-page":"680","DOI":"10.1016\/j.bja.2020.06.055","article-title":"Environmental sustainability in anaesthesia and critical care","volume":"125","author":"McGain","year":"2020","journal-title":"Br J Anaesth"},{"key":"R13-20260826","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1016\/j.scitotenv.2012.03.006","article-title":"Life cycle assessment perspectives on delivering an infant in the US","volume":"425","author":"Campion","year":"2012","journal-title":"Sci Total Environ"},{"key":"R14-20260826","doi-asserted-by":"crossref","first-page":"025002","DOI":"10.1088\/2515-7620\/ac4a3d","article-title":"Life cycle assessment of stainless-steel reusable speculums versus disposable acrylic speculums in a university clinic setting: a case study","volume":"4","author":"Rodriguez Morris","year":"2022","journal-title":"Environ Res Commun"},{"key":"R15-20260826","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1016\/j.surge.2024.05.003","article-title":"Does reusable mean green? Comparison of the environmental impact of reusable operating room bed covers and lift sheets versus single-use","volume":"22","author":"Chang","year":"2024","journal-title":"Surgeon"},{"key":"R16-20260826","doi-asserted-by":"crossref","first-page":"434","DOI":"10.1213\/ANE.0000000000002683","article-title":"Life cycle assessment and costing methods for device procurement: comparing reusable and single-use disposable laryngoscopes","volume":"127","author":"Sherman","year":"2018","journal-title":"Anesth Analg"},{"key":"R17-20260826","doi-asserted-by":"crossref","first-page":"268","DOI":"10.1007\/s00464-003-9232-4","article-title":"Comparison of economic and environmental impacts between disposable and reusable instruments used for laparoscopic cholecystectomy","volume":"19","author":"Adler","year":"2005","journal-title":"Surg Endosc"},{"key":"R20-20260826","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1097\/SPV.0000000000000214","article-title":"Analysis of high-intermediate-and low-volume surgeons when performing hysterectomy for uterovaginal prolapse","volume":"22","author":"Morgan","year":"2016","journal-title":"Female Pelvic Med Reconstr Surg"},{"key":"R21-20260826","doi-asserted-by":"crossref","first-page":"139.e1","DOI":"10.1016\/j.ajog.2016.10.027","article-title":"Every woman deserves a high-volume gynecologic surgeon","volume":"216","author":"Walter","year":"2017","journal-title":"Am J Obstet Gynecol"},{"key":"R22-20260826","doi-asserted-by":"crossref","first-page":"1341","DOI":"10.1097\/AOG.0b013e3181fca8c5","article-title":"The effect of surgeon volume on outcomes and resource use for vaginal hysterectomy","volume":"116","author":"Rogo-Gupta","year":"2010","journal-title":"Obstet Gynecol"},{"key":"R24-20260826","doi-asserted-by":"crossref","first-page":"687","DOI":"10.1007\/s10098-010-0338-9","article-title":"Traci 2.0: the tool for the reduction and assessment of chemical and other environmental impacts 2.0","volume":"13","author":"Bare","year":"2011","journal-title":"Clean Tech Environ Pol"},{"key":"R25-20260826","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1126\/science.184.4133.134","article-title":"Food-related energy requirements","volume":"184","author":"Hirst","year":"1974","journal-title":"Science"},{"key":"R26-20260826","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1065\/lca2004.06.161","article-title":"Numerical approaches to life cycle interpretation\u2014the case of the ecoinvent\u201996 database (10 pp)","volume":"10","author":"Heijungs","year":"2005","journal-title":"Int J Life Cycle Assess"},{"key":"R27-20260826","doi-asserted-by":"crossref","first-page":"1073","DOI":"10.1213\/ANE.0b013e31824e9b69","article-title":"A life cycle assessment of reusable and single-use central venous catheter insertion kits","volume":"114","author":"McGain","year":"2012","journal-title":"Anesth Analg"},{"key":"R28-20260826","doi-asserted-by":"crossref","first-page":"710","DOI":"10.1016\/j.ygyno.2020.05.030","article-title":"Historical and projected hysterectomy rates in the USA: implications for future observed cervical cancer rates and evaluating prevention interventions","volume":"158","author":"Simms","year":"2020","journal-title":"Gynecol Oncol"},{"key":"R29-20260826","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1097\/SPV.0000000000001393","article-title":"The use of disposable supplies: measuring suburethral sling surgical waste by cost and weight","volume":"30","author":"Melnyk","year":"2024","journal-title":"Urogynecology"},{"key":"R30-20260826","doi-asserted-by":"crossref","first-page":"620","DOI":"10.3171\/2016.2.JNS152442","article-title":"Operating room waste: disposable supply utilization in neurosurgical procedures","volume":"126","author":"Zygourakis","year":"2017","journal-title":"J Neurosurg"}],"container-title":["Obstetrics &amp; Gynecology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/AOG.0000000000005949","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T11:00:22Z","timestamp":1787742022000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/AOG.0000000000005949"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,22]]},"references-count":25,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/aog.0000000000005949","relation":{},"ISSN":["0029-7844","1873-233X"],"issn-type":[{"value":"0029-7844","type":"print"},{"value":"1873-233X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,22]]},"assertion":[{"value":"2025-01-14","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-03-27","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}