{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,21]],"date-time":"2026-10-21T04:00:12Z","timestamp":1792555212295,"version":"4.5.0"},"reference-count":45,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2016,5]]},"abstract":"<jats:sec>\n            <jats:title>Objectives:<\/jats:title>\n            <jats:p>The purpose of this study was to improve bimodal benefit in listeners using a cochlear implant (CI) and a hearing aid (HA) in contralateral ears, by matching the time constants and the number of compression channels of the automatic gain control (AGC) of the HA to the CI. Equivalent AGC was hypothesized to support a balanced loudness for dynamically changing signals like speech and improve bimodal benefit for speech understanding in quiet and with noise presented from the side(s) at 90 degree.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Design:<\/jats:title>\n            <jats:p>Fifteen subjects participated in the study, all using the same Advanced Bionics Harmony CI processor and HA (Phonak Naida S IX UP). In a 3-visit crossover design with 4 weeks between sessions, performance was measured using a HA with a standard AGC (syllabic multichannel compression with 1 ms attack time and 50 ms release time) or an AGC that was adjusted to match that of the CI processor (dual AGC broadband compression, 3 and 240 msec attack time, 80 and 1500 msec release time). In all devices, the AGC was activated above the threshold of 63 dB SPL. The authors balanced loudness across the devices for soft and loud input sounds in 3 frequency bands (0 to 548, 548 to 1000, and &gt;1000 Hz). Speech understanding was tested in free field in quiet and in noise for three spatial speaker configurations, with target speech always presented from the front. Single-talker noise was either presented from the CI side or the HA side, or uncorrelated stationary speech-weighted noise or single-talker noise was presented from both sides. Questionnaires were administered to assess differences in perception between the two bimodal fittings.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Significant bimodal benefit over the CI alone was only found for the AGC-matched HA for the speech tests with single-talker noise. Compared with the standard HA, matched AGC characteristics significantly improved speech understanding in single-talker noise by 1.9 dB when noise was presented from the HA side. AGC matching increased bimodal benefit insignificantly by 0.6 dB when noise was presented from the CI implanted side, or by 0.8 (single-talker noise) and 1.1 dB (stationary noise) in the more complex configurations with two simultaneous maskers from both sides. In questionnaires, subjects rated the AGC-matched HA higher than the standard HA for understanding of one person in quiet and in noise, and for the quality of sounds. Listening to a slightly raised voice, subjects indicated increased listening comfort with matched AGCs. At the end of the study, 9 of 15 subjects preferred to take home the AGC-matched HA, 1 preferred the standard HA and 5 subjects had no preference.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>For bimodal listening, the AGC-matched HA outperformed the standard HA in speech understanding in noise tasks using a single competing talker and it was favored in questionnaires and in a subjective preference test. When noise was presented from the HA side, AGC matching resulted in a 1.9 dB SNR additional benefit, even though the HA was at the least favorable SNR side in this speaker configuration. Our results possibly suggest better binaural processing for matched AGCs.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/aud.0000000000000260","type":"journal-article","created":{"date-parts":[[2015,12,12]],"date-time":"2015-12-12T14:52:29Z","timestamp":1449931949000},"page":"260-270","source":"Crossref","is-referenced-by-count":47,"title":["Matching Automatic Gain Control Across Devices in Bimodal Cochlear Implant Users"],"prefix":"10.1097","volume":"37","author":[{"given":"Lidwien C. E.","family":"Veugen","sequence":"first","affiliation":[{"name":"Department of Otorhinolaryngology, Donders Institute for Brain, Cognition and Behaviour, Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Josef","family":"Chalupper","sequence":"additional","affiliation":[{"name":"Department of Otorhinolaryngology, Donders Institute for Brain, Cognition and Behaviour, Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ad F. M.","family":"Snik","sequence":"additional","affiliation":[{"name":"Department of Otorhinolaryngology, Donders Institute for Brain, Cognition and Behaviour, Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A. John van","family":"Opstal","sequence":"additional","affiliation":[{"name":"Department of Otorhinolaryngology, Donders Institute for Brain, Cognition and Behaviour, Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lucas H. M.","family":"Mens","sequence":"additional","affiliation":[{"name":"Department of Otorhinolaryngology, Donders Institute for Brain, Cognition and Behaviour, Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"issue":"6 Suppl","key":"R1-20230726","first-page":"S140","article-title":"Speech perception in noise with implant and hearing aid.","volume":"18","author":"Armstrong","year":"1997","journal-title":"Am J Otol"},{"key":"R2-20230726","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1097\/00003446-200002000-00004","article-title":"Monaural and binaural loudness measures in cochlear implant users with contralateral residual hearing.","volume":"21","author":"Blamey","year":"2000","journal-title":"Ear Hear"},{"issue":"9\/10","key":"R3-20230726","first-page":"341","article-title":"Praat, a system for doing phonetics by computer.","volume":"5","author":"Boersma","year":"2001","journal-title":"Glot Int"},{"key":"R5-20230726","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1080\/14992020802581982","article-title":"Comparison of dual-time-constant and fast-acting automatic gain control (AGC) systems in cochlear implants.","volume":"48","author":"Boyle","year":"2009","journal-title":"Int J Audiol"},{"key":"R7-20230726","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1177\/1084713807304357","article-title":"Binaural-bimodal fitting or bilateral implantation for managing severe to profound deafness: a review.","volume":"11","author":"Ching","year":"2007","journal-title":"Trends Amplif"},{"key":"R8-20230726","doi-asserted-by":"crossref","first-page":"212","DOI":"10.1097\/00003446-200106000-00005","article-title":"Maximizing effective audibility in hearing aid fitting.","volume":"22","author":"Ching","year":"2001a","journal-title":"Ear Hear"},{"key":"R9-20230726","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1097\/00003446-200110000-00002","article-title":"Should children who use cochlear implants wear hearing aids in the opposite ear?","volume":"22","author":"Ching","year":"2001b","journal-title":"Ear Hear"},{"key":"R10-20230726","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1097\/AUD.0b013e3181bc7722","article-title":"Bimodal hearing benefit for speech recognition with competing voice in cochlear implant subject with normal hearing in contralateral ear.","volume":"31","author":"Cullington","year":"2010","journal-title":"Ear Hear"},{"key":"R12-20230726","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1159\/000111782","article-title":"The benefits of combining acoustic and electric stimulation for the recognition of speech, voice and melodies.","volume":"13","author":"Dorman","year":"2008","journal-title":"Audiol Neurootol"},{"key":"R13-20230726","first-page":"37","article-title":"Bilateral and bimodal benefit as a function of age for adults.","volume":"2","author":"Dorman","year":"2012","journal-title":"J Hear Sci"},{"key":"R14-20230726","doi-asserted-by":"crossref","first-page":"148","DOI":"10.3109\/00206090109073110","article-title":"ICRA noises: Artificial noise signals with speech-like spectral and temporal properties for hearing instrument assessment. International Collegium for Rehabilitative Audiology.","volume":"40","author":"Dreschler","year":"2001","journal-title":"Audiology"},{"key":"R16-20230726","doi-asserted-by":"crossref","first-page":"749","DOI":"10.1682\/JRRD.2007.08.0120","article-title":"Restoring hearing symmetry with two cochlear implants or one cochlear implant and a contralateral hearing aid.","volume":"45","author":"Firszt","year":"2008","journal-title":"J Rehabil Res Dev"},{"key":"R17-20230726","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1177\/1084713810396511","article-title":"Exploring the factors influencing discontinued hearing aid use in patients with unilateral cochlear implants.","volume":"14","author":"Fitzpatrick","year":"2010","journal-title":"Trends Amplif"},{"key":"R18-20230726","doi-asserted-by":"crossref","first-page":"e45385","DOI":"10.1371\/journal.pone.0045385","article-title":"Speech perception and localisation with SCORE bimodal: A loudness normalisation strategy for combined cochlear implant and hearing aid stimulation.","volume":"7","author":"Francart","year":"2012","journal-title":"PLoS One"},{"key":"R19-20230726","doi-asserted-by":"crossref","first-page":"685","DOI":"10.1097\/AUD.0b013e31829d14cb","article-title":"Psychophysics, fitting, and signal processing for combined hearing aid and cochlear implant stimulation.","volume":"34","author":"Francart","year":"2013","journal-title":"Ear Hear"},{"issue":"Suppl 1","key":"R20-20230726","doi-asserted-by":"crossref","first-page":"S120","DOI":"10.1080\/14992020600783103","article-title":"Two-eared listening in dynamic situations.","volume":"45","author":"Gatehouse","year":"2006","journal-title":"Int J Audiol"},{"key":"R21-20230726","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1080\/14992020400050014","article-title":"The speech, spatial and qualities of hearing scale (SSQ).","volume":"43","author":"Gatehouse","year":"2004","journal-title":"Int J Audiol"},{"key":"R22-20230726","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1097\/01.HJ.0000399149.53245.b1","article-title":"Who is a cochlear implant candidate?","volume":"64","author":"Gifford","year":"2011","journal-title":"Hear J"},{"key":"R23-20230726","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1159\/000355700","article-title":"Availability of binaural cues for bilateral implant recipients and bimodal listeners with and without preserved hearing in the implanted ear.","volume":"19","author":"Gifford","year":"2014","journal-title":"Audiol Neurootol"},{"key":"R24-20230726","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1097\/01.HJ.0000339507.82549.03","article-title":"Epoq study measures user benefit.","volume":"61","author":"Hansen","year":"2008","journal-title":"Hear J"},{"key":"R25-20230726","doi-asserted-by":"crossref","first-page":"1","DOI":"10.4081\/audiores.2013.e1","article-title":"Evaluation of speech intelligibility and sound localization abilities with hearing aids using binaural wireless technology.","volume":"3","author":"Ibrahim","year":"2012","journal-title":"Audiol Res"},{"issue":"3 Pt 1","key":"R26-20230726","doi-asserted-by":"crossref","first-page":"1351","DOI":"10.1121\/1.1857526","article-title":"Speech and melody recognition in binaurally combined acoustic and electric hearing.","volume":"117","author":"Kong","year":"2005","journal-title":"J Acoust Soc Am"},{"key":"R27-20230726","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1177\/1084713810364396","article-title":"Improvements in speech understanding with wireless binaural broadband digital hearing instruments in adults with sensorineural hearing loss.","volume":"14","author":"Kreisman","year":"2010","journal-title":"Trends Amplif"},{"key":"R28-20230726","doi-asserted-by":"crossref","first-page":"2287","DOI":"10.1121\/1.2839013","article-title":"A glimpsing account for the benefit of simulated combined acoustic and electric hearing.","volume":"123","author":"Li","year":"2008","journal-title":"J Acoust Soc Am"},{"key":"R29-20230726","doi-asserted-by":"crossref","first-page":"338","DOI":"10.1044\/1092-4388(2006\/027)","article-title":"Speech perception for adults who use hearing aids in conjunction with cochlear implants in opposite ears.","volume":"49","author":"Mok","year":"2006","journal-title":"J Speech Lang Hear Res"},{"key":"R30-20230726","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1097\/01.HJ.0000299172.13153.6f","article-title":"Binaural sharing of audio signals: Prospective benefits and limitations.","volume":"60","author":"Moore","year":"2007","journal-title":"Hear J"},{"key":"R31-20230726","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1177\/1084713808317819","article-title":"The choice of compression speed in hearing AIDS: Theoretical and practical considerations and the role of individual differences.","volume":"12","author":"Moore","year":"2008","journal-title":"Trends Amplif"},{"key":"R32-20230726","doi-asserted-by":"crossref","first-page":"596","DOI":"10.1080\/00016480510027493","article-title":"Advantages of binaural hearing provided through bimodal stimulation via a cochlear implant and a conventional hearing aid: A 6-month comparative study.","volume":"125","author":"Morera","year":"2005","journal-title":"Acta Otolaryngol"},{"key":"R33-20230726","doi-asserted-by":"crossref","first-page":"505","DOI":"10.1080\/14992020802070770","article-title":"Unilateral and bilateral cochlear implants and the implant-plus-hearing-aid profile: Comparing self-assessed and measured abilities.","volume":"47","author":"Noble","year":"2008","journal-title":"Int J Audiol"},{"key":"R34-20230726","doi-asserted-by":"crossref","first-page":"353","DOI":"10.3766\/jaaa.20.6.4","article-title":"Recognition and localization of speech by adult cochlear implant recipients wearing a digital hearing aid in the nonimplanted ear (bimodal hearing).","volume":"20","author":"Potts","year":"2009","journal-title":"J Am Acad Audiol"},{"key":"R35-20230726","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1097\/AUD.0b013e3182a2c814","article-title":"Fundamental frequency information for speech recognition via bimodal stimulation: Cochlear implant in one ear and hearing aid in the other.","volume":"35","author":"Shpak","year":"2014","journal-title":"Ear Hear"},{"key":"R36-20230726","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1097\/01.HJ.0000325657.80281.9c","article-title":"Real-world preferences for linked bilateral processing.","volume":"61","author":"Smith","year":"2008","journal-title":"Hear J"},{"key":"R37-20230726","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1097\/01.HJ.0000361850.27208.35","article-title":"Binaural hearing aid communication shown to improve sound quality and localization.","volume":"62","author":"Sockalingam","year":"2009","journal-title":"Hear J"},{"key":"R38-20230726","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1097\/01.aud.0000252470.54246.54","article-title":"Speech understanding in background noise with the two-microphone adaptive beamformer BEAM in the nucleus freedom cochlear implant system.","volume":"28","author":"Spriet","year":"2007","journal-title":"Ear Hear"},{"key":"R39-20230726","doi-asserted-by":"crossref","first-page":"1654","DOI":"10.1121\/1.2434754","article-title":"Quantifying the effects of fast-acting compression on the envelope of speech.","volume":"121","author":"Stone","year":"2007","journal-title":"J Acoust Soc Am"},{"key":"R40-20230726","doi-asserted-by":"crossref","first-page":"1884","DOI":"10.1121\/1.3474236","article-title":"Advantage of bimodal fitting in prosody perception for children using a cochlear implant and a hearing aid.","volume":"128","author":"Straatman","year":"2010","journal-title":"J Acoust Soc Am"},{"key":"R41-20230726","doi-asserted-by":"crossref","first-page":"455","DOI":"10.1044\/jshr.2803.455","article-title":"A \u201crationalized\u201d arcsine transform.","volume":"28","author":"Studebaker","year":"1985","journal-title":"J Speech Hear Res"},{"key":"R42-20230726","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1097\/00003446-200204000-00003","article-title":"Patients utilizing a hearing aid and a cochlear implant: Speech perception and localization.","volume":"23","author":"Tyler","year":"2002","journal-title":"Ear Hear"},{"key":"R43-20230726","doi-asserted-by":"crossref","first-page":"388","DOI":"10.1097\/00020840-200310000-00014","article-title":"Update on bilateral cochlear implantation.","volume":"11","author":"Tyler","year":"2003","journal-title":"Curr Opin Otolaryngol Head Neck Surg"},{"key":"R44-20230726","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1016\/j.heares.2011.11.014","article-title":"Contrasting benefits from contralateral implants and hearing aids in cochlear implant users.","volume":"288","author":"van Hoesel","year":"2012","journal-title":"Hear Res"},{"key":"R49-20230726","doi-asserted-by":"crossref","first-page":"348","DOI":"10.1080\/14992020801895144","article-title":"LIST and LINT: Sentences and numbers for quantifying speech understanding in severely impaired listeners for Flanders and the Netherlands.","volume":"47","author":"van Wieringen","year":"(2008).","journal-title":"Int J Audiol"},{"key":"R45-20230726","doi-asserted-by":"crossref","first-page":"1671","DOI":"10.1121\/1.428451","article-title":"Method for the selection of sentence materials for efficient measurement of the speech reception threshold.","volume":"107","author":"Versfeld","year":"2000","journal-title":"J Acoust Soc Am"},{"key":"R46-20230726","article-title":"Frequency-dependent loudness balancing in bimodal cochlear implant users.","author":"Veugen","year":"2014","journal-title":"Submitted for publication"},{"key":"R47-20230726","doi-asserted-by":"crossref","first-page":"1004","DOI":"10.1121\/1.4773862","article-title":"Linking dynamic-range compression across the ears can improve speech intelligibility in spatially separated noise.","volume":"133","author":"Wiggins","year":"2013","journal-title":"J Acoust Soc Am"},{"key":"R48-20230726","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1097\/AUD.0b013e3181b7190c","article-title":"Information from the voice fundamental frequency (F0) region accounts for the majority of the benefit when acoustic stimulation is added to electric stimulation.","volume":"31","author":"Zhang","year":"2010","journal-title":"Ear Hear"}],"container-title":["Ear &amp; Hearing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00003446-201605000-00003","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,7,26]],"date-time":"2023-07-26T07:01:22Z","timestamp":1690354882000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00003446-201605000-00003"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,5]]},"references-count":45,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2016]]}},"URL":"https:\/\/doi.org\/10.1097\/aud.0000000000000260","relation":{},"ISSN":["0196-0202"],"issn-type":[{"value":"0196-0202","type":"print"}],"subject":[],"published":{"date-parts":[[2016,5]]}}}