{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,6]],"date-time":"2026-03-06T15:46:41Z","timestamp":1772812001170,"version":"3.50.1"},"reference-count":36,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","license":[{"start":{"date-parts":[[2016,5,1]],"date-time":"2016-05-01T00:00:00Z","timestamp":1462060800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2016,5]]},"abstract":"<jats:sec>\n            <jats:title>Objectives:<\/jats:title>\n            <jats:p>In natural hearing, cochlear mechanical compression is dynamically adjusted via the efferent medial olivocochlear reflex (MOCR). These adjustments probably help understanding speech in noisy environments and are not available to the users of current cochlear implants (CIs). The aims of the present study are to: (1) present a binaural CI sound processing strategy inspired by the control of cochlear compression provided by the contralateral MOCR in natural hearing; and (2) assess the benefits of the new strategy for understanding speech presented in competition with steady noise with a speech-like spectrum in various spatial configurations of the speech and noise sources.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Design:<\/jats:title>\n            <jats:p>Pairs of CI sound processors (one per ear) were constructed to mimic or not mimic the effects of the contralateral MOCR on compression. For the nonmimicking condition (standard strategy or STD), the two processors in a pair functioned similarly to standard clinical processors (i.e., with fixed back-end compression and independently of each other). When configured to mimic the effects of the MOCR (MOC strategy), the two processors communicated with each other and the amount of back-end compression in a given frequency channel of each processor in the pair decreased\/increased dynamically (so that output levels dropped\/increased) with increases\/decreases in the output energy from the corresponding frequency channel in the contralateral processor. Speech reception thresholds in speech-shaped noise were measured for 3 bilateral CI users and 2 single-sided deaf unilateral CI users. Thresholds were compared for the STD and MOC strategies in unilateral and bilateral listening conditions and for three spatial configurations of the speech and noise sources in simulated free-field conditions: speech and noise sources colocated in front of the listener, speech on the left ear with noise in front of the listener, and speech on the left ear with noise on the right ear. In both bilateral and unilateral listening, the electrical stimulus delivered to the test ear(s) was always calculated as if the listeners were wearing bilateral processors.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>In both unilateral and bilateral listening conditions, mean speech reception thresholds were comparable with the two strategies for colocated speech and noise sources, but were at least 2 dB lower (better) with the MOC than with the STD strategy for spatially separated speech and noise sources. In unilateral listening conditions, mean thresholds improved with increasing the spatial separation between the speech and noise sources regardless of the strategy but the improvement was significantly greater with the MOC strategy. In bilateral listening conditions, thresholds improved significantly with increasing the speech-noise spatial separation only with the MOC strategy.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>The MOC strategy (1) significantly improved the intelligibility of speech presented in competition with a spatially separated noise source, both in unilateral and bilateral listening conditions; (2) produced significant spatial release from masking in bilateral listening conditions, something that did not occur with fixed compression; and (3) enhanced spatial release from masking in unilateral listening conditions. The MOC strategy as implemented here, or a modified version of it, may be usefully applied in CIs and in hearing aids.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/aud.0000000000000273","type":"journal-article","created":{"date-parts":[[2016,2,11]],"date-time":"2016-02-11T09:04:02Z","timestamp":1455181442000},"page":"e138-e148","source":"Crossref","is-referenced-by-count":58,"title":["A Binaural Cochlear Implant Sound Coding Strategy Inspired by the Contralateral Medial Olivocochlear Reflex"],"prefix":"10.1097","volume":"37","author":[{"given":"Enrique A.","family":"Lopez-Poveda","sequence":"first","affiliation":[{"name":"Department of Biomedical Engineering, Duke University, Durham, North Carolina, USA."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Almudena","family":"Eustaquio-Mart\u00edn","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, Duke University, Durham, North Carolina, USA."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joshua S.","family":"Stohl","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, Duke University, Durham, North Carolina, USA."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robert D.","family":"Wolford","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, Duke University, Durham, North Carolina, USA."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Reinhold","family":"Schatzer","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, Duke University, Durham, North Carolina, USA."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Blake S.","family":"Wilson","sequence":"additional","affiliation":[{"name":"Department of Biomedical Engineering, Duke University, Durham, North Carolina, USA."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20230726","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1007\/s10162-013-0373-4","article-title":"Contralateral efferent reflex effects on threshold and suprathreshold psychoacoustical tuning curves at low and high frequencies.","volume":"14","author":"Aguilar","year":"2013","journal-title":"J Assoc Res Otolaryngol"},{"key":"R2-20230726","first-page":"251","article-title":"Contralateral efferent suppression of human hearing sensitivity.","volume":"8","author":"Aguilar","year":"2014","journal-title":"Front Syst Neurosci"},{"issue":"5 Pt 1","key":"R4-20230726","doi-asserted-by":"crossref","first-page":"2889","DOI":"10.1121\/1.2169918","article-title":"Time-course of the human medial olivocochlear reflex.","volume":"119","author":"Backus","year":"2006","journal-title":"J Acoust Soc Am"},{"key":"R6-20230726","first-page":"1","article-title":"Comparing binaural pre-processing strategies II: Speech intelligibility of bilateral cochlear implant users.","volume":"19","author":"Baumg\u00e4rtel","year":"2015a","journal-title":"Trends Hear"},{"key":"R7-20230726","first-page":"1","article-title":"Comparing binaural pre-processing strategies I: Instrumental evaluation.","volume":"19","author":"Baumg\u00e4rtel","year":"2015b","journal-title":"Trends Hear"},{"key":"R9-20230726","doi-asserted-by":"crossref","first-page":"608","DOI":"10.1097\/01.aud.0000245815.07623.db","article-title":"Effects of programming threshold and maplaw settings on acoustic thresholds and speech discrimination with the MED-EL COMBI 40+ cochlear implant.","volume":"27","author":"Boyd","year":"2006","journal-title":"Ear Hear"},{"key":"R10-20230726","doi-asserted-by":"crossref","first-page":"580","DOI":"10.1097\/AUD.0000000000000044","article-title":"Binaural enhancement for bilateral cochlear implant users.","volume":"35","author":"Brown","year":"2014","journal-title":"Ear Hear"},{"key":"R11-20230726","doi-asserted-by":"crossref","first-page":"943","DOI":"10.1121\/1.3273893","article-title":"A computer model of auditory efferent suppression: Implications for the recognition of speech in noise.","volume":"127","author":"Brown","year":"2010","journal-title":"J Acoust Soc Am"},{"key":"R12-20230726","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1007\/s10162-011-0310-3","article-title":"Modeling the anti-masking effects of the olivocochlear reflex in auditory nerve responses to tones in sustained noise.","volume":"13","author":"Chintanpalli","year":"2012","journal-title":"J Assoc Res Otolaryngol"},{"key":"R13-20230726","doi-asserted-by":"crossref","first-page":"1535","DOI":"10.1121\/1.4742745","article-title":"A frequency-selective feedback model of auditory efferent suppression and its implications for the recognition of speech in noise.","volume":"132","author":"Clark","year":"2012","journal-title":"J Acoust Soc Am"},{"issue":"Pt 1","key":"R14-20230726","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1113\/jphysiol.2006.114991","article-title":"Efferent-mediated control of basilar membrane motion.","volume":"576","author":"Cooper","year":"2006","journal-title":"J Physiol"},{"key":"R16-20230726","doi-asserted-by":"crossref","first-page":"7115","DOI":"10.1038\/ncomms8115","article-title":"Type II spiral ganglion afferent neurons drive medial olivocochlear reflex suppression of the cochlear amplifier.","volume":"6","author":"Froud","year":"2015","journal-title":"Nat Commun"},{"key":"R17-20230726","doi-asserted-by":"crossref","first-page":"3907","DOI":"10.1121\/1.412407","article-title":"HRTF measurements of a KEMAR.","volume":"97","author":"Gardner","year":"1995","journal-title":"J Acoust Soc Am"},{"key":"R19-20230726","doi-asserted-by":"crossref","first-page":"589","DOI":"10.1097\/01.aud.0000240507.83072.e7","article-title":"Olivocochlear efferents: Anatomy, physiology, function, and the measurement of efferent effects in humans.","volume":"27","author":"Guinan","year":"2006","journal-title":"Ear Hear"},{"key":"R20-20230726","doi-asserted-by":"crossref","first-page":"521","DOI":"10.1007\/s10162-002-3037-3","article-title":"Medial olivocochlear efferent reflex in humans: Otoacoustic emission (OAE) measurement issues and the advantages of stimulus frequency OAEs.","volume":"4","author":"Guinan","year":"2003","journal-title":"J Assoc Res Otolaryngol"},{"key":"R21-20230726","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1016\/S0378-5955(96)00138-4","article-title":"Contralateral suppression of transient-evoked otoacoustic emissions in humans: Intensity effects.","volume":"101","author":"Hood","year":"1996","journal-title":"Hear Res"},{"key":"R22-20230726","doi-asserted-by":"crossref","first-page":"e45296","DOI":"10.1371\/journal.pone.0045296","article-title":"Interaural level differences do not suffice for restoring spatial release from masking in simulated cochlear implant listening.","volume":"7","author":"Ihlefeld","year":"2012","journal-title":"PLoS One"},{"key":"R23-20230726","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1159\/000046814","article-title":"Contralateral masking in cochlear implant users with residual hearing in the non-implanted ear.","volume":"6","author":"James","year":"2001","journal-title":"Audiol Neurootol"},{"key":"R24-20230726","doi-asserted-by":"crossref","first-page":"214","DOI":"10.3389\/fnins.2014.00214","article-title":"Across-frequency behavioral estimates of the contribution of inner and outer hair cell dysfunction to individualized audiometric loss.","volume":"8","author":"Johannesen","year":"2014","journal-title":"Front Neurosci"},{"key":"R27-20230726","doi-asserted-by":"crossref","first-page":"862","DOI":"10.1016\/j.specom.2006.03.004","article-title":"Effects of age on speech understanding in normal hearing listeners: Relationship between the auditory efferent system and speech intelligibility in noise","volume":"48","author":"Kim","year":"2006","journal-title":"Speech Commun"},{"key":"R28-20230726","first-page":"18","article-title":"Consumers rate improvements sought in hearing instruments.","volume":"9","author":"Kochkin","year":"2002","journal-title":"Hear Rev"},{"key":"R29-20230726","first-page":"82","article-title":"Real-time multiband dynamic compression and noise reduction for binaural hearing aids.","volume":"30","author":"Kollmeier","year":"1993","journal-title":"J Rehabil Res Dev"},{"key":"R30-20230726","doi-asserted-by":"crossref","first-page":"459","DOI":"10.1007\/s10162-009-0163-1","article-title":"Human medial olivocochlear reflex: Effects as functions of contralateral, ipsilateral, and bilateral elicitor bandwidths.","volume":"10","author":"Lilaonitkul","year":"2009a","journal-title":"J Assoc Res Otolaryngol"},{"key":"R31-20230726","doi-asserted-by":"crossref","first-page":"1394","DOI":"10.1152\/jn.90925.2008","article-title":"Reflex control of the human inner ear: A half-octave offset in medial efferent feedback that is consistent with an efferent role in the control of masking.","volume":"101","author":"Lilaonitkul","year":"2009b","journal-title":"J Neurophysiol"},{"key":"R32-20230726","doi-asserted-by":"crossref","first-page":"962","DOI":"10.1121\/1.4773262","article-title":"Central masking with bilateral cochlear implants.","volume":"133","author":"Lin","year":"2013","journal-title":"J Acoust Soc Am"},{"key":"R34-20230726","doi-asserted-by":"crossref","first-page":"485","DOI":"10.1007\/s10162-012-0327-2","article-title":"Behavioral estimates of the contribution of inner and outer hair cell dysfunction to individualized audiometric loss.","volume":"13","author":"Lopez-Poveda","year":"2012","journal-title":"J Assoc Res Otolaryngol"},{"key":"R35-20230726","doi-asserted-by":"crossref","DOI":"10.1007\/978-3-319-25474-6_12","article-title":"Roles of the contralateral efferent reflex in hearing demonstrated with cochlear implants.","author":"Lopez-Poveda","year":"2016","journal-title":"Adv Exp Med Biol"},{"key":"R36-20230726","doi-asserted-by":"crossref","first-page":"1759","DOI":"10.1152\/jn.1997.77.4.1759","article-title":"Medial olivocochlear efferent system in humans studied with amplitude-modulated tones.","volume":"77","author":"Maison","year":"1997","journal-title":"J Neurophysiol"},{"key":"R37-20230726","doi-asserted-by":"crossref","first-page":"5542","DOI":"10.1523\/JNEUROSCI.5027-12.2013","article-title":"Efferent feedback minimizes cochlear neuropathy from moderate noise exposure.","volume":"33","author":"Maison","year":"2013","journal-title":"J Neurosci"},{"key":"R38-20230726","doi-asserted-by":"crossref","first-page":"1085","DOI":"10.1121\/1.408469","article-title":"Development of the hearing in noise test for the measurement of speech reception thresholds in quiet and in noise.","volume":"95","author":"Nilsson","year":"1994","journal-title":"J Acoust Soc Am"},{"key":"R40-20230726","doi-asserted-by":"crossref","first-page":"1305","DOI":"10.1152\/physrev.2001.81.3.1305","article-title":"Mechanics of the mammalian cochlea.","volume":"81","author":"Robles","year":"2001","journal-title":"Physiol Rev"},{"key":"R42-20230726","doi-asserted-by":"crossref","first-page":"2329","DOI":"10.1121\/1.4794386","article-title":"Effects of dynamic range compression on spatial selective auditory attention in normal-hearing listeners.","volume":"133","author":"Schwartz","year":"2013","journal-title":"J Acoust Soc Am"},{"key":"R43-20230726","doi-asserted-by":"crossref","first-page":"3859","DOI":"10.1523\/JNEUROSCI.18-10-03859.1998","article-title":"Long-term effects of sectioning the olivocochlear bundle in neonatal cats.","volume":"18","author":"Walsh","year":"1998","journal-title":"J Neurosci"},{"key":"R44-20230726","doi-asserted-by":"crossref","first-page":"1004","DOI":"10.1121\/1.4773862","article-title":"Linking dynamic-range compression across the ears can improve speech intelligibility in spatially separated noise.","volume":"133","author":"Wiggins","year":"2013","journal-title":"J Acoust Soc Am"},{"key":"R45-20230726","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1038\/352236a0","article-title":"Better speech recognition with cochlear implants.","volume":"352","author":"Wilson","year":"1991","journal-title":"Nature"},{"issue":"4 Suppl","key":"R46-20230726","doi-asserted-by":"crossref","first-page":"73S","DOI":"10.1097\/00003446-200508001-00009","article-title":"Two new directions in speech processor design for cochlear implants.","volume":"26","author":"Wilson","year":"2005","journal-title":"Ear Hear"}],"container-title":["Ear &amp; Hearing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00003446-201605000-00015","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,7,26]],"date-time":"2023-07-26T07:03:27Z","timestamp":1690355007000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00003446-201605000-00015"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,5]]},"references-count":36,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2016]]}},"URL":"https:\/\/doi.org\/10.1097\/aud.0000000000000273","relation":{},"ISSN":["0196-0202"],"issn-type":[{"value":"0196-0202","type":"print"}],"subject":[],"published":{"date-parts":[[2016,5]]}}}