{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,5]],"date-time":"2025-11-05T06:25:26Z","timestamp":1762323926234},"reference-count":48,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2016,7]]},"abstract":"<jats:sec>\n            <jats:title>Objectives:<\/jats:title>\n            <jats:p>Wideband acoustic immittance (WAI) measurements are capable of quantifying middle ear performance over a wide range of frequencies relevant to human hearing. Static pressure in the middle ear cavity affects sound transmission to the cochlea, but few datasets exist to quantify the relationship between middle ear transmission and the static pressure. In this study, WAI measurements of normal ears are analyzed in both negative middle ear pressure (NMEP) and ambient middle ear pressure (AMEP) conditions, with a focus on the effects of NMEP in individual ears.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Design:<\/jats:title>\n            <jats:p>Eight subjects with normal middle ear function were trained to induce consistent NMEPs, quantified by the tympanic peak pressure (TPP) and WAI. The effects of NMEP on the wideband power absorbance level are analyzed for individual ears. Complex (magnitude and phase) WAI quantities at the tympanic membrane (TM) are studied by removing the delay due to the residual ear canal (REC) volume between the probe tip and the TM. WAI results are then analyzed using a simplified classical model of the middle ear.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>For the 8 ears presented here, NMEP has the largest and most significant effect across ears from 0.8 to 1.9\u2009kHz, resulting in reduced power absorbance by the middle ear and cochlea. On average, NMEP causes a decrease in the power absorbance level for low- to mid-frequencies, and a small increase above about 4\u2009kHz. The effects of NMEP on WAI quantities, including the absorbance level and TM impedance, vary considerably across ears. The complex WAI at the TM and fitted model parameters show that NMEP causes a decrease in the aggregate compliance at the TM. Estimated REC delays show little to no dependence on NMEP.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>In agreement with previous results, these data show that the power absorbance level is most sensitive to NMEP around 1\u2009kHz. The REC effect is removed from WAI measurements, allowing for direct estimation of complex WAI at the TM. These estimates show NMEP effects consistent with an increased stiffness in the middle ear, which could originate from the TM, tensor tympani, annular ligament, or other middle ear structures. Model results quantify this nonlinear, stiffness-related change in a systematic way, that is not dependent on averaging WAI results in frequency bands. Given the variability of pressure effects, likely related to intersubject variability at AMEP, TPP is not a strong predictor of change in WAI at the TM. More data and modeling will be needed to better quantify the relationship between NMEP, WAI, and middle ear transmission.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/aud.0000000000000280","type":"journal-article","created":{"date-parts":[[2016,2,12]],"date-time":"2016-02-12T14:06:41Z","timestamp":1455286001000},"page":"452-464","source":"Crossref","is-referenced-by-count":16,"title":["Effects of Negative Middle Ear Pressure on Wideband Acoustic Immittance in Normal-Hearing Adults"],"prefix":"10.1097","volume":"37","author":[{"given":"Sarah R.","family":"Robinson","sequence":"first","affiliation":[{"name":"St. John\u2019s University, Queens, New York, USA."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Suzanne","family":"Thompson","sequence":"additional","affiliation":[{"name":"St. John\u2019s University, Queens, New York, USA."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jont B.","family":"Allen","sequence":"additional","affiliation":[{"name":"St. John\u2019s University, Queens, New York, USA."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"issue":"4 Suppl 2","key":"R2-20230726","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1682\/JRRD.2005.04.0064","article-title":"Evaluation of human middle ear function via an acoustic power assessment.","volume":"42","author":"Allen","year":"2005","journal-title":"J Rehabil Res Dev"},{"key":"R3-20230726","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1097\/MAO.0000000000000382","article-title":"Voluntary eardrum movement: A marker for tensor tympani contraction?","volume":"36","author":"Aron","year":"2015","journal-title":"Otol Neurotol"},{"key":"R4-20230726","doi-asserted-by":"crossref","first-page":"1021","DOI":"10.1002\/lary.23711","article-title":"Effects of tensor tympani muscle contraction on the middle ear and markers of a contracted muscle.","volume":"123","author":"Bance","year":"2013","journal-title":"Laryngoscope"},{"key":"R6-20230726","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1288\/00005537-197402000-00006","article-title":"Studies in tympanometry: Validation of the present technique for determining intra-tympanic pressures through the intact eardrum.","volume":"84","author":"Eliachar","year":"1974","journal-title":"Laryngoscope"},{"key":"R7-20230726","doi-asserted-by":"crossref","first-page":"1029","DOI":"10.1044\/jslhr.4205.1029","article-title":"Acoustic reflex detection using wide-band acoustic reflectance, admittance, and power measurements.","volume":"42","author":"Feeney","year":"1999","journal-title":"J Speech Lang Hear Res"},{"key":"R8-20230726","doi-asserted-by":"crossref","first-page":"901","DOI":"10.1044\/1092-4388(2003\/070)","article-title":"Wideband energy reflectance measurements in adults with middle-ear disorders.","volume":"46","author":"Feeney","year":"2003","journal-title":"J Speech Lang Hear Res"},{"key":"R9-20230726","doi-asserted-by":"crossref","first-page":"421","DOI":"10.1097\/01.aud.0000145110.60657.73","article-title":"Wideband reflectance measures of the ipsilateral acoustic stapedius reflex threshold.","volume":"25","author":"Feeney","year":"2004","journal-title":"Ear Hear"},{"issue":"Suppl 1","key":"R10-20230726","doi-asserted-by":"crossref","first-page":"78S","DOI":"10.1097\/AUD.0b013e31829c726b","article-title":"Consensus statement: Eriksholm workshop on wideband absorbance measures of the middle ear.","volume":"34","author":"Feeney","year":"2013","journal-title":"Ear Hear"},{"key":"R11-20230726","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1017\/S0022215100088411","article-title":"Evaluation of Eustachian tube function.","volume":"94","author":"Holmquist","year":"1980","journal-title":"J Laryngol Otol"},{"key":"R12-20230726","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1001\/archotol.1981.00790400023004","article-title":"Simple impedance test for Eustachian tube function.","volume":"107","author":"Honjo","year":"1981","journal-title":"Arch Otolaryngol"},{"key":"R13-20230726","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1121\/1.1907041","article-title":"The analogous acoustical impedance for discontinuities and constrictions of circular cross section.","volume":"25","author":"Karal","year":"1953","journal-title":"J Acoust Soc Am"},{"key":"R14-20230726","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1121\/1.390300","article-title":"Acoustical wave propagation in cylindrical ducts: Transmission line parameter approximations for isothermal and nonisothermal boundary conditions.","volume":"75","author":"Keefe","year":"1984","journal-title":"J Acoust Soc Am"},{"key":"R15-20230726","doi-asserted-by":"crossref","first-page":"779","DOI":"10.1121\/1.3531796","article-title":"Specification of absorbed-sound power in the ear canal: Application to suppression of stimulus frequency otoacoustic emissions.","volume":"129","author":"Keefe","year":"2011","journal-title":"J Acoust Soc Am"},{"key":"R16-20230726","doi-asserted-by":"crossref","first-page":"2617","DOI":"10.1121\/1.407347","article-title":"Ear-canal impedance and reflection coefficient in human infants and adults.","volume":"94","author":"Keefe","year":"1993","journal-title":"J Acoust Soc Am"},{"key":"R17-20230726","doi-asserted-by":"crossref","first-page":"75","DOI":"10.3109\/01050398809070695","article-title":"Network model for the human middle ear.","volume":"17","author":"Kringlebotn","year":"1988","journal-title":"Scand Audiol"},{"key":"R18-20230726","doi-asserted-by":"crossref","first-page":"1756","DOI":"10.1121\/1.4895696","article-title":"Nonlinear stiffness characteristics of the annular ligament.","volume":"136","author":"Lauxmann","year":"2014","journal-title":"J Acoust Soc Am"},{"key":"R19-20230726","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1121\/1.387995","article-title":"Input impedance of the cochlea in cat.","volume":"72","author":"Lynch","year":"1982","journal-title":"J Acoust Soc Am"},{"key":"R20-20230726","doi-asserted-by":"crossref","first-page":"218","DOI":"10.1097\/00003446-199706000-00005","article-title":"Effect of negative middle-ear pressure on transient-evoked otoacoustic emissions.","volume":"18","author":"Marshall","year":"1997","journal-title":"Ear Hear"},{"issue":"2","key":"R21-20230726","doi-asserted-by":"crossref","first-page":"250","DOI":"10.1121\/1.1908029","article-title":"Improved technique for detailed measurements of the middle ear impedance.","volume":"32","author":"M\u00f8ller","year":"1960","journal-title":"J Acoust Soc Am"},{"key":"R23-20230726","doi-asserted-by":"crossref","first-page":"E276","DOI":"10.1002\/lary.25141","article-title":"Noninvasive depth-resolved optical measurements of the tympanic membrane and middle ear for differentiating otitis media.","volume":"125","author":"Monroy","year":"2015","journal-title":"Laryngoscope"},{"key":"R24-20230726","doi-asserted-by":"crossref","first-page":"170","DOI":"10.1177\/1084713810381771","article-title":"Auditory brainstem circuits that mediate the middle ear muscle reflex.","volume":"14","author":"Mukerji","year":"2010","journal-title":"Trends Amplif"},{"key":"R25-20230726","doi-asserted-by":"crossref","first-page":"390","DOI":"10.3109\/00016489709113411","article-title":"Effect of middle ear pressure change on middle ear mechanics.","volume":"117","author":"Murakami","year":"1997","journal-title":"Acta Otolaryngol"},{"key":"R26-20230726","first-page":"703","article-title":"Effect of increased inner ear pressure on middle ear mechanics.","volume":"118","author":"Myers","year":"1998","journal-title":"JAMA Otolaryngol Head Neck Surg"},{"key":"R27-20230726","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1097\/AUD.0b013e31822ccba0","article-title":"Comparison of ear-canal reflectance and umbo velocity in patients with conductive hearing loss: A preliminary study.","volume":"33","author":"Nakajima","year":"2012","journal-title":"Ear Hear"},{"key":"R28-20230726","doi-asserted-by":"crossref","first-page":"9529","DOI":"10.1073\/pnas.1201592109","article-title":"Noninvasive in vivo optical detection of biofilm in the human middle ear.","volume":"109","author":"Nguyen","year":"2012","journal-title":"Proc Natl Acad Sci USA"},{"key":"R29-20230726","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1016\/j.heares.2013.04.001","article-title":"Investigation of bacterial biofilm in the human middle ear using optical coherence tomography and acoustic measurements.","volume":"301","author":"Nguyen","year":"2013","journal-title":"Hear Res"},{"key":"R31-20230726","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1016\/j.heares.2009.12.015","article-title":"Time-domain \u201cwave\u201d model of the human tympanic membrane.","volume":"263","author":"Parent","year":"2010","journal-title":"Hear Res"},{"key":"R32-20230726","doi-asserted-by":"crossref","first-page":"533","DOI":"10.1097\/AUD.0b013e3181731e3e","article-title":"Changes in transient-evoked otoacoustic emission levels with negative tympanometric peak pressure in infants and toddlers.","volume":"29","author":"Prieve","year":"2008","journal-title":"Ear Hear"},{"key":"R33-20230726","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1097\/AUD.0b013e31826fe611","article-title":"Identification of conductive hearing loss in young infants using tympanometry and wideband reflectance.","volume":"34","author":"Prieve","year":"2013","journal-title":"Ear Hear"},{"key":"R35-20230726","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1121\/1.400675","article-title":"A parametric study of cochlear input impedance.","volume":"89","author":"Puria","year":"1991","journal-title":"J Acoust Soc Am"},{"key":"R36-20230726","doi-asserted-by":"crossref","first-page":"3463","DOI":"10.1121\/1.423930","article-title":"Measurements and model of the cat middle ear: Evidence of tympanic membrane acoustic delay.","volume":"104","author":"Puria","year":"1998","journal-title":"J Acoust Soc Am"},{"key":"R37-20230726","doi-asserted-by":"crossref","first-page":"1025","DOI":"10.1121\/1.386953","article-title":"Measurement of the acoustic input immittance of the human ear.","volume":"70","author":"Rabinowitz","year":"1981","journal-title":"J Acoust Soc Am"},{"key":"R38-20230726","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1016\/j.heares.2013.03.004","article-title":"Characterizing the ear canal acoustic impedance and reflectance by pole-zero fitting.","volume":"301","author":"Robinson","year":"2013","journal-title":"Hear Res"},{"key":"R39-20230726","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1097\/AUD.0b013e31822ccb76","article-title":"Ear-canal reflectance, umbo velocity, and tympanometry in normal-hearing adults.","volume":"33","author":"Rosowski","year":"2012","journal-title":"Ear Hear"},{"key":"R40-20230726","doi-asserted-by":"crossref","first-page":"3607","DOI":"10.1121\/1.2722213","article-title":"Wideband ipsilateral measurements of middle-ear muscle reflex thresholds in children and adults.","volume":"121","author":"Schairer","year":"2007","journal-title":"J Acoust Soc Am"},{"key":"R41-20230726","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1097\/AUD.0b013e3181976a14","article-title":"Energy reflectance and tympanometry in normal and otosclerotic ears.","volume":"30","author":"Shahnaz","year":"2009","journal-title":"Ear Hear"},{"key":"R42-20230726","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1044\/jshr.2404.557","article-title":"An evaluation of tympanometric estimates of ear canal volume.","volume":"24","author":"Shanks","year":"1981","journal-title":"J Speech Hear Res"},{"key":"R44-20230726","doi-asserted-by":"crossref","first-page":"354","DOI":"10.1044\/jshd.5304.354","article-title":"Tympanometry.","volume":"53","author":"Shanks","year":"1988","journal-title":"J Speech Hear Disord"},{"key":"R45-20230726","doi-asserted-by":"crossref","first-page":"332","DOI":"10.1121\/1.4807509","article-title":"Wideband energy reflectance measurements: Effects of negative middle ear pressure and application of a pressure compensation procedure.","volume":"134","author":"Shaver","year":"2013","journal-title":"J Acoust Soc Am"},{"key":"R46-20230726","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1097\/AUD.0b013e31819769e1","article-title":"Effects of negative middle ear pressure on distortion product otoacoustic emissions and application of a compensation procedure in humans.","volume":"30","author":"Sun","year":"2009","journal-title":"Ear Hear"},{"key":"R47-20230726","doi-asserted-by":"crossref","first-page":"695","DOI":"10.1097\/AUD.0000000000000185","article-title":"Negative middle ear pressure and composite and component distortion product otoacoustic emissions.","volume":"36","author":"Thompson","year":"2015","journal-title":"Ear Hear"},{"key":"R48-20230726","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1080\/00016489850183458","article-title":"Continuous long-term measurements of the middle ear pressure in subjects without a history of ear disease.","volume":"118","author":"Tideholm","year":"1998","journal-title":"Acta Otolaryngol"},{"key":"R49-20230726","doi-asserted-by":"crossref","first-page":"45","DOI":"10.3109\/01050397509075014","article-title":"On the w-notching of tympanograms.","volume":"4","author":"Vanhuyse","year":"1975","journal-title":"Scand Audiol"},{"key":"R50-20230726","doi-asserted-by":"crossref","first-page":"372","DOI":"10.1121\/1.408329","article-title":"Measurement of acoustic impedance and reflectance in the human ear canal.","volume":"95","author":"Voss","year":"1994","journal-title":"J Acoust Soc Am"},{"key":"R51-20230726","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1097\/AUD.0b013e31823235b5","article-title":"Effects of middle-ear disorders on power reflectance measured in cadaveric ear canals.","volume":"33","author":"Voss","year":"2012","journal-title":"Ear Hear"},{"key":"R52-20230726","doi-asserted-by":"crossref","first-page":"651","DOI":"10.1097\/AUD.0b013e318174f07c","article-title":"Sources of variability in reflectance measurements on normal cadaver ears.","volume":"29","author":"Voss","year":"2008","journal-title":"Ear Hear"},{"issue":"Suppl 1","key":"R53-20230726","doi-asserted-by":"crossref","first-page":"60S","DOI":"10.1097\/AUD.0b013e31829cfd64","article-title":"Factors that introduce intrasubject variability into ear-canal absorbance measurements.","volume":"34","author":"Voss","year":"2013","journal-title":"Ear Hear"},{"key":"R54-20230726","doi-asserted-by":"crossref","first-page":"1514","DOI":"10.1121\/1.1918382","article-title":"Analysis of the middle-ear function. Part I: Input impedance.","volume":"34","author":"Zwislocki","year":"1962","journal-title":"J Acoust Soc Am"}],"container-title":["Ear &amp; Hearing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00003446-201607000-00009","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,7,26]],"date-time":"2023-07-26T07:09:31Z","timestamp":1690355371000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00003446-201607000-00009"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,7]]},"references-count":48,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2016]]}},"URL":"https:\/\/doi.org\/10.1097\/aud.0000000000000280","relation":{},"ISSN":["0196-0202"],"issn-type":[{"value":"0196-0202","type":"print"}],"subject":[],"published":{"date-parts":[[2016,7]]}}}