{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T01:33:57Z","timestamp":1787621637869,"version":"build-2736575974"},"reference-count":19,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2016,9]]},"abstract":"<jats:sec>\n            <jats:title>Objective:<\/jats:title>\n            <jats:p>The objective is to develop methods to utilize newborn reflectance measures for the identification of middle-ear transient conditions (e.g., middle-ear fluid) during the newborn period and ultimately during the first few months of life. Transient middle-ear conditions are a suspected source of failure to pass a newborn hearing screening. The ability to identify a conductive loss during the screening procedure could enable the referred ear to be either (1) cleared of a middle-ear condition and recommended for more extensive hearing assessment as soon as possible, or (2) suspected of a transient middle-ear condition, and if desired, be rescreened before more extensive hearing assessment.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Design:<\/jats:title>\n            <jats:p>Reflectance measurements are reported from full-term, healthy, newborn babies in which one ear referred and one ear passed an initial auditory brainstem response newborn hearing screening and a subsequent distortion product otoacoustic emission screening on the same day. These same subjects returned for a detailed follow-up evaluation at age 1 month (range 14 to 35 days). In total, measurements were made on 30 subjects who had a unilateral refer near birth (during their first 2 days of life) and bilateral normal hearing at follow-up (about 1 month old). Three specific comparisons were made: (1) Association of ear\u2019s state with power reflectance near birth (referred versus passed ear), (2) Changes in power reflectance of normal ears between newborn and 1 month old (maturation effects), and (3) Association of ear\u2019s newborn state (referred versus passed) with ear\u2019s power reflectance at 1 month. In addition to these measurements, a set of preliminary data selection criteria were developed to ensure that analyzed data were not corrupted by acoustic leaks and other measurement problems.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Within 2 days of birth, the power reflectance measured in newborn ears with transient middle-ear conditions (referred newborn hearing screening and passed hearing assessment at age 1 month) was significantly greater than power reflectance on newborn ears that passed the newborn hearing screening across all frequencies (500 to 6000 Hz). Changes in power reflectance in normal ears from newborn to 1 month appear in approximately the 2000 to 5000 Hz range but are not present at other frequencies. The power reflectance at age 1 month does not depend significantly on the ear\u2019s state near birth (refer or pass hearing screening) for frequencies above 700 Hz; there might be small differences at lower frequencies.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>Power reflectance measurements are significantly different for ears that pass newborn hearing screening and ears that refer with middle-ear transient conditions. At age 1 month, about 90% of ears that referred at birth passed an auditory brainstem response hearing evaluation; within these ears the power reflectance at 1 month did not differ between the ear that initially referred at birth and the ear that passed the hearing screening at birth for frequencies above 700 Hz. This study also proposes a preliminary set of criteria for determining when reflectance measures on young babies are corrupted by acoustic leaks, probes against the ear canal, or other measurement problems. Specifically proposed are \u201cdata selection criteria\u201d that depend on the power reflectance, impedance magnitude, and impedance angle. Additional data collected in the future are needed to improve and test these proposed criteria.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/aud.0000000000000293","type":"journal-article","created":{"date-parts":[[2016,4,19]],"date-time":"2016-04-19T17:24:35Z","timestamp":1461086675000},"page":"560-571","source":"Crossref","is-referenced-by-count":19,"title":["Reflectance Measures from Infant Ears With Normal Hearing and Transient Conductive Hearing Loss"],"prefix":"10.1097","volume":"37","author":[{"given":"Susan E.","family":"Voss","sequence":"first","affiliation":[{"name":"Department of Mathematics and Statistics, Amherst College, Amherst, Massachusetts, USA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Barbara S.","family":"Herrmann","sequence":"additional","affiliation":[{"name":"Department of Mathematics and Statistics, Amherst College, Amherst, Massachusetts, USA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicholas J.","family":"Horton","sequence":"additional","affiliation":[{"name":"Department of Mathematics and Statistics, Amherst College, Amherst, Massachusetts, USA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elizabeth A.","family":"Amadei","sequence":"additional","affiliation":[{"name":"Department of Mathematics and Statistics, Amherst College, Amherst, Massachusetts, USA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sharon G.","family":"Kujawa","sequence":"additional","affiliation":[{"name":"Department of Mathematics and Statistics, Amherst College, Amherst, Massachusetts, USA."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20231017","doi-asserted-by":"crossref","first-page":"471","DOI":"10.3766\/jaaa.25.5.6","article-title":"Wideband absorbance in young infants (0-6 months): A cross-sectional study.","volume":"25","author":"Aithal","year":"2014","journal-title":"J Am Acad Audiol"},{"key":"R2-20231017","doi-asserted-by":"crossref","first-page":"e237","DOI":"10.1097\/AUD.0000000000000175","article-title":"Wideband absorbance outcomes in newborns: A comparison with high-frequency tympanometry, automated brainstem response, and transient evoked and distortion product otoacoustic emissions.","volume":"36","author":"Aithal","year":"2015","journal-title":"Ear Hear"},{"key":"R4-20231017","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1001\/jamaoto.2013.1229","article-title":"Children with sensorineural hearing loss after passing the newborn hearing screen.","volume":"139","author":"Dedhia","year":"2013","journal-title":"JAMA Otolaryngol Head Neck Surg"},{"issue":"6 Pt 1","key":"R5-20231017","doi-asserted-by":"crossref","first-page":"597","DOI":"10.1016\/S0194-5998(97)70234-1","article-title":"Neonatal hearing screening with otoscopy, auditory brain stem response, and otoacoustic emissions.","volume":"116","author":"Doyle","year":"1997","journal-title":"Otolaryngol Head Neck Surg"},{"key":"R6-20231017","first-page":"477","article-title":"External and middle ear effects on infant hearing screening test results.","volume":"122","author":"Doyle","year":"2000","journal-title":"Otolaryngol Head Neck Surg"},{"key":"R7-20231017","doi-asserted-by":"crossref","first-page":"318","DOI":"10.1097\/00129492-200405000-00020","article-title":"Neonatal middle ear effusion predicts chronic otitis media with effusion.","volume":"25","author":"Doyle","year":"2004","journal-title":"Otol Neurotol"},{"key":"R8-20231017","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1044\/1059-0889.0402.06","article-title":"Automated infant hearing screening using the ABR: Development and validation.","volume":"4","author":"Herrmann","year":"1995","journal-title":"Am J Audiol"},{"key":"R9-20231017","doi-asserted-by":"crossref","first-page":"1","DOI":"10.3109\/00206099109072866","article-title":"Developmental changes in multifrequency tympanograms.","volume":"30","author":"Holte","year":"1991","journal-title":"Audiology"},{"key":"R10-20231017","doi-asserted-by":"crossref","first-page":"309","DOI":"10.3766\/jaaa.19.4.4","article-title":"Wideband middle ear power measurement in infants and children.","volume":"19","author":"Hunter","year":"2008","journal-title":"J Am Acad Audiol"},{"key":"R11-20231017","doi-asserted-by":"crossref","first-page":"599","DOI":"10.1097\/AUD.0b013e3181e40ca7","article-title":"Wideband reflectance in newborns: Normative regions and relationship to hearing-screening results.","volume":"31","author":"Hunter","year":"2010","journal-title":"Ear Hear"},{"key":"R12-20231017","doi-asserted-by":"crossref","first-page":"898","DOI":"10.1542\/peds.2007-2333","article-title":"Year 2007 position statements: Principles and guidelines for early hearing detection and intervention programs.","volume":"120","year":"2007","journal-title":"Pediatrics"},{"key":"R13-20231017","doi-asserted-by":"crossref","first-page":"2617","DOI":"10.1121\/1.407347","article-title":"Ear-canal impedance and reflection coefficient in human infants and adults.","volume":"94","author":"Keefe","year":"1993","journal-title":"J Acoust Soc Am"},{"key":"R14-20231017","doi-asserted-by":"crossref","first-page":"443","DOI":"10.1097\/00003446-200010000-00009","article-title":"Identification of neonatal hearing impairment: Ear-canal measurements of acoustic admittance and reflectance in neonates.","volume":"21","author":"Keefe","year":"2000","journal-title":"Ear Hear"},{"key":"R15-20231017","doi-asserted-by":"crossref","first-page":"746","DOI":"10.1097\/AUD.0b013e3181e68e68","article-title":"Normative reflectance and transmittance measurements on healthy newborn and 1-month-old infants.","volume":"31","author":"Merchant","year":"2010","journal-title":"Ear Hear"},{"key":"R16-20231017","doi-asserted-by":"crossref","first-page":"2106","DOI":"10.1121\/1.2967864","article-title":"Effects of maturation on tympanometric wideband acoustic transfer functions in human infants.","volume":"124","author":"Sanford","year":"2008","journal-title":"J Acoust Soc Am"},{"key":"R17-20231017","doi-asserted-by":"crossref","first-page":"635","DOI":"10.1097\/AUD.0b013e3181b61cdc","article-title":"Sound-conduction effects on distortion-product otoacoustic emission screening outcomes in newborn infants: test performance of wideband acoustic transfer functions and 1-kHz tympanometry.","volume":"30","author":"Sanford","year":"2009","journal-title":"Ear Hear"},{"key":"R19-20231017","doi-asserted-by":"crossref","first-page":"2000","DOI":"10.1001\/jama.286.16.2000","article-title":"Universal newborn hearing screening: Summary of evidence.","volume":"286","author":"Thompson","year":"2001","journal-title":"JAMA"},{"key":"R20-20231017","doi-asserted-by":"crossref","first-page":"669","DOI":"10.1097\/AUD.0b013e31812f71b1","article-title":"Test-retest reliability of wideband reflectance measures in infants under screening and diagnostic test conditions.","volume":"28","author":"Vander Werff","year":"2007","journal-title":"Ear Hear"},{"key":"R21-20231017","doi-asserted-by":"crossref","first-page":"651","DOI":"10.1097\/AUD.0b013e318174f07c","article-title":"Sources of variability in reflectance measurements on normal cadaver ears.","volume":"29","author":"Voss","year":"2008","journal-title":"Ear Hear"}],"container-title":["Ear &amp; Hearing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00003446-201609000-00007","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,17]],"date-time":"2023-10-17T06:44:57Z","timestamp":1697525097000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00003446-201609000-00007"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,9]]},"references-count":19,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2016]]}},"URL":"https:\/\/doi.org\/10.1097\/aud.0000000000000293","relation":{},"ISSN":["0196-0202"],"issn-type":[{"value":"0196-0202","type":"print"}],"subject":[],"published":{"date-parts":[[2016,9]]}}}