{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,31]],"date-time":"2026-01-31T04:00:18Z","timestamp":1769832018309,"version":"3.49.0"},"reference-count":52,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2017,7]]},"abstract":"<jats:sec><jats:title>Objectives:<\/jats:title><jats:p>As a treatment for partial deafness with residual hearing in the lower frequency range, the combined acoustic and electric stimulation of the cochlea has become widespread. Acoustic stimulation is provided by a hearing aid\u2019s airborne sound and the electric stimulation by a cochlear implant electrode array, which may be inserted through the round window or a cochleostomy. To take advantage of that concept, it is essential to preserve residual hearing after surgery. Therefore, the intracochlear electrode array should not compromise the middle ear vibration transmission. This study investigates the influence of different electrode types and insertion paths on the middle ear transfer function and the inner ear fluid dynamics.<\/jats:p><\/jats:sec><jats:sec><jats:title>Design:<\/jats:title><jats:p>Sound-induced oval and round window net volume velocities were calculated from vibration measurements with laser vibrometers on six nonfixated human temporal bones. After baseline measurements in the \u201cnatural\u201d condition, a cochleostomy was drilled and closed with connective tissue. Then, four different electrode arrays were inserted through the cochleostomy. Afterwards, they were inserted through the round window while the cochleostomy was patched again with connective tissue.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results:<\/jats:title><jats:p>After having drilled a cochleostomy and electrode insertion, no systematic trends in the changes of oval and round window volume velocities were observed. Nearly all changes of middle ear transfer functions, as well as oval and round window volume velocity ratios, were statistically insignificant.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions:<\/jats:title><jats:p>Intracochlear electrode arrays do not significantly increase cochlear input impedance immediately after insertion. Any changes that may occur seem to be independent of electrode array type and insertion path.<\/jats:p><\/jats:sec>","DOI":"10.1097\/aud.0000000000000407","type":"journal-article","created":{"date-parts":[[2017,2,17]],"date-time":"2017-02-17T00:08:46Z","timestamp":1487290126000},"page":"e241-e255","source":"Crossref","is-referenced-by-count":3,"title":["The Impact of a Cochlear Implant Electrode Array on the Middle Ear Transfer Function"],"prefix":"10.1097","volume":"38","author":[{"given":"David","family":"Pazen","sequence":"first","affiliation":[{"name":"Jean Uhrmacher Institute for Clinical ENT-Research, University of Cologne, Cologne, Germany."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andreas","family":"Anagiotos","sequence":"additional","affiliation":[{"name":"Jean Uhrmacher Institute for Clinical ENT-Research, University of Cologne, Cologne, Germany."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maike","family":"N\u00fcnning","sequence":"additional","affiliation":[{"name":"Jean Uhrmacher Institute for Clinical ENT-Research, University of Cologne, Cologne, Germany."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Antoniu-Oreste","family":"Gostian","sequence":"additional","affiliation":[{"name":"Jean Uhrmacher Institute for Clinical ENT-Research, University of Cologne, Cologne, Germany."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Magdalene","family":"Ortmann","sequence":"additional","affiliation":[{"name":"Jean Uhrmacher Institute for Clinical ENT-Research, University of Cologne, Cologne, Germany."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dirk","family":"Beutner","sequence":"additional","affiliation":[{"name":"Jean Uhrmacher Institute for Clinical ENT-Research, University of Cologne, Cologne, Germany."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20230812","doi-asserted-by":"crossref","first-page":"1237","DOI":"10.1097\/00005537-200407000-00018","article-title":"Development and evaluation of an improved cochlear implant electrode design for electric acoustic stimulation.","volume":"114","author":"Adunka","year":"2004a","journal-title":"Laryngoscope"},{"key":"R2-20230812","doi-asserted-by":"crossref","first-page":"807","DOI":"10.1080\/00016480410018179","article-title":"Cochlear implantation via the round window membrane minimizes trauma to cochlear structures: A histologically controlled insertion study.","volume":"124","author":"Adunka","year":"2004b","journal-title":"Acta Otolaryngol"},{"key":"R3-20230812","doi-asserted-by":"crossref","first-page":"2509","DOI":"10.1002\/lary.23741","article-title":"Hearing preservation and speech perception outcomes with electric-acoustic stimulation after 12 months of listening experience.","volume":"123","author":"Adunka","year":"2013","journal-title":"Laryngoscope"},{"key":"R4-20230812","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1016\/S0378-5955(00)00240-9","article-title":"Human middle-ear sound transfer function and cochlear input impedance.","volume":"152","author":"Aibara","year":"2001","journal-title":"Hear Res"},{"key":"R5-20230812","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1097\/MAO.0000000000000586","article-title":"Young age is a positive prognostic factor for residual hearing preservation in conventional cochlear implantation.","volume":"36","author":"Anagiotos","year":"2014","journal-title":"Otol Neurotol"},{"issue":"10 Pt 1","key":"R7-20230812","doi-asserted-by":"crossref","first-page":"1002","DOI":"10.1288\/00005537-198210000-00005","article-title":"Loss of residual hearing after cochlear implantation.","volume":"99","author":"Boggess","year":"1989","journal-title":"Laryngoscope"},{"key":"R8-20230812","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1016\/j.heares.2014.02.002","article-title":"Insertion site and sealing technique affect residual hearing and tissue formation after cochlear implantation.","volume":"312","author":"Burghard","year":"2014","journal-title":"Hear Res"},{"key":"R9-20230812","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1159\/000091815","article-title":"The effect of methodological differences in the measurement of stapes motion in live and cadaver ears.","volume":"11","author":"Chien","year":"2006","journal-title":"Audiol Neurootol"},{"key":"R10-20230812","doi-asserted-by":"crossref","first-page":"250","DOI":"10.1097\/01.mao.0000244370.47320.9a","article-title":"Measurements of human middle- and inner-ear mechanics with dehiscence of the superior semicircular canal.","volume":"28","author":"Chien","year":"2007","journal-title":"Otol Neurotol"},{"key":"R11-20230812","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1016\/j.heares.2008.11.011","article-title":"Measurements of stapes velocity in live human ears.","volume":"249","author":"Chien","year":"2009","journal-title":"Hear Res"},{"key":"R12-20230812","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1016\/j.heares.2005.03.018","article-title":"Predicting the effect of post-implant cochlear fibrosis on residual hearing.","volume":"205","author":"Choi","year":"2005","journal-title":"Hear Res"},{"key":"R13-20230812","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1044\/2014_AJA-14-0018","article-title":"Conductive component after cochlear implantation in patients with residual hearing conservation.","volume":"23","author":"Chole","year":"2014","journal-title":"Am J Audiol"},{"key":"R14-20230812","doi-asserted-by":"crossref","first-page":"82","DOI":"10.1016\/j.heares.2011.11.008","article-title":"Contribution of complex stapes motion to cochlea activation.","volume":"284","author":"Eiber","year":"2012","journal-title":"Hear Res"},{"key":"R15-20230812","doi-asserted-by":"crossref","first-page":"1109","DOI":"10.3109\/00016489.2014.914245","article-title":"Inner ear energy exposure while drilling a cochleostomy.","volume":"134","author":"Eze","year":"2014","journal-title":"Acta Otolaryngol"},{"key":"R16-20230812","doi-asserted-by":"crossref","first-page":"1726","DOI":"10.1097\/00005537-200310000-00012","article-title":"Combining acoustic and electrical hearing.","volume":"113","author":"Gantz","year":"2003","journal-title":"Laryngoscope"},{"key":"R17-20230812","doi-asserted-by":"crossref","first-page":"796","DOI":"10.1097\/01.MLG.0000157695.07536.D2","article-title":"Preservation of hearing in cochlear implant surgery: advantages of combined electrical and acoustical speech processing.","volume":"115","author":"Gantz","year":"2005","journal-title":"Laryngoscope"},{"key":"R18-20230812","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1159\/000206493","article-title":"Hybrid 10 Clinical Trial.","volume":"14","author":"Gantz","year":"2009","journal-title":"Audiol. Neurotol"},{"key":"R19-20230812","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1097\/MAO.0b013e318241b6d3","article-title":"Spectral and temporal measures in hybrid cochlear implant users: on the mechanism of electroacoustic hearing benefits.","volume":"33","author":"Golub","year":"2012","journal-title":"Otol Neurotol"},{"key":"R20-20230812","first-page":"247","article-title":"Measurement of umbo vibration in human subjects\u2013method and possible clinical applications.","volume":"14","author":"Goode","year":"1993","journal-title":"Am J Otol"},{"key":"R21-20230812","doi-asserted-by":"crossref","first-page":"348","DOI":"10.1080\/00016480410016432","article-title":"Hearing preservation in cochlear implantation for electric acoustic stimulation.","volume":"124","author":"Gstoettner","year":"2004","journal-title":"Acta Otolaryngol"},{"key":"R22-20230812","doi-asserted-by":"crossref","first-page":"968","DOI":"10.1080\/00016480701805471","article-title":"Electric acoustic stimulation of the auditory system: Results of a multi-centre investigation.","volume":"128","author":"Gstoettner","year":"2008","journal-title":"Acta Otolaryngol"},{"key":"R23-20230812","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1159\/000069475","article-title":"Three-dimensional stapes footplate motion in human temporal bones.","volume":"8","author":"Hato","year":"2003","journal-title":"Audiol Neurootol"},{"key":"R24-20230812","first-page":"81","article-title":"A human temporal bone study of stapes footplate movement.","volume":"20","author":"Heiland","year":"1999","journal-title":"Am J Otol"},{"key":"R25-20230812","first-page":"179","article-title":"Conservation of residual hearing with cochlear implantation.","volume":"18","author":"Hodges","year":"1997","journal-title":"Am J Otol"},{"key":"R26-20230812","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1177\/000348940111000106","article-title":"Intraoperative assessment of stapes movement.","volume":"110","author":"Huber","year":"2001","journal-title":"Ann Otol Rhinol Laryngol"},{"key":"R27-20230812","doi-asserted-by":"crossref","first-page":"1187","DOI":"10.1097\/MAO.0b013e31817ef49b","article-title":"The effects of complex stapes motion on the response of the cochlea.","volume":"29","author":"Huber","year":"2008","journal-title":"Otol Neurotol"},{"key":"R28-20230812","doi-asserted-by":"crossref","first-page":"512","DOI":"10.1097\/MAO.0b013e3181ca372b","article-title":"The influence of a cochlear implant electrode on the mechanical function of the inner ear.","volume":"31","author":"Huber","year":"2010","journal-title":"Otol Neurotol"},{"key":"R30-20230812","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1159\/000084023","article-title":"Combined electric and acoustic stimulation of the auditory system: Results of a clinical study.","volume":"10","author":"Kiefer","year":"2005","journal-title":"Audiol Neurootol"},{"key":"R31-20230812","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1016\/j.heares.2006.07.013","article-title":"Representation of acoustic signals in the human cochlea in presence of a cochlear implant electrode.","volume":"221","author":"Kiefer","year":"2006","journal-title":"Hear Res"},{"issue":"Suppl 1","key":"R32-20230812","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1159\/000206492","article-title":"Hearing conservation surgery using the Hybrid-L electrode. Results from the first clinical trial at the Medical University of Hannover.","volume":"14","author":"Lenarz","year":"2009","journal-title":"Audiol Neurootol"},{"key":"R33-20230812","doi-asserted-by":"crossref","first-page":"731","DOI":"10.1177\/000348940711601004","article-title":"Analysis of intracochlear new bone and fibrous tissue formation in human subjects with cochlear implants.","volume":"116","author":"Li","year":"2007","journal-title":"Ann Otol Rhinol Laryngol"},{"key":"R34-20230812","doi-asserted-by":"crossref","first-page":"695","DOI":"10.1016\/j.medengphy.2004.12.009","article-title":"Three-dimensional analysis of electrode behavior in a human cochlear model.","volume":"27","author":"Lim","year":"2005","journal-title":"Med Eng Phys"},{"key":"R35-20230812","doi-asserted-by":"crossref","first-page":"796","DOI":"10.1097\/MAO.0b013e31817fdff8","article-title":"Linearity and lever ratio of the normal and reconstructed cadaveric human middle ear.","volume":"29","author":"Majdalawieh","year":"2008","journal-title":"Otol Neurotol"},{"key":"R36-20230812","doi-asserted-by":"crossref","first-page":"1255","DOI":"10.1097\/MAO.0000000000001171","article-title":"Air-bone gaps contribute to functional hearing preservation in cochlear implantation.","volume":"37","author":"Mattingly","year":"2016","journal-title":"Otol Neurotol"},{"key":"R37-20230812","doi-asserted-by":"crossref","first-page":"1765","DOI":"10.1097\/MAO.0000000000000538","article-title":"Long-term follow-up of hearing preservation in electric-acoustic stimulation patients.","volume":"35","author":"Mertens","year":"2014","journal-title":"Otol Neurotol"},{"key":"R38-20230812","doi-asserted-by":"crossref","first-page":"535","DOI":"10.1097\/MLG.0b013e31802f4169","article-title":"Noise exposure of the inner ear during drilling a cochleostomy for cochlear implantation.","volume":"117","author":"Pau","year":"2007","journal-title":"Laryngoscope"},{"key":"R39-20230812","doi-asserted-by":"crossref","first-page":"2261","DOI":"10.1007\/s00405-014-3184-2","article-title":"Pattern of hearing loss following cochlear implantation.","volume":"272","author":"Raveh","year":"2015","journal-title":"Eur Arch Otorhinolaryngol"},{"key":"R40-20230812","doi-asserted-by":"crossref","first-page":"1325","DOI":"10.1097\/01.mlg.0000167993.05007.35","article-title":"A model for cochlear implant electrode insertion and force evaluation: Results with a new electrode design and insertion technique.","volume":"115","author":"Roland","year":"2005","journal-title":"Laryngoscope"},{"issue":"5 Pt 1","key":"R41-20230812","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1177\/000348949009900515","article-title":"Cadaver middle ears as models for living ears: Comparisons of middle ear input immittance.","volume":"99","author":"Rosowski","year":"1990","journal-title":"Ann Otol Rhinol Laryngol"},{"key":"R42-20230812","doi-asserted-by":"crossref","first-page":"329","DOI":"10.1007\/s10162-010-0207-6","article-title":"Complex stapes motions in human ears.","volume":"11","author":"Sim","year":"2010a","journal-title":"J Assoc Res Otolaryngol"},{"key":"R43-20230812","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1016\/j.heares.2010.08.009","article-title":"Errors in measurement of three-dimensional motions of the stapes using a laser Doppler vibrometer system.","volume":"270","author":"Sim","year":"2010b","journal-title":"Hear Res"},{"key":"R44-20230812","doi-asserted-by":"crossref","first-page":"797","DOI":"10.1121\/1.1639903","article-title":"Fluid volume displacement at the oval and round windows with air and bone conduction stimulation.","volume":"115","author":"Stenfelt","year":"2004a","journal-title":"J Acoust Soc Am"},{"key":"R45-20230812","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1016\/j.heares.2004.07.008","article-title":"Round window membrane motion with air conduction and bone conduction stimulation.","volume":"198","author":"Stenfelt","year":"2004b","journal-title":"Hear Res"},{"key":"R46-20230812","doi-asserted-by":"crossref","first-page":"536","DOI":"10.1111\/j.1749-4486.2008.01822.x","article-title":"Combined electro-acoustic stimulation: A beneficial union?","volume":"33","author":"Talbot","year":"2008","journal-title":"Clin Otolaryngol"},{"key":"R47-20230812","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1177\/000348946207100101","article-title":"Closure of the cochlear windows: Its effect upon air- and bone-conduction.","volume":"71","author":"Tonndorf","year":"1962","journal-title":"Ann Otol Rhinol Laryngol"},{"key":"R48-20230812","doi-asserted-by":"crossref","first-page":"1729","DOI":"10.1121\/1.1687425","article-title":"Speech recognition in noise for cochlear implant listeners: Benefits of residual acoustic hearing.","volume":"115","author":"Turner","year":"2004","journal-title":"J Acoust Soc Am"},{"key":"R49-20230812","doi-asserted-by":"crossref","first-page":"1227","DOI":"10.1097\/MAO.0b013e3181f24005","article-title":"Impact of hair cell preservation in cochlear implantation: Combined electric and acoustic hearing.","volume":"31","author":"Turner","year":"2010","journal-title":"Otol Neurotol"},{"key":"R50-20230812","doi-asserted-by":"crossref","first-page":"334","DOI":"10.1159\/000027695","article-title":"Electric-acoustic stimulation of the auditory system. New technology for severe hearing loss.","volume":"61","author":"von Ilberg","year":"1999","journal-title":"ORL J Otorhinolaryngol Relat Spec"},{"issue":"Suppl 2","key":"R51-20230812","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1159\/000327765","article-title":"Electric-acoustic stimulation of the auditory system: A review of the first decade.","volume":"16","author":"von Ilberg","year":"2011","journal-title":"Audiol Neurootol"},{"key":"R52-20230812","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1016\/S0378-5955(00)00177-5","article-title":"Acoustic responses of the human middle ear.","volume":"150","author":"Voss","year":"2000","journal-title":"Hear Res"},{"key":"R53-20230812","first-page":"125","article-title":"The Hybrid cochlear implant: A review.","volume":"67","author":"Woodson","year":"2010","journal-title":"Adv Otorhinolaryngol"},{"key":"R54-20230812","doi-asserted-by":"crossref","first-page":"943","DOI":"10.3109\/00016489.2014.927591","article-title":"Drill-induced noise level during cochleostomy.","volume":"134","author":"Yu","year":"2014","journal-title":"Acta Otolaryngol"}],"container-title":["Ear &amp; Hearing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00003446-201707000-00016","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,6,22]],"date-time":"2024-06-22T14:41:39Z","timestamp":1719067299000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00003446-201707000-00016"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,7]]},"references-count":52,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2017]]}},"URL":"https:\/\/doi.org\/10.1097\/aud.0000000000000407","relation":{},"ISSN":["0196-0202"],"issn-type":[{"value":"0196-0202","type":"print"}],"subject":[],"published":{"date-parts":[[2017,7]]}}}