{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,18]],"date-time":"2026-06-18T23:31:58Z","timestamp":1781825518651,"version":"3.54.5"},"reference-count":39,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2017,7]]},"abstract":"<jats:sec>\n            <jats:title>Objectives:<\/jats:title>\n            <jats:p>Conductive hearing loss (CHL) systematically alters distortion product otoacoustic emission (DPOAE) levels through attenuation of both the primary tones and the evoked response by the middle ear, as well as through modification of the effective <jats:italic toggle=\"yes\">L<\/jats:italic>\n                                 <jats:sub>1<\/jats:sub>\u2013<jats:italic toggle=\"yes\">L<\/jats:italic>\n                                 <jats:sub>2<\/jats:sub> relationship within the cochlea. It has been postulated that, if optimal primary tone level relationships for an ear without CHL are known or can be estimated accurately and a CHL can be presumed to attenuate both primary tones to a similar extent, the adjustment to <jats:italic toggle=\"yes\">L<\/jats:italic>\n                                 <jats:sub>1<\/jats:sub> required to restore an optimal <jats:italic toggle=\"yes\">L<\/jats:italic>\n                                 <jats:sub>1<\/jats:sub>\u2013<jats:italic toggle=\"yes\">L<\/jats:italic>\n                                 <jats:sub>2<\/jats:sub> separation following CHL induction can be utilized to estimate CHL magnitude objectively. The primary aim of this study was to assess the feasibility of objectively estimating experimentally produced CHL in humans by comparing CHL estimates resulting from DPOAE- and pure-tone audiometry-based methods. A secondary aim was to compare the accuracy of DPOAE-based CHL estimates when obtained using generic, as opposed to ear-specific, optimal primary tone level formula parameters.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Design:<\/jats:title>\n            <jats:p>For a single ear of 30 adults with normal hearing, auditory threshold for a 1\u2009kHz tone was obtained using automated B\u00e9k\u00e9sy audiometry at an ear-canal pressure of 0 daPa, as well as at a negative pressure sufficient for increasing threshold by 3 to 10 dB. The difference in threshold for the ear-canal pressure conditions was defined as the pure-tone audiometry-based estimate of CHL (CHL<jats:sub>PT<\/jats:sub>). For the same two ear-canal pressures, optimal DPOAE primary tone level relationships were identified for <jats:italic toggle=\"yes\">f<\/jats:italic>\n                                 <jats:sub>2<\/jats:sub> = 1\u2009kHz. Specifically, for 20 \u2264 <jats:italic toggle=\"yes\">L<\/jats:italic>\n                                 <jats:sub>2<\/jats:sub> \u2264 70 dB SPL, <jats:italic toggle=\"yes\">L<\/jats:italic>\n                                 <jats:sub>1<\/jats:sub> was varied 15 dB above and below the recommendation of <jats:italic toggle=\"yes\">L<\/jats:italic>\n                                 <jats:sub>1<\/jats:sub> = 0.49 <jats:italic toggle=\"yes\">L<\/jats:italic>\n                                 <jats:sub>2<\/jats:sub> + 41 (dB SPL). The difference between the optimal <jats:italic toggle=\"yes\">L<\/jats:italic>\n                                 <jats:sub>1<\/jats:sub>\u2013<jats:italic toggle=\"yes\">L<\/jats:italic>\n                                 <jats:sub>2<\/jats:sub> relationships for the two pressure conditions was defined as <jats:italic toggle=\"yes\">\u0394L<\/jats:italic>\n                                 <jats:sub>1OPT<\/jats:sub>. A DPOAE-based estimate of CHL (CHL<jats:sub>DP<\/jats:sub>) was obtained using the formula CHL<jats:sub>DP<\/jats:sub> = <jats:italic toggle=\"yes\">\u0394L<\/jats:italic>\n                                 <jats:sub>1OPT<\/jats:sub>\/(1 \u2212 <jats:italic toggle=\"yes\">a<\/jats:italic>), where <jats:italic toggle=\"yes\">a<\/jats:italic> represents the slope of the optimal <jats:italic toggle=\"yes\">L<\/jats:italic>\n                                 <jats:sub>1<\/jats:sub>\u2013<jats:italic toggle=\"yes\">L<\/jats:italic>\n                                 <jats:sub>2<\/jats:sub> relationship observed in the absence of CHL.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>A highly significant linear dependence was identified between pure-tone audiometry- and DPOAE-based estimates of CHL, <jats:italic toggle=\"yes\">r<\/jats:italic>(19) = 0.71, <jats:italic toggle=\"yes\">p<\/jats:italic> &lt; 0.001. However, the correlation was only significant when ear-specific optimization formula parameters were known. Use of generic, frequency-nonspecific parameters resulted in significantly less accurate estimates than did either ear-specific (<jats:italic toggle=\"yes\">p<\/jats:italic> &lt; 0.001) or generic, frequency-specific parameters (<jats:italic toggle=\"yes\">p<\/jats:italic> = 0.007).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>This study provides empirical support for a theory of how CHL, through a combination of middle ear filtering and alteration of effective primary tone level relationships within the cochlea, systematically affects DPOAE amplitude. Although CHL<jats:sub>DP<\/jats:sub> was shown to be significantly predictive of CHL<jats:sub>PT<\/jats:sub> when optimization formula parameters for a given ear, both with and without mild CHL, were known, the lack of a meaningful relationship when using generic primary tone level formula parameters significantly limits the method\u2019s potential for clinical utility.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/aud.0000000000000415","type":"journal-article","created":{"date-parts":[[2017,2,17]],"date-time":"2017-02-17T00:08:46Z","timestamp":1487290126000},"page":"391-398","source":"Crossref","is-referenced-by-count":9,"title":["Estimation of Minor Conductive Hearing Loss in Humans Using Distortion Product Otoacoustic Emissions"],"prefix":"10.1097","volume":"38","author":[{"given":"Steven C.","family":"Marcrum","sequence":"first","affiliation":[{"name":"Department of Electrical Engineering and Information Technology, Technical University of Munich, Munich, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"Kummer","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering and Information Technology, Technical University of Munich, Munich, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas","family":"Steffens","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering and Information Technology, Technical University of Munich, Munich, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R2-20230812","doi-asserted-by":"crossref","first-page":"1810","DOI":"10.1121\/1.1460923","article-title":"Pure-tone threshold estimation from extrapolated distortion product otoacoustic emission I\/O-functions in normal and cochlear hearing loss ears.","volume":"111","author":"Boege","year":"2002","journal-title":"J Acoust Soc Am"},{"key":"R3-20230812","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1111\/j.1365-2273.1989.tb00346.x","article-title":"Conductive hearing loss assessment in children with otitis media with effusion. A comparison of pure tone and BERA results.","volume":"14","author":"Conijn","year":"1989","journal-title":"Clin Otolaryngol Allied Sci"},{"key":"R4-20230812","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1288\/00005537-197701000-00011","article-title":"The significance of negative middle ear pressure.","volume":"87","author":"Cooper","year":"1977","journal-title":"Laryngoscope"},{"key":"R5-20230812","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1097\/AUD.0b013e31826709c3","article-title":"Influence of the individual DPOAE growth behavior on DPOAE level variations caused by conductive hearing loss and elevated intracranial pressure.","volume":"34","author":"Deppe","year":"2013","journal-title":"Ear Hear"},{"key":"R6-20230812","doi-asserted-by":"crossref","first-page":"887","DOI":"10.1002\/lary.23182","article-title":"Wideband acoustic transfer functions predict middle-ear effusion.","volume":"122","author":"Ellison","year":"2012","journal-title":"Laryngoscope"},{"key":"R7-20230812","doi-asserted-by":"crossref","first-page":"462","DOI":"10.3766\/jaaa.25.5.5","article-title":"Effects of ear-canal static pressure on pure-tone thresholds and wideband acoustic immittance.","volume":"25","author":"Feeney","year":"2014","journal-title":"J Am Acad Audiol"},{"key":"R8-20230812","doi-asserted-by":"crossref","first-page":"821","DOI":"10.1121\/1.399732","article-title":"The behavior of the acoustic distortion product, 2f1-f2, from the human ear and its relation to auditory sensitivity.","volume":"88","author":"Gaskill","year":"1990","journal-title":"J Acoust Soc Am"},{"key":"R9-20230812","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1016\/j.heares.2004.03.018","article-title":"Middle ear and cochlear disorders result in different DPOAE growth behaviour: Implications for the differentiation of sound conductive and cochlear hearing loss.","volume":"193","author":"Gehr","year":"2004","journal-title":"Hear Res"},{"key":"R10-20230812","doi-asserted-by":"crossref","first-page":"783","DOI":"10.1121\/1.393953","article-title":"Acoustics of ear canal measurement of eardrum SPL in simulators.","volume":"80","author":"Gilman","year":"1986","journal-title":"J Acoust Soc Am"},{"key":"R11-20230812","doi-asserted-by":"crossref","first-page":"440","DOI":"10.1097\/00003446-199712000-00003","article-title":"From laboratory to clinic: A large scale study of distortion product otoacoustic emissions in ears with normal hearing and ears with hearing loss.","volume":"18","author":"Gorga","year":"1997","journal-title":"Ear Hear"},{"key":"R12-20230812","doi-asserted-by":"crossref","first-page":"3275","DOI":"10.1121\/1.1570433","article-title":"Further efforts to predict pure-tone thresholds from distortion product otoacoustic emission input\/output functions.","volume":"113","author":"Gorga","year":"2003","journal-title":"J Acoust Soc Am"},{"key":"R14-20230812","doi-asserted-by":"crossref","first-page":"1058","DOI":"10.1097\/MAO.0b013e318282964f","article-title":"A review of the effectiveness of otoacoustic emissions for evaluating hearing status after newborn screening.","volume":"34","author":"Janssen","year":"2013","journal-title":"Otol Neurotol"},{"key":"R15-20230812","doi-asserted-by":"crossref","first-page":"2969","DOI":"10.1121\/1.1853101","article-title":"Distortion product otoacoustic emissions for hearing threshold estimation and differentiation between middle-ear and cochlear disorders in neonates.","volume":"117","author":"Janssen","year":"2005","journal-title":"J Acoust Soc Am"},{"key":"R16-20230812","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1016\/S0378-5955(02)00330-1","article-title":"DPOAEs in young normal-hearing subjects with histories of otitis media: Evidence of sub-clinical impairments.","volume":"167","author":"Job","year":"2002","journal-title":"Hear Res"},{"key":"R17-20230812","doi-asserted-by":"crossref","first-page":"418","DOI":"10.1121\/1.2133714","article-title":"Influence of primary-level and primary-frequency ratios on human distortion product otoacoustic emissions.","volume":"119","author":"Johnson","year":"2006","journal-title":"J Acoust Soc Am"},{"key":"R18-20230812","doi-asserted-by":"crossref","first-page":"3539","DOI":"10.1121\/1.2799474","article-title":"Distortion product otoacoustic emissions: Cochlear-source contributions and clinical test performance.","volume":"122","author":"Johnson","year":"2007","journal-title":"J Acoust Soc Am"},{"key":"R19-20230812","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1097\/AUD.0b013e3181b71924","article-title":"Clinical test performance of distortion-product otoacoustic emissions using new stimulus conditions.","volume":"31","author":"Johnson","year":"2010","journal-title":"Ear Hear"},{"key":"R20-20230812","doi-asserted-by":"crossref","first-page":"978","DOI":"10.1121\/1.2427128","article-title":"Theory of forward and reverse middle-ear transmission applied to otoacoustic emissions in infant and adult ears.","volume":"121","author":"Keefe","year":"2007","journal-title":"J Acoust Soc Am"},{"key":"R21-20230812","doi-asserted-by":"crossref","first-page":"880","DOI":"10.3109\/14992027.2012.721936","article-title":"Wideband aural acoustic absorbance predicts conductive hearing loss in children.","volume":"51","author":"Keefe","year":"2012","journal-title":"Int J Audiol"},{"key":"R22-20230812","doi-asserted-by":"crossref","first-page":"230","DOI":"10.1097\/AUD.0b013e3181fa5da2","article-title":"Do \u201coptimal\u201d conditions improve distortion product otoacoustic emission test performance?","volume":"32","author":"Kirby","year":"2011","journal-title":"Ear Hear"},{"issue":"Suppl 1","key":"R23-20230812","doi-asserted-by":"crossref","first-page":"S51","DOI":"10.3109\/14992027.2011.635713","article-title":"Multivariate DPOAE metrics for identifying changes in hearing: perspectives from ototoxicity monitoring.","volume":"51","author":"Konrad-Martin","year":"2012","journal-title":"Int J Audiol"},{"key":"R24-20230812","doi-asserted-by":"crossref","first-page":"3431","DOI":"10.1121\/1.423054","article-title":"The level and growth behavior of the 2 f1-f2 distortion product otoacoustic emission and its relationship to auditory sensitivity in normal hearing and cochlear hearing loss.","volume":"103","author":"Kummer","year":"1998","journal-title":"J Acoust Soc Am"},{"key":"R25-20230812","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1007\/s00106-005-1341-z","article-title":"The influence of conductive hearing loss on DPOAE-threshold. The effect of an individually optimized stimulation.","volume":"54","author":"Kummer","year":"2006","journal-title":"HNO"},{"key":"R26-20230812","doi-asserted-by":"crossref","first-page":"117","DOI":"10.3109\/01050397909076310","article-title":"The correlation between negative middle ear pressure and the corresponding conductive hearing loss in children. A 12-month study of 352 unselected 7-year-old children.","volume":"8","author":"Lildholdt","year":"1979","journal-title":"Scand Audiol"},{"key":"R27-20230812","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1044\/1059-0889.0302.52","article-title":"Auditory brainstem response wave I prediction of conductive component in infants and young children.","volume":"3","author":"Mackersie","year":"1994","journal-title":"Am J Audiol"},{"key":"R28-20230812","doi-asserted-by":"crossref","first-page":"325","DOI":"10.3109\/14992027.2016.1143979","article-title":"Average optimal DPOAE primary tone levels in normal-hearing adults.","volume":"55","author":"Marcrum","year":"2016","journal-title":"Int J Audiol"},{"key":"R29-20230812","first-page":"454","article-title":"Distortion product otoacoustic emissions: Hit and false-positive rates in normal-hearing and hearing-impaired subjects.","volume":"18","author":"Musiek","year":"1997","journal-title":"Am J Otol"},{"issue":"3 Pt 1","key":"R30-20230812","doi-asserted-by":"crossref","first-page":"1248","DOI":"10.1121\/1.1853253","article-title":"Distortion-product otoacoustic emission measured with continuously varying stimulus level.","volume":"117","author":"Neely","year":"2005","journal-title":"J Acoust Soc Am"},{"key":"R31-20230812","doi-asserted-by":"crossref","first-page":"9529","DOI":"10.1073\/pnas.1201592109","article-title":"Noninvasive in vivo optical detection of biofilm in the human middle ear.","volume":"109","author":"Nguyen","year":"2012","journal-title":"Proc Natl Acad Sci U S A"},{"key":"R32-20230812","doi-asserted-by":"crossref","first-page":"1845","DOI":"10.1121\/1.3474898","article-title":"Quantitative estimation of minor conductive hearing loss with distortion product otoacoustic emissions in the guinea pig.","volume":"128","author":"Olzowy","year":"2010","journal-title":"J Acoust Soc Am"},{"key":"R33-20230812","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1078\/0939-3889-00148","article-title":"Weighted DPOAE input\/output-functions: a tool for automatic assessment of hearing loss in clinical application.","volume":"13","author":"Oswald","year":"2003","journal-title":"Z Med Phys"},{"issue":"Suppl 1","key":"R34-20230812","doi-asserted-by":"crossref","first-page":"54S","DOI":"10.1097\/AUD.0b013e31829c9670","article-title":"Prediction of conductive hearing loss using wideband acoustic immittance.","volume":"34","author":"Prieve","year":"2013","journal-title":"Ear Hear"},{"key":"R35-20230812","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1097\/AUD.0b013e3181e8b6a7","article-title":"Distortion-product otoacoustic emission test performance for ototoxicity monitoring.","volume":"32","author":"Reavis","year":"2011","journal-title":"Ear Hear"},{"key":"R36-20230812","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1044\/1059-0889(1998\/014)","article-title":"Tympanometric screening norms for adults.","volume":"7","author":"Roup","year":"1998","journal-title":"Am J Audiol"},{"key":"R37-20230812","doi-asserted-by":"crossref","first-page":"288","DOI":"10.1121\/1.2931953","article-title":"Influence of in situ, sound-level calibration on distortion-product otoacoustic emission variability.","volume":"124","author":"Scheperle","year":"2008","journal-title":"J Acoust Soc Am"},{"key":"R38-20230812","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1016\/0378-5955(94)90106-6","article-title":"Sound calibration and distortion product otoacoustic emissions at high frequencies.","volume":"80","author":"Siegel","year":"1994","journal-title":"Hear Res"},{"key":"R39-20230812","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1097\/AUD.0b013e3182280326","article-title":"Ear canal pressure variations versus negative middle ear pressure: Comparison using distortion product otoacoustic emission measurement in humans.","volume":"33","author":"Sun","year":"2012","journal-title":"Ear Hear"},{"key":"R40-20230812","doi-asserted-by":"crossref","first-page":"2346","DOI":"10.1121\/1.411959","article-title":"Dependence of distortion-product otoacoustic emissions on primary levels in normal and impaired ears. I. Effects of decreasing L2 below L1.","volume":"97","author":"Whitehead","year":"1995a","journal-title":"J Acoust Soc Am"},{"key":"R41-20230812","doi-asserted-by":"crossref","first-page":"2359","DOI":"10.1121\/1.411960","article-title":"Dependence of distortion-product otoacoustic emissions on primary levels in normal and impaired ears. II. Asymmetry in L1, L2 space.","volume":"97","author":"Whitehead","year":"1995b","journal-title":"J Acoust Soc Am"}],"container-title":["Ear &amp; Hearing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00003446-201707000-00001","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,12]],"date-time":"2023-08-12T08:02:44Z","timestamp":1691827364000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00003446-201707000-00001"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,7]]},"references-count":39,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2017]]}},"URL":"https:\/\/doi.org\/10.1097\/aud.0000000000000415","relation":{},"ISSN":["0196-0202"],"issn-type":[{"value":"0196-0202","type":"print"}],"subject":[],"published":{"date-parts":[[2017,7]]}}}