{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T02:12:40Z","timestamp":1790734360021,"version":"4.1.0"},"reference-count":35,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2017,11]]},"abstract":"<jats:sec>\n            <jats:title>Objectives:<\/jats:title>\n            <jats:p>The auditory brainstem implant (ABI) provides sound awareness to patients who are ineligible for cochlear implantation. Auditory performance varies widely among similar ABI cohorts. We hypothesize that differences in electrode array position contribute to this variance. Herein, we classify ABI array position based on postoperative imaging and investigate the relationship between position and perception.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Design:<\/jats:title>\n            <jats:p>Retrospective review of pediatric and adult ABI users with postoperative computed tomography. To standardize views across subjects, true axial reformatted series of scans were created using the McRae line. Using multiplanar reconstructions, basion and electrode array tip coordinates and array angles from vertical were measured. From a lateral view, array angles (V) were classified into types I to IV, and from posterior view, array angles (T) were classified into types A to D. Array position was further categorized by measuring distance vertical from basion (D1) and lateral from midline (D2). Differences between array classifications were compared with audiometric thresholds, number of active electrodes, and pitch ranking.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Pediatric (n = 4, 2 with revisions) and adult (n = 7) ABI subjects were included in this study. Subjects had a wide variety of ABI array angles, but most were aimed superiorly and posteriorly (type II, n = 7) from lateral view and upright or medially tilted from posterior view (type A, n = 6). Mean pediatric distances were 8 to 42% smaller than adults for D1 and D2. In subjects with perceptual data, electrical thresholds and the number of active electrodes differed among classification types.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>In this first study to classify ABI electrode array orientation, array position varied widely. This variability may explain differences in auditory performance.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/aud.0000000000000448","type":"journal-article","created":{"date-parts":[[2017,7,12]],"date-time":"2017-07-12T19:09:57Z","timestamp":1499886597000},"page":"e343-e351","source":"Crossref","is-referenced-by-count":32,"title":["Auditory Brainstem Implant Array Position Varies Widely Among Adult and Pediatric Patients and Is Associated With Perception"],"prefix":"10.1097","volume":"38","author":[{"given":"Samuel R.","family":"Barber","sequence":"first","affiliation":[{"name":"Department of Radiology, Massachusetts Eye and Ear Infirmary, Boston, MA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elliott D.","family":"Kozin","sequence":"additional","affiliation":[{"name":"Department of Radiology, Massachusetts Eye and Ear Infirmary, Boston, MA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aaron K.","family":"Remenschneider","sequence":"additional","affiliation":[{"name":"Department of Radiology, Massachusetts Eye and Ear Infirmary, Boston, MA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sidharth V.","family":"Puram","sequence":"additional","affiliation":[{"name":"Department of Radiology, Massachusetts Eye and Ear Infirmary, Boston, MA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Max","family":"Smith","sequence":"additional","affiliation":[{"name":"Department of Radiology, Massachusetts Eye and Ear Infirmary, Boston, MA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Barbara S.","family":"Herrmann","sequence":"additional","affiliation":[{"name":"Department of Radiology, Massachusetts Eye and Ear Infirmary, Boston, MA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mary E.","family":"Cunnane","sequence":"additional","affiliation":[{"name":"Department of Radiology, Massachusetts Eye and Ear Infirmary, Boston, MA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M. Christian","family":"Brown","sequence":"additional","affiliation":[{"name":"Department of Radiology, Massachusetts Eye and Ear Infirmary, Boston, MA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel J.","family":"Lee","sequence":"additional","affiliation":[{"name":"Department of Radiology, Massachusetts Eye and Ear Infirmary, Boston, MA."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230726","doi-asserted-by":"crossref","first-page":"908","DOI":"10.3109\/00016489.2011.570786","article-title":"Hearing improvement after cochlear implantation in common cavity malformed cochleae: Long-term follow-up results.","volume":"131","author":"Ahn","year":"2011","journal-title":"Acta Otolaryngol"},{"key":"R2-20230726","doi-asserted-by":"crossref","first-page":"1069","DOI":"10.1007\/s00276-015-1477-9","article-title":"Sex differences in adult craniofacial parameters.","volume":"37","author":"Avci","year":"2015","journal-title":"Surg Radiol Anat"},{"key":"R3-20230726","doi-asserted-by":"crossref","first-page":"1844","DOI":"10.1097\/MAO.0000000000000584","article-title":"New outcomes with auditory brainstem implants in NF2 patients.","volume":"35","author":"Behr","year":"2014","journal-title":"Otol Neurotol"},{"key":"R4-20230726","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1097\/MAO.0b013e31818d1cd2","article-title":"Real-time intraoperative computed tomography to assist cochlear implant placement in the malformed inner ear.","volume":"30","author":"Bloom","year":"2009","journal-title":"Otol Neurotol"},{"key":"R5-20230726","doi-asserted-by":"crossref","first-page":"301","DOI":"10.3171\/2013.4.JNS122324","article-title":"Accuracy of deep brain stimulation electrode placement using intraoperative computed tomography without microelectrode recording.","volume":"119","author":"Burchiel","year":"2013","journal-title":"J Neurosurg"},{"key":"R6-20230726","first-page":"167","article-title":"Auditory outcomes in tumor vs. nontumor patients fitted with auditory brainstem implants.","volume":"64","author":"Colletti","year":"2006","journal-title":"Adv Otorhinolaryngol"},{"key":"R7-20230726","doi-asserted-by":"crossref","first-page":"1974","DOI":"10.1097\/01.mlg.0000178327.42926.ec","article-title":"Open set speech perception with auditory brainstem implant?","volume":"115","author":"Colletti","year":"2005","journal-title":"Laryngoscope"},{"key":"R8-20230726","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1016\/j.otohns.2005.03.022","article-title":"Auditory brainstem implant (ABI): New frontiers in adults and children.","volume":"133","author":"Colletti","year":"2005","journal-title":"Otolaryngol Head Neck Surg"},{"key":"R9-20230726","doi-asserted-by":"crossref","first-page":"386","DOI":"10.1159\/000363684","article-title":"The development of auditory perception in children after auditory brainstem implantation.","volume":"19","author":"Colletti","year":"2014","journal-title":"Audiol Neurootol"},{"key":"R10-20230726","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1016\/j.crad.2008.03.012","article-title":"CT evaluation of Chamberlain\u2019s, McGregor\u2019s, and McRae\u2019s skull-base lines.","volume":"64","author":"Cronin","year":"2009","journal-title":"Clin Radiol"},{"key":"R11-20230726","doi-asserted-by":"crossref","first-page":"1666","DOI":"10.1097\/MAO.0b013e3182a09cc3","article-title":"Value of routine plain x-ray position checks after cochlear implantation.","volume":"34","author":"Dirr","year":"2013","journal-title":"Otol Neurotol"},{"key":"R12-20230726","doi-asserted-by":"crossref","first-page":"368","DOI":"10.1097\/AUD.0000000000000126","article-title":"Auditory brainstem implant: Electrophysiologic responses and subject perception.","volume":"36","author":"Herrmann","year":"2015","journal-title":"Ear Hear"},{"key":"R13-20230726","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1177\/019459988409200111","article-title":"Cochlear nucleus implants.","volume":"92","author":"Hitselberger","year":"1984","journal-title":"Otolaryngol Head Neck Surg"},{"key":"R14-20230726","doi-asserted-by":"crossref","first-page":"486","DOI":"10.1007\/s10278-012-9458-6","article-title":"Accuracy and reliability of length measurements on three-dimensional computed tomography using open-source OsiriX software.","volume":"25","author":"Kim","year":"2012","journal-title":"J Digit Imaging"},{"issue":"Suppl 2)","key":"R15-20230726","first-page":"306","article-title":"Auditory brainstem implantation: Anatomy and approaches.","volume":"11","author":"Komune","year":"2015","journal-title":"Neurosurgery"},{"key":"R16-20230726","doi-asserted-by":"crossref","first-page":"116","DOI":"10.3109\/00016489.2011.626794","article-title":"Evaluation of the implanted cochlear implant electrode by CT scanning with three-dimensional reconstruction.","volume":"132","author":"Kong","year":"2012","journal-title":"Acta Otolaryngol"},{"key":"R17-20230726","doi-asserted-by":"crossref","first-page":"W421","DOI":"10.2214\/AJR.10.5339","article-title":"Craniometric measurements in the assessment of craniovertebral settling: Are they still relevant in the age of cross-sectional imaging?","volume":"196","author":"Kwong","year":"2011","journal-title":"AJR Am J Roentgenol"},{"key":"R18-20230726","doi-asserted-by":"crossref","first-page":"138","DOI":"10.3171\/2015.1.PEDS14475","article-title":"Posterior odontoid process angulation in pediatric Chiari I malformation: An MRI morphometric external validation study.","volume":"16","author":"Ladner","year":"2015","journal-title":"J Neurosurg Pediatr"},{"key":"R19-20230726","first-page":"599","article-title":"A simple CT method for location of auditory brain stem implant electrodes.","volume":"16","author":"Lo","year":"1995","journal-title":"AJNR Am J Neuroradiol"},{"key":"R20-20230726","first-page":"23","article-title":"Occipitalization of the atlas.","volume":"70","author":"Mcrae","year":"1953","journal-title":"Am J Roentgenol Radium Ther Nucl Med"},{"key":"R21-20230726","doi-asserted-by":"crossref","first-page":"873","DOI":"10.1097\/MAO.0000000000000671","article-title":"Subjective outcomes of auditory brainstem implantation.","volume":"36","author":"McSorley","year":"2015","journal-title":"Otol Neurotol"},{"key":"R22-20230726","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1001\/archfaci.2012.510","article-title":"A novel technique for malar eminence evaluation using 3-dimensional computed tomography.","volume":"14","author":"Moubayed","year":"2012","journal-title":"Arch Facial Plast Surg"},{"key":"R23-20230726","doi-asserted-by":"crossref","first-page":"739","DOI":"10.1177\/0194599815596929","article-title":"Systematic review of nontumor pediatric auditory brainstem implant outcomes.","volume":"153","author":"Noij","year":"2015","journal-title":"Otolaryngol Head Neck Surg"},{"key":"R24-20230726","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1177\/0194599816637599","article-title":"Outcomes following pediatric auditory brainstem implant surgery: Early experiences in a North American Center.","volume":"155","author":"Puram","year":"2016","journal-title":"Otolaryngol Head Neck Surg"},{"key":"R25-20230726","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1007\/s10278-004-1014-6","article-title":"OsiriX: An open-source software for navigating in multidimensional DICOM images.","volume":"17","author":"Rosset","year":"2004","journal-title":"J Digit Imaging"},{"key":"R26-20230726","doi-asserted-by":"crossref","first-page":"2230","DOI":"10.1097\/00005537-200212000-00019","article-title":"A new classification for cochleovestibular malformations.","volume":"112","author":"Sennaroglu","year":"2002","journal-title":"Laryngoscope"},{"key":"R27-20230726","doi-asserted-by":"crossref","first-page":"634","DOI":"10.1177\/019459989310800603","article-title":"Auditory brainstem implant: II. Postsurgical issues and performance.","volume":"108","author":"Shannon","year":"1993","journal-title":"Otolaryngol Head Neck Surg"},{"key":"R28-20230726","doi-asserted-by":"crossref","first-page":"1486","DOI":"10.1097\/MAO.0000000000000852","article-title":"Measurement of cochlear implant electrode position from intraoperative post-insertion skull radiographs: A validation study.","volume":"36","author":"Svrakic","year":"2015","journal-title":"Otol Neurotol"},{"key":"R29-20230726","doi-asserted-by":"crossref","first-page":"1981","DOI":"10.1002\/ar.22588","article-title":"Auditory brainstem implants: how do they work?","volume":"295","author":"Vincent","year":"2012","journal-title":"Anat Rec (Hoboken)"},{"key":"R30-20230726","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1016\/j.otot.2005.04.004","article-title":"Auditory brainstem implantation.","volume":"16","author":"Wackym","year":"2005","journal-title":"Oper Tech Otolaryngol Head Neck Surg"},{"key":"R31-20230726","doi-asserted-by":"crossref","first-page":"338","DOI":"10.1016\/0168-5597(95)00022-K","article-title":"Auditory brain-stem responses evoked by electrical stimulation of the cochlear nucleus in human subjects.","volume":"96","author":"Waring","year":"1995","journal-title":"Electroencephalogr Clin Neurophysiol"},{"key":"R32-20230726","doi-asserted-by":"crossref","first-page":"538","DOI":"10.1016\/S0168-5597(96)96061-X","article-title":"Properties of auditory brainstem responses evoked by intra-operative electrical stimulation of the cochlear nucleus in human subjects.","volume":"100","author":"Waring","year":"1996","journal-title":"Electroencephalogr Clin Neurophysiol"},{"key":"R33-20230726","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1016\/S0378-5955(99)00016-7","article-title":"Activating separate ascending auditory pathways produces different human thalamic\/cortical responses.","volume":"130","author":"Waring","year":"1999","journal-title":"Hear Res"},{"key":"R34-20230726","doi-asserted-by":"crossref","first-page":"110","DOI":"10.5152\/iao.2015.915","article-title":"Recent rehabilitation experience with pediatric abi users.","volume":"11","author":"Y\u00fccel","year":"2015","journal-title":"J Int Adv Otol"},{"key":"R35-20230726","doi-asserted-by":"crossref","first-page":"138","DOI":"10.1111\/j.1741-4520.2011.00322.x","article-title":"Morphological and morphometric study on sphenoid and basioccipital ossification in normal human fetuses.","volume":"51","author":"Zhang","year":"2011","journal-title":"Congenit Anom (Kyoto)"}],"container-title":["Ear &amp; Hearing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00003446-201711000-00018","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,7,26]],"date-time":"2023-07-26T08:09:05Z","timestamp":1690358945000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00003446-201711000-00018"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,11]]},"references-count":35,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2017]]}},"URL":"https:\/\/doi.org\/10.1097\/aud.0000000000000448","relation":{},"ISSN":["0196-0202"],"issn-type":[{"value":"0196-0202","type":"print"}],"subject":[],"published":{"date-parts":[[2017,11]]}}}