{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,25]],"date-time":"2026-03-25T12:38:46Z","timestamp":1774442326561,"version":"3.50.1"},"reference-count":39,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","license":[{"start":{"date-parts":[[2019,1,1]],"date-time":"2019-01-01T00:00:00Z","timestamp":1546300800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019,1]]},"abstract":"<jats:sec>\n            <jats:title>Objectives:<\/jats:title>\n            <jats:p>The primary aim was to identify the proportion of individuals within the adult cochlear implant population who are aware of tinnitus and those who report a negative impact from this perception, using a bespoke questionnaire designed to limit bias. A secondary aim was to use qualitative analysis of open-text responses to identify themes linked to tinnitus perception in this population.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Design:<\/jats:title>\n            <jats:p>A cross-sectional questionnaire study of a large clinical population who received an implant from Cambridge University Hospitals, United Kingdom.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Seventy-five percent of respondents reported tinnitus awareness. When impact scores for six areas of difficulty were ranked, 13% of individuals ranked tinnitus their primary concern and nearly a third ranked tinnitus in the top two positions. Tinnitus impact was not found to reduce with duration since implantation. The most common open-text responses were linked to a general improvement postimplantation and acute tinnitus alleviation specific to times when the device was in use.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>Tinnitus is a problem for a significant proportion of individuals with a cochlear implant. Clinicians, scientists, and cochlear implant manufacturers should be aware that management of tinnitus may be a greater priority for an implantee than difficulties linked to speech perception. Where a positive effect of implantation was reported, there was greater evidence for masking of tinnitus via the implant rather than reversal of maladaptive plasticity.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/aud.0000000000000601","type":"journal-article","created":{"date-parts":[[2018,6,23]],"date-time":"2018-06-23T00:09:33Z","timestamp":1529712573000},"page":"135-142","source":"Crossref","is-referenced-by-count":12,"title":["A Cross-Sectional Questionnaire Study of Tinnitus Awareness and Impact in a Population of Adult Cochlear Implant Users"],"prefix":"10.1097","volume":"40","author":[{"given":"Philip A.","family":"Gomersall","sequence":"first","affiliation":[{"name":"MRC Cognition & Brain Sciences Unit, University of Cambridge, United Kingdom"},{"name":"Cambridge University Hospitals NHS Foundation Trust, Cambridge, United Kingdom"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David M.","family":"Baguley","sequence":"additional","affiliation":[{"name":"National Institute for Health Research\u2014Nottingham Hearing Biomedical Research Unit, Nottingham, United Kingdom"},{"name":"Otology and Hearing, Division of Clinical Neuroscience, School of Medicine, University of Nottingham, Nottingham, United Kingdom."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robert P.","family":"Carlyon","sequence":"additional","affiliation":[{"name":"MRC Cognition & Brain Sciences Unit, University of Cambridge, United Kingdom"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20230726","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1044\/1059-0889(2012\/12-0010)","article-title":"Psychometric evaluation of visual analog scale for the assessment of chronic tinnitus.","volume":"21","author":"Adamchic","year":"2012","journal-title":"Am J Audiol"},{"key":"R2-20230726","doi-asserted-by":"crossref","first-page":"315","DOI":"10.3766\/jaaa.20.5.5","article-title":"Tinnitus distress, anxiety, depression, and hearing problems among cochlear implant patients with tinnitus.","volume":"20","author":"Andersson","year":"2009","journal-title":"J Am Acad Audiol"},{"key":"R3-20230726","doi-asserted-by":"crossref","first-page":"53","DOI":"10.3109\/03005368909077819","article-title":"Tinnitus\u2014a study of its prevalence and characteristics.","volume":"23","author":"Axelsson","year":"1989","journal-title":"Br J Audiol"},{"key":"R4-20230726","doi-asserted-by":"crossref","first-page":"1600","DOI":"10.1016\/S0140-6736(13)60142-7","article-title":"Tinnitus.","volume":"382","author":"Baguley","year":"2013","journal-title":"Lancet"},{"key":"R5-20230726","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1016\/S0079-6123(07)66033-6","article-title":"Cochlear implants and tinnitus.","volume":"166","author":"Baguley","year":"2007","journal-title":"Prog Brain Res"},{"key":"R6-20230726","doi-asserted-by":"crossref","first-page":"108","DOI":"10.3109\/03005367909078884","article-title":"The BKB (Bamford-Kowal-Bench) sentence lists for partially-hearing children.","volume":"13","author":"Bench","year":"1979","journal-title":"Br J Audiol"},{"key":"R8-20230726","doi-asserted-by":"crossref","first-page":"1469","DOI":"10.1121\/1.3291981","article-title":"The upper limit of temporal pitch for cochlear-implant listeners: Stimulus duration, conditioner pulses, and the number of electrodes stimulated.","volume":"127","author":"Carlyon","year":"2010","journal-title":"J Acoust Soc Am"},{"key":"R9-20230726","doi-asserted-by":"crossref","first-page":"676","DOI":"10.1016\/j.tins.2004.08.010","article-title":"The neuroscience of tinnitus.","volume":"27","author":"Eggermont","year":"2004","journal-title":"Trends Neurosci"},{"key":"R10-20230726","first-page":"147","article-title":"Descriptive and interpretive approaches to qualitative research.","author":"Elliott","year":"2005","journal-title":"In A Handbook of Research Methods for Clinical and Health Psychology"},{"key":"R11-20230726","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1055\/s-0042-1748460","article-title":"Glasgow hearing aid benefit profile: derivation and validation of a client-centered outcome measure for hearing aid services.","volume":"10","author":"Gatehouse","year":"1999","journal-title":"J Am Acad Audiol"},{"key":"R12-20230726","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1177\/1745691610393521","article-title":"Is it all relative? Comparative judgments and the possible improvement of self-ratings and ratings of others.","volume":"6","author":"Goffin","year":"2011","journal-title":"Perspect Psychol Sci"},{"key":"R13-20230726","doi-asserted-by":"crossref","first-page":"263","DOI":"10.3109\/01050399609074965","article-title":"Correlates of sleep disturbance in chronic distressing tinnitus.","volume":"25","author":"Hallam","year":"1996","journal-title":"Scand Audiol"},{"key":"R14-20230726","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1179\/1754762811Y.0000000035","article-title":"Development of the A\u00a7E test battery for assessment of pitch perception in speech.","volume":"13","author":"Heeren","year":"2012","journal-title":"Cochlear Implants Int"},{"key":"R15-20230726","doi-asserted-by":"crossref","first-page":"1204","DOI":"10.1044\/1092-4388(2005\/084)","article-title":"General review of tinnitus: Prevalence, mechanisms, effects, and management.","volume":"48","author":"Henry","year":"2005","journal-title":"J Speech Lang Hear Res"},{"issue":"12","key":"R16-20230726","first-page":"CD006371","article-title":"Sound therapy (masking) in the management of tinnitus in adults.","author":"Hobson","year":"2010","journal-title":"Cochrane Database Syst Rev"},{"key":"R17-20230726","doi-asserted-by":"crossref","first-page":"7","DOI":"10.3109\/03005369309077884","article-title":"A neurophysiological approach to tinnitus: clinical implications.","volume":"27","author":"Jastreboff","year":"1993","journal-title":"Br J Audiol"},{"key":"R18-20230726","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1016\/j.heares.2010.12.003","article-title":"Tinnitus: Models and mechanisms.","volume":"276","author":"Kaltenbach","year":"2011","journal-title":"Hear Res"},{"key":"R19-20230726","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1159\/000306630","article-title":"Epidemiological study of chronic tinnitus in Assiut, Egypt.","volume":"35","author":"Khedr","year":"2010","journal-title":"Neuroepidemiology"},{"key":"R20-20230726","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1016\/j.otohns.2007.09.023","article-title":"Influence of silence and attention on tinnitus perception.","volume":"138","author":"Knobel","year":"2008","journal-title":"Otolaryngol Head Neck Surg"},{"issue":"Pt B","key":"R21-20230726","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1016\/j.heares.2015.02.009","article-title":"Synaptopathy in the noise-exposed and aging cochlea: Primary neural degeneration in acquired sensorineural hearing loss.","volume":"330","author":"Kujawa","year":"2015","journal-title":"Hear Res"},{"key":"R22-20230726","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1016\/j.heares.2013.04.009","article-title":"Technological, biological, and acoustical constraints to music perception in cochlear implant users.","volume":"308","author":"Limb","year":"2014","journal-title":"Hear Res"},{"key":"R24-20230726","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1097\/AUD.0b013e31822f67c0","article-title":"The tinnitus functional index: development of a new clinical measure for chronic, intrusive tinnitus.","volume":"33","author":"Meikle","year":"2012","journal-title":"Ear Hear"},{"key":"R25-20230726","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1016\/j.neuroscience.2012.04.001","article-title":"Multisensory dysfunction accompanies crossmodal plasticity following adult hearing impairment.","volume":"214","author":"Meredith","year":"2012","journal-title":"Neuroscience"},{"key":"R26-20230726","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1001\/archotol.1996.01890140029007","article-title":"Development of the Tinnitus Handicap Inventory.","volume":"122","author":"Newman","year":"1996","journal-title":"Arch Otolaryngol Head Neck Surg"},{"key":"R27-20230726","doi-asserted-by":"crossref","first-page":"505","DOI":"10.1080\/14992020802070770","article-title":"Unilateral and bilateral cochlear implants and the implant-plus-hearing-aid profile: comparing self-assessed and measured abilities.","volume":"47","author":"Noble","year":"2008","journal-title":"Int J Audiol"},{"key":"R28-20230726","doi-asserted-by":"crossref","first-page":"1089","DOI":"10.1016\/j.neubiorev.2010.11.003","article-title":"An integrative model of tinnitus based on a central gain controlling neural sensitivity.","volume":"35","author":"Nore\u00f1a","year":"2011","journal-title":"Neurosci Biobehav Rev"},{"key":"R29-20230726","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1080\/14992020400050033","article-title":"Tinnitus and cochlear implantation.","volume":"43","author":"Quaranta","year":"2004","journal-title":"Int J Audiol"},{"key":"R30-20230726","doi-asserted-by":"crossref","first-page":"2584","DOI":"10.1002\/lary.25370","article-title":"The effect of cochlear implantation on tinnitus in patients with bilateral hearing loss: A systematic review.","volume":"125","author":"Ramakers","year":"2015","journal-title":"Laryngoscope"},{"key":"R31-20230726","doi-asserted-by":"crossref","first-page":"200","DOI":"10.1097\/00129492-200103000-00014","article-title":"Tinnitus suppression in patients with cochlear implants.","volume":"22","author":"Ruckenstein","year":"2001","journal-title":"Otol Neurotol"},{"key":"R32-20230726","doi-asserted-by":"crossref","first-page":"313","DOI":"10.1016\/j.jcomdis.2007.03.006","article-title":"The role of central nervous system plasticity in tinnitus.","volume":"40","author":"Saunders","year":"2007","journal-title":"J Commun Disord"},{"key":"R33-20230726","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1016\/0304-3959(76)90113-5","article-title":"Graphic representation of pain.","volume":"2","author":"Scott","year":"1976","journal-title":"Pain"},{"key":"R34-20230726","doi-asserted-by":"crossref","first-page":"1291","DOI":"10.1001\/archotol.1992.01880120017004","article-title":"Tinnitus suppression following cochlear implantation. A multifactorial investigation.","volume":"118","author":"Souliere","year":"1992","journal-title":"Arch Otolaryngol Head Neck Surg"},{"key":"R35-20230726","first-page":"1","article-title":"An overview of content analysis.","volume":"7","author":"Stemler","year":"2001","journal-title":"Pract Assess Res Eval"},{"key":"R36-20230726","doi-asserted-by":"crossref","first-page":"781","DOI":"10.3109\/00016489.2015.1024332","article-title":"Relationship between intracochlear electrode position and tinnitus in cochlear implantees.","volume":"135","author":"Todt","year":"2015","journal-title":"Acta Otolaryngol"},{"key":"R37-20230726","doi-asserted-by":"crossref","first-page":"S176","DOI":"10.1044\/1059-0889(2008\/07-0044)","article-title":"Identifying tinnitus subgroups with cluster analysis.","volume":"17","author":"Tyler","year":"2008","journal-title":"Am J Audiol"},{"key":"R38-20230726","first-page":"25","article-title":"Tinnitus in the profoundly hearing-impaired and the effects of cochlear implants.","volume":"165","author":"Tyler","year":"1995","journal-title":"Ann Otol Rhinol Laryngol Suppl"},{"key":"R39-20230726","first-page":"282","article-title":"Advantages and disadvantages reported by some of the better cochlear-implant patients.","volume":"11","author":"Tyler","year":"1990","journal-title":"Am J Otol"},{"key":"R41-20230726","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1016\/j.heares.2011.03.010","article-title":"Tinnitus suppression by low-rate electric stimulation and its electrophysiological mechanisms.","volume":"277","author":"Zeng","year":"2011","journal-title":"Hear Res"},{"key":"R42-20230726","doi-asserted-by":"crossref","first-page":"e88662","DOI":"10.1371\/journal.pone.0088662","article-title":"Abnormal pitch perception produced by cochlear implant stimulation.","volume":"9","author":"Zeng","year":"2014","journal-title":"PLoS One"}],"container-title":["Ear &amp; Hearing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00003446-201901000-00015","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,7,26]],"date-time":"2023-07-26T08:15:13Z","timestamp":1690359313000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00003446-201901000-00015"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,1]]},"references-count":39,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.1097\/aud.0000000000000601","relation":{},"ISSN":["0196-0202"],"issn-type":[{"value":"0196-0202","type":"print"}],"subject":[],"published":{"date-parts":[[2019,1]]}}}