{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,28]],"date-time":"2026-08-28T01:57:27Z","timestamp":1787882247000,"version":"build-2784847793"},"reference-count":39,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019,5]]},"abstract":"<jats:sec>\n            <jats:title>Objectives:<\/jats:title>\n            <jats:p>This study utilized personal noise measurements and fit-testing to evaluate the association between noise exposures and personal attenuation rating (PAR) values among participating workers, and second, to compare the attenuated exposure levels received by the workers and the British Standards Institute\u2019s recommended noise exposure range of 70 to 80 dBA.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Design:<\/jats:title>\n            <jats:p>We measured hearing protection device (HPD) attenuation among a sample of 91 workers at 2 US metal manufacturing facilities, through performance of personal noise dosimetry measurements and HPD fit-testing over multiple work shifts. We compared this testing with participant questionnaires and annual audiometric hearing threshold results.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>The average 8-hr time-weighted average noise exposures for study participants was 79.8 dBA (SD = 7.0 dBA), and the average PAR from fit-testing was 20.1 dB (\u00b16.7 dB). While differences existed between sites, 84% of the 251 PAR measurements resulted in effective protection levels below the recommended 70 dBA (indicating overprotection), while workers were underprotected (i.e., effective exposures &gt;80 dBA) during &lt;1% of monitored shifts. Our results also demonstrated a significant positive relationship between measured noise exposure and PAR among non\u2013custom-molded plug users (<jats:italic toggle=\"yes\">p<\/jats:italic> = 0.04). Non\u2013custom-molded plug wearers also showed a significant increase in PAR by sequential fit-test interaction (<jats:italic toggle=\"yes\">p<\/jats:italic> = 0.01), where on average, subsequent fit-testing resulted in increasingly higher HPD attenuation. Workers at site 1 showed higher PARs. PARs were significantly related to race, even when adjusting for site location. While age, hearing threshold level, task, and self-reported tinnitus showed no significant effect on individual PAR in an unadjusted model, site, race, and sand- or water-blasting activities were significant predictors in adjusted models. Within-worker variability in time-weighted averages and PARs across repeated measurements was substantially lower than variability between workers.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>Careful selection of HPDs is necessary to minimize instances of overprotection to workers in low and moderate occupational noise environments. The use of fit-testing in hearing conservation programs to evaluate PAR is recommended to avoid overprotection from noise exposure while also minimizing instances of under-attenuation.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/aud.0000000000000650","type":"journal-article","created":{"date-parts":[[2018,8,30]],"date-time":"2018-08-30T23:01:35Z","timestamp":1535670095000},"page":"680-689","source":"Crossref","is-referenced-by-count":24,"title":["Hearing Protector Attenuation and Noise Exposure Among Metal Manufacturing Workers"],"prefix":"10.1097","volume":"40","author":[{"given":"Stephanie K.","family":"Sayler","sequence":"first","affiliation":[{"name":"Department of Environmental Health Sciences, University of Michigan School of Public Health, Ann Arbor, Michigan, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter M.","family":"Rabinowitz","sequence":"additional","affiliation":[{"name":"Department of Environmental and Occupational Health Sciences, University of Washington School of Public Health, Seattle, Washington, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Deron","family":"Galusha","sequence":"additional","affiliation":[{"name":"Yale School of Medicine, New Haven, Connecticut, USA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kan","family":"Sun","sequence":"additional","affiliation":[{"name":"Department of Environmental Health Sciences, University of Michigan School of Public Health, Ann Arbor, Michigan, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Richard L.","family":"Neitzel","sequence":"additional","affiliation":[{"name":"Department of Environmental Health Sciences, University of Michigan School of Public Health, Ann Arbor, Michigan, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R2-20230726","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1080\/10803548.2009.11076799","article-title":"Assessing differences in methodologies for effective noise exposure calculation.","volume":"15","author":"Arezes","year":"2009","journal-title":"Int J Occup Saf Ergon"},{"key":"R3-20230726","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1080\/19338244.2015.1089828","article-title":"Hearing protection devices: Use at work predicts use at play.","volume":"71","author":"Beach","year":"2016","journal-title":"Arch Environ Occup Health"},{"key":"R5-20230726","doi-asserted-by":"crossref","first-page":"665","DOI":"10.1121\/1.423236","article-title":"Development of a new standard laboratory protocol for estimating the field attenuation of hearing protection devices. Part III. The validity of using subject-fit data.","volume":"103","author":"Berger","year":"1998","journal-title":"J Acoust Soc Am"},{"key":"R7-20230726","doi-asserted-by":"crossref","first-page":"294","DOI":"10.1080\/15459624.2016.1250002","article-title":"Inter-laboratory comparison of three earplug fit-test systems.","volume":"14","author":"Byrne","year":"2017","journal-title":"J Occup Environ Hyg"},{"key":"R8-20230726","doi-asserted-by":"crossref","first-page":"75","DOI":"10.5271\/sjweh.3450","article-title":"Association between ambient noise exposure, hearing acuity, and risk of acute occupational injury.","volume":"41","author":"Cantley","year":"2015a","journal-title":"Scand J Work Environ Health"},{"key":"R9-20230726","doi-asserted-by":"crossref","first-page":"S30","DOI":"10.3109\/14992027.2014.981305","article-title":"Does tinnitus, hearing asymmetry, or hearing loss predispose to occupational injury risk?","volume":"54","author":"Cantley","year":"2015b","journal-title":"Int J Audiol"},{"key":"R10-20230726","first-page":"176","article-title":"Knowledge, behaviors, and attitudes about hearing loss and hearing protection among racial\/ethnically diverse young adults.","volume":"96","author":"Crandell","year":"2004","journal-title":"J Natl Med Assoc"},{"key":"R11-20230726","doi-asserted-by":"crossref","first-page":"D125","DOI":"10.1080\/15459624.2011.626262","article-title":"Acceptance of a semi-custom hearing protector by manufacturing workers.","volume":"8","author":"Davis","year":"2011","journal-title":"J Occup Environ Hyg"},{"key":"R12-20230726","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1097\/AUD.0b013e3182a143ec","article-title":"Exchange rates for intermittent and fluctuating occupational noise: A systematic review of studies of human permanent threshold shift.","volume":"35","author":"Dobie","year":"2014","journal-title":"Ear Hear"},{"key":"R13-20230726","first-page":"130","article-title":"Noise labeling requirements for hearing protectors.","volume":"44","year":"1979","journal-title":"Fed Regist"},{"key":"R14-20230726","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1016\/j.jsr.2016.11.005","article-title":"Noise and neurotoxic chemical exposure relationship to workplace traumatic injuries: A review.","volume":"60","author":"Estill","year":"2017","journal-title":"J Safety Res"},{"issue":"Suppl 1","key":"R15-20230726","doi-asserted-by":"crossref","first-page":"S30","DOI":"10.3109\/14992027.2015.1129460","article-title":"Speech recognition in noise under hearing protection: A computational study of the combined effects of hearing loss and hearing protector attenuation.","volume":"55","author":"Gigu\u00e8re","year":"2016","journal-title":"Int J Audiol"},{"key":"R16-20230726","doi-asserted-by":"crossref","first-page":"e88","DOI":"10.1136\/injuryprev-2013-040828","article-title":"Occupational noise exposure and noise-induced hearing loss are associated with work-related injuries leading to admission to hospital.","volume":"21","author":"Girard","year":"2015","journal-title":"Inj Prev"},{"key":"R17-20230726","doi-asserted-by":"crossref","first-page":"309","DOI":"10.1590\/2317-1782\/20152014139","article-title":"Perception of hearing protectors by workers that participate in hearing preservation programs: A preliminary study.","volume":"27","author":"Gon\u00e7alves","year":"2015","journal-title":"Codas"},{"key":"R18-20230726","doi-asserted-by":"crossref","first-page":"1001","DOI":"10.1002\/ajim.22323","article-title":"Do hearing protectors protect hearing?","volume":"57","author":"Groenewold","year":"2014","journal-title":"Am J Ind Med"},{"key":"R19-20230726","doi-asserted-by":"crossref","first-page":"274","DOI":"10.1001\/jamaoto.2016.3527","article-title":"Declining prevalence of hearing loss in US adults aged 20 to 69 years.","volume":"143","author":"Hoffman","year":"2017","journal-title":"JAMA Otolaryngol Head Neck Surg"},{"key":"R20-20230726","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1891\/rtnp.19.1.63.66339","article-title":"Ethnic differences in predictors of hearing protection behavior between Black and White workers.","volume":"19","author":"Hong","year":"2005","journal-title":"Res Theory Nurs Pr"},{"issue":"Supp1","key":"R22-20230726","doi-asserted-by":"crossref","first-page":"S51","DOI":"10.1080\/14992027.2017.1400188","article-title":"Detection and reaction thresholds for reverse alarms in noise with and without passive hearing protection.","volume":"57","author":"Laroche","year":"2018","journal-title":"Int J Audiol"},{"key":"R23-20230726","first-page":"45","article-title":"The fit testing revolution.","volume":"83","author":"Laws","year":"2014","journal-title":"Hear Prot"},{"key":"R24-20230726","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1080\/15459624.2014.987385","article-title":"Effectiveness evaluation of existing noise controls in a deep shaft underground mine.","volume":"12","author":"Lutz","year":"2015","journal-title":"J Occup Environ Hyg"},{"issue":"Suppl 1","key":"R25-20230726","doi-asserted-by":"crossref","first-page":"S3","DOI":"10.3109\/14992027.2012.743047","article-title":"Impact of daily noise exposure monitoring on occupational noise exposures in manufacturing workers.","volume":"52","author":"McTague","year":"2013","journal-title":"Int. J. Audiol"},{"key":"R26-20230726","doi-asserted-by":"crossref","first-page":"688","DOI":"10.1080\/14992027.2016.1204470","article-title":"Hearing protector fit testing with off-shore oil-rig inspectors in Louisiana and Texas.","volume":"55","author":"Murphy","year":"2016","journal-title":"Int J Audiol"},{"key":"R27-20230726","doi-asserted-by":"crossref","first-page":"405","DOI":"10.1093\/annhyg\/mev088","article-title":"Injury risk and noise exposure in firefighter training operations.","volume":"60","author":"Neitzel","year":"2016","journal-title":"Ann Occup Hyg"},{"key":"R28-20230726","first-page":"679","article-title":"Variability of real-world hearing protector attenuation measurements.","volume":"50","author":"Neitzel","year":"2006","journal-title":"Ann Occup Hyg"},{"key":"R30-20230726","first-page":"187","article-title":"Training in using earplugs or using earplugs with a higher than necessary noise reduction rating? A randomized clinical trial.","volume":"5","author":"Salmani Nodoushan","year":"2014","journal-title":"Int J Occup Environ Med"},{"key":"R31-20230726","first-page":"9738","article-title":"Occupational noise exposure: Hearing conservation amendment; final rule.","volume":"48","year":"1983","journal-title":"Fed Reg"},{"key":"R32-20230726","doi-asserted-by":"crossref","first-page":"611","DOI":"10.1202\/0002-8894(2001)062<0611:IARTUO>2.0.CO;2","article-title":"Is acculturation related to use of hearing protection?","volume":"62","author":"Rabinowitz","year":"2001","journal-title":"AIHAJ"},{"key":"R33-20230726","doi-asserted-by":"crossref","first-page":"716","DOI":"10.1136\/oemed-2011-100455","article-title":"The dose-response relationship between in-ear occupational noise exposure and hearing loss.","volume":"70","author":"Rabinowitz","year":"2013","journal-title":"Occup Environ Med"},{"key":"R34-20230726","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1891\/rtnp.20.2.127","article-title":"Predictors of hearing protection use for Hispanic and non-Hispanic White factory workers.","volume":"20","author":"Raymond","year":"2006","journal-title":"Res Theory Nurs Pr"},{"key":"R35-20230726","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1590\/2317-1782\/20162014146","article-title":"Avalia\u00e7\u00e3o do protetor auditivo em situa\u00e7\u00e3o real de trabalho pelo m\u00e9todo field Microphone-in-real-ear.","volume":"28","author":"Rocha","year":"2016","journal-title":"CoDAS"},{"key":"R36-20230726","doi-asserted-by":"crossref","first-page":"514","DOI":"10.1590\/2317-1782\/20152014128","article-title":"Training on hearing protector insertion improves noise attenuation.","volume":"27","author":"Samelli","year":"2015","journal-title":"CoDAS"},{"key":"R37-20230726","doi-asserted-by":"crossref","DOI":"10.4103\/1463-1741.77216","article-title":"Individual fit-testing of earplugs: A review of uses.","volume":"13","author":"Schulz","year":"2011","journal-title":"Noise Health"},{"key":"R38-20230726","doi-asserted-by":"crossref","first-page":"493","DOI":"10.1093\/annhyg\/mei009","article-title":"Alternative metrics for noise exposure among construction workers.","volume":"49","author":"Seixas","year":"2005","journal-title":"Ann Occup Hyg"},{"key":"R39-20230726","doi-asserted-by":"crossref","first-page":"491","DOI":"10.3928\/21650799-20140902-01","article-title":"Attitudes toward use of hearing protection devices and effects of an intervention on fit-testing results.","volume":"62","author":"Smith","year":"2014","journal-title":"Workplace Health Saf"},{"key":"R40-20230726","doi-asserted-by":"crossref","first-page":"358","DOI":"10.1002\/ajim.20690","article-title":"Exposure to hazardous workplace noise and use of hearing protection devices among US workers\u2013NHANES, 1999\u20132004.","volume":"52","author":"Tak","year":"2009","journal-title":"Am J Ind Med"},{"key":"R41-20230726","first-page":"571","article-title":"Consistency of attenuation across multiple fittings of custom and non-custom earplugs.","volume":"57","author":"Tufts","year":"2013","journal-title":"Ann Occup Hyg"},{"key":"R42-20230726","doi-asserted-by":"crossref","first-page":"1","DOI":"10.4103\/1463-1741.199238","article-title":"Using auditory steady-state responses for measuring hearing protector attenuation.","volume":"19","author":"Valentin","year":"2017","journal-title":"Noise Health"},{"key":"R43-20230726","doi-asserted-by":"crossref","first-page":"S84","DOI":"10.3109\/14992027.2013.857436","article-title":"Interventions to prevent occupational noise-induced hearing loss: A Cochrane systematic review.","volume":"53","author":"Verbeek","year":"2014","journal-title":"Int J Audiol"},{"key":"R44-20230726","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1080\/10803548.2009.11076802","article-title":"Individual fit testing of hearing protection devices.","volume":"15","author":"Voix","year":"2009","journal-title":"Int J Occup Saf Ergon"}],"container-title":["Ear &amp; Hearing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00003446-201905000-00023","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,7,26]],"date-time":"2023-07-26T08:50:38Z","timestamp":1690361438000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00003446-201905000-00023"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,5]]},"references-count":39,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.1097\/aud.0000000000000650","relation":{},"ISSN":["0196-0202"],"issn-type":[{"value":"0196-0202","type":"print"}],"subject":[],"published":{"date-parts":[[2019,5]]}}}