{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,8]],"date-time":"2025-10-08T16:38:33Z","timestamp":1759941513972},"reference-count":35,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019,5]]},"abstract":"<jats:sec>\n            <jats:title>Objectives:<\/jats:title>\n            <jats:p>Active middle ear implants (AMEI) have been used to treat hearing loss in patients for whom conventional hearing aids are unsuccessful for varied biologic or personal reasons. Several studies have discussed feedback as a potential complication of AMEI usage, though the feedback pathway is not well understood. While reverse propagation of an acoustic signal through the ossicular chain and tympanic membrane constitutes an air-conducted source of feedback, the implanted nature of the device microphone near the mastoid cortex suggests that bone conduction pathways may potentially be another significant factor. This study examines the relative contributions of potential sources of feedback during stimulation with an AMEI.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Design:<\/jats:title>\n            <jats:p>Four fresh-frozen, hemi-sectioned, human cadaver specimens were prepared with a mastoid antrostomy and atticotomy to visualize the posterior incus body. A Carina active middle ear implant actuator (Cochlear Ltd., Boulder, CO) was coupled to the incus by two means: (1) a stereotactic arm mounted independently of the specimen and (2) a fixation bracket anchored directly to the mastoid cortical bone. The actuator was driven with pure-tone frequencies in 1\/4 octave steps from 500 to 6000 Hz. Acoustic sound intensity in the ear canal was measured with a probe tube microphone (Bruel &amp; Kj\u00e6r, N\u00e6rum, Denmark). Bone-conducted vibration was quantified with a single-axis laser Doppler vibrometer (Polytec Inc., Irvine, CA) from both a piece of reflective tape placed on the skin overlying the mastoid and a bone-anchored titanium screw and pedestal (Cochlear Ltd., Centennial, CO) implanted in the cortical mastoid bone.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Microphone measurements revealed ear-canal pressures of 60\u201389 dB SPL, peaking in the frequency range below 2\u2009kHz. Peak LDV measurements were greatest on the mastoid bone (0.32\u20130.79\u2009mm\/s with mounting bracket and 0.21\u20130.36\u2009mm\/s with the stereotactic suspension); peak measurements on the skin ranged from 0.05 to 0.15\u2009mm\/s with the bracket and 0.03 to 0.13\u2009mm\/s with stereotactic suspension.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>AMEI produce both air- and bone-conducted signals of adequate strength to be detected by the implanted device microphone, potentially resulting in reamplification. Understanding the relative contribution of these sources may play an important role in the development of targeted mitigation algorithms, as well as surgical techniques emphasizing acoustic isolation.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/aud.0000000000000655","type":"journal-article","created":{"date-parts":[[2018,9,8]],"date-time":"2018-09-08T10:27:06Z","timestamp":1536402426000},"page":"725-731","source":"Crossref","is-referenced-by-count":3,"title":["Air- and Bone-Conducted Sources of Feedback With an Active Middle Ear Implant"],"prefix":"10.1097","volume":"40","author":[{"given":"Renee M.","family":"Banakis Hartl","sequence":"first","affiliation":[{"name":"Department of Otolaryngology, University of Colorado School of Medicine, Aurora, Colorado, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"James R.","family":"Easter","sequence":"additional","affiliation":[{"name":"Cochlear Boulder LLC, Boulder, Colorado, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mohamed A.","family":"Alhussaini","sequence":"additional","affiliation":[{"name":"Department of Otolaryngology, University of Colorado School of Medicine, Aurora, Colorado, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daniel J.","family":"Tollin","sequence":"additional","affiliation":[{"name":"Department of Otolaryngology, University of Colorado School of Medicine, Aurora, Colorado, USA"},{"name":"Department of Physiology and Biophysics, University of Colorado School of Medicine, Aurora, Colorado, USA."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Herman A.","family":"Jenkins","sequence":"additional","affiliation":[{"name":"Department of Otolaryngology, University of Colorado School of Medicine, Aurora, Colorado, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"issue":"6","key":"R1-20230726","first-page":"16","article-title":"An introduction to MarkeTrak IX: A new baseline for the hearing aid market.","volume":"22","author":"Abrams","year":"2015","journal-title":"Hearing Review"},{"key":"R2-20230726","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1177\/108471389600100202","article-title":"Acoustic feedback and other audible artifacts in hearing AIDS.","volume":"1","author":"Agnew","year":"1996","journal-title":"Trends Amplif"},{"key":"R3-20230726","doi-asserted-by":"crossref","first-page":"1291","DOI":"10.1097\/MAO.0000000000001184","article-title":"A preliminary investigation of the air-bone gap: Changes in intracochlear sound pressure with air- and bone-conducted stimuli after cochlear implantation.","volume":"37","author":"Banakis Hartl","year":"2016","journal-title":"Otol Neurotol"},{"key":"R4-20230726","doi-asserted-by":"crossref","first-page":"859","DOI":"10.1016\/j.otc.2014.08.001","article-title":"Sound transfer of active middle ear implants.","volume":"47","author":"Beleites","year":"2014","journal-title":"Otolaryngol Clin North Am"},{"key":"R5-20230726","doi-asserted-by":"crossref","first-page":"424","DOI":"10.1097\/MAO.0b013e3181cabd42","article-title":"Active middle ear implant compared with open-fit hearing aid in sloping high-frequency sensorineural hearing loss.","volume":"31","author":"Boeheim","year":"2010","journal-title":"Otol Neurotol"},{"key":"R6-20230726","doi-asserted-by":"crossref","first-page":"3631","DOI":"10.1007\/s00405-016-3998-1","article-title":"The Carina\u00a9 middle ear implant: Surgical and functional outcomes.","volume":"273","author":"Bruschini","year":"2016","journal-title":"Eur Arch Otorhinolaryngol"},{"key":"R7-20230726","doi-asserted-by":"crossref","first-page":"1147","DOI":"10.3109\/00016481003671244","article-title":"Fully implantable Otologics MET Carina(\u2122) device for the treatment of sensorineural and mixed hearing loss: Audio-otological results.","volume":"130","author":"Bruschini","year":"2010","journal-title":"Acta Otolaryngol"},{"key":"R8-20230726","first-page":"79","article-title":"Fully implantable Otologics MET Carina device for the treatment of sensorineural hearing loss. Preliminary surgical and clinical results.","volume":"29","author":"Bruschini","year":"2009","journal-title":"Acta Otorhinolaryngol Ital"},{"issue":"Suppl 2","key":"R9-20230726","doi-asserted-by":"crossref","first-page":"S8","DOI":"10.1017\/S0022215113001151","article-title":"Efficacy of the active middle-ear implant in patients with sensorineural hearing loss.","volume":"127","author":"Butler","year":"2013","journal-title":"J Laryngol Otol"},{"key":"R10-20230726","doi-asserted-by":"crossref","first-page":"893","DOI":"10.1016\/j.otc.2014.08.004","article-title":"Historical development of active middle ear implants.","volume":"47","author":"Carlson","year":"2014","journal-title":"Otolaryngol Clin North Am"},{"key":"R11-20230726","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1177\/108471380400800402","article-title":"Challenges and recent developments in hearing aids. Part II. Feedback and occlusion effect reduction strategies, laser shell manufacturing processes, and other signal processing technologies.","volume":"8","author":"Chung","year":"2004","journal-title":"Trends Amplif"},{"key":"R12-20230726","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/0196-0709(90)90162-O","article-title":"Totally implantable hearing aids: The effects of skin thickness on microphone function.","volume":"11","author":"Deddens","year":"1990","journal-title":"Am J Otolaryngol"},{"key":"R13-20230726","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1097\/MAO.0b013e3182785261","article-title":"Techniques to improve the efficiency of a middle ear implant: Effect of different methods of coupling to the ossicular chain.","volume":"34","author":"Dev\u00e8ze","year":"2013","journal-title":"Otol Neurotol"},{"key":"R14-20230726","doi-asserted-by":"crossref","first-page":"1541","DOI":"10.1097\/MAO.0000000000001232","article-title":"Intracochlear pressure transients during cochlear implant electrode insertion.","volume":"37","author":"Greene","year":"2016","journal-title":"Otol Neurotol"},{"key":"R15-20230726","doi-asserted-by":"crossref","first-page":"1554","DOI":"10.1097\/MAO.0000000000000838","article-title":"Cochlear implant electrode effect on sound energy transfer within the cochlea during acoustic stimulation.","volume":"36","author":"Greene","year":"2015","journal-title":"Otol Neurotol"},{"key":"R16-20230726","doi-asserted-by":"crossref","first-page":"967","DOI":"10.1016\/j.otc.2014.08.007","article-title":"Otologics active middle ear implants.","volume":"47","author":"Jenkins","year":"2014","journal-title":"Otolaryngol Clin North Am"},{"key":"R17-20230726","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1016\/j.otohns.2007.03.012","article-title":"U.S. phase I preliminary results of use of the otologics MET fully-implantable ossicular stimulator.","volume":"137","author":"Jenkins","year":"2007a","journal-title":"Otolaryngol Head Neck Surg"},{"key":"R18-20230726","doi-asserted-by":"crossref","first-page":"579","DOI":"10.1097\/01.mao.0000271700.52982.d8","article-title":"Anatomical vibrations that implantable microphones must overcome.","volume":"28","author":"Jenkins","year":"2007b","journal-title":"Otol Neurotol"},{"key":"R19-20230726","doi-asserted-by":"crossref","first-page":"360","DOI":"10.1080\/00016480601089424","article-title":"Intraoperative ossicular loading with the otologics fully implantable hearing device.","volume":"127","author":"Jenkins","year":"2007c","journal-title":"Acta Otolaryngol"},{"key":"R20-20230726","doi-asserted-by":"crossref","first-page":"240","DOI":"10.1111\/j.1749-4486.2012.02492.x","article-title":"Clinical evaluation of a fully implantable hearing device in six patients with mixed and sensorineural hearing loss: Our experience.","volume":"37","author":"Kam","year":"2012","journal-title":"Clin Otolaryngol"},{"key":"R21-20230726","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1016\/0021-9924(91)90026-F","article-title":"The problem of feedback in hearing aids.","volume":"24","author":"Kates","year":"1991","journal-title":"J Commun Disord"},{"issue":"1","key":"R22-20230726","first-page":"20","article-title":"MarkeTrak III: Why 20 million in US don\u2019t use hearing aids for their hearing loss.","volume":"46","author":"Kochkin","year":"1993","journal-title":"Hearing J"},{"key":"R23-20230726","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1159\/000454666","article-title":"A retrospective multicentre cohort review of patient characteristics and surgical aspects versus the long-term outcomes for recipients of a fully implantable active middle ear implant.","volume":"21","author":"Lefebvre","year":"2016","journal-title":"Audiol Neurootol"},{"key":"R24-20230726","doi-asserted-by":"crossref","DOI":"10.1177\/2331216514558271","article-title":"Music and hearing aids.","volume":"18","author":"Madsen","year":"2014","journal-title":"Trends Hearing"},{"key":"R25-20230726","doi-asserted-by":"crossref","first-page":"1196","DOI":"10.1097\/MAO.0b013e3181c34898","article-title":"European results with totally implantable carina placed on the round window: 2-Year follow-up.","volume":"30","author":"Martin","year":"2009","journal-title":"Otol Neurotol"},{"key":"R26-20230726","doi-asserted-by":"crossref","first-page":"1403","DOI":"10.1097\/MAO.0000000000000814","article-title":"Effects of skin thickness on cochlear input signal using transcutaneous bone conduction implants.","volume":"36","author":"Mattingly","year":"2015","journal-title":"Otol Neurotol"},{"key":"R27-20230726","doi-asserted-by":"crossref","first-page":"e110636","DOI":"10.1371\/journal.pone.0110636","article-title":"Carina\u00ae and Esteem\u00ae: A systematic review of fully implantable hearing devices.","volume":"9","author":"Pulcherio","year":"2014","journal-title":"PLoS One"},{"key":"R28-20230726","doi-asserted-by":"crossref","first-page":"340","DOI":"10.1017\/S0022215116000748","article-title":"Comparison of Carina active middle-ear implant with conventional hearing aids for mixed hearing loss.","volume":"130","author":"Sava\u015f","year":"2016","journal-title":"J Laryngol Otol"},{"key":"R29-20230726","doi-asserted-by":"crossref","first-page":"1245","DOI":"10.1097\/01.mao.0000187236.10842.d5","article-title":"Bone-conducted sound: Physiological and clinical aspects.","volume":"26","author":"Stenfelt","year":"2005a","journal-title":"Otol Neurotol"},{"key":"R30-20230726","doi-asserted-by":"crossref","first-page":"2373","DOI":"10.1121\/1.2005847","article-title":"Transmission properties of bone conducted sound: Measurements in cadaver heads.","volume":"118","author":"Stenfelt","year":"2005b","journal-title":"J Acoust Soc Am"},{"key":"R31-20230726","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1159\/000283006","article-title":"Round window membrane implantation with an active middle ear implant: A study of the effects on the performance of round window exposure and transducer tip diameter in human cadaveric temporal bones.","volume":"15","author":"Tringali","year":"2010","journal-title":"Audiol Neurootol"},{"key":"R32-20230726","doi-asserted-by":"crossref","first-page":"27","DOI":"10.3109\/00016489.2010.507779","article-title":"Intraoperative adjustments to optimize active middle ear implant performance.","volume":"131","author":"Tringali","year":"2011","journal-title":"Acta Otolaryngol"},{"key":"R33-20230726","first-page":"20","article-title":"Indications and candidacy for active middle ear implants.","volume":"69","author":"Wagner","year":"2010","journal-title":"Adv Otorhinolaryngol"},{"key":"R34-20230726","first-page":"72","article-title":"Totally implantable active middle ear implants: Ten years\u2019 experience at the University of T\u00fcbingen.","volume":"69","author":"Zenner","year":"2010","journal-title":"Adv Otorhinolaryngol"},{"key":"R35-20230726","doi-asserted-by":"crossref","first-page":"513","DOI":"10.1097\/MAO.0000000000001015","article-title":"Active middle ear implantation: Long-term medical and technical follow-up, implant survival, and complications.","volume":"37","author":"Zwartenkot","year":"2016","journal-title":"Otol Neurotol"}],"container-title":["Ear &amp; Hearing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00003446-201905000-00027","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,7,26]],"date-time":"2023-07-26T08:51:40Z","timestamp":1690361500000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00003446-201905000-00027"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,5]]},"references-count":35,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.1097\/aud.0000000000000655","relation":{},"ISSN":["0196-0202"],"issn-type":[{"value":"0196-0202","type":"print"}],"subject":[],"published":{"date-parts":[[2019,5]]}}}