{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,14]],"date-time":"2026-01-14T14:25:18Z","timestamp":1768400718033,"version":"3.49.0"},"reference-count":43,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019,5]]},"abstract":"<jats:sec>\n            <jats:title>Objectives:<\/jats:title>\n            <jats:p>The upper loudness limit of electrical stimulation in cochlear implant patients is sometimes set using electrically elicited stapedius reflex thresholds (eSRTs), especially in children for whom reporting skills may be limited. In unilateral cochlear implant patients, eSRT levels are measured typically in the contralateral unimplanted ear because the ability to measure eSRTs in the implanted ear is likely to be limited due to the cochlear implant surgery and consequential changes in middle ear dynamics. This practice is particularly limiting in the case of fitting bilaterally implanted pediatric cases because there is no unimplanted ear option to choose for eSRT measurement. The goal of this study was to identify an improved measurement protocol to increase the success of eSRT measurement in ipsilateral or contralateral or both implanted ears of pediatric cochlear implant recipients. This work hypothesizes that use of a higher probe frequency (e.g., 1000 Hz compared with the 226 Hz standard), which is closer to the mechanical middle ear resonant frequency, may be more effective in measuring middle ear muscle contraction in either ear.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Design:<\/jats:title>\n            <jats:p>In the present study, eSRTs were measured using multiple probe frequencies (226, 678, and 1000 Hz) in the ipsilateral and contralateral ears of 19 children with unilateral Advanced Bionics (AB) cochlear implants (mean age = 8.6 years, SD = 2.29). An integrated middle ear analyzer designed by AB was used to elicit and detect stapedius reflexes and assign eSRT levels. In the integrated middle ear analyzer system, an Interacoustics Titan middle ear analyzer was used to perform middle ear measurements in synchrony with research software running on an AB Neptune speech processor, which controlled the delivery of electrical pulse trains at varying levels to the test subject. Changes in middle ear acoustic admittance following an electrical pulse train stimulus indicated the occurrence of an electrically elicited stapedius reflex.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Of the 19 ears tested, ipsilateral eSRTs were successfully measured in 3 (16%), 4 (21%), and 7 (37%) ears using probe tones of 226, 678, and 1000 Hz, respectively. Contralateral eSRT levels were measured in 11 (58%), 13 (68%), and 13 (68%) ears using the three different probe frequencies, respectively. A significant difference was found in the incidence of successful eSRT measurement as a function of probe frequency in the ipsilateral ears with the greatest pair-wise difference between the 226 and 1000 Hz probe. A significant increase in contralateral eSRT measurement success as a function of probe frequency was not found. These findings are consistent with the idea that changes in middle ear mechanics, secondary to cochlear implant surgery, may interfere with the detection of stapedius muscle contraction in the ipsilateral middle ear. The best logistic, mixed-effects model of the occurrence of successful eSRT measures included ear of measurement and probe frequency as significant fixed effects. No significant differences in average eSRT levels were observed across ipsilateral and contralateral measurements or as a function of probe frequency.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion:<\/jats:title>\n            <jats:p>Typically, measurement of stapedius reflexes is less successful in the implanted ears of cochlear implant recipients compared with measurements in the contralateral, unimplanted ear. The ability to measure eSRT levels ipsilaterally can be improved by using a higher probe frequency.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/aud.0000000000000656","type":"journal-article","created":{"date-parts":[[2018,10,4]],"date-time":"2018-10-04T06:52:34Z","timestamp":1538635954000},"page":"732-740","source":"Crossref","is-referenced-by-count":18,"title":["Effect of Probe-Tone Frequency on Ipsilateral and Contralateral Electrical Stapedius Reflex Measurement in Children With Cochlear Implants"],"prefix":"10.1097","volume":"40","author":[{"given":"Lizette","family":"Carranco Hernandez","sequence":"first","affiliation":[{"name":"Instituto Nacional De Enfermedades Respiratorias, Mexico City, Mexico"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lisette","family":"Cristerna S\u00e1nchez","sequence":"additional","affiliation":[{"name":"Instituto Nacional De Enfermedades Respiratorias, Mexico City, Mexico"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Miriam","family":"Camacho Olivares","sequence":"additional","affiliation":[{"name":"Instituto Nacional De Enfermedades Respiratorias, Mexico City, Mexico"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Carina","family":"Rodr\u00edguez","sequence":"additional","affiliation":[{"name":"Advanced Bionics LLC, Valencia, CA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Charles C.","family":"Finley","sequence":"additional","affiliation":[{"name":"Advanced Bionics LLC, Valencia, CA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Aniket A.","family":"Saoji","sequence":"additional","affiliation":[{"name":"Department of Otolaryngology, West Virginia University, WV."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20230726","doi-asserted-by":"crossref","first-page":"93","DOI":"10.3109\/14992020209090399","article-title":"Relationship of intraoperative electrically evoked stapedius reflex thresholds to maximum comfortable loudness levels of children with cochlear implants.","volume":"41","author":"Allum","year":"2002","journal-title":"Int J Audiol"},{"issue":"1","key":"R2-20230726","doi-asserted-by":"crossref","first-page":"49","DOI":"10.4103\/1012-5574.175848","article-title":"The relationship between the electrical stapedial muscle reflex threshold and electrical and behavioral measures in cochlear implant patients.","volume":"32","author":"Asal","year":"2016","journal-title":"Egyptian J Otolaryngol"},{"issue":"1","key":"R3-20230726","doi-asserted-by":"crossref","first-page":"1","DOI":"10.18637\/jss.v067.i01","article-title":"Fitting linear mixed-effects models using lme4.","volume":"67","author":"Bates","year":"2015","journal-title":"J Stat Software"},{"key":"R4-20230726","doi-asserted-by":"crossref","first-page":"370","DOI":"10.1097\/00003446-199010000-00008","article-title":"Electrically elicited stapedius reflex in cochlear implant patients.","volume":"11","author":"Battmer","year":"1990","journal-title":"Ear Hear"},{"key":"R5-20230726","doi-asserted-by":"crossref","first-page":"233","DOI":"10.3109\/01050397909076325","article-title":"Multiple probe frequency acoustic reflex measurements.","volume":"8","author":"Bennett","year":"1979","journal-title":"Scand Audiol"},{"key":"R6-20230726","doi-asserted-by":"crossref","first-page":"963","DOI":"10.1001\/archotol.127.8.963","article-title":"Measurement of comfort levels by means of electrical stapedial reflex in children.","volume":"127","author":"Bresnihan","year":"2001","journal-title":"Arch Otolaryngol Head Neck Surg"},{"key":"R7-20230726","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1002\/cii.18","article-title":"Investigations into electrically evoked stapedius reflex measures and subjective loudness percepts in the MED-EL COMBI 40+ cochlear implant.","volume":"6","author":"Brickley","year":"2005","journal-title":"Cochlear Implants Int"},{"key":"R8-20230726","doi-asserted-by":"crossref","first-page":"723","DOI":"10.1017\/S0022215109004290","article-title":"Effect of cochlear implant electrode insertion on middle-ear function as measured by intra-operative laser Doppler vibrometry.","volume":"123","author":"Donnelly","year":"2009","journal-title":"J Laryngol Otol"},{"issue":"1 Suppl","key":"R9-20230726","doi-asserted-by":"crossref","first-page":"24S","DOI":"10.1097\/01.AUD.0000051687.99218.0F","article-title":"Factors associated with development of speech perception skills in children implanted by age five.","volume":"24","author":"Geers","year":"2003","journal-title":"Ear Hear"},{"key":"R10-20230726","doi-asserted-by":"crossref","first-page":"220","DOI":"10.1179\/1754762811Y.0000000022","article-title":"Toward a method for programming balanced bilateral cochlear implant stimulation levels in children.","volume":"13","author":"Gordon","year":"2012","journal-title":"Cochlear Implants Int"},{"key":"R11-20230726","doi-asserted-by":"crossref","first-page":"447","DOI":"10.1097\/01.aud.0000146178.84065.b3","article-title":"Toward a battery of behavioral and objective measures to achieve optimal cochlear implant stimulation levels in children.","volume":"25","author":"Gordon","year":"2004","journal-title":"Ear Hear"},{"key":"R12-20230726","doi-asserted-by":"crossref","first-page":"732","DOI":"10.1080\/00016480510026890","article-title":"Comparisons between neural response imaging thresholds, electrically evoked auditory reflex thresholds and most comfortable loudness levels in CII bionic ear users with HiResolution sound processing strategies.","volume":"125","author":"Han","year":"2005","journal-title":"Acta Otolaryngol"},{"issue":"3 Pt 1","key":"R13-20230726","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1016\/S0194-5998(97)70183-9","article-title":"Electrical middle ear muscle reflex: use in cochlear implant programming.","volume":"117","author":"Hodges","year":"1997","journal-title":"Otolaryngol Head Neck Surg"},{"key":"R14-20230726","doi-asserted-by":"crossref","first-page":"342","DOI":"10.1097\/AUD.0b013e3182741aa7","article-title":"Factors affecting open-set word recognition in adults with cochlear implants.","volume":"34","author":"Holden","year":"2013","journal-title":"Ear Hear"},{"key":"R15-20230726","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1177\/000348940111000106","article-title":"Intraoperative assessment of stapes movement.","volume":"110","author":"Huber","year":"2001","journal-title":"Ann Otol Rhinol Laryngol"},{"key":"R16-20230726","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1590\/2317-1782\/20152014117","article-title":"Acoustic reflex on newborns: the influence of the 226 and 1,000 Hz probes.","volume":"27","author":"Jacob-Corteletti","year":"2015","journal-title":"Codas"},{"key":"R17-20230726","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1001\/archotol.1970.04310040005002","article-title":"Clinical experience with impedance audiometry.","volume":"92","author":"Jerger","year":"1970","journal-title":"Arch Otolaryngol"},{"key":"R18-20230726","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1001\/archotol.1977.00780250039002","article-title":"Diagnostic value of crossed vs uncrossed acoustic reflexes: Eighth nerve and brain stem disorders.","volume":"103","author":"Jerger","year":"1977","journal-title":"Arch Otolaryngol"},{"issue":"2 Pt 1","key":"R19-20230726","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1177\/000348948609500208","article-title":"Stapedius reflex to electrical stimulation in a patient with a cochlear implant.","volume":"95","author":"Jerger","year":"1986","journal-title":"Ann Otol Rhinol Laryngol"},{"key":"R20-20230726","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1097\/00003446-198802000-00010","article-title":"Prediction of dynamic range from stapedius reflex in cochlear implant patients.","volume":"9","author":"Jerger","year":"1988","journal-title":"Ear Hear"},{"issue":"1","key":"R21-20230726","first-page":"70","article-title":"The use of ESRT in fitting children with cochlear implants.","volume":"5","author":"Kosaner","year":"2009","journal-title":"J Int Adv Otol"},{"key":"R22-20230726","doi-asserted-by":"crossref","first-page":"507","DOI":"10.1017\/S0022215100070651","article-title":"The scope and application of current audiometric tests.","volume":"83","author":"Lid\u00e9n","year":"1969","journal-title":"J Laryngol Otol"},{"key":"R23-20230726","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1080\/14670100.2004.11873748","article-title":"ESRT and MCL correlations in experienced paediatric cochlear implant users.","volume":"5","author":"Lorens","year":"2004","journal-title":"Cochlear Implants Int"},{"issue":"Suppl 1","key":"R25-20230726","doi-asserted-by":"crossref","first-page":"S42","DOI":"10.1080\/14992027.2017.1416189","article-title":"Acoustic reflexes are common but not pervasive: Evidence using a diagnostic middle ear analyser.","volume":"57","author":"McGregor","year":"2018","journal-title":"Int J Audiol"},{"key":"R26-20230726","doi-asserted-by":"crossref","first-page":"1524","DOI":"10.1121\/1.1918384","article-title":"Acoustic reflex in man.","volume":"34","author":"Moller","year":"1962","journal-title":"J Acoust Soc Am"},{"key":"R27-20230726","doi-asserted-by":"crossref","first-page":"615","DOI":"10.1080\/14992020802178656","article-title":"Results of multiple-frequency tympanometry measures in normal and otosclerotic middle ears.","volume":"47","author":"Ogut","year":"2008","journal-title":"Int J Audiol"},{"key":"R28-20230726","doi-asserted-by":"crossref","first-page":"639","DOI":"10.1097\/01.mao.0000178145.14010.25","article-title":"ECAP, ESR and subjective levels for two different nucleus 24 electrode arrays.","volume":"26","author":"Polak","year":"2005","journal-title":"Otol Neurotol"},{"key":"R30-20230726","first-page":"175","article-title":"Relationships among comfort levels determined by cochlear implant patient\u2019s self-programming, audiologist\u2019s programming, and electrical stapedius reflex thresholds.","volume":"166","author":"Shallop","year":"1995","journal-title":"Ann Otol Rhinol Laryngol Suppl"},{"key":"R31-20230726","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1097\/00003446-199404000-00008","article-title":"The relationship between electrical acoustic reflex thresholds and behavioral comfort levels in children and adult cochlear implant patients.","volume":"15","author":"Spivak","year":"1994","journal-title":"Ear Hear"},{"key":"R32-20230726","doi-asserted-by":"crossref","first-page":"1225","DOI":"10.1288\/00005537-199410000-00007","article-title":"Programming the cochlear implant based on electrical acoustic reflex thresholds: Patient performance.","volume":"104","author":"Spivak","year":"1994","journal-title":"Laryngoscope"},{"key":"R33-20230726","doi-asserted-by":"crossref","first-page":"436","DOI":"10.1177\/039139889201500712","article-title":"Stapedius reflex in patients with an inner ear prosthesis.","volume":"15","author":"Stephan","year":"1992","journal-title":"Int J Artif Organs"},{"key":"R34-20230726","doi-asserted-by":"crossref","first-page":"143","DOI":"10.3109\/00206099409071875","article-title":"Effect of stimulus duration on stapedius reflex threshold in electrical stimulation via cochlear implant.","volume":"33","author":"Stephan","year":"1994","journal-title":"Audiology"},{"key":"R35-20230726","doi-asserted-by":"crossref","first-page":"13","DOI":"10.3109\/00206090009073049","article-title":"Post-operative stapedius reflex tests with simultaneous loudness scaling in patients supplied with cochlear implants.","volume":"39","author":"Stephan","year":"2000","journal-title":"Audiology"},{"key":"R36-20230726","doi-asserted-by":"crossref","first-page":"111","DOI":"10.3109\/01050399009070761","article-title":"Dynamic range of the contralateral stapedius reflex in cochlear implant patients.","volume":"19","author":"Stephan","year":"1990a","journal-title":"Scand Audiol"},{"key":"R37-20230726","doi-asserted-by":"crossref","first-page":"46","DOI":"10.3109\/00206099009081645","article-title":"Stapedius reflex growth function in cochlear implant patients.","volume":"29","author":"Stephan","year":"1990b","journal-title":"Audiology"},{"issue":"Suppl","key":"R38-20230726","first-page":"48","article-title":"Acoustic reflex in patients with cochlear implants (analog stimulation).","volume":"12","author":"Stephan","year":"1991","journal-title":"Am J Otol"},{"key":"R39-20230726","doi-asserted-by":"crossref","first-page":"227","DOI":"10.3109\/00206098809081593","article-title":"Stapedius reflex threshold in cochlear implant patients.","volume":"27","author":"Stephan","year":"1988","journal-title":"Audiology"},{"key":"R40-20230726","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1159\/000326892","article-title":"Evoked stapedius reflex and compound action potential thresholds versus most comfortable loudness level: Assessment of their relation for charge-based fitting strategies in implant users.","volume":"73","author":"Walkowiak","year":"2011","journal-title":"ORL J Otorhinolaryngol Relat Spec"},{"key":"R41-20230726","doi-asserted-by":"crossref","first-page":"103","DOI":"10.3109\/01050398009076343","article-title":"The neonatal acoustic reflex.","volume":"9","author":"Weatherby","year":"1980","journal-title":"Scand Audiol"},{"key":"R42-20230726","first-page":"1308.5499","article-title":"Linear models and linera mixed effects models in R with linguistic applications.","author":"Winter","year":"2013","journal-title":"arXiv"},{"key":"R43-20230726","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1097\/AUD.0000000000000390","article-title":"Optimizations for the electrically-evoked stapedial reflex threshold measurement in cochlear implant recipients.","volume":"38","author":"Wolfe","year":"2017","journal-title":"Ear Hear"},{"key":"R44-20230726","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1179\/cim.2008.9.2.70","article-title":"Relationships among objective measures and speech perception in adult users of the HiResolution Bionic Ear.","volume":"9","author":"Wolfe","year":"2008","journal-title":"Cochlear Implants Int"},{"key":"R45-20230726","first-page":"1","article-title":"Acoustic impedance of pathological ears.","volume":"15","author":"Zwislocki","year":"1970","journal-title":"ASHA Monogr"}],"container-title":["Ear &amp; Hearing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00003446-201905000-00028","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,7,26]],"date-time":"2023-07-26T08:52:11Z","timestamp":1690361531000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00003446-201905000-00028"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,5]]},"references-count":43,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.1097\/aud.0000000000000656","relation":{},"ISSN":["0196-0202"],"issn-type":[{"value":"0196-0202","type":"print"}],"subject":[],"published":{"date-parts":[[2019,5]]}}}