{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,15]],"date-time":"2026-11-15T02:05:52Z","timestamp":1794708352823,"version":"4.9.1"},"reference-count":37,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019,7]]},"abstract":"<jats:sec>\n            <jats:title>Objectives:<\/jats:title>\n            <jats:p>Self-fitting hearing aids have the potential to increase the accessibility of hearing health care. The aims of this study were to (1) identify factors that are associated with the ability to successfully set up a pair of commercially available self-fitting hearing aids; 2) identify factors that are associated with the need for knowledgeable, personalized support in performing the self-fitting procedure; and (3) evaluate performance of the individual steps in the self-fitting procedure.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Design:<\/jats:title>\n            <jats:p>Sixty adults with hearing loss between the ages of 51 and 85 took part in the study. Half of the participants were current users of bilateral hearing aids; the other half had no previous hearing aid experience. At the first appointment, participants underwent assessments of health locus of control, hearing aid self-efficacy, cognitive status, problem-solving skills, demographic characteristics, and hearing thresholds. At the second appointment, participants followed a set of computer-based instructions accompanied by video clips to self-fit the hearing aids. The self-fitting procedure required participants to customize the physical fit of the hearing aids, insert the hearing aids into the ear, perform self-directed <jats:italic toggle=\"yes\">in situ<\/jats:italic> audiometry, and adjust the resultant settings according to their preference. Participants had access to support with the self-fitting procedure from a trained clinical assistant (CA) at all times.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Forty-one (68%) of the participants achieved a successful self-fitting. Participants who self-fit successfully were significantly more likely than those who were unsuccessful to have had previous experience with hearing aids and to own a mobile device (when controlling for four potential covariates). Of the 41 successful self-fitters, 15 (37%) performed the procedure independently and 26 (63%) sought support from the CA. The successful self-fitters who sought CA support were more likely than those who self-fit independently to have a health locus of control that is externally oriented toward powerful others. Success rates on the individual steps in the self-fitting procedure were relatively high. No one step was more problematic than any other, nor was there a systematic tendency for particular participants to make more errors than others. Steps that required use of the hearing aids in conjunction with the self-fitting app on the participant\u2019s mobile device had the highest rates of support use.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>The findings of this study suggest that nonaudiologic factors should be considered when selecting suitable candidates for the self-fitting hearing aids evaluated in this study. Although computer-based instructions and video clips were shown to improve self-fitting skill acquisition relative to past studies in which printed instruction booklets were used, the majority of people are still likely to require access to support from trained personnel while carrying out the self-fitting procedure, especially when this requires the use of an app.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/aud.0000000000000663","type":"journal-article","created":{"date-parts":[[2018,10,4]],"date-time":"2018-10-04T06:52:34Z","timestamp":1538635954000},"page":"794-804","source":"Crossref","is-referenced-by-count":49,"title":["Factors Associated With Successful Setup of a Self-Fitting Hearing Aid and the Need for Personalized Support"],"prefix":"10.1097","volume":"40","author":[{"given":"Elizabeth","family":"Convery","sequence":"first","affiliation":[{"name":"HEARing Cooperative Research Centre, Australia"},{"name":"Audiology Department, National Acoustic Laboratories, Australia"},{"name":"School of Health and Rehabilitation Sciences, University of Queensland, Australia."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gitte","family":"Keidser","sequence":"additional","affiliation":[{"name":"HEARing Cooperative Research Centre, Australia"},{"name":"Audiology Department, National Acoustic Laboratories, Australia"},{"name":"School of Health and Rehabilitation Sciences, University of Queensland, Australia."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Louise","family":"Hickson","sequence":"additional","affiliation":[{"name":"HEARing Cooperative Research Centre, Australia"},{"name":"School of Health and Rehabilitation Sciences, University of Queensland, Australia."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carly","family":"Meyer","sequence":"additional","affiliation":[{"name":"HEARing Cooperative Research Centre, Australia"},{"name":"School of Health and Rehabilitation Sciences, University of Queensland, Australia."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2019,7]]},"reference":[{"key":"R2-20230726","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1080\/14739879.2009.11493762","article-title":"Teach practical skills.","volume":"20","author":"Allery","year":"2009","journal-title":"Educ Prim Care"},{"key":"R3-20230726","doi-asserted-by":"crossref","first-page":"172","DOI":"10.1097\/AUD.0000000000000477","article-title":"Exploring hearing aid problems: Perspectives of hearing aid owners and clinicians.","volume":"39","author":"Bennett","year":"2018","journal-title":"Ear Hear"},{"key":"R4-20230726","doi-asserted-by":"crossref","first-page":"699","DOI":"10.1097\/PEC.0b013e3182955480","article-title":"Using video discharge instructions as an adjunct to standard written instructions improved caregivers\u2019 understanding of their child\u2019s emergency department visit, plan, and follow-up: A randomized controlled trial.","volume":"29","author":"Bloch","year":"2013","journal-title":"Pediatr Emerg Care"},{"key":"R5-20230726","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1186\/1751-0473-3-17","article-title":"Purposeful selection of variables in logistic regression.","volume":"3","author":"Bursac","year":"2008","journal-title":"Source Code Biol Med"},{"key":"R6-20230726","doi-asserted-by":"crossref","first-page":"302","DOI":"10.1111\/tct.12051","article-title":"Using Gagne\u2019s theory to teach procedural skills.","volume":"10","author":"Buscombe","year":"2013","journal-title":"Clin Teach"},{"key":"R7-20230726","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1097\/AUD.0000000000000221","article-title":"Evaluation of a modified user guide for hearing aid management.","volume":"37","author":"Caposecco","year":"2016","journal-title":"Ear Hear"},{"key":"R8-20230726","doi-asserted-by":"crossref","first-page":"330","DOI":"10.1044\/jshd.2404.330","article-title":"Preferred method for clinical determination of pure-tone thresholds.","volume":"24","author":"Carhart","year":"1959","journal-title":"J Speech Hear Disord"},{"key":"R9-20230726","doi-asserted-by":"crossref","first-page":"408","DOI":"10.3109\/17483107.2014.905642","article-title":"Technology for hearing loss\u2014as we know it, and as we dream it.","volume":"9","author":"Clark","year":"2014","journal-title":"Disabil Rehabil Assist Technol"},{"key":"R10-20230726","doi-asserted-by":"crossref","first-page":"385","DOI":"10.3109\/14992027.2013.773407","article-title":"Hearing-aid assembly management among adults from culturally and linguistically diverse backgrounds: Toward the feasibility of self-fitting hearing aids.","volume":"52","author":"Convery","year":"2013","journal-title":"Int J Audiol"},{"key":"R11-20230726","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1177\/1084713811427707","article-title":"A self-fitting hearing aid: Need and concept.","volume":"15","author":"Convery","year":"2011a","journal-title":"Trends Amplif"},{"key":"R12-20230726","doi-asserted-by":"crossref","first-page":"196","DOI":"10.1177\/1084713811431694","article-title":"Management of hearing aid assembly by urban-dwelling hearing-impaired adults in a developed country: Implications for a self-fitting hearing aid.","volume":"15","author":"Convery","year":"2011b","journal-title":"Trends Amplif"},{"key":"R13-20230726","doi-asserted-by":"crossref","first-page":"109","DOI":"10.3766\/jaaa.15076","article-title":"Evaluation of the self-fitting process with a commercially available hearing aid.","volume":"28","author":"Convery","year":"2017","journal-title":"J Am Acad Audiol"},{"key":"R14-20230726","doi-asserted-by":"crossref","first-page":"5","DOI":"10.3766\/jaaa.26.1.2","article-title":"Factors affecting reliability and validity of self-directed automatic in situ audiometry: implications for self-fitting hearing AIDS.","volume":"26","author":"Convery","year":"2015","journal-title":"J Am Acad Audiol"},{"key":"R15-20230726","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1097\/00003446-200502000-00002","article-title":"Who wants a hearing aid? Personality profiles of hearing aid seekers.","volume":"26","author":"Cox","year":"2005","journal-title":"Ear Hear"},{"key":"R19-20230726","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1097\/AUD.0b013e3181cbc783","article-title":"Guest editorial: Accessible and affordable hearing health care for adults with mild to moderate hearing loss.","volume":"31","author":"Donahue","year":"2010","journal-title":"Ear Hear"},{"key":"R20-20230726","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1097\/AUD.0000000000000237","article-title":"A randomized controlled trial to evaluate the benefits of a multimedia educational program for first-time hearing aid users.","volume":"37","author":"Ferguson","year":"2016","journal-title":"Ear Hear"},{"key":"R21-20230726","doi-asserted-by":"crossref","first-page":"634","DOI":"10.3109\/14992027.2015.1024889","article-title":"Sex-specific predictors of hearing-aid use in older persons: The age, gene\/environment susceptibility - Reykjavik study.","volume":"54","author":"Fisher","year":"2015","journal-title":"Int J Audiol"},{"key":"R22-20230726","doi-asserted-by":"crossref","first-page":"527","DOI":"10.1044\/jslhr.4103.527","article-title":"Hearing loss, control, and demographic factors influencing hearing aid use among older adults.","volume":"41","author":"Garstecki","year":"1998","journal-title":"J Speech Lang Hear Res"},{"key":"R23-20230726","doi-asserted-by":"crossref","first-page":"145","DOI":"10.3138\/cja.27.2.145","article-title":"The effect of hearing loss and hearing aids on the use of information and communication technologies by community-living older adults.","volume":"27","author":"Gonsalves","year":"2008","journal-title":"Can J Aging"},{"issue":"Suppl 1","key":"R25-20230726","doi-asserted-by":"crossref","first-page":"S18","DOI":"10.3109\/14992027.2013.860488","article-title":"Factors associated with success with hearing aids in older adults.","volume":"53","author":"Hickson","year":"2014","journal-title":"Int J Audiol"},{"key":"R26-20230726","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1177\/2331216516643284","article-title":"Self-fitting hearing aids: Status quo and future predictions.","volume":"20","author":"Keidser","year":"2016","journal-title":"Trends in Hearing"},{"key":"R27-20230726","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1080\/2050571X.2015.1117743","article-title":"Assessing the relationship between locus of control and continued hearing aid use: Application of the Origin and Pawn Scales.","volume":"19","author":"Kelly-Campbell","year":"2016","journal-title":"Speech Lang Hear"},{"key":"R29-20230726","doi-asserted-by":"crossref","first-page":"772","DOI":"10.1177\/1073191116654217","article-title":"Changes in Montreal Cognitive Assessment Scores over time.","volume":"24","author":"Krishnan","year":"2017","journal-title":"Assessment"},{"key":"R30-20230726","doi-asserted-by":"crossref","first-page":"593","DOI":"10.1258\/0022215001906480","article-title":"Manual dexterity and successful hearing aid use.","volume":"114","author":"Kumar","year":"2000","journal-title":"J Laryngol Otol"},{"key":"R34-20230726","doi-asserted-by":"crossref","first-page":"695","DOI":"10.1111\/j.1532-5415.2005.53221.x","article-title":"The Montreal Cognitive Assessment, MoCA: A brief screening tool for mild cognitive impairment.","volume":"53","author":"Nasreddine","year":"2005","journal-title":"J Am Geriatr Soc"},{"key":"R36-20230726","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1080\/00223891.1974.10119950","article-title":"A locus of control scale for noncollege as well as college adults.","volume":"38","author":"Nowicki","year":"1974","journal-title":"J Personal Assess"},{"key":"R37-20230726","doi-asserted-by":"crossref","first-page":"673","DOI":"10.1007\/s11135-006-9018-6","article-title":"A caution regarding rules of thumb for variance inflation factors.","volume":"41","author":"O\u2019Brien","year":"2007","journal-title":"Qual Quant"},{"key":"R39-20230726","first-page":"1","article-title":"Notes on the use of data transformations.","volume":"8","author":"Osborne","year":"2002","journal-title":"Pract Assess Res Eval"},{"key":"R40-20230726","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1044\/2015_AJA-14-0093","article-title":"Apps for hearing science and care.","volume":"24","author":"Paglialonga","year":"2015","journal-title":"Am J Audiol"},{"key":"R43-20230726","doi-asserted-by":"crossref","first-page":"752","DOI":"10.1034\/j.1600-051X.1999.t01-8-261101.x","article-title":"Comparison of video and written instructions for plaque removal by an oscillating\/rotating\/reciprocating electric toothbrush.","volume":"26","author":"Renton-Harper","year":"1999","journal-title":"J Clin Periodontol"},{"key":"R44-20230726","doi-asserted-by":"crossref","first-page":"990","DOI":"10.1542\/peds.2009-2916","article-title":"Animated video vs pamphlet: Comparing the success of educating parents about proper antibiotic use.","volume":"125","author":"Schnellinger","year":"2010","journal-title":"Pediatrics"},{"key":"R45-20230726","doi-asserted-by":"crossref","first-page":"S38","DOI":"10.3109\/14992027.2013.847287","article-title":"Exploring the relationship between technology use, hearing help-seeking, and hearing aid outcomes in older adults.","volume":"53 Suppl 1","author":"Stieglitz Ham","year":"2014","journal-title":"Int J Audiol"},{"key":"R47-20230726","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1177\/0829573506295469","article-title":"The Delis-Kaplan executive function system: a review.","volume":"20","author":"Swanson","year":"2005","journal-title":"Canadian J Sch Psychol"},{"key":"R49-20230726","doi-asserted-by":"crossref","first-page":"e0173291","DOI":"10.1371\/journal.pone.0173291","article-title":"Decline in changing Montreal Cognitive Assessment (MoCA) scores is associated with post-stroke cognitive decline determined by a formal neuropsychological evaluation.","volume":"12","author":"Tan","year":"2017","journal-title":"PLoS One"},{"key":"R50-20230726","doi-asserted-by":"crossref","first-page":"623","DOI":"10.1177\/1359105305055304","article-title":"The validity of the multidimensional health locus of control scales.","volume":"10","author":"Wallston","year":"2005","journal-title":"J Health Psychol"},{"key":"R51-20230726","doi-asserted-by":"crossref","first-page":"160","DOI":"10.1177\/109019817800600107","article-title":"Development of the Multidimensional Health Locus of Control (MHLC) scales.","volume":"6","author":"Wallston","year":"1978","journal-title":"Health Educ Monogr"},{"key":"R52-20230726","doi-asserted-by":"crossref","first-page":"759","DOI":"10.1080\/14992020701545898","article-title":"Development of a hearing aid self-efficacy questionnaire.","volume":"46","author":"West","year":"2007","journal-title":"Int J Audiol"}],"container-title":["Ear &amp; Hearing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00003446-201907000-00004","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,7,26]],"date-time":"2023-07-26T08:45:54Z","timestamp":1690361154000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00003446-201907000-00004"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,10,3]]},"references-count":37,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.1097\/aud.0000000000000663","relation":{},"ISSN":["0196-0202"],"issn-type":[{"value":"0196-0202","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,10,3]]}}}