{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,8]],"date-time":"2026-07-08T16:27:47Z","timestamp":1783528067946,"version":"3.55.0"},"reference-count":44,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","license":[{"start":{"date-parts":[[2019,2,21]],"date-time":"2019-02-21T00:00:00Z","timestamp":1550707200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019,9]]},"abstract":"<jats:sec>\n            <jats:title>Objectives:<\/jats:title>\n            <jats:p>The aim of this study was to compare listening effort, as estimated via pupillary response, during a speech-in-noise test in bone-anchored hearing system (BAHS) users wearing three different sound processors. The three processors, Ponto Pro (PP), Ponto 3 (P3), and Ponto 3 SuperPower (P3SP), differ in terms of maximum force output (MFO) and MFO algorithm. The hypothesis was that listeners would allocate lower listening effort with the P3SP than with the PP, as a consequence of a higher MFO and, hence, fewer saturation artifacts in the signal.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Design:<\/jats:title>\n            <jats:p>Pupil dilations were recorded in 21 BAHS users with a conductive or mixed hearing loss, during a speech-in-noise test performed at positive signal-to-noise ratios (SNRs), where the speech and noise levels were individually adjusted to lead to 95% correct intelligibility with the PP. The listeners had to listen to a sentence in noise, retain it for 3\u2009seconds and then repeat it, while an eye-tracking camera recorded their pupil dilation. The three sound processors were tested in random order with a single-blinded experimental design. Two conditions were performed at the same SNR: Condition 1, where the speech level was designed to saturate the PP but not the P3SP, and condition 2, where the overall sound level was decreased relative to condition 1 to reduce saturation artifacts.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>The P3SP led to higher speech intelligibility than the PP in both conditions, while the performance with the P3 did not differ from the performance with the PP and the P3SP. Pupil dilations were analyzed in terms of both peak pupil dilation (PPD) and overall pupil dilation via growth curve analysis (GCA). In condition 1, a significantly lower PPD, indicating a decrease in listening effort, was obtained with the P3SP relative to the PP. The PPD obtained with the P3 did not differ from the PPD obtained with the other two sound processors. In condition 2, no difference in PPD was observed across the three processors. The GCA revealed that the overall pupil dilation was significantly lower, in both conditions, with both the P3SP and the P3 relative to the PP, and, in condition 1, also with the P3SP relative to the P3.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>The overall effort to process a moderate to loud speech signal was significantly reduced by using a sound processor with a higher MFO (P3SP and P3), as a consequence of fewer saturation artifacts. These findings suggest that sound processors with a higher MFO may help BAHS users in their everyday listening scenarios, in particular in noisy environments, by improving sound quality and, thus, decreasing the amount of cognitive resources utilized to process incoming speech sounds.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/aud.0000000000000699","type":"journal-article","created":{"date-parts":[[2019,2,27]],"date-time":"2019-02-27T00:06:14Z","timestamp":1551225974000},"page":"1220-1232","source":"Crossref","is-referenced-by-count":18,"title":["Benefit of Higher Maximum Force Output on Listening Effort in Bone-Anchored Hearing System Users: A Pupillometry Study"],"prefix":"10.1097","volume":"40","author":[{"given":"Federica","family":"Bianchi","sequence":"first","affiliation":[{"name":"Oticon Medical AB, Kongebakken, Sm\u00f8rum, Denmark"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dorothea","family":"Wendt","sequence":"additional","affiliation":[{"name":"Eriksholm Research Center, Oticon A\/S, R\u00f8rtangvej, Snekkersten, Denmark"},{"name":"Hearing Systems Group, Department of Electrical Engineering, Technical University of Denmark, Denmark"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christina","family":"Wassard","sequence":"additional","affiliation":[{"name":"Oticon Medical AB, Kongebakken, Sm\u00f8rum, Denmark"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Patrick","family":"Maas","sequence":"additional","affiliation":[{"name":"Oticon Medical AB, Kongebakken, Sm\u00f8rum, Denmark"},{"name":"Oticon Medical, Karl-Wiechert-Allee, Hannover, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas","family":"Lunner","sequence":"additional","affiliation":[{"name":"Eriksholm Research Center, Oticon A\/S, R\u00f8rtangvej, Snekkersten, Denmark"},{"name":"Hearing Systems Group, Department of Electrical Engineering, Technical University of Denmark, Denmark"},{"name":"Department of Behavioral Sciences and Learning, Link\u00f6ping University, Sweden"},{"name":"Linnaeus Centre HEAD, The Swedish Institute for Disability Research, Link\u00f6ping and \u00d6rebro Universities, Sweden"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tove","family":"Rosenbom","sequence":"additional","affiliation":[{"name":"Oticon Medical AB, Kongebakken, Sm\u00f8rum, Denmark"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marcus","family":"Holmberg","sequence":"additional","affiliation":[{"name":"Oticon Medical AB, Datav\u00e4gen, Askim, Sweden."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2019,9]]},"reference":[{"key":"R1-20240207","doi-asserted-by":"crossref","first-page":"1289","DOI":"10.1126\/science.472746","article-title":"Pupillary responses during information processing vary with Scholastic Aptitude Test scores.","volume":"205","author":"Ahern","year":"1979","journal-title":"Science"},{"key":"R2-20240207","doi-asserted-by":"crossref","first-page":"276","DOI":"10.1037\/0033-2909.91.2.276","article-title":"Task-evoked pupillary responses, processing load, and the structure of processing resources.","volume":"91","author":"Beatty","year":"1982","journal-title":"Psychol Bull"},{"key":"R3-20240207","doi-asserted-by":"crossref","first-page":"116","DOI":"10.1080\/14640746808400139","article-title":"Pupil size and problem solving.","volume":"20","author":"Bradshaw","year":"1968","journal-title":"Q J Exp Psychol"},{"key":"R4-20240207","doi-asserted-by":"crossref","first-page":"2108","DOI":"10.1121\/1.410152","article-title":"An international comparison of long-term average speech spectra.","volume":"96","author":"Byrne","year":"1994","journal-title":"J Acoust Soc Am"},{"key":"R5-20240207","doi-asserted-by":"crossref","first-page":"600","DOI":"10.1097\/AUD.0000000000000028","article-title":"The effect of hearing aid noise reduction on listening effort in hearing-impaired adults.","volume":"35","author":"Desjardins","year":"2014","journal-title":"Ear Hear"},{"key":"R6-20240207","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1044\/jshd.4702.189","article-title":"Effects of hearing and use on speech discrimination and listening effort.","volume":"47","author":"Downs","year":"1982","journal-title":"J Speech Hear Disord"},{"key":"R7-20240207","doi-asserted-by":"crossref","first-page":"35","DOI":"10.3109\/01050398809042178","article-title":"The effect of specific compression settings on phoneme identification in hearing-impaired subjects.","volume":"17","author":"Dreschler","year":"1988","journal-title":"Scand Audiol"},{"key":"R8-20240207","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1037\/0096-1523.28.1.163","article-title":"Does English coronal place assimilation create lexical ambiguity?","volume":"28","author":"Gow","year":"2002","journal-title":"J Exp Psychol Hum Percept Perform"},{"key":"R9-20240207","doi-asserted-by":"crossref","first-page":"573","DOI":"10.1044\/1092-4388(2002\/046)","article-title":"Listening effort and fatigue in school-age children with and without hearing loss.","volume":"45","author":"Hick","year":"2002","journal-title":"J Speech Lang Hear Res"},{"key":"R10-20240207","doi-asserted-by":"crossref","first-page":"521","DOI":"10.1080\/14992027.2017.1302605","article-title":"DSL prescriptive targets for bone conduction devices: Adaptation and comparison to clinical fittings.","volume":"56","author":"Hodgetts","year":"2017","journal-title":"Int J Audiol"},{"key":"R11-20240207","doi-asserted-by":"crossref","first-page":"16","DOI":"10.3758\/BF03204445","article-title":"Pupillary dilation as a measure of attention: A quantitative system analysis.","volume":"25","author":"Hoeks","year":"1993","journal-title":"Behav Res Methods Instrum Comput"},{"key":"R12-20240207","doi-asserted-by":"crossref","first-page":"523","DOI":"10.1097\/AUD.0b013e31828003d8","article-title":"The effects of hearing aid use on listening effort and mental fatigue associated with sustained speech processing demands.","volume":"34","author":"Hornsby","year":"2013","journal-title":"Ear Hear"},{"key":"R13-20240207","doi-asserted-by":"crossref","first-page":"1583","DOI":"10.1126\/science.154.3756.1583","article-title":"Pupil diameter and load on memory.","volume":"154","author":"Kahneman","year":"1966","journal-title":"Science"},{"key":"R14-20240207","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1111\/j.1469-8986.2012.01477.x","article-title":"Pupil size varies with word listening and response selection difficulty in older adults with hearing loss.","volume":"50","author":"Kuchinsky","year":"2013","journal-title":"Psychophysiology"},{"key":"R15-20240207","doi-asserted-by":"crossref","first-page":"1","DOI":"10.18637\/jss.v082.i13","article-title":"lmertest package: Tests in linear mixed effects models.","volume":"82","author":"Kuznetsova","year":"2017","journal-title":"J Stat Softw"},{"key":"R16-20240207","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1097\/00003446-199710000-00003","article-title":"A digital filterbank hearing aid: Three digital signal processing algorithms\u2013user preference and performance.","volume":"18","author":"Lunner","year":"1997","journal-title":"Ear Hear"},{"key":"R17-20240207","doi-asserted-by":"crossref","first-page":"145S","DOI":"10.1097\/AUD.0000000000000294","article-title":"Using speech recall in hearing aid fitting and outcome evaluation under ecological test conditions.","volume":"37 Suppl 1","author":"Lunner","year":"2016","journal-title":"Ear Hear"},{"key":"R18-20240207","doi-asserted-by":"crossref","first-page":"345","DOI":"10.1016\/j.cognition.2015.05.009","article-title":"Anticipatory coarticulation facilitates word recognition in toddlers.","volume":"142","author":"Mahr","year":"2015","journal-title":"Cognition"},{"key":"R20-20240207","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1016\/j.jml.2007.11.006","article-title":"Statistical and computational models of the visual world paradigm: growth curves and individual differences.","volume":"59","author":"Mirman","year":"2008","journal-title":"J Mem Lang"},{"key":"R21-20240207","doi-asserted-by":"crossref","first-page":"202","DOI":"10.3109\/14992027.2010.524254","article-title":"The Danish hearing in noise test.","volume":"50","author":"Nielsen","year":"2011","journal-title":"Int J Audiol"},{"key":"R22-20240207","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1016\/j.heares.2018.05.003","article-title":"Impact of SNR, masker type and noise reduction processing on sentence recognition performance and listening effort as indicated by the pupil dilation response.","volume":"365","author":"Ohlenforst","year":"2018","journal-title":"Hear Res"},{"key":"R23-20240207","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1016\/j.heares.2017.05.012","article-title":"Impact of stimulus-related factors and hearing impairment on listening effort as indicated by pupil dilation.","volume":"351","author":"Ohlenforst","year":"2017","journal-title":"Hear Res"},{"issue":"Suppl 1","key":"R25-20240207","first-page":"1S","article-title":"Eriksholm workshop on hearing impairment and cognitive energy.","volume":"37","author":"Pichora-Fuller","year":"2016","journal-title":"Ear Hear"},{"issue":"Suppl 1","key":"R26-20240207","doi-asserted-by":"crossref","first-page":"5S","DOI":"10.1097\/AUD.0000000000000312","article-title":"Hearing impairment and cognitive energy: The framework for understanding effortful listening (FUEL).","volume":"37","author":"Pichora-Fuller","year":"2016","journal-title":"Ear Hear"},{"key":"R27-20240207","doi-asserted-by":"crossref","first-page":"560","DOI":"10.1111\/j.1469-8986.2009.00947.x","article-title":"Pupillometry as a measure of cognitive effort in younger and older adults.","volume":"47","author":"Piquado","year":"2010","journal-title":"Psychophysiology"},{"key":"R28-20240207","first-page":"79","article-title":"New developments in bone-conduction hearing implants: A review.","volume":"8","author":"Reinfeldt","year":"2015","journal-title":"Med Devices (Auckl)"},{"key":"R29-20240207","doi-asserted-by":"crossref","first-page":"1","DOI":"10.3389\/fnsys.2013.00031","article-title":"The ease of language understanding (ELU) model: Theoretical, empirical, and clinical advances.","volume":"7","author":"R\u00f6nnberg","year":"2013","journal-title":"Front Syst Neurosci"},{"issue":"Suppl 2","key":"R30-20240207","doi-asserted-by":"crossref","first-page":"S99","DOI":"10.1080\/14992020802301167","article-title":"Cognition counts: A working memory system for ease of language understanding (ELU).","volume":"47","author":"R\u00f6nnberg","year":"2008","journal-title":"Int J Audiol"},{"key":"R31-20240207","doi-asserted-by":"crossref","first-page":"1230","DOI":"10.1044\/1092-4388(2009\/08-0111)","article-title":"Objective measures of listening effort: Effects of background noise and noise reduction.","volume":"52","author":"Sarampalis","year":"2009","journal-title":"J Speech Lang Hear Res"},{"key":"R32-20240207","article-title":"DSL for bone anchored hearing devices: Prescriptive targets and verification solutions.","author":"Scollie","year":"2018","journal-title":"Audiology Online"},{"key":"R33-20240207","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1177\/108471380500900402","article-title":"The DSL method for pediatric hearing instrument fitting: Historical perspective and current issues.","volume":"9","author":"Seewald","year":"2005","journal-title":"Trends Amplif"},{"key":"R34-20240207","doi-asserted-by":"crossref","first-page":"183","DOI":"10.3766\/jaaa.26.2.7","article-title":"Estimation of signal-to-noise ratios in realistic sound scenarios.","volume":"26","author":"Smeds","year":"2015","journal-title":"J Am Acad Audiol"},{"key":"R35-20240207","doi-asserted-by":"crossref","first-page":"1894","DOI":"10.3389\/fpsyg.2015.01894","article-title":"Working memory and hearing aid processing: Literature findings, future directions, and clinical applications.","volume":"6","author":"Souza","year":"2015","journal-title":"Front Psychol"},{"key":"R36-20240207","doi-asserted-by":"crossref","first-page":"1654","DOI":"10.1121\/1.2434754","article-title":"Quantifying the effects of fast-acting compression on the envelope of speech.","volume":"121","author":"Stone","year":"2007","journal-title":"J Acoust Soc Am"},{"key":"R37-20240207","doi-asserted-by":"crossref","first-page":"348","DOI":"10.3766\/jaaa.19.4.7","article-title":"Recording and classification of the acoustic environment of hearing aid users.","volume":"19","author":"Wagener","year":"2008","journal-title":"J Am Acad Audiol"},{"key":"R38-20240207","doi-asserted-by":"crossref","first-page":"690","DOI":"10.1097\/AUD.0000000000000454","article-title":"Impact of noise and noise reduction on processing effort: A pupillometry study.","volume":"38","author":"Wendt","year":"2017","journal-title":"Ear Hear"},{"key":"R39-20240207","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1016\/j.heares.2018.05.006","article-title":"Toward a more comprehensive understanding of the impact of masker type and signal-to-noise ratio on the pupillary response while performing a speech-in-noise test.","volume":"369","author":"Wendt","year":"2018","journal-title":"Hear Res"},{"issue":"Suppl 1","key":"R40-20240207","doi-asserted-by":"crossref","first-page":"35S","DOI":"10.1097\/AUD.0000000000000310","article-title":"Evolution of models of working memory and cognitive resources.","volume":"37","author":"Wingfield","year":"2016","journal-title":"Ear Hear"},{"key":"R41-20240207","first-page":"1","article-title":"Rapid release from listening effort resulting from semantic context, and effects of spectral degradation and cochlear implants.","volume":"20","author":"Winn","year":"2016","journal-title":"Trends Hear"},{"key":"R42-20240207","doi-asserted-by":"crossref","first-page":"e153","DOI":"10.1097\/AUD.0000000000000145","article-title":"The impact of auditory spectral resolution on listening effort revealed by pupil dilation.","volume":"36","author":"Winn","year":"2015","journal-title":"Ear Hear"},{"key":"R43-20240207","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1097\/AUD.0000000000000486","article-title":"Characteristics of real-world signal to noise ratios and speech listening situations of older adults with mild to moderate hearing loss.","volume":"39","author":"Wu","year":"2018","journal-title":"Ear Hear"},{"key":"R44-20240207","doi-asserted-by":"crossref","first-page":"480","DOI":"10.1097\/AUD.0b013e3181d4f251","article-title":"Pupil response as an indication of effortful listening: The influence of sentence intelligibility.","volume":"31","author":"Zekveld","year":"2010","journal-title":"Ear Hear"},{"key":"R45-20240207","doi-asserted-by":"crossref","first-page":"498","DOI":"10.1097\/AUD.0b013e31820512bb","article-title":"Cognitive load during speech perception in noise: The influence of age, hearing loss, and cognition on the pupil response.","volume":"32","author":"Zekveld","year":"2011","journal-title":"Ear Hear"},{"key":"R46-20240207","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1097\/MAO.0000000000000258","article-title":"Amplification options for patients with mixed hearing loss.","volume":"35","author":"Zwartenkot","year":"2014","journal-title":"Otol Neurotol"}],"container-title":["Ear &amp; Hearing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/AUD.0000000000000699","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,2,7]],"date-time":"2024-02-07T02:06:17Z","timestamp":1707271577000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/AUD.0000000000000699"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,2,21]]},"references-count":44,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.1097\/aud.0000000000000699","relation":{},"ISSN":["0196-0202"],"issn-type":[{"value":"0196-0202","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,2,21]]}}}