{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T05:07:22Z","timestamp":1790140042280,"version":"4.0.1"},"reference-count":72,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","license":[{"start":{"date-parts":[[2019,10,7]],"date-time":"2019-10-07T00:00:00Z","timestamp":1570406400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"abstract":"<jats:sec>\n            <jats:title>Objectives:<\/jats:title>\n            <jats:p>The aim of this study was to determine electric-acoustic masking in cochlear implant users with ipsilateral residual hearing and different electrode insertion depths and to investigate the influence on speech reception. The effects of different fitting strategies\u2014meet, overlap, and a newly developed masking adjusted fitting (UNMASKfit)\u2014on speech reception are compared. If electric-acoustic masking has a detrimental effect on speech reception, the individualized UNMASKfit map might be able to reduce masking and thereby enhance speech reception.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Design:<\/jats:title>\n            <jats:p>Fifteen experienced MED-EL Flex electrode recipients with ipsilateral residual hearing participated in a crosssover design study using three fitting strategies for 4 weeks each. The following strategies were compared: (1) a meet fitting, dividing the frequency range between electric and acoustic stimulation, (2) an overlap fitting, delivering part of the frequency range both acoustically and electrically, and (3) the UNMASKfit, reducing the electric stimulation according to the individual electric-on-acoustic masking strength. A psychoacoustic masking procedure was used to measure the changes in acoustic thresholds due to the presence of electric maskers. Speech reception was measured in noise with the Oldenburg Matrix Sentence test.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Behavioral thresholds of acoustic probe tones were significantly elevated in the presence of electric maskers. A maximum of masking was observed when the difference in location between the electric and acoustic stimulation was around one octave in place frequency. Speech reception scores and strength of masking showed a dependency on residual hearing, and speech reception was significantly reduced in the overlap fitting strategy. Electric- acoustic stimulation significantly improved speech reception over electric stimulation alone, with a tendency toward a larger benefit with the UNMASKfit map. In addition, masking was significantly inversely correlated to the speech reception performance difference between the overlap and the meet fitting.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>(1) This study confirmed the interaction between ipsilateral electric and acoustic stimulation in a psychoacoustic masking experiment. (2) The overlap fitting yielded poorer speech reception performance in stationary noise especially in subjects with strong masking. (3) The newly developed UNMASKfit strategy yielded similar speech reception thresholds with an enhanced acoustic benefit, while at the same time reducing the electric stimulation. This could be beneficial in the long-term if applied as a standard fitting, as hair cells are exposed to less possibly adverse electric stimulation. In this study, the UNMASKfit allowed the participants a better use of their natural hearing even after 1 month of adaptation. It might be feasible to transfer these results to the clinic, by fitting patients with the UNMASKfit upon their first fitting appointment, so that longer adaptation times can further improve speech reception.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/aud.0000000000000807","type":"journal-article","created":{"date-parts":[[2019,10,8]],"date-time":"2019-10-08T16:14:14Z","timestamp":1570551254000},"page":"868-882","source":"Crossref","is-referenced-by-count":33,"title":["Interaction Between Electric and Acoustic Stimulation Influences Speech Perception in Ipsilateral EAS Users"],"prefix":"10.1097","volume":"41","author":[{"given":"Marina","family":"Imsiecke","sequence":"first","affiliation":[{"name":"Department of Otorhinolaryngology, Hanover Medical School, Hannover, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Benjamin","family":"Kr\u00fcger","sequence":"additional","affiliation":[{"name":"Department of Otorhinolaryngology, Hanover Medical School, Hannover, Germany"},{"name":"Cluster of Excellence \u2018Hearing4all,' Hanover, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andreas","family":"B\u00fcchner","sequence":"additional","affiliation":[{"name":"Department of Otorhinolaryngology, Hanover Medical School, Hannover, Germany"},{"name":"Cluster of Excellence \u2018Hearing4all,' Hanover, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas","family":"Lenarz","sequence":"additional","affiliation":[{"name":"Department of Otorhinolaryngology, Hanover Medical School, Hannover, Germany"},{"name":"Cluster of Excellence \u2018Hearing4all,' Hanover, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Waldo","family":"Nogueira","sequence":"additional","affiliation":[{"name":"Department of Otorhinolaryngology, Hanover Medical School, Hannover, Germany"},{"name":"Cluster of Excellence \u2018Hearing4all,' Hanover, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2020,7]]},"reference":[{"key":"R1-20230812","doi-asserted-by":"crossref","first-page":"374","DOI":"10.1016\/j.otohns.2006.05.002","article-title":"Impact of electrode insertion depth on intracochlear trauma.","volume":"135","author":"Adunka","year":"2006","journal-title":"Otolaryngol Head Neck Surg"},{"key":"R2-20230812","doi-asserted-by":"crossref","first-page":"313","DOI":"10.1159\/000103212","article-title":"Cochlear implant channel separation and its influence on speech perception\u2013implications for a new electrode design.","volume":"12","author":"Arnoldner","year":"2007a","journal-title":"Audiol Neurootol"},{"key":"R3-20230812","doi-asserted-by":"crossref","first-page":"1298","DOI":"10.1080\/00016480701275261","article-title":"Speech and music perception with the new fine structure speech coding strategy: Preliminary results.","volume":"127","author":"Arnoldner","year":"2007b","journal-title":"Acta Otolaryngol"},{"key":"R4-20230812","doi-asserted-by":"crossref","first-page":"468","DOI":"10.1097\/AUD.0b013e31820dd3f0","article-title":"The effect of different cochlear implant microphones on acoustic hearing individuals' binaural benefits for speech perception in noise.","volume":"32","author":"Aronoff","year":"2011","journal-title":"Ear Hear"},{"key":"R7-20230812","doi-asserted-by":"crossref","first-page":"1773","DOI":"10.1097\/MAO.0000000000000541","article-title":"Influence of cochlear implant insertion depth on performance: A prospective randomized trial.","volume":"35","author":"Buchman","year":"2014","journal-title":"Otol Neurotol"},{"key":"R8-20230812","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1159\/000206490","article-title":"Impact of low-frequency hearing.","volume":"14","author":"B\u00fcchner","year":"2009","journal-title":"Audiol Neurotol"},{"key":"R9-20230812","doi-asserted-by":"crossref","first-page":"e0174900","DOI":"10.1371\/journal.pone.0174900","article-title":"Investigation of the effect of cochlear implant electrode length on speech comprehension in quiet and noise compared with the results with users of electro-acoustic-stimulation, a retrospective analysis.","volume":"12","author":"B\u00fcchner","year":"2017","journal-title":"PLoS One"},{"key":"R10-20230812","doi-asserted-by":"crossref","first-page":"194","DOI":"10.1179\/1754762811Y0000000009","article-title":"Clinical evaluation of cochlear implant sound coding taking into account conjectural masking functions, MP3000\u2122.","volume":"12","author":"Buechner","year":"2011","journal-title":"Cochlear Implants Int"},{"key":"R11-20230812","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1016\/j.heares.2006.12.004","article-title":"Does cochlear implantation and electrical stimulation affect residual hair cells and spiral ganglion neurons?","volume":"225","author":"Coco","year":"2007","journal-title":"Hear Res"},{"key":"R12-20230812","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1038\/320065a0","article-title":"Structural alteration of hair cells in the contralateral ear resulting from extracochlear electrical stimulation.","volume":"320","author":"Dodson","year":"1986","journal-title":"Nature"},{"key":"R13-20230812","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1097\/00003446-200508000-00001","article-title":"Acoustic simulations of combined electric and acoustic hearing (EAS).","volume":"26","author":"Dorman","year":"2005","journal-title":"Ear Hear"},{"key":"R14-20230812","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1159\/000111782","article-title":"The benefits of combining acoustic and electric stimulation for the recognition of speech, voice and melodies.","volume":"13","author":"Dorman","year":"2008","journal-title":"Audiol Neurootol"},{"key":"R15-20230812","doi-asserted-by":"crossref","first-page":"148","DOI":"10.3109\/00206090109073110","article-title":"ICRA noises: Artificial noise signals with speech-like spectral and temporal properties for hearing instrument assessment. International Collegium for Rehabilitative Audiology.","volume":"40","author":"Dreschler","year":"2001","journal-title":"Audiology"},{"key":"R16-20230812","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1002\/ar.a.20305","article-title":"Cochlear implantation trauma and noise-induced hearing loss: Apoptosis and therapeutic strategies.","volume":"288","author":"Eshraghi","year":"2006","journal-title":"Anat Rec A Discov Mol Cell Evol Biol"},{"key":"R17-20230812","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1044\/2015_JSLHR-H-15-0247","article-title":"Effects of removing low-frequency electric information on speech perception with bimodal hearing.","volume":"59","author":"Fowler","year":"2016","journal-title":"J Speech Lang Hear Res"},{"key":"R18-20230812","doi-asserted-by":"crossref","first-page":"624","DOI":"10.1097\/01.mao.0000226289.04048.0f","article-title":"Residual hearing conservation and electroacoustic stimulation with the nucleus 24 contour advance cochlear implant.","volume":"27","author":"Fraysse","year":"2006","journal-title":"Otol Neurotol"},{"key":"R19-20230812","doi-asserted-by":"crossref","first-page":"1664","DOI":"10.1121\/1.1502901","article-title":"Perceptual learning following changes in the frequency-to-electrode assignment with the Nucleus-22 cochlear implant.","volume":"112","author":"Fu","year":"2002","journal-title":"J Acoust Soc Am"},{"key":"R20-20230812","doi-asserted-by":"crossref","first-page":"344","DOI":"10.1080\/00016480410016423","article-title":"Combining acoustic and electrical speech processing: Iowa\/Nucleus hybrid implant.","volume":"124","author":"Gantz","year":"2004","journal-title":"Acta Otolaryngol"},{"key":"R21-20230812","doi-asserted-by":"crossref","first-page":"796","DOI":"10.1097\/01.MLG.0000157695.07536.D2","article-title":"Preservation of hearing in cochlear implant surgery: Advantages of combined electrical and acoustical speech processing.","volume":"115","author":"Gantz","year":"2005","journal-title":"Laryngoscope"},{"key":"R22-20230812","doi-asserted-by":"crossref","first-page":"413","DOI":"10.1097\/AUD.0b013e31827e8163","article-title":"Cochlear implantation with hearing preservation yields significant benefit for speech recognition in complex listening environments.","volume":"34","author":"Gifford","year":"2013","journal-title":"Ear Hear"},{"key":"R23-20230812","doi-asserted-by":"crossref","first-page":"539","DOI":"10.1097\/AUD.0000000000000418","article-title":"Combined electric and acoustic stimulation with hearing preservation: Effect of cochlear implant low-frequency cutoff on speech understanding and perceived listening difficulty.","volume":"38","author":"Gifford","year":"2017","journal-title":"Ear Hear"},{"key":"R24-20230812","doi-asserted-by":"crossref","first-page":"348","DOI":"10.1080\/00016480410016432","article-title":"Hearing preservation in cochlear implantation for electric acoustic stimulation.","volume":"124","author":"Gstoettner","year":"2004","journal-title":"Acta Otolaryngol"},{"key":"R25-20230812","doi-asserted-by":"crossref","first-page":"968","DOI":"10.1080\/00016480701805471","article-title":"Electric acoustic stimulation of the auditory system: Results of a multi-centre investigation.","volume":"128","author":"Gstoettner","year":"2008","journal-title":"Acta Otolaryngol"},{"key":"R26-20230812","doi-asserted-by":"crossref","first-page":"1182","DOI":"10.1080\/00016480600672683","article-title":"Effect of deep insertion of the cochlear implant electrode array on pitch estimation and speech perception.","volume":"126","author":"Hamzavi","year":"2006","journal-title":"Acta Otolaryngol"},{"key":"R27-20230812","doi-asserted-by":"crossref","first-page":"895","DOI":"10.3109\/14992027.2014.938368","article-title":"Investigation of a matrix sentence test in noise: Reproducibility and discrimination function in cochlear implant patients.","volume":"53","author":"Hey","year":"2014","journal-title":"Int J Audiol"},{"key":"R28-20230812","first-page":"612","article-title":"Deep electrode insertion in cochlear implants: Apical morphology, electrodes and speech perception results.","volume":"123","author":"Hochmair","year":"2003","journal-title":"Acta Otolaryngol"},{"key":"R29-20230812","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1016\/j.heares.2013.09.014","article-title":"ECAP spread of excitation with virtual channels and physical electrodes.","volume":"306","author":"Hughes","year":"2013","journal-title":"Hear Res"},{"key":"R30-20230812","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1016\/j.heares.2018.04.003","article-title":"Electric-acoustic forward masking in cochlear implant users with ipsilateral residual hearing.","volume":"364","author":"Imsiecke","year":"2018","journal-title":"Hear Res"},{"key":"R31-20230812","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1177\/1084713813480857","article-title":"A systematic review of electric-acoustic stimulation: Device fitting ranges, outcomes, and clinical fitting practices.","volume":"17","author":"Incerti","year":"2013","journal-title":"Trends Amplif"},{"key":"R32-20230812","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1097\/AUD.0b013e318269ce87","article-title":"Optimizing the combination of acoustic and electric hearing in the implanted ear.","volume":"34","author":"Karsten","year":"2013","journal-title":"Ear Hear"},{"key":"R33-20230812","doi-asserted-by":"crossref","first-page":"272","DOI":"10.1080\/00016480310000755a","article-title":"Conservation of low-frequency hearing in cochlear implantation.","volume":"124","author":"Kiefer","year":"2004","journal-title":"Acta Otolaryngol"},{"key":"R34-20230812","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1159\/000084023","article-title":"Combined electric and acoustic stimulation of the auditory system: Results of a clinical study.","volume":"10","author":"Kiefer","year":"2005","journal-title":"Audiol Neurootol"},{"key":"R35-20230812","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1016\/j.heares.2017.12.019","article-title":"Perceptual changes with monopolar and phantom electrode stimulation.","volume":"359","author":"Klawitter","year":"2018","journal-title":"Hear Res"},{"key":"R36-20230812","doi-asserted-by":"crossref","first-page":"337","DOI":"10.3389\/fnins.2017.00337","article-title":"Feasibility of using electrocochleography for objective estimation of electro-acoustic interactions in cochlear implant recipients with residual hearing.","volume":"11","author":"Koka","year":"2017","journal-title":"Front Neurosci"},{"key":"R37-20230812","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1016\/j.heares.2017.06.014","article-title":"Simultaneous masking between electric and acoustic stimulation in cochlear implant users with residual low-frequency hearing.","volume":"353","author":"Kr\u00fcger","year":"2017","journal-title":"Hear Res"},{"key":"R38-20230812","article-title":"(under review). Electric acoustic interaction measurements in cochlear implant users with ipsilateral residual hearing using electrocochleography.","author":"Kr\u00fcger","journal-title":"J Acoust Soc Am"},{"issue":"Suppl 1","key":"R39-20230812","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1159\/000206492","article-title":"Hearing conservation surgery using the Hybrid-L electrode. Results from the first clinical trial at the Medical University of Hannover.","volume":"14","author":"Lenarz","year":"2009","journal-title":"Audiol Neurootol"},{"key":"R40-20230812","doi-asserted-by":"crossref","first-page":"e326","DOI":"10.1097\/MAO.0000000000002127","article-title":"Individual hearing preservation cochlear implantation using the concept of partial insertion.","volume":"40","author":"Lenarz","year":"2019","journal-title":"Otol Neurotol"},{"key":"R41-20230812","doi-asserted-by":"crossref","first-page":"858","DOI":"10.1121\/1.3605294","article-title":"Ipsilateral masking between acoustic and electric stimulations.","volume":"130","author":"Lin","year":"2011","journal-title":"J Acoust Soc Am"},{"key":"R42-20230812","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1007\/s10162-010-0248-x","article-title":"Extending the limits of place and temporal pitch perception in cochlear implant users.","volume":"12","author":"Macherey","year":"2011","journal-title":"J Assoc Res Otolaryngol"},{"key":"R43-20230812","doi-asserted-by":"crossref","first-page":"279","DOI":"10.3109\/14992027.2010.537378","article-title":"Comparison of the fine structure processing (FSP) strategy and the CIS strategy used in the MED-EL cochlear implant system: Speech intelligibility and music sound quality.","volume":"50","author":"Magnusson","year":"2011","journal-title":"Int J Audiol"},{"issue":"4 Pt 1","key":"R44-20230812","doi-asserted-by":"crossref","first-page":"2054","DOI":"10.1121\/1.1558378","article-title":"A practical method of predicting the loudness of complex electrical stimuli.","volume":"113","author":"McKay","year":"2003","journal-title":"J Acoust Soc Am"},{"key":"R45-20230812","doi-asserted-by":"crossref","first-page":"961","DOI":"10.1121\/1.1531983","article-title":"Understanding speech in modulated interference: Cochlear implant users and normal-hearing listeners.","volume":"113","author":"Nelson","year":"2003","journal-title":"J Acoust Soc Am"},{"key":"R46-20230812","first-page":"3044","article-title":"A psychoacoustic NofM-type speech coding strategy for cochlear implants.","volume":"18","author":"Nogueira","year":"2005","journal-title":"EURASIP J Appl Signal Process"},{"key":"R47-20230812","doi-asserted-by":"crossref","first-page":"e0120148","DOI":"10.1371\/journal.pone.0120148","article-title":"Design and evaluation of a cochlear implant strategy based on a \u201cPhantom\u201d channel.","volume":"10","author":"Nogueira","year":"2015","journal-title":"PLoS One"},{"key":"R48-20230812","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1016\/j.heares.2004.10.001","article-title":"Effects of acoustic noise on the auditory nerve compound action potentials evoked by electric pulse trains.","volume":"202","author":"Nourski","year":"2005","journal-title":"Hear Res"},{"key":"R50-20230812","doi-asserted-by":"crossref","first-page":"2352","DOI":"10.1002\/lary.26467","article-title":"Insertion depth impacts speech perception and hearing preservation for lateral wall electrodes.","volume":"127","author":"O'Connell","year":"2017","journal-title":"Laryngoscope"},{"key":"R51-20230812","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1016\/j.heares.2016.01.002","article-title":"Reduction in spread of excitation from current focusing at multiple cochlear locations in cochlear implant users.","volume":"333","author":"Padilla","year":"2016","journal-title":"Hear Res"},{"key":"R52-20230812","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1016\/j.heares.2015.08.018","article-title":"Delayed loss of hearing after hearing preservation cochlear implantation: Human temporal bone pathology and implications for etiology.","volume":"333","author":"Quesnel","year":"2016","journal-title":"Hear Res"},{"key":"R53-20230812","doi-asserted-by":"crossref","first-page":"385","DOI":"10.1044\/1092-4388(2008\/07-0219)","article-title":"The effect of temporal gap identification on speech perception by users of cochlear implants.","volume":"52","author":"Sagi","year":"2009","journal-title":"J Speech Lang Hear Res"},{"key":"R54-20230812","doi-asserted-by":"crossref","first-page":"693","DOI":"10.1097\/AUD.0b013e3181e1d15e","article-title":"Use of \u201cphantom electrode\u201d technique to extend the range of pitches available through a cochlear implant.","volume":"31","author":"Saoji","year":"2010","journal-title":"Ear Hear"},{"key":"R55-20230812","doi-asserted-by":"crossref","first-page":"e215","DOI":"10.1097\/MAO.0000000000001428","article-title":"Physiological mechanisms in combined electric-acoustic stimulation.","volume":"38","author":"Sato","year":"2017","journal-title":"Otol Neurotol"},{"key":"R56-20230812","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1016\/0378-5955(85)90005-X","article-title":"Threshold and loudness functions for pulsatile stimulation of cochlear implants.","volume":"18","author":"Shannon","year":"1985","journal-title":"Hear Res"},{"key":"R57-20230812","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1159\/000357588","article-title":"The benefits of bimodal hearing: Effect of frequency region and acoustic bandwidth.","volume":"19","author":"Sheffield","year":"2014","journal-title":"Audiol Neurootol"},{"key":"R58-20230812","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1080\/14992020802452184","article-title":"Comparison of two frequency-to-electrode maps for acoustic-electric stimulation.","volume":"48","author":"Simpson","year":"2009","journal-title":"Int J Audiol"},{"key":"R59-20230812","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1080\/00016480500488917","article-title":"Preservation of low frequency hearing in partial deafness cochlear implantation (PDCI) using the round window surgical approach.","volume":"127","author":"Skarzynski","year":"2007","journal-title":"Acta Otolaryngol"},{"key":"R60-20230812","doi-asserted-by":"crossref","first-page":"220","DOI":"10.1007\/s10162-007-0076-9","article-title":"Frequency map for the human cochlear spiral ganglion: Implications for cochlear implants.","volume":"8","author":"Stakhovskaya","year":"2007","journal-title":"J Assoc Res Otolaryngol"},{"key":"R61-20230812","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1016\/j.heares.2009.10.004","article-title":"Suppression of the acoustically evoked auditory-nerve response by electrical stimulation in the cochlea of the guinea pig.","volume":"259","author":"Stronks","year":"2010","journal-title":"Hear Res"},{"key":"R62-20230812","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1016\/j.heares.2010.10.012","article-title":"Effects of electrical stimulation on the acoustically evoked auditory-nerve response in guinea pigs with a high-frequency hearing loss.","volume":"272","author":"Stronks","year":"2011","journal-title":"Hear Res"},{"key":"R63-20230812","doi-asserted-by":"crossref","first-page":"1535","DOI":"10.1097\/MAO.0b013e318271c0b6","article-title":"Spatial overlap of combined electroacoustic stimulation determines the electrically evoked response in the guinea pig cochlea.","volume":"33","author":"Stronks","year":"2012","journal-title":"Otol Neurotol"},{"key":"R64-20230812","doi-asserted-by":"crossref","first-page":"1006","DOI":"10.1097\/MAO.0000000000001110","article-title":"The impact of electrode array length on hearing preservation in cochlear implantation.","volume":"37","author":"Suhling","year":"2016","journal-title":"Otol Neurotol"},{"key":"R65-20230812","doi-asserted-by":"crossref","first-page":"e0206435","DOI":"10.1371\/journal.pone.0206435","article-title":"Patient specific selection of lateral wall cochlear implant electrodes based on anatomical indication ranges.","volume":"13","author":"Timm","year":"2018","journal-title":"PLoS One"},{"key":"R66-20230812","doi-asserted-by":"crossref","first-page":"1729","DOI":"10.1121\/1.1687425","article-title":"Speech recognition in noise for cochlear implant listeners: Benefits of residual acoustic hearing.","volume":"115","author":"Turner","year":"2004","journal-title":"J Acoust Soc Am"},{"key":"R67-20230812","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1179\/1754762812Y.0000000008","article-title":"Combined electric and acoustic hearing performance with Zebra\u00ae speech processor: Speech reception, place, and temporal coding evaluation.","volume":"14","author":"Vaerenberg","year":"2013","journal-title":"Cochlear Implants Int"},{"key":"R68-20230812","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1159\/000448581","article-title":"Comparison of the HiFocus Mid-Scala and HiFocus 1J Electrode Array: Angular insertion depths and speech perception outcomes.","volume":"21","author":"van der Jagt","year":"2016","journal-title":"Audiol Neurootol"},{"key":"R69-20230812","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1097\/AUD.0b013e31815d6326","article-title":"The influence of different speech processor and hearing aid settings on speech perception outcomes in electric acoustic stimulation patients.","volume":"29","author":"Vermeire","year":"2008","journal-title":"Ear Hear"},{"key":"R70-20230812","doi-asserted-by":"crossref","first-page":"334","DOI":"10.1159\/000027695","article-title":"Electric-acoustic stimulation of the auditory system. New technology for severe hearing loss.","volume":"61","author":"von Ilberg","year":"1999","journal-title":"ORL J Otorhinolaryngol Relat Spec"},{"key":"R71-20230812","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1080\/14992020500057517","article-title":"Sentence intelligibility in noise for listeners with normal hearing and hearing impairment: Influence of measurement procedure and masking parameters.","volume":"44","author":"Wagener","year":"2005","journal-title":"Int J Audiol"},{"key":"R72-20230812","first-page":"4","article-title":"Development and evaluation of a german sentence test I: Design of the Oldenburg Sentence test.","volume":"38","author":"Wagener","year":"1999","journal-title":"Zeitschrift F\u00fcr Audiologie"},{"key":"R73-20230812","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1097\/AUD.0b013e3181b7190c","article-title":"Information from the voice fundamental frequency (F0) region accounts for the majority of the benefit when acoustic stimulation is added to electric stimulation.","volume":"31","author":"Zhang","year":"2010a","journal-title":"Ear Hear"},{"key":"R74-20230812","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1097\/AUD.0b013e3181c4758d","article-title":"Frequency overlap between electric and acoustic stimulation and speech-perception benefit in patients with combined electric and acoustic stimulation.","volume":"31","author":"Zhang","year":"2010b","journal-title":"Ear Hear"},{"key":"R75-20230812","doi-asserted-by":"crossref","first-page":"295","DOI":"10.3109\/14992027.2015.1128124","article-title":"The effect of fluctuating maskers on speech understanding of high-performing cochlear implant users.","volume":"55","author":"Zirn","year":"2016","journal-title":"Int J Audiol"}],"container-title":["Ear &amp; Hearing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/AUD.0000000000000807","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,12]],"date-time":"2023-08-12T08:05:05Z","timestamp":1691827505000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/AUD.0000000000000807"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,10,7]]},"references-count":72,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/aud.0000000000000807","relation":{},"ISSN":["0196-0202"],"issn-type":[{"value":"0196-0202","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,10,7]]}}}