{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,8]],"date-time":"2025-12-08T22:26:39Z","timestamp":1765232799361},"reference-count":53,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"abstract":"<jats:sec>\n            <jats:title>Objectives:<\/jats:title>\n            <jats:p>to characterize differences in wideband power reflectance for ears with and without cochlear implants (CIs), to describe electrically evoked stapedial reflex (eSR)-induced changes in reflectance, and to evaluate the benefit of a broadband probe for reflex threshold determination for CI recipients. It was hypothesized that reflectance patterns in ears with CIs would be consistent with increased middle ear stiffness and that reflex thresholds measured with a broadband probe would be lower compared with thresholds obtained with a single-frequency probe.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Design:<\/jats:title>\n            <jats:p>Eleven CI recipients participated in both wideband reflectance and eSR testing. Ipsilateral reflexes were measured with three probes: a broadband chirp (swept from 200 to 8000 Hz), a 226 Hz tone, and a 678 Hz tone. Wideband reflectance measures acquired from 28 adults without CIs and with normal middle ear function served as a normative data set for comparison.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Considering the group data, average reflectance was significantly greater for ears with CIs across 250 to 891 Hz and 4238 to 4490 Hz compared with the normative data set, although individual reflectance curves were variable. Some CI recipients also had low 226 Hz admittance, which contributed to the group finding, considering the control group had clinically normal 226 Hz admittance by design. Electrically evoked stapedial reflexes were measurable in nine of 14 ears (64.3%) and in 24 of 46 electrodes (52.5%) tested. Reflex-induced changes in reflectance patterns were unique to the participant\/ear, but similar across activators (electrodes) within a given ear. In addition, reflectance values at or above 1000 Hz were affected most by activating the stapedial reflex, even in ears with clinically normal 226 Hz admittance. This is a higher-frequency range than has been reported for acoustically evoked reflex-induced reflectance changes and is consistent with increased middle ear stiffness at rest. Electrically evoked reflexes could be measured more often with the 678 Hz or the broadband probe compared with the 226 Hz probe tone. Although reflex thresholds were lower with the broadband probe compared with the 678 Hz probe in 16 of 24 conditions, this was not a statistically significant finding (Wilcoxon signed-rank test; <jats:italic toggle=\"yes\">p<\/jats:italic> = 0.072).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>The applications of wideband acoustic immittance measurements (reflectance and reflexes) should also be considered for ears with CIs. Further work is needed to describe changes across time in ears with CIs to more fully understand the reflectance pattern indicating increased middle ear stiffness and to optimize measuring eSRs with a broadband probe.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/aud.0000000000000810","type":"journal-article","created":{"date-parts":[[2019,11,4]],"date-time":"2019-11-04T19:36:54Z","timestamp":1572896214000},"page":"883-895","source":"Crossref","is-referenced-by-count":17,"title":["Wideband Acoustic Immittance in Cochlear Implant Recipients: Reflectance and Stapedial Reflexes"],"prefix":"10.1097","volume":"41","author":[{"given":"Rachel A.","family":"Scheperle","sequence":"first","affiliation":[{"name":"Audiology, St. Louis Children\u2019s Hospital, St. Louis, Missouri, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joshua J.","family":"Hajicek","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan, USA."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2020,7]]},"reference":[{"key":"R1-20230812","doi-asserted-by":"crossref","first-page":"441","DOI":"10.3766\/jaaa.25.5.3","article-title":"Intrasubject variability in power reflectance.","volume":"25","author":"Abur","year":"2014","journal-title":"J Am Acad Audiol"},{"key":"R2-20230812","first-page":"49","article-title":"The relationship between the electrical stapedial muscle reflex threshold and electrical and behavioral measures in cochlear implant patients.","volume":"32","author":"Asal","year":"2016","journal-title":"J Speech Lang Hear Res"},{"key":"R3-20230812","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1177\/00034894991080S406","article-title":"Surgical technique for the CLARION cochlear implant.","volume":"177","author":"Balkany","year":"1999","journal-title":"Ann Otol Rhinol Laryngol Suppl"},{"key":"R4-20230812","doi-asserted-by":"crossref","first-page":"370","DOI":"10.1097\/00003446-199010000-00008","article-title":"Electrically elicited stapedius reflex in cochlear implant patients.","volume":"11","author":"Battmer","year":"1990","journal-title":"Ear Hear"},{"key":"R5-20230812","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1097\/AUD.0b013e3181c00eae","article-title":"Wideband reflectance in normal Caucasian and Chinese school-aged children and in children with otitis media with effusion.","volume":"31","author":"Beers","year":"2010","journal-title":"Ear Hear"},{"key":"R6-20230812","doi-asserted-by":"crossref","first-page":"963","DOI":"10.1001\/archotol.127.8.963","article-title":"Measurement of comfort levels by means of electrical stapedial reflex in children.","volume":"127","author":"Bresnihan","year":"2001","journal-title":"Arch Otolaryngol Head Neck Surg"},{"key":"R7-20230812","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1002\/cii.18","article-title":"Investigations into electrically evoked stapedius reflex measures and subjective loudness percepts in the MED-EL COMBI 40+ cochlear implant.","volume":"6","author":"Brickley","year":"2005","journal-title":"Cochlear Implants Int"},{"key":"R8-20230812","doi-asserted-by":"crossref","first-page":"533","DOI":"10.1097\/AUD.0b013e3181d86b3d","article-title":"Influence of calibration method on distortion-product otoacoustic emission measurements: I. Test performance.","volume":"31","author":"Burke","year":"2010","journal-title":"Ear Hear"},{"key":"R9-20230812","first-page":"637","article-title":"Optimizing fitting in children using objective measures such as neural response imaging and electrically evoked stapedius reflex threshold.","volume":"28","author":"Caner","year":"2007","journal-title":"Otol Neurotol"},{"key":"R10-20230812","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1044\/2014_AJA-14-0018","article-title":"Conductive component after cochlear implantation in patients with residual hearing conservation.","volume":"23","author":"Chole","year":"2014","journal-title":"Am J Audiol"},{"issue":"3 Pt 1","key":"R11-20230812","doi-asserted-by":"crossref","first-page":"214","DOI":"10.1016\/S0194-5998(97)70176-1","article-title":"Cochlear implant soft surgery: Fact or fantasy?","volume":"117","author":"Cohen","year":"1997","journal-title":"Otolaryngol Head Neck Surg"},{"key":"R12-20230812","doi-asserted-by":"crossref","first-page":"104","DOI":"10.1159\/000013827","article-title":"The effects of amplitude modulation on acoustic reflex decay.","volume":"4","author":"Cook","year":"1999","journal-title":"Audiol Neurootol"},{"key":"R13-20230812","doi-asserted-by":"crossref","first-page":"723","DOI":"10.1017\/S0022215109004290","article-title":"Effect of cochlear implant electrode insertion on middle-ear function as measured by intra-operative laser Doppler vibrometry.","volume":"123","author":"Donnelly","year":"2009","journal-title":"J Laryngol Otol"},{"issue":"Suppl 1","key":"R14-20230812","first-page":"1S","article-title":"Eriksholm Workshop: Wideband Absorbance Measures of the Middle Ear.","volume":"34","year":"2013","journal-title":"Ear Hear"},{"key":"R15-20230812","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1016\/j.anorl.2013.05.005","article-title":"Cochlear implant complications in 403 patients: Comparative study of adults and children and review of the literature.","volume":"131","author":"Farinetti","year":"2014","journal-title":"Eur Ann Otorhinolaryngol Head Neck Dis"},{"key":"R16-20230812","doi-asserted-by":"crossref","first-page":"1029","DOI":"10.1044\/jslhr.4205.1029","article-title":"Acoustic reflex detection using wide-band acoustic reflectance, admittance, and power measurements.","volume":"42","author":"Feeney","year":"1999","journal-title":"J Speech Lang Hear Res"},{"key":"R17-20230812","doi-asserted-by":"crossref","first-page":"220","DOI":"10.1179\/1754762811Y.0000000022","article-title":"Toward a method for programming balanced bilateral cochlear implant stimulation levels in children.","volume":"13","author":"Gordon","year":"2012","journal-title":"Cochlear Implants Int"},{"key":"R18-20230812","doi-asserted-by":"crossref","first-page":"447","DOI":"10.1097\/01.aud.0000146178.84065.b3","article-title":"Toward a battery of behavioral and objective measures to achieve optimal cochlear implant stimulation levels in children.","volume":"25","author":"Gordon","year":"2004","journal-title":"Ear Hear"},{"key":"R19-20230812","doi-asserted-by":"crossref","first-page":"1554","DOI":"10.1097\/MAO.0000000000000838","article-title":"Cochlear implant electrode effect on sound energy transfer within the cochlea during acoustic stimulation.","volume":"36","author":"Greene","year":"2015","journal-title":"Otol Neurotol"},{"key":"R20-20230812","doi-asserted-by":"crossref","first-page":"732","DOI":"10.1097\/AUD.0000000000000656","article-title":"Effect of probe-tone frequency on ipsilateral and contralateral electrical stapedius reflex measurement in children with cochlear implants.","volume":"40","author":"Hernandez","year":"2018","journal-title":"Ear Hear"},{"issue":"3 Pt 1","key":"R21-20230812","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1016\/S0194-5998(97)70183-9","article-title":"Electrical middle ear muscle reflex: Use in cochlear implant programming.","volume":"117","author":"Hodges","year":"1997","journal-title":"Otolaryngol Head Neck Surg"},{"key":"R22-20230812","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1177\/00034894991080S413","article-title":"Using electrically evoked auditory reflex thresholds to fit the CLARION cochlear implant.","volume":"108","author":"Hodges","year":"1999","journal-title":"Ann Otol Rhinol Laryngol Suppl"},{"key":"R23-20230812","doi-asserted-by":"crossref","first-page":"36S","DOI":"10.1097\/AUD.0b013e31829d5158","article-title":"Pediatric applications of wideband acoustic immittance measures.","volume":"34","author":"Hunter","year":"2013","journal-title":"Ear Hear"},{"issue":"2 Pt 1","key":"R24-20230812","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1177\/000348948609500208","article-title":"Stapedius reflex to electrical stimulation in a patient with a cochlear implant.","volume":"95","author":"Jerger","year":"1986","journal-title":"Ann Otol Rhinol Laryngol"},{"key":"R25-20230812","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1097\/00003446-198802000-00010","article-title":"Prediction of dynamic range from stapedius reflex in cochlear implant patients.","volume":"9","author":"Jerger","year":"1988","journal-title":"Ear Hear"},{"key":"R26-20230812","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1121\/1.390300","article-title":"Acoustical wave propagation in cylindrical ducts: Transmission line parameter approximations for isothermal and nonisothermal boundary conditions.","volume":"75","author":"Keefe","year":"1984","journal-title":"J Acoust Soc Am"},{"issue":"6 Pt 1","key":"R27-20230812","doi-asserted-by":"crossref","first-page":"3217","DOI":"10.1121\/1.1625931","article-title":"Energy transmittance predicts conductive hearing loss in older children and adults.","volume":"114","author":"Keefe","year":"2003","journal-title":"J Acoust Soc Am"},{"key":"R28-20230812","first-page":"70","article-title":"The use of ESRT in fitting children with cochlear implants.","volume":"5","author":"Kosaner","year":"2009","journal-title":"J Int Advan Otol"},{"key":"R29-20230812","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1159\/000095612","article-title":"Temporal bone results and hearing preservation with a new straight electrode.","volume":"11","author":"Lenarz","year":"2006","journal-title":"Audiol Neurootol"},{"issue":"6 Suppl","key":"R30-20230812","first-page":"S118","article-title":"Intraoperative electrical stimulation of the stapedius reflex in children.","volume":"18","author":"Lindstr\u00f6m","year":"1997","journal-title":"Am J Otol"},{"key":"R31-20230812","doi-asserted-by":"crossref","first-page":"3708","DOI":"10.1121\/1.3001712","article-title":"Wideband absorbance tympanometry using pressure sweeps: System development and results on adults with normal hearing.","volume":"124","author":"Liu","year":"2008","journal-title":"J Acoust Soc Am"},{"key":"R32-20230812","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1016\/0022-460X(78)90576-X","article-title":"Adaptation of the acoustic reflex to combinations of sustained steady-state and repeated pulse stimuli.","volume":"56","author":"Lutman","year":"1978","journal-title":"J Sound Vibration"},{"key":"R33-20230812","doi-asserted-by":"crossref","first-page":"1255","DOI":"10.1097\/MAO.0000000000001171","article-title":"Air-bone gaps contribute to functional hearing preservation in cochlear implantation.","volume":"37","author":"Mattingly","year":"2016","journal-title":"Otol Neurotol"},{"key":"R34-20230812","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1016\/j.heares.2017.11.006","article-title":"Sweep-tone evoked stimulus frequency otoacoustic emissions in humans: Development of a noise-rejection algorithm and normative features.","volume":"358","author":"Mishra","year":"2018","journal-title":"Hear Res"},{"key":"R35-20230812","doi-asserted-by":"crossref","first-page":"48S","DOI":"10.1097\/AUD.0b013e31829c964d","article-title":"Assessment of ear disorders using power reflectance.","volume":"34","author":"Nakajima","year":"2013","journal-title":"Ear Hear"},{"key":"R36-20230812","doi-asserted-by":"crossref","first-page":"e241","DOI":"10.1097\/AUD.0000000000000407","article-title":"The impact of a cochlear implant electrode array on the middle ear transfer function.","volume":"38","author":"Pazen","year":"2017","journal-title":"Ear Hear"},{"key":"R37-20230812","doi-asserted-by":"crossref","first-page":"639","DOI":"10.1097\/01.mao.0000178145.14010.25","article-title":"ECAP, ESR and subjective levels for two different nucleus 24 electrode arrays.","volume":"26","author":"Polak","year":"2005","journal-title":"Otol Neurotol"},{"key":"R38-20230812","doi-asserted-by":"crossref","first-page":"54S","DOI":"10.1097\/AUD.0b013e31829c9670","article-title":"Prediction of conductive hearing loss using wideband acoustic immittance.","volume":"34","author":"Prieve","year":"2013","journal-title":"Ear Hear"},{"key":"R39-20230812","doi-asserted-by":"crossref","first-page":"3873","DOI":"10.1121\/1.3654019","article-title":"Inverse solution of ear-canal area function from reflectance.","volume":"130","author":"Rasetshwane","year":"2011","journal-title":"J Acoust Soc Am"},{"key":"R41-20230812","doi-asserted-by":"crossref","first-page":"43S","DOI":"10.1097\/AUD.0b013e31829c70d9","article-title":"Acoustic reflex measurement.","volume":"34","author":"Schairer","year":"2013","journal-title":"Ear Hear"},{"key":"R42-20230812","doi-asserted-by":"crossref","first-page":"3882","DOI":"10.1121\/1.3655878","article-title":"Further assessment of forward pressure level for in situ calibration.","volume":"130","author":"Scheperle","year":"2011","journal-title":"J Acoust Soc Am"},{"key":"R43-20230812","doi-asserted-by":"crossref","first-page":"288","DOI":"10.1121\/1.2931953","article-title":"Influence of in situ, sound-level calibration on distortion-product otoacoustic emission variability.","volume":"124","author":"Scheperle","year":"2008","journal-title":"J Acoust Soc Am"},{"key":"R44-20230812","doi-asserted-by":"crossref","first-page":"27S","DOI":"10.1097\/AUD.0b013e31829d5328","article-title":"Wideband acoustic immittance normative data: Ethnicity, gender, aging, and instrumentation.","volume":"34","author":"Shahnaz","year":"2013","journal-title":"Ear Hear"},{"key":"R45-20230812","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1097\/00003446-199404000-00008","article-title":"The relationship between electrical acoustic reflex thresholds and behavioral comfort levels in children and adult cochlear implant patients.","volume":"15","author":"Spivak","year":"1994","journal-title":"Ear Hear"},{"key":"R46-20230812","doi-asserted-by":"crossref","first-page":"1225","DOI":"10.1288\/00005537-199410000-00007","article-title":"Programming the cochlear implant based on electrical acoustic reflex thresholds: Patient performance.","volume":"104","author":"Spivak","year":"1994","journal-title":"Laryngoscope"},{"key":"R47-20230812","doi-asserted-by":"crossref","first-page":"13","DOI":"10.3109\/00206090009073049","article-title":"Post-operative stapedius reflex tests with simultaneous loudness scaling in patients supplied with cochlear implants.","volume":"39","author":"Stephan","year":"2000","journal-title":"Audiology"},{"key":"R48-20230812","doi-asserted-by":"crossref","first-page":"501738","DOI":"10.1155\/2014\/501738","article-title":"Cochlear implant programming: A global survey on the state of the art.","volume":"2014","author":"Vaerenberg","year":"2014","journal-title":"ScientificWorldJournal"},{"key":"R49-20230812","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1179\/1754762810Y.0000000001","article-title":"Multicentre investigation on electrically evoked compound action potential and stapedius reflex: How do these objective measures relate to implant programming parameters?","volume":"13","author":"Van Den Abbeele","year":"2012","journal-title":"Cochlear Implants Int"},{"key":"R50-20230812","doi-asserted-by":"crossref","first-page":"1207","DOI":"10.1002\/lary.26840","article-title":"Effect of cochlear implantation on middle ear function: A three-month prospective study.","volume":"128","author":"Wasson","year":"2018","journal-title":"Laryngoscope"},{"key":"R51-20230812","doi-asserted-by":"crossref","first-page":"1605","DOI":"10.1121\/1.3075551","article-title":"An in situ calibration for hearing thresholds.","volume":"125","author":"Withnell","year":"2009","journal-title":"J Acoust Soc Am"},{"key":"R52-20230812","doi-asserted-by":"crossref","first-page":"70","DOI":"10.1179\/cim.2008.9.2.70","article-title":"Relationships among objective measures and speech perception in adult users of the HiResolution Bionic Ear.","volume":"9","author":"Wolfe","year":"2008","journal-title":"Cochlear Implants Int"},{"key":"R53-20230812","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1097\/AUD.0000000000000390","article-title":"Optimizations for the electrically-evoked stapedial reflex threshold measurement in cochlear implant recipients.","volume":"38","author":"Wolfe","year":"2017","journal-title":"Ear Hear"},{"key":"R54-20230812","doi-asserted-by":"crossref","first-page":"337","DOI":"10.3766\/jaaa.16176","article-title":"Measurement of the electrically evoked stapedial reflex response with wideband acoustic reflectance measurement.","volume":"29","author":"Wolfe","year":"2018","journal-title":"J Am Acad Audiol"}],"container-title":["Ear &amp; Hearing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/AUD.0000000000000810","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,12]],"date-time":"2023-08-12T08:06:17Z","timestamp":1691827577000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/AUD.0000000000000810"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,10,30]]},"references-count":53,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/aud.0000000000000810","relation":{},"ISSN":["0196-0202"],"issn-type":[{"value":"0196-0202","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,10,30]]}}}