{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T23:37:42Z","timestamp":1787009862756,"version":"build-2736575974"},"reference-count":59,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"abstract":"<jats:sec>\n                    <jats:title>Objectives:<\/jats:title>\n                    <jats:p>The primary objective of this study was to quantify local (within ear) and global (between ear) variation in the cochlear implant (CI) electrode-neuron interface (ENI) using the electrically evoked compound action potential (ECAP). We tested the hypothesis that, within an ear, ECAP measures can be used to identify channels with presumed good and poor ENIs, which may be influenced by a combination of spiral ganglion neuron (SGN) density, electrode position, and cochlear resistivity. We also hypothesized that ECAP responses would reflect age-related differences in the global quality of the ENI between younger and older listeners who theoretically differ in SGN density.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Design:<\/jats:title>\n                    <jats:p>Data were obtained from 18 implanted ears (13 individuals) with Advanced Bionics HiRes 90K devices. Six participants (8 ears) were adolescents or young adults (age range: 14\u201332 years), and 7 participants (10 ears) were older adults (age range: 54\u201388 years). In each ear, single-channel auditory detection thresholds were measured on channels 2 through 15 in response to a spatially focused electrode configuration (steered quadrupolar; focusing coefficient = 0.9). ECAP amplitudes, amplitude growth function (AGF) slopes, and thresholds were assessed on a subset of channels in each ear in response to three interphase gaps (0, 7, and 30 \u00b5s). ECAP peak amplitudes were assessed on all channels between 2 and 15. AGFs and ECAP thresholds were measured on the two nonadjacent channels with the lowest and highest focused behavioral thresholds in each ear. ECAP responses were compared across low- and high-threshold channels and between younger and older CI listeners.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>Channels that were estimated to interface poorly with the auditory nerve (i.e., high-focused-threshold channels) had steeper ECAP AGF slopes, smaller dynamic ranges, and higher ECAP thresholds than channels with low focused thresholds. Younger listeners had steeper ECAP AGF slopes and larger ECAP peak amplitudes than older listeners. Moreover, younger listeners showed greater interphase gap sensitivity for ECAP amplitude than older listeners.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>ECAP responses may be used to quantify both local (within ear) and global (between ear) variation in the quality of the ENI. Results of this study support future investigation into the use of ECAP responses in site-selection CI programming strategies. The present results also support a growing body of evidence suggesting that adolescents and young adults with CIs may have denser populations of functional SGNs relative to older adults. Potential differences in global SGN integrity between younger and older listeners warrant investigation of optimal CI programming interventions based on their divergent hearing histories.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/aud.0000000000000844","type":"journal-article","created":{"date-parts":[[2020,1,16]],"date-time":"2020-01-16T11:30:48Z","timestamp":1579174248000},"page":"961-973","source":"Crossref","is-referenced-by-count":31,"title":["Identifying Cochlear Implant Channels With Relatively Poor Electrode-Neuron Interfaces Using the Electrically Evoked Compound Action Potential"],"prefix":"10.1097","volume":"41","author":[{"given":"Kelly N.","family":"Jahn","sequence":"first","affiliation":[{"name":"Department of Otolaryngology \u2013 Head and Neck Surgery, Harvard Medical School, Boston, Massachusetts, USA"},{"name":"Eaton-Peabody Laboratories, Massachusetts Eye and Ear Infirmary, Boston, Massachusetts, USA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Julie G.","family":"Arenberg","sequence":"additional","affiliation":[{"name":"Department of Otolaryngology \u2013 Head and Neck Surgery, Harvard Medical School, Boston, Massachusetts, USA"},{"name":"Eaton-Peabody Laboratories, Massachusetts Eye and Ear Infirmary, Boston, Massachusetts, USA."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2020,7]]},"reference":[{"key":"R1-20230812","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1097\/00003446-199902000-00005","article-title":"Summary of results using the nucleus CI24M implant to record the electrically evoked compound action potential.","volume":"20","author":"Abbas","year":"1999","journal-title":"Ear Hear"},{"key":"R3-20230812","doi-asserted-by":"crossref","first-page":"1642","DOI":"10.1121\/1.2436712","article-title":"Threshold and channel interaction in cochlear implant users: Evaluation of the tripolar electrode configuration.","volume":"121","author":"Bierer","year":"2007","journal-title":"J Acoust Soc Am"},{"key":"R4-20230812","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1177\/1084713810375249","article-title":"Probing the electrode-neuron interface with focused cochlear implant stimulation.","volume":"14","author":"Bierer","year":"2010","journal-title":"Trends Amplif"},{"key":"R5-20230812","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1097\/AUD.0b013e3181c7daf4","article-title":"Identifying cochlear implant channels with poor electrode-neuron interface: Partial tripolar, single-channel thresholds and psychophysical tuning curves.","volume":"31","author":"Bierer","year":"2010","journal-title":"Ear Hear"},{"key":"R6-20230812","first-page":"1","article-title":"Reducing channel interaction through cochlear implant programming may improve speech perception: Current focusing and channel deactivation.","volume":"20","author":"Bierer","year":"2016","journal-title":"Trends Hear"},{"key":"R7-20230812","doi-asserted-by":"crossref","first-page":"641","DOI":"10.1097\/AUD.0000000000000058","article-title":"Comparisons between detection threshold and loudness perception for individual cochlear implant channels.","volume":"35","author":"Bierer","year":"2014","journal-title":"Ear Hear"},{"key":"R8-20230812","first-page":"1","article-title":"A fast method for measuring psychophysical thresholds across the cochlear implant array.","volume":"19","author":"Bierer","year":"2015a","journal-title":"Trends Hear"},{"key":"R9-20230812","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1007\/s10162-015-0507-y","article-title":"Comparison of signal and gap-detection thresholds for focused and broad cochlear implant electrode configurations.","volume":"16","author":"Bierer","year":"2015b","journal-title":"J Assoc Res Otolaryngol"},{"key":"R10-20230812","doi-asserted-by":"crossref","first-page":"436","DOI":"10.1097\/AUD.0b013e3181ff33ab","article-title":"Identifying cochlear implant channels with poor electrode-neuron interfaces: electrically evoked auditory brain stem responses measured with the partial tripolar configuration.","volume":"32","author":"Bierer","year":"2011","journal-title":"Ear Hear"},{"key":"R11-20230812","doi-asserted-by":"crossref","first-page":"5","DOI":"10.3766\/jaaa.21.1.2","article-title":"Effects of long-term use of a cochlear implant on the electrically evoked compound action potential.","volume":"21","author":"Brown","year":"2010","journal-title":"J Am Acad Audiol"},{"key":"R12-20230812","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1159\/000083366","article-title":"Normative findings of electrically evoked compound action potential measurements using the neural response telemetry of the Nucleus CI24M cochlear implant system.","volume":"10","author":"Cafarelli Dees","year":"2005","journal-title":"Audiol Neurootol"},{"key":"R13-20230812","doi-asserted-by":"crossref","first-page":"571","DOI":"10.1007\/s10162-018-0678-4","article-title":"Psychophysical tuning curves as a correlate of electrode position in cochlear implant listeners.","volume":"19","author":"DeVries","year":"2018","journal-title":"J Assoc Res Otolaryngol"},{"key":"R14-20230812","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1007\/s10162-016-0557-9","article-title":"Assessing the electrode-neuron interface with the electrically evoked compound action potential, electrode position, and behavioral thresholds.","volume":"17","author":"DeVries","year":"2016","journal-title":"J Assoc Res Otolaryngol"},{"key":"R15-20230812","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1007\/s10162-019-00716-4","article-title":"The estimated electrode-neuron interface in cochlear implant listeners is different for early-implanted children and late-implanted adults.","volume":"20","author":"DiNino","year":"2019","journal-title":"J Assoc Res Otolaryngol"},{"key":"R16-20230812","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1159\/000351302","article-title":"Using temporal modulation sensitivity to select stimulation sites for processor MAPs in cochlear implant listeners.","volume":"18","author":"Garadat","year":"2013","journal-title":"Audiol Neurootol"},{"issue":"Suppl 1","key":"R17-20230812","doi-asserted-by":"crossref","first-page":"S63","DOI":"10.1016\/j.anorl.2016.04.014","article-title":"Optimal electrode design: Straight versus perimodiolar.","volume":"133","author":"Gibson","year":"2016","journal-title":"Eur Ann Otorhinolaryngol Head Neck Dis"},{"key":"R18-20230812","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1016\/j.heares.2010.05.005","article-title":"Modeling the electrode-neuron interface of cochlear implants: Effects of neural survival, electrode placement, and the partial tripolar configuration.","volume":"268","author":"Goldwyn","year":"2010","journal-title":"Hear Res"},{"key":"R19-20230812","doi-asserted-by":"crossref","first-page":"908","DOI":"10.1097\/MAO.0b013e3181b236b0","article-title":"Evolution of cochlear implant arrays result in changes in behavioral and physiological responses in children.","volume":"30","author":"Gordin","year":"2009","journal-title":"Otol Neurotol"},{"key":"R20-20230812","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1016\/0378-5955(90)90188-U","article-title":"Estimation of surviving spiral ganglion cells in the deaf rat using the electrically evoked auditory brainstem response.","volume":"45","author":"Hall","year":"1990","journal-title":"Hear Res"},{"key":"R21-20230812","doi-asserted-by":"crossref","first-page":"238","DOI":"10.1097\/AUD.0000000000000467","article-title":"Responsiveness of the electrically stimulated cochlear nerve in children with cochlear nerve deficiency.","volume":"39","author":"He","year":"2018","journal-title":"Ear Hear"},{"key":"R22-20230812","doi-asserted-by":"crossref","first-page":"339","DOI":"10.3389\/fnins.2017.00339","article-title":"The electrically evoked compound action potential: From laboratory to clinic.","volume":"11","author":"He","year":"2017","journal-title":"Front Neurosci"},{"key":"R23-20230812","article-title":"The effect of interphase gap on neural response of the electrically stimulated cochlear nerve in children with cochlear nerve deficiency and children with normal-sized cochlear nerves.","author":"He","year":"2019","journal-title":"Ear Hear"},{"key":"R24-20230812","doi-asserted-by":"crossref","first-page":"471","DOI":"10.1097\/00003446-200112000-00004","article-title":"A longitudinal study of electrode impedance, the electrically evoked compound action potential, and behavioral measures in nucleus 24 cochlear implant users.","volume":"22","author":"Hughes","year":"2001","journal-title":"Ear Hear"},{"key":"R25-20230812","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1093\/biomet\/76.2.297","article-title":"Regression and time series model selection in small samples.","volume":"76","author":"Hurvich","year":"1989","journal-title":"Biometrika"},{"key":"R26-20230812","doi-asserted-by":"crossref","first-page":"415","DOI":"10.1007\/s10162-019-00718-2","article-title":"Evaluating psychophysical polarity sensitivity as an indirect estimate of neural status in cochlear implant listeners.","volume":"20","author":"Jahn","year":"2019a","journal-title":"J Assoc Res Otolaryngol"},{"key":"R27-20230812","first-page":"2331216519862987","article-title":"Polarity sensitivity in pediatric and adult cochlear implant listeners.","volume":"23","author":"Jahn","year":"2019b","journal-title":"Trends Hear"},{"key":"R28-20230812","doi-asserted-by":"crossref","first-page":"295","DOI":"10.1097\/AUD.0000000000000615","article-title":"Reducing simulated channel interaction reveals differences in phoneme identification between children and adults with normal hearing.","volume":"40","author":"Jahn","year":"2019","journal-title":"Ear Hear"},{"key":"R29-20230812","doi-asserted-by":"crossref","first-page":"1","DOI":"10.18637\/jss.v082.i13","article-title":"lmerTest Package: Tests in linear mixed effects models.","volume":"82","author":"Kuznetsova","year":"2017","journal-title":"J Statistical Softw"},{"key":"R30-20230812","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1016\/0378-5955(91)90120-X","article-title":"Chronic intracochlear electrical stimulation induces selective survival of spiral ganglion neurons in neonatally deafened cats.","volume":"54","author":"Leake","year":"1991","journal-title":"Hear Res"},{"key":"R31-20230812","doi-asserted-by":"crossref","first-page":"543","DOI":"10.1002\/(SICI)1096-9861(19991004)412:4<543::AID-CNE1>3.0.CO;2-3","article-title":"Chronic electrical stimulation by a cochlear implant promotes survival of spiral ganglion neurons after neonatal deafness.","volume":"412","author":"Leake","year":"1999","journal-title":"J Comp Neurol"},{"key":"R32-20230812","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1016\/0378-5955(92)90172-J","article-title":"Chronic intracochlear electrical stimulation in neonatally deafened cats: Effects of intensity and stimulating electrode location.","volume":"64","author":"Leake","year":"1992","journal-title":"Hear Res"},{"key":"R34-20230812","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1007\/s10162-013-0437-5","article-title":"Examining the electro-neural interface of cochlear implant users using psychophysics, CT scans, and speech understanding.","volume":"15","author":"Long","year":"2014","journal-title":"J Assoc Res Otolaryngol"},{"issue":"7 Pt 1","key":"R35-20230812","doi-asserted-by":"crossref","first-page":"836","DOI":"10.1288\/00005537-198707000-00012","article-title":"Increased spiral ganglion cell survival in electrically stimulated, deafened guinea pig cochleae.","volume":"97","author":"Lousteau","year":"1987","journal-title":"Laryngoscope"},{"key":"R36-20230812","doi-asserted-by":"crossref","first-page":"711","DOI":"10.1007\/s10162-011-0283-2","article-title":"Age-related primary cochlear neuronal degeneration in human temporal bones.","volume":"12","author":"Makary","year":"2011","journal-title":"J Assoc Res Otolaryngol"},{"key":"R37-20230812","doi-asserted-by":"crossref","first-page":"661","DOI":"10.1080\/00273171.2017.1344538","article-title":"Small sample methods for multilevel modeling: A colloquial elucidation of REML and the Kenward-Roger correction.","volume":"52","author":"McNeish","year":"2017","journal-title":"Multivariate Behav Res"},{"key":"R38-20230812","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1016\/0378-5955(94)90039-6","article-title":"The use of long-duration current pulses to assess nerve survival.","volume":"78","author":"Miller","year":"1994","journal-title":"Hear Res"},{"key":"R39-20230812","doi-asserted-by":"crossref","first-page":"222","DOI":"10.1159\/000377615","article-title":"Postimplantation changes of electrophysiological parameters in patients with cochlear implants.","volume":"20","author":"Molisz","year":"2015","journal-title":"Audiol Neurootol"},{"issue":"3 Pt 1","key":"R40-20230812","doi-asserted-by":"crossref","first-page":"220","DOI":"10.1016\/S0194-5998(97)70178-5","article-title":"Patterns of neural degeneration in the human cochlea and auditory nerve: Implications for cochlear implantation.","volume":"117","author":"Nadol","year":"1997","journal-title":"Otolaryngol Head Neck Surg"},{"key":"R41-20230812","doi-asserted-by":"crossref","first-page":"411","DOI":"10.1177\/000348948909800602","article-title":"Survival of spiral ganglion cells in profound sensorineural hearing loss: Implications for cochlear implantation.","volume":"98","author":"Nadol","year":"1989","journal-title":"Ann Otol Rhinol Laryngol"},{"key":"R42-20230812","doi-asserted-by":"crossref","first-page":"400","DOI":"10.1159\/000365273","article-title":"Clinical evaluation of an image-guided cochlear implant programming strategy.","volume":"19","author":"Noble","year":"2014","journal-title":"Audiol Neurootol"},{"key":"R43-20230812","doi-asserted-by":"crossref","first-page":"e63","DOI":"10.1097\/MAO.0000000000000909","article-title":"Initial results with image-guided cochlear implant programming in children.","volume":"37","author":"Noble","year":"2016","journal-title":"Otol Neurotol"},{"key":"R44-20230812","doi-asserted-by":"crossref","first-page":"820","DOI":"10.1109\/TNSRE.2013.2253333","article-title":"Image-guidance enables new methods for customizing cochlear implant stimulation strategies.","volume":"21","author":"Noble","year":"2013","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"issue":"8 Pt 1","key":"R45-20230812","doi-asserted-by":"crossref","first-page":"1231","DOI":"10.1288\/00005537-197808000-00004","article-title":"Ganglion cell populations in normal and pathological human cochleae. Implications for cochlear implantation.","volume":"88","author":"Otte","year":"1978","journal-title":"Laryngoscope"},{"key":"R46-20230812","first-page":"42","article-title":"Cochlea size variability and implications in clinical practice.","volume":"34","author":"Pelliccia","year":"2014","journal-title":"Acta Otorhinolaryngol Ital"},{"key":"R47-20230812","doi-asserted-by":"crossref","first-page":"731","DOI":"10.1007\/s10162-017-0633-9","article-title":"Neurotrophin gene therapy in deafened ears with cochlear implants: Long-term effects on nerve survival and functional measures.","volume":"18","author":"Pfingst","year":"2017","journal-title":"J Assoc Res Otolaryngol"},{"issue":"Pt A","key":"R48-20230812","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1016\/j.heares.2015.07.010","article-title":"Insertion trauma and recovery of function after cochlear implantation: Evidence from objective functional measures.","volume":"330","author":"Pfingst","year":"2015","journal-title":"Hear Res"},{"key":"R49-20230812","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1159\/000081283","article-title":"Across-site threshold variation in cochlear implants: Relation to speech recognition.","volume":"9","author":"Pfingst","year":"2004","journal-title":"Audiol Neurootol"},{"key":"R50-20230812","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1016\/j.heares.2006.03.006","article-title":"Effect of interphase gap and pulse duration on electrically evoked potentials is correlated with auditory nerve survival.","volume":"215","author":"Prado-Guitierrez","year":"2006","journal-title":"Hear Res"},{"key":"R52-20230812","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1007\/s10162-013-0440-x","article-title":"Auditory-nerve responses to varied inter-phase gap and phase duration of the electric pulse stimulus as predictors for neuronal degeneration.","volume":"15","author":"Ramekers","year":"2014","journal-title":"J Assoc Res Otolaryngol"},{"key":"R54-20230812","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1016\/j.heares.2016.08.002","article-title":"Across-site patterns of electrically evoked compound action potential amplitude-growth functions in multichannel cochlear implant recipients and the effects of the interphase gap.","volume":"341","author":"Schvartz-Leyzac","year":"2016","journal-title":"Hear Res"},{"key":"R55-20230812","doi-asserted-by":"crossref","first-page":"344","DOI":"10.1097\/AUD.0000000000000490","article-title":"Assessing the relationship between the electrically evoked compound action potential and speech recognition abilities in bilateral cochlear implant recipients.","volume":"39","author":"Schvartz-Leyzac","year":"2018","journal-title":"Ear Hear"},{"key":"R56-20230812","doi-asserted-by":"crossref","first-page":"408","DOI":"10.1080\/14992020500060800","article-title":"Development of a fast method for determining psychophysical tuning curves.","volume":"44","author":"Sek","year":"2005","journal-title":"Int J Audiol"},{"key":"R57-20230812","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1016\/S0378-5955(97)00046-4","article-title":"Electrical stimulation of the auditory nerve. I. Correlation of physiological responses with cochlear status.","volume":"108","author":"Shepherd","year":"1997","journal-title":"Hear Res"},{"key":"R58-20230812","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1016\/0378-5955(93)90265-3","article-title":"Electrical stimulation of the auditory nerve: The effect of electrode position on neural excitation.","volume":"66","author":"Shepherd","year":"1993","journal-title":"Hear Res"},{"issue":"1 Pt 1","key":"R59-20230812","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1177\/000348948309200105","article-title":"Estimating eighth nerve survival by electrical stimulation.","volume":"92","author":"Smith","year":"1983","journal-title":"Ann Otol Rhinol Laryngol"},{"key":"R60-20230812","doi-asserted-by":"crossref","first-page":"501738","DOI":"10.1155\/2014\/501738","article-title":"Cochlear implant programming: A global survey on the state of the art.","volume":"2014","author":"Vaerenberg","year":"2014","journal-title":"ScientificWorldJournal"},{"key":"R61-20230812","doi-asserted-by":"crossref","first-page":"1527","DOI":"10.1007\/s00405-009-0939-2","article-title":"Imaging of electrode position in relation to electrode functioning after cochlear implantation.","volume":"266","author":"van Wermeskerken","year":"2009","journal-title":"Eur Arch Otorhinolaryngol"},{"key":"R62-20230812","doi-asserted-by":"crossref","first-page":"EL243","DOI":"10.1121\/1.4977235","article-title":"Deactivating stimulation sites based on low-rate thresholds improves spectral ripple and speech reception thresholds in cochlear implant users.","volume":"141","author":"Zhou","year":"2017","journal-title":"J Acoust Soc Am"},{"key":"R63-20230812","article-title":"Electrophysiological estimates of the electrode-neuron interface differ between younger and older listeners with cochlear implants.","author":"Jahn","journal-title":"Ear Hear"}],"container-title":["Ear &amp; Hearing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/AUD.0000000000000844","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,7,30]],"date-time":"2024-07-30T02:20:11Z","timestamp":1722306011000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/AUD.0000000000000844"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,1,14]]},"references-count":59,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/aud.0000000000000844","relation":{},"ISSN":["0196-0202"],"issn-type":[{"value":"0196-0202","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,1,14]]}}}