{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,12]],"date-time":"2026-05-12T10:20:12Z","timestamp":1778581212260,"version":"3.51.4"},"reference-count":77,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n            <jats:title>Objectives:<\/jats:title>\n            <jats:p>This study aimed to investigate effects of aging and duration of deafness on sensitivity of the auditory nerve (AN) to amplitude modulation (AM) cues delivered using trains of biphasic pulses in adult cochlear implant (CI) users.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Design:<\/jats:title>\n            <jats:p>There were 21 postlingually deaf adult CI users who participated in this study. All study participants used a Cochlear Nucleus device with a full electrode array insertion in the test ear. The stimulus was a 200-ms pulse train with a pulse rate of 2000 pulses per second. This carrier pulse train was sinusodially AM at four modulation rates (20, 40, 100, 200 Hz). The peak amplitude of the modulated pulse train was the maximum comfortable level (i.e., C level) measured for the carrier pulse train. The electrically evoked compound action potential (eCAP) to each of the 20 pulses selected over the last two AM cycles were measured. In addition, eCAPs to single pulses were measured with the probe levels corresponding to the levels of 20 selected pulses from each AM pulse train. There were seven electrodes across the array evaluated in 16 subjects (i.e., electrodes 3 or 4, 6, 9, 12, 15, 18, and 21). For the remaining five subjects, 4 to 5 electrodes were tested due to impedance issues or time constraints. The modulated response amplitude ratio (MRAR) was calculated as the ratio of the difference in the maximum and the minimum eCAP amplitude measured for the AM pulse train to that measured for the single pulse, and served as the dependent variable. Age at time of testing and duration of deafness measured\/defined using three criteria served as the independent variables. Linear Mixed Models were used to assess the effects of age at testing and duration of deafness on the MRAR.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Age at testing had a strong, negative effect on the MRAR. For each subject, the duration of deafness varied substantially depending on how it was defined\/measured, which demonstrates the difficulty of accurately measuring the duration of deafness in adult CI users. There was no clear or reliable trend showing a relationship between the MRAR measured at any AM rate and duration of deafness defined by any criteria. After controlling for the effect of age at testing, MRARs measured at 200 Hz and basal electrode locations (i.e., electrodes 3 and 6) were larger than those measured at any other AM rate and apical electrode locations (i.e., electrodes 18 and 21)<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>The AN sensitivity to AM cues implemented in the pulse-train stimulation significantly declines with advanced age. Accurately measuring duration of deafness in adult CI users is challenging, which, at least partially, might have accounted for the inconclusive findings in the relationship between the duration of deafness and the AN sensitivity to AM cues in this study.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/aud.0000000000001035","type":"journal-article","created":{"date-parts":[[2021,4,2]],"date-time":"2021-04-02T09:15:01Z","timestamp":1617354901000},"page":"1358-1372","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":11,"title":["The Sensitivity of the Electrically Stimulated Auditory Nerve to Amplitude Modulation Cues Declines With Advanced Age"],"prefix":"10.1097","volume":"42","author":[{"given":"William J.","family":"Riggs","sequence":"first","affiliation":[{"name":"Department of Otolaryngology-Head and Neck Surgery, The Ohio State University, Columbus, Ohio, USA"},{"name":"Department of Audiology, Nationwide Children\u2019s Hospital, Columbus, Ohio, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chloe","family":"Vaughan","sequence":"additional","affiliation":[{"name":"Department of Otolaryngology-Head and Neck Surgery, The Ohio State University, Columbus, Ohio, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jeffrey","family":"Skidmore","sequence":"additional","affiliation":[{"name":"Department of Otolaryngology-Head and Neck Surgery, The Ohio State University, Columbus, Ohio, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sara","family":"Conroy","sequence":"additional","affiliation":[{"name":"Center for Biostatistics, Department of Bioinformatics, The Ohio State University, Columbus, Ohio, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Angela","family":"Pellittieri","sequence":"additional","affiliation":[{"name":"Head and Neck Institute, The Cleveland Clinic, Cleveland, Ohio, USA."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Brittney L.","family":"Carter","sequence":"additional","affiliation":[{"name":"Department of Otolaryngology-Head and Neck Surgery, The Ohio State University, Columbus, Ohio, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Curtis J.","family":"Stegman","sequence":"additional","affiliation":[{"name":"Department of Otolaryngology-Head and Neck Surgery, The Ohio State University, Columbus, Ohio, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shuman","family":"He","sequence":"additional","affiliation":[{"name":"Department of Otolaryngology-Head and Neck Surgery, The Ohio State University, Columbus, Ohio, USA"},{"name":"Department of Audiology, Nationwide Children\u2019s Hospital, Columbus, Ohio, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2021,9]]},"reference":[{"key":"R2-20250526","doi-asserted-by":"crossref","first-page":"202","DOI":"10.1016\/j.jneumeth.2011.12.005","article-title":"Application of triphasic pulses with adjustable phase amplitude ratio (PAR) for cochlear ECAP recording: I. Amplitude growth functions.","volume":"205","author":"Bahmer","year":"2012","journal-title":"J Neurosci Methods"},{"key":"R3-20250526","doi-asserted-by":"crossref","first-page":"1238","DOI":"10.1097\/MAO.0000000000001162","article-title":"Cochlear implants in adults: Effects of age and duration of deafness on speech recognition.","volume":"37","author":"Beyea","year":"2016","journal-title":"Otol Neurotol"},{"key":"R4-20250526","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1159\/000259212","article-title":"Factors affecting auditory performance of postlinguistically deaf adults using cochlear implants.","volume":"1","author":"Blamey","year":"1996","journal-title":"Audiol Neurootol"},{"key":"R5-20250526","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1186\/1475-925X-8-40","article-title":"Site of cochlear stimulation and its effect on electrically evoked compound action potentials using the MED-EL standard electrode array.","volume":"8","author":"Brill","year":"2009","journal-title":"Biomed Eng Online"},{"key":"R6-20250526","doi-asserted-by":"crossref","first-page":"1385","DOI":"10.1121\/1.399716","article-title":"Electrically evoked whole-nerve action potentials: Data from human cochlear implant users.","volume":"88","author":"Brown","year":"1990","journal-title":"J Acoust Soc Am"},{"key":"R7-20250526","doi-asserted-by":"crossref","first-page":"446","DOI":"10.1111\/j.1532-5415.2010.03310.x","article-title":"The effects of cochlear implantation on speech perception in older adults.","volume":"59","author":"Budenz","year":"2011","journal-title":"J Am Geriatr Soc"},{"key":"R8-20250526","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1016\/S0378-5955(00)00109-X","article-title":"Evaluation of a model of the cochlear neural membrane. I. Physiological measurement of membrane characteristics in response to intrameatal electrical stimulation.","volume":"146","author":"Cartee","year":"2000","journal-title":"Hear Res"},{"key":"R9-20250526","doi-asserted-by":"crossref","first-page":"298","DOI":"10.1097\/00129492-200405000-00017","article-title":"Cochlear implant outcomes in the elderly.","volume":"25","author":"Chatelin","year":"2004","journal-title":"Otol Neurotol"},{"key":"R10-20250526","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1016\/j.heares.2007.11.004","article-title":"Processing F0 with cochlear implants: modulation frequency discrimination and speech intonation recognition.","volume":"235","author":"Chatterjee","year":"2008","journal-title":"Hear Res"},{"key":"R11-20250526","doi-asserted-by":"crossref","first-page":"850","DOI":"10.1097\/AUD.0b013e318157671f","article-title":"Adaptation of the electrically evoked compound action potential (ECAP) recorded from nucleus CI24 cochlear implant users.","volume":"28","author":"Clay","year":"2007","journal-title":"Ear Hear"},{"key":"R12-20250526","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1097\/AUD.0000000000000162","article-title":"Amplitude modulation detection and speech recognition in late-implanted prelingually and postlingually deafened cochlear implant users.","volume":"36","author":"De Ruiter","year":"2015","journal-title":"Ear Hear"},{"key":"R13-20250526","doi-asserted-by":"crossref","first-page":"843","DOI":"10.1121\/1.384824","article-title":"Representation of speech-like sounds in the discharge patterns of auditory-nerve fibers.","volume":"68","author":"Delgutte","year":"1980","journal-title":"J Acoust Soc Am"},{"key":"R14-20250526","doi-asserted-by":"crossref","first-page":"897","DOI":"10.1121\/1.390599","article-title":"Speech coding in the auditory nerve: IV. Sounds with consonant-like dynamic characteristics.","volume":"75","author":"Delgutte","year":"1984","journal-title":"J Acoust Soc Am"},{"key":"R15-20250526","doi-asserted-by":"crossref","first-page":"279","DOI":"10.1001\/jamaoto.2013.1814","article-title":"Long-term speech perception in elderly cochlear implant users.","volume":"139","author":"Dillon","year":"2013","journal-title":"JAMA Otolaryngol Head Neck Surg"},{"key":"R16-20250526","doi-asserted-by":"crossref","first-page":"991","DOI":"10.1121\/1.2214463","article-title":"Effects of age and sequence presentation rate on temporal order recognition.","volume":"120","author":"Fitzgibbons","year":"2006","journal-title":"J Acoust Soc Am"},{"key":"R18-20250526","doi-asserted-by":"crossref","first-page":"432","DOI":"10.1001\/archoto.2010.57","article-title":"Case-control analysis of cochlear implant performance in elderly patients.","volume":"136","author":"Friedland","year":"2010","journal-title":"Arch Otolaryngol Head Neck Surg"},{"key":"R19-20250526","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1097\/00003446-200206000-00003","article-title":"Initial evaluation of the Clarion CII cochlear implant: Speech perception and neural response imaging.","volume":"23","author":"Frijns","year":"2002","journal-title":"Ear Hear"},{"key":"R20-20250526","doi-asserted-by":"crossref","first-page":"1635","DOI":"10.1097\/00001756-200209160-00013","article-title":"Temporal processing and speech recognition in cochlear implant users.","volume":"13","author":"Fu","year":"2002","journal-title":"Neuroreport"},{"key":"R21-20250526","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1159\/000351302","article-title":"Using temporal modulation sensitivity to select stimulation sites for processor MAPs in cochlear implant listeners.","volume":"18","author":"Garadat","year":"2013","journal-title":"Audiol Neurootol"},{"key":"R22-20250526","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1179\/cim.2007.8.1.1","article-title":"Predictors of audiological outcome following cochlear implantation in adults.","volume":"8","author":"Green","year":"2007","journal-title":"Cochlear Implants Int"},{"key":"R23-20250526","doi-asserted-by":"crossref","first-page":"2305","DOI":"10.1121\/1.2172169","article-title":"Temporal processing deficits in the pre-senescent auditory system.","volume":"119","author":"Grose","year":"2006","journal-title":"J Acoust Soc Am"},{"key":"R24-20250526","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1080\/00016489.1990.12088419","article-title":"Impulse patterns of auditory nerve fibres to extra- and intracochlear electrical stimulation.","volume":"469","author":"Hartmann","year":"1990","journal-title":"Acta Otolaryngol Suppl"},{"key":"R25-20250526","doi-asserted-by":"crossref","first-page":"397","DOI":"10.1097\/AUD.0000000000000254","article-title":"Temporal response properties of the auditory nerve in implanted children with auditory neuropathy spectrum disorder and implanted children with sensorineural hearing loss.","volume":"37","author":"He","year":"2016","journal-title":"Ear Hear"},{"key":"R26-20250526","doi-asserted-by":"crossref","first-page":"238","DOI":"10.1097\/AUD.0000000000000467","article-title":"Responsiveness of the electrically stimulated cochlear nerve in children with cochlear nerve deficiency.","volume":"39","author":"He","year":"2018","journal-title":"Ear Hear"},{"key":"R27-20250526","doi-asserted-by":"crossref","first-page":"918","DOI":"10.1097\/AUD.0000000000000815","article-title":"The effect of interphase gap on neural response of the electrically stimulated cochlear nerve in children with cochlear nerve deficiency and children with normal-sized cochlear nerves.","volume":"41","author":"He","year":"2019","journal-title":"Ear Hear"},{"key":"R28-20250526","doi-asserted-by":"crossref","first-page":"339","DOI":"10.3389\/fnins.2017.00339","article-title":"The electrically evoked compound action potential: from laboratory to clinic.","volume":"11","author":"He","year":"2017","journal-title":"Front Neurosci"},{"key":"R29-20250526","doi-asserted-by":"crossref","first-page":"343","DOI":"10.1523\/JNEUROSCI.2784-18.2019","article-title":"Temporal coding of single auditory nerve fibers is not degraded in aging gerbils.","volume":"40","author":"Heeringa","year":"2020","journal-title":"J Neurosci"},{"key":"R30-20250526","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1016\/0378-5955(90)90042-N","article-title":"Compound action potential input\/output functions in young and quiet-aged gerbils.","volume":"50","author":"Hellstrom","year":"1990","journal-title":"Hear Res"},{"key":"R31-20250526","doi-asserted-by":"crossref","first-page":"342","DOI":"10.1097\/AUD.0b013e3182741aa7","article-title":"Factors affecting open-set word recognition in adults with cochlear implants.","volume":"34","author":"Holden","year":"2013","journal-title":"Ear Hear"},{"key":"R32-20250526","doi-asserted-by":"crossref","first-page":"1662","DOI":"10.1097\/MAO.0000000000001241","article-title":"Factors affecting outcomes in cochlear implant recipients implanted with a perimodiolar electrode array located in scala tympani.","volume":"37","author":"Holden","year":"2016","journal-title":"Otol Neurotol"},{"key":"R33-20250526","doi-asserted-by":"crossref","first-page":"641","DOI":"10.1007\/s10162-010-0225-4","article-title":"Changes in auditory nerve responses across the duration of sinusoidally amplitude-modulated electric pulse-train stimuli.","volume":"11","author":"Hu","year":"2010","journal-title":"J Assoc Res Otolaryngol"},{"key":"R34-20250526","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1016\/j.heares.2012.01.010","article-title":"Temporal response properties of the auditory nerve: Data from human cochlear-implant recipients.","volume":"285","author":"Hughes","year":"2012","journal-title":"Hear Res"},{"key":"R35-20250526","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1016\/j.heares.2017.12.015","article-title":"What can stimulus polarity and interphase gap tell us about auditory nerve function in cochlear-implant recipients?","volume":"359","author":"Hughes","year":"2018","journal-title":"Hear Res"},{"key":"R36-20250526","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1177\/00034894870960S111","article-title":"Responses of cat auditory-nerve fibers to biphasic electrical-current pulses.","volume":"96","author":"Javel","year":"1987","journal-title":"Ann of Otol Rhinol Laryngol"},{"key":"R37-20250526","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1016\/j.heares.2008.10.007","article-title":"Effects of temporal properties on compound action potentials in response to amplitude-modulated electric pulse trains in guinea pigs.","volume":"247","author":"Jeng","year":"2009","journal-title":"Hear Res"},{"key":"R38-20250526","doi-asserted-by":"crossref","first-page":"1041","DOI":"10.1097\/MAO.0b013e3181ec1d92","article-title":"The relationship between electrically evoked compound action potential and speech perception: A study in cochlear implant users with short electrode array.","volume":"31","author":"Kim","year":"2010","journal-title":"Otol Neurotol"},{"key":"R39-20250526","doi-asserted-by":"crossref","first-page":"531","DOI":"10.1152\/jn.00794.2009","article-title":"Auditory temporal acuity probed with cochlear implant stimulation and cortical recording.","volume":"103","author":"Kirby","year":"2010","journal-title":"J Neurophysiol"},{"key":"R40-20250526","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1007\/s10162-011-0293-0","article-title":"Unanesthetized auditory cortex exhibits multiple codes for gaps in cochlear implant pulse trains.","volume":"13","author":"Kirby","year":"2012","journal-title":"J Assoc Res Otolaryngol"},{"key":"R41-20250526","doi-asserted-by":"crossref","first-page":"18","DOI":"10.3766\/jaaa.23.1.3","article-title":"Age-related changes in the auditory brainstem response.","volume":"23","author":"Konrad-Martin","year":"2012","journal-title":"J Am Acad Audiol"},{"key":"R42-20250526","doi-asserted-by":"crossref","first-page":"3317","DOI":"10.1007\/s00405-019-05644-w","article-title":"The impact of etiology and duration of deafness on speech perception outcomes in SSD patients.","volume":"276","author":"Kurz","year":"2019","journal-title":"Eur Arch Otorhinolaryngol"},{"key":"R43-20250526","doi-asserted-by":"crossref","first-page":"e311","DOI":"10.1097\/MAO.0000000000002122","article-title":"Temporal modulation detection in children and adults with cochlear implants: Initial results.","volume":"40","author":"Landsberger","year":"2019","journal-title":"Otol Neurotol"},{"key":"R44-20250526","doi-asserted-by":"crossref","first-page":"1361","DOI":"10.1002\/lary.23232","article-title":"Cochlear implant performance in geriatric patients.","volume":"122","author":"Lenarz","year":"2012","journal-title":"Laryngoscope"},{"key":"R45-20250526","doi-asserted-by":"crossref","first-page":"1049","DOI":"10.1001\/archotol.131.12.1049","article-title":"Predictive models for cochlear implantation in elderly candidates.","volume":"131","author":"Leung","year":"2005","journal-title":"Arch Otolaryngol Head Neck Surg"},{"key":"R46-20250526","doi-asserted-by":"crossref","first-page":"605","DOI":"10.1007\/s10162-011-0277-0","article-title":"Primary neural degeneration in the Guinea pig cochlea after reversible noise-induced threshold shift.","volume":"12","author":"Lin","year":"2011","journal-title":"J Assoc Res Otolaryngol"},{"key":"R47-20250526","doi-asserted-by":"crossref","first-page":"368","DOI":"10.1121\/1.1375140","article-title":"Auditory nerve fiber responses to electric stimulation: Modulated and unmodulated pulse trains.","volume":"110","author":"Litvak","year":"2001","journal-title":"J Acoust Soc Am"},{"key":"R48-20250526","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1007\/s10162-013-0437-5","article-title":"Examining the electro-neural interface of cochlear implant users using psychophysics, CT scans, and speech understanding.","volume":"15","author":"Long","year":"2014","journal-title":"J Assoc Res Otolaryngol"},{"key":"R49-20250526","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1007\/s10162-008-0112-4","article-title":"Higher sensitivity of human auditory nerve fibers to positive electrical currents.","volume":"9","author":"Macherey","year":"2008","journal-title":"J Assoc Res Otolaryngol"},{"key":"R50-20250526","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1016\/S0378-5955(00)00172-6","article-title":"The neuronal response to electrical constant-amplitude pulse train stimulation: Evoked compound action potential recordings.","volume":"149","author":"Matsuoka","year":"2000","journal-title":"Hear Res"},{"key":"R51-20250526","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1016\/S0378-5955(97)00099-3","article-title":"Age-related decline of auditory function in the chinchilla (Chinchilla laniger).","volume":"111","author":"McFadden","year":"1997","journal-title":"Hear Res"},{"key":"R52-20250526","doi-asserted-by":"crossref","first-page":"e248","DOI":"10.1097\/MAO.0000000000001257","article-title":"Cochlear implantation in postlingual adult patients with long-term auditory deprivation.","volume":"38","author":"Medina","year":"2017","journal-title":"Otol Neurotol"},{"key":"R53-20250526","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1016\/S0378-5955(98)00046-X","article-title":"Electrically evoked compound action potentials of guinea pig and cat: Responses to monopolar, monophasic stimulation.","volume":"119","author":"Miller","year":"1998","journal-title":"Hear Res"},{"key":"R54-20250526","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1016\/S0300-2977(00)00082-6","article-title":"Auditory nerve responses to monophasic and biphasic electric stimuli.","volume":"151","author":"Miller","year":"2001","journal-title":"Hear Res"},{"key":"R55-20250526","doi-asserted-by":"crossref","first-page":"173","DOI":"10.3109\/00016489.2013.850175","article-title":"Is there a deafness duration limit for cochlear implants in post-lingual deaf adults?","volume":"134","author":"Moon","year":"2014","journal-title":"Acta Otolaryngol"},{"key":"R56-20250526","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1177\/1084713806296386","article-title":"The development of the Nucleus Freedom Cochlear implant system.","volume":"10","author":"Patrick","year":"2006","journal-title":"Trends Amplif"},{"key":"R57-20250526","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1016\/j.heares.2014.09.009","article-title":"Importance of cochlear health for implant function.","volume":"322","author":"Pfingst","year":"2015","journal-title":"Hear Res"},{"key":"R58-20250526","doi-asserted-by":"crossref","first-page":"104","DOI":"10.1016\/S0378-5955(03)00309-5","article-title":"Further prospective findings with compound action potentials from Nucleus 24 cochlear implants.","volume":"188","author":"Polak","year":"2004","journal-title":"Hear Res"},{"key":"R59-20250526","doi-asserted-by":"crossref","first-page":"1952","DOI":"10.1002\/lary.23676","article-title":"Differential cochlear implant outcomes in older adults.","volume":"123","author":"Roberts","year":"2013","journal-title":"Laryngoscope"},{"key":"R60-20250526","first-page":"367","article-title":"Temporal information in speech - acoustic, auditory and linguistic aspects.","volume":"336","author":"Rosen","year":"1992","journal-title":"Philos Trans Royal Soc London Series B-Biol Sci"},{"key":"R61-20250526","first-page":"445","article-title":"Residual speech recognition and cochlear implant performance: Effects of implantation criteria.","volume":"20","author":"Rubinstein","year":"1999","journal-title":"Am J Otol"},{"key":"R62-20250526","doi-asserted-by":"crossref","first-page":"13686","DOI":"10.1523\/JNEUROSCI.1783-13.2013","article-title":"Age-related cochlear synaptopathy: An early-onset contributor to auditory functional decline.","volume":"33","author":"Sergeyenko","year":"2013","journal-title":"J Neurosci"},{"key":"R63-20250526","doi-asserted-by":"crossref","first-page":"2156","DOI":"10.1121\/1.403807","article-title":"Temporal modulation transfer functions in patients with cochlear implants.","volume":"91","author":"Shannon","year":"1992","journal-title":"J Acoust Soc Am"},{"key":"R64-20250526","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1126\/science.270.5234.303","article-title":"Speech recognition with primarily temporal cues.","volume":"270","author":"Shannon","year":"1995","journal-title":"Science"},{"key":"R65-20250526","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1016\/S0378-5955(97)00046-4","article-title":"Electrical stimulation of the auditory nerve. I. Correlation of physiological responses with cochlear status.","volume":"108","author":"Shepherd","year":"1997","journal-title":"Hear Res"},{"key":"R66-20250526","doi-asserted-by":"crossref","first-page":"3131","DOI":"10.1111\/j.1460-9568.2004.03809.x","article-title":"Long-term sensorineural hearing loss induces functional changes in the rat auditory nerve.","volume":"20","author":"Shepherd","year":"2004","journal-title":"Eur J Neurosci"},{"key":"R67-20250526","doi-asserted-by":"crossref","first-page":"510","DOI":"10.1111\/j.1460-9568.2007.05678.x","article-title":"Deafness alters auditory nerve fibre responses to cochlear implant stimulation.","volume":"26","author":"Sly","year":"2007","journal-title":"Eur J Neurosci"},{"key":"R68-20250526","doi-asserted-by":"crossref","first-page":"1615","DOI":"10.1121\/1.428446","article-title":"Relationships among age-related differences in gap detection and word recognition.","volume":"107","author":"Snell","year":"2000","journal-title":"J Acoust Soc Am"},{"key":"R69-20250526","doi-asserted-by":"crossref","first-page":"1636","DOI":"10.1097\/MAO.0b013e31829e83c9","article-title":"Stability of audiometric measures and challenges in long-term management of the elderly cochlear implant patient.","volume":"34","author":"Spitzer","year":"2013","journal-title":"Otol Neurotol"},{"key":"R70-20250526","doi-asserted-by":"crossref","first-page":"e268","DOI":"10.1097\/AUD.0000000000000417","article-title":"Relationship between peripheral and psychophysical measures of amplitude modulation detection in cochlear implant users.","volume":"38","author":"Tejani","year":"2017","journal-title":"Ear Hear"},{"key":"R71-20250526","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1007\/s10162-013-0377-0","article-title":"The polarity sensitivity of the electrically stimulated human auditory nerve measured at the level of the brainstem.","volume":"14","author":"Undurraga","year":"2013","journal-title":"J Assoc Res Otolaryngol"},{"key":"R72-20250526","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1016\/0378-5955(84)90052-2","article-title":"Physiological properties of the electrically stimulated auditory nerve. II. Single fiber recordings.","volume":"14","author":"van den Honert","year":"1984","journal-title":"Hear Res"},{"key":"R73-20250526","doi-asserted-by":"crossref","first-page":"188","DOI":"10.1097\/00129492-200503000-00010","article-title":"Quality-of-life benefit from cochlear implantation in the elderly.","volume":"26","author":"Vermeire","year":"2005","journal-title":"Otol Neurotol"},{"key":"R74-20250526","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1016\/j.heares.2015.04.014","article-title":"Cochlear neuropathy in human presbycusis: Confocal analysis of hidden hearing loss in post-mortem tissue.","volume":"327","author":"Viana","year":"2015","journal-title":"Hear Res"},{"key":"R75-20250526","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1038\/352236a0","article-title":"Better speech recognition with cochlear implants.","volume":"352","author":"Wilson","year":"1991","journal-title":"Nature"},{"issue":"6 Suppl","key":"R76-20250526","first-page":"S30","article-title":"Temporal representations with cochlear implants.","volume":"18","author":"Wilson","year":"1997","journal-title":"Am J Otol"},{"key":"R77-20250526","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1016\/j.neuroscience.2018.07.053","article-title":"Primary neural degeneration in the human cochlea: Evidence for hidden hearing loss in the aging ear.","volume":"407","author":"Wu","year":"2019","journal-title":"Neuroscience"},{"key":"R78-20250526","doi-asserted-by":"crossref","first-page":"2331216519886688","DOI":"10.1177\/2331216519886688","article-title":"Age-related temporal processing deficits in word segments in adult cochlear-implant users.","volume":"23","author":"Xie","year":"2019","journal-title":"Trends Hear"},{"key":"R79-20250526","doi-asserted-by":"crossref","first-page":"192","DOI":"10.1016\/0378-5955(95)00165-1","article-title":"Patterns of degeneration in the human cochlear nerve.","volume":"90","author":"Zimmermann","year":"1995","journal-title":"Hear Res"}],"container-title":["Ear &amp; Hearing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/AUD.0000000000001035","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,26]],"date-time":"2025-05-26T21:13:11Z","timestamp":1748293991000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/AUD.0000000000001035"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,4,1]]},"references-count":77,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.1097\/aud.0000000000001035","relation":{},"ISSN":["1538-4667"],"issn-type":[{"value":"1538-4667","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,4,1]]}}}