{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,6]],"date-time":"2026-11-06T11:04:22Z","timestamp":1793963062466,"version":"4.8.0"},"reference-count":31,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,5]]},"abstract":"<jats:sec>\n                    <jats:title>Objectives:<\/jats:title>\n                    <jats:p>This study was a continuation of work on an explore-and-select approach to the self-adjustment of amplification. Goals were to determine (i) the effect of changing the number of adjustment controls from three to two, (ii) the effect of changing the initial adjustment from overall output to high-frequency output, (iii) individual repeatability, (iv) the effect on phoneme recognition of increasing and decreasing overall output relative to the starting and adjusted conditions, and (v) listener reactions to, and opinions of, the self-adjustment procedure.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Design:<\/jats:title>\n                    <jats:p>Twenty-two adults with hearing loss, 10 of whom were hearing aid users, adjusted level and spectrum of connected speech to preference, using three configurations of number and order of adjustment parameters. The three adjustments were replicated to give a total of six. Presentation was monaural, in quiet, using the ear with the better threshold at 2\u2009kHz. The starting condition was a generic prescription for a typical mild-to-moderate hearing loss. Real ear output spectra were measured for the 6 self-adjustments, the generic starting condition, and the individual NAL-NL2 prescriptions for speech at 65 dB SPL. Monaural phoneme recognition in monosyllables was assessed, in quiet, at levels of \u221214, \u22127, 0 and +7 dB relative to both the starting and the self-adjusted conditions. Participants completed a questionnaire and their comments on each question were transcribed.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>Changing the number of listener controls from 3 to 2 reduced mean adjustment time by around 50% but had negligible effect on group-mean output response. Starting adjustment with high-frequency output rather than overall output resulted in a 2 to 3 dB reduction of group-mean self-adjusted output below 1\u2009kHz. Individual self-adjustments were within \u00b15 dB of NAL-NL2 prescription (for a 65 dB SPL speech input) for two-thirds of the participants in the high frequencies and for just over half in the low frequencies. In six self-adjustments, individuals self-adjusted, on average, to within \u00b14 dB of their own mean in both high and low frequencies. There was no evidence that these findings differed for hearing aid users and nonusers. Changes of overall output by \u00b17 dB after self-adjustment did not significantly affect group mean phoneme recognition. Preference for number and order of self-adjustment differed among participants, as did opinions on self-fitting of hearing aids.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>These findings support the conclusion that, for many adults with hearing loss, an explore-and-select procedure for self-adjustment of amplification leads to output values that are repeatable within a few dB, are relatively immune to the number and order of adjustment parameters, and place the average listener well along the plateau of a phoneme recognition versus amplitude function.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/aud.0000000000001141","type":"journal-article","created":{"date-parts":[[2021,10,19]],"date-time":"2021-10-19T04:21:36Z","timestamp":1634617296000},"page":"808-821","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":9,"title":["Amplification Self-Adjustment: Controls and Repeatability"],"prefix":"10.1097","volume":"43","author":[{"given":"Arthur","family":"Boothroyd","sequence":"first","affiliation":[{"name":"Speech, Language, Hearing Science, San Diego State University, San Diego, California, USA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jennifer","family":"Retana","sequence":"additional","affiliation":[{"name":"Speech, Language, Hearing Science, San Diego State University, San Diego, California, USA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carol L.","family":"Mackersie","sequence":"additional","affiliation":[{"name":"Speech, Language, Hearing Science, San Diego State University, San Diego, California, USA."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2021,10,13]]},"reference":[{"key":"R1-20250526","doi-asserted-by":"crossref","first-page":"118","DOI":"10.3766\/jaaa.16107","article-title":"Survey of current practice in the fitting and fine-tuning of common signal-processing features in hearing aids for adults.","volume":"29","author":"Anderson","year":"2018","journal-title":"J Am Acad Audiol"},{"key":"R2-20250526","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1044\/1059-0889.0701.05","article-title":"Ad hoc committee on hearing aid selection fitting: Guidelines for hearing aid fitting for adults.","volume":"7","year":"1998","journal-title":"Am J Audiol"},{"key":"R3-20250526","doi-asserted-by":"crossref","first-page":"479","DOI":"10.1097\/AUD.0b013e318174f067","article-title":"The performance\/intensity function: An underused resource.","volume":"29","author":"Boothroyd","year":"2008","journal-title":"Ear Hear"},{"issue":"3S","key":"R4-20250526","doi-asserted-by":"crossref","first-page":"430","DOI":"10.1044\/2017_AJA-16-0125","article-title":"A \u201cGoldilocks\u201d approach to hearing-aid self-fitting: User interactions.","volume":"26","author":"Boothroyd","year":"2017","journal-title":"Am J Audiol"},{"key":"R5-20250526","doi-asserted-by":"crossref","first-page":"306","DOI":"10.1097\/00003446-198812000-00006","article-title":"Voice fundamental frequency as an auditory supplement to the speechreading of sentences.","volume":"9","author":"Boothroyd","year":"1988","journal-title":"Ear Hear"},{"key":"R6-20250526","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1097\/00003446-198608000-00007","article-title":"The National Acoustic Laboratories\u2019 (NAL) new procedure for selecting the gain and frequency response of a hearing aid.","volume":"7","author":"Byrne","year":"1986","journal-title":"Ear Hear"},{"key":"R7-20250526","doi-asserted-by":"crossref","first-page":"672","DOI":"10.3766\/jaaa.19.9.3","article-title":"Prevalence of hearing impairment by gender and audiometric configuration: Results from the National Health and Nutrition Examination Survey (1999-2004) and the Keokuk County Rural Health Study (1994-1998).","volume":"19","author":"Ciletti","year":"2008","journal-title":"J Am Acad Audiol"},{"key":"R8-20250526","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1177\/1084713811424886","article-title":"Perception of a self-fitting hearing aid among urban-dwelling hearing-impaired adults in a developed country.","volume":"15","author":"Convery","year":"2011","journal-title":"Trends Amplif"},{"key":"R9-20250526","doi-asserted-by":"crossref","first-page":"794","DOI":"10.1097\/AUD.0000000000000663","article-title":"Factors associated with successful setup of a self-fitting hearing aid and the need for personalized support.","volume":"40","author":"Convery","year":"2019","journal-title":"Ear Hear"},{"key":"R10-20250526","doi-asserted-by":"crossref","first-page":"109","DOI":"10.3766\/jaaa.15076","article-title":"Evaluation of the self-fitting process with a commercially available hearing aid.","volume":"28","author":"Convery","year":"2017","journal-title":"J Am Acad Audiol"},{"key":"R13-20250526","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1177\/1084713812439798","article-title":"Cost-effective hearing rehabilitation: A role for self-fitting hearing aids?","volume":"15","author":"Dillon","year":"2011","journal-title":"Trends Amplif"},{"key":"R14-20250526","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1097\/AUD.0b013e3181cbc783","article-title":"Guest editorial: Accessible and affordable hearing health care for adults with mild to moderate hearing loss.","volume":"31","author":"Donahue","year":"2010","journal-title":"Ear Hear"},{"key":"R15-20250526","doi-asserted-by":"crossref","first-page":"214","DOI":"10.1097\/AUD.0b013e31816453a6","article-title":"Client-based adjustments of hearing aid gain: The effect of different control configurations.","volume":"29","author":"Dreschler","year":"2008","journal-title":"Ear Hear"},{"key":"R17-20250526","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1044\/2017_AJA-16-0111","article-title":"The effects of service-delivery model and purchase price on hearing-aid outcomes in older adults: A randomized double-blind placebo-controlled clinical trial.","volume":"26","author":"Humes","year":"2017","journal-title":"Am J Audiol"},{"key":"R18-20250526","doi-asserted-by":"crossref","first-page":"2331216516643284","DOI":"10.1177\/2331216516643284","article-title":"Self-fitting hearing aids: Status quo and future predictions.","volume":"20","author":"Keidser","year":"2016","journal-title":"Trends Hear"},{"key":"R19-20250526","doi-asserted-by":"crossref","first-page":"1668","DOI":"10.1121\/1.2951500","article-title":"The effect of the base line response on self-adjustments of hearing aid gain.","volume":"124","author":"Keidser","year":"2008","journal-title":"J Acoust Soc Am"},{"key":"R20-20250526","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1177\/1084713812468511","article-title":"NAL-NL2 empirical adjustments.","volume":"16","author":"Keidser","year":"2012","journal-title":"Trends Amplif"},{"key":"R21-20250526","doi-asserted-by":"crossref","first-page":"263","DOI":"10.3109\/03005369509076741","article-title":"Effect of initial setting on convergence to optimal hearing aid setting using a simplex method.","volume":"29","author":"Kuk","year":"1995","journal-title":"Br J Audiol"},{"key":"R22-20250526","doi-asserted-by":"crossref","first-page":"2331216520930545","DOI":"10.1177\/2331216520930545","article-title":"Hearing aid self-adjustment: effects of formal speech-perception test and noise.","volume":"24","author":"Mackersie","year":"2020","journal-title":"Trends Hear"},{"key":"R23-20250526","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1097\/AUD.0000000000000617","article-title":"A \u201cGoldilocks\u201d approach to hearing aid self-fitting: Ear-canal output and speech intelligibility index.","volume":"40","author":"Mackersie","year":"2019","journal-title":"Ear Hear"},{"key":"R24-20250526","doi-asserted-by":"crossref","first-page":"695","DOI":"10.1111\/j.1532-5415.2005.53221.x","article-title":"The Montreal Cognitive Assessment, MoCA: A brief screening tool for mild cognitive impairment.","volume":"53","author":"Nasreddine","year":"2005","journal-title":"J Am Geriatr Soc"},{"key":"R25-20250526","doi-asserted-by":"crossref","first-page":"2331216518798264","DOI":"10.1177\/2331216518798264","article-title":"Self-adjusted amplification parameters produce large between-subject variability and preserve speech intelligibility.","volume":"22","author":"Nelson","year":"2018","journal-title":"Trends Hear"},{"key":"R26-20250526","doi-asserted-by":"crossref","first-page":"1967","DOI":"10.1121\/1.395641","article-title":"An evaluation of three adaptive hearing aid selection strategies.","volume":"82","author":"Neuman","year":"1987","journal-title":"J Acoust Soc Am"},{"key":"R27-20250526","doi-asserted-by":"crossref","first-page":"2331216519837124","DOI":"10.1177\/2331216519837124","article-title":"Listener factors explain little variability in self-adjusted hearing aid gain.","volume":"23","author":"Perry","year":"2019","journal-title":"Trends Hear"},{"key":"R28-20250526","doi-asserted-by":"crossref","first-page":"714","DOI":"10.1044\/jshr.3803.714","article-title":"Quantifying the relation between speech quality and speech intelligibility.","volume":"38","author":"Preminger","year":"1995","journal-title":"J Speech Lang Hear Res"},{"key":"R29-20250526","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1097\/00003446-200006000-00001","article-title":"An examination of the practicality of the simplex procedure.","volume":"21","author":"Preminger","year":"2000","journal-title":"Ear Hear"},{"key":"R30-20250526","first-page":"94","article-title":"Prescriptive hearing aid fitting by parameter adjustment and selection.","volume":"3","author":"Punch","year":"1992","journal-title":"J Am Acad Audiol"},{"key":"R31-20250526","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1097\/00003446-199402000-00006","article-title":"Aided listener preferences in laboratory versus real-world environments.","volume":"15","author":"Punch","year":"1994","journal-title":"Ear Hear"},{"key":"R32-20250526","doi-asserted-by":"crossref","first-page":"2331216519847413","DOI":"10.1177\/2331216519847413","article-title":"Perceptual effects of adjusting hearing-aid gain by means of a machine-learning approach based on individual user preference.","volume":"23","author":"S\u00f8gaard Jensen","year":"2019","journal-title":"Trends Hear"},{"key":"R33-20250526","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1044\/2020_AJA-20-00085","article-title":"Toward a new evidence-based fitting paradigm for over-the-counter hearing aids.","volume":"30","author":"Urbanski","year":"2020","journal-title":"Am J Audiol"},{"key":"R34-20250526","first-page":"32","article-title":"Guidelines for the audiologic management of adult hearing impairment.","volume":"18","author":"Valente","year":"2007","journal-title":"Audiol Today"}],"container-title":["Ear &amp; Hearing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/AUD.0000000000001141","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,26]],"date-time":"2025-05-26T17:14:32Z","timestamp":1748279672000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/AUD.0000000000001141"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,10,13]]},"references-count":31,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.1097\/aud.0000000000001141","relation":{},"ISSN":["1538-4667"],"issn-type":[{"value":"1538-4667","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,10,13]]}}}