{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,12]],"date-time":"2026-11-12T10:50:22Z","timestamp":1794480622790,"version":"4.9.1"},"reference-count":62,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","license":[{"start":{"date-parts":[[2025,2,26]],"date-time":"2025-02-26T00:00:00Z","timestamp":1740528000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,9]]},"abstract":"<jats:sec>\n                    <jats:title>Objectives:<\/jats:title>\n                    <jats:p>Cochlear implant (CI) candidates increasingly exhibit some degree of residual hearing, which should be preserved despite the implantation. Today, cochlear health is monitored during CI surgery by tracking the cochlear microphonic (CM) amplitude from intracochlear electrocochleography (ECochG) measurements. However, recent studies indicate that the insertion depth of the measuring electrode must be considered to accurately interpret these signals. The acoustic path from the cochlear base to the apex induces excitation delays in deeper regions, which should be reflected in the CM measurements. In this study, we analyzed the potential of cochlear microphonic latency (CML) as an objective method for continuously tracking CI electrode position during cochlear implantation. In addition, we examined whether CML can be associated with residual hearing.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Design:<\/jats:title>\n                    <jats:p>We recorded intraoperative pure-tone ECochG at maximum stimulation levels from 30 CI patients to derive CML. During CI electrode insertion, ECochG was continuously recorded at the 2 stimulation frequencies of 0.5 and 0.75\u2009kHz. After complete insertion, ECochG was measured on all evenly numbered electrodes at frequencies of 0.25, 0.5, 0.75, and 1\u2009kHz. The electrode locations (i.e., linear insertion depth) were identified by postoperative computed tomography (CT) scans. The location of the measuring electrode during the insertion period was then calculated backward, assuming a constant insertion speed. Finally, we used a linear regression model to relate CML to linear insertion depth. In addition, we evaluated the relationship between CML and preoperative residual hearing.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      CML is significantly correlated to the linear insertion depth (\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      &lt; 0.001) during and after electrode insertion (with restrictions on 0.25\u2009kHz stimulus, presumably since the characteristic 0.25\u2009kHz region is not within reach of the used CI electrode arrays). Despite high inter-individual variability, our results align with documented delays in the basilar membrane observed in other studies. However, we could not identify a significant association between CML and residual hearing.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Our study demonstrates that objectively extracted CML encodes the intracochlear electrode location in CI patients but is not directly linked to residual hearing. Consequently, CML has the potential to enhance intraoperative ECochG analysis by providing real-time tracking of electrode position. To better understand the inter-individual variations in CML, future studies with larger patient cohorts are needed.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/aud.0000000000001652","type":"journal-article","created":{"date-parts":[[2025,2,26]],"date-time":"2025-02-26T00:00:23Z","timestamp":1740528023000},"page":"1130-1140","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":4,"title":["Electrocochleography Latency: Correlation With Electrode Position During Cochlear Implantation"],"prefix":"10.1097","volume":"46","author":[{"given":"Raphael R.","family":"Andonie","sequence":"first","affiliation":[{"name":"ARTORG Center for Biomedical Engineering Research, Bern University Hospital, University of Bern, Bern, Switzerland"},{"name":"Department of Otorhinolaryngology, Head & Neck Surgery, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wilhelm","family":"Wimmer","sequence":"additional","affiliation":[{"name":"Department of Otorhinolaryngology, Head & Neck Surgery, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland"},{"name":"Department of Otorhinolaryngology, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Reto A.","family":"Wildhaber","sequence":"additional","affiliation":[{"name":"School of Life Sciences, Institute for Medical Engineering and Medical Informatics, University of Applied Sciences and Arts Northwestern Switzerland, Muttenz, Switzerland"},{"name":"Deptartment of Information Technology and Electrical Engineering, Signal and Information Processing Laboratory (ISI), ETH Zurich, Zurich, Switzerland."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Georgios","family":"Mantokoudis","sequence":"additional","affiliation":[{"name":"Department of Otorhinolaryngology, Head & Neck Surgery, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marco","family":"Caversaccio","sequence":"additional","affiliation":[{"name":"ARTORG Center for Biomedical Engineering Research, Bern University Hospital, University of Bern, Bern, Switzerland"},{"name":"Department of Otorhinolaryngology, Head & Neck Surgery, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefan","family":"Weder","sequence":"additional","affiliation":[{"name":"Department of Otorhinolaryngology, Head & Neck Surgery, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,2,26]]},"reference":[{"key":"R1-20260303","doi-asserted-by":"crossref","first-page":"409","DOI":"10.1097\/AUD.0000000000000400","article-title":"Using neural response telemetry to monitor physiological responses to acoustic stimulation in hybrid cochlear implant users.","volume":"38","author":"Abbas","year":"2017","journal-title":"Ear Hear"},{"key":"R2-20260303","doi-asserted-by":"crossref","first-page":"904","DOI":"10.1097\/MAO.0000000000000620","article-title":"Method to estimate the complete and two-turn cochlear duct length.","volume":"36","author":"Alexiades","year":"2015","journal-title":"Otol Neurotol"},{"key":"R3-20260303","first-page":"1455613221134860","article-title":"Cochlear implantation: The variation in cochlear height.","volume":"0","author":"Alshalan","year":"2022","journal-title":"Ear Nose Throat J"},{"key":"R4-20260303","first-page":"16","article-title":"Electrocochleography in cochlear implant recipients: Correlating maximum response with residual hearing.","volume":"1","author":"Andonie","year":"2024","journal-title":"Ear Hear"},{"key":"R5-20260303","doi-asserted-by":"crossref","first-page":"3137","DOI":"10.1109\/TBME.2023.3276993","article-title":"Real-time feature extraction from electrocochleography with impedance measurements during cochlear implantation using linear state-space models.","volume":"70","author":"Andonie","year":"2023","journal-title":"IEEE Trans Biomed Eng"},{"key":"R7-20260303","doi-asserted-by":"crossref","first-page":"588","DOI":"10.1121\/1.1918543","article-title":"Hearing theories and complex sounds.","volume":"35","author":"B\u00e9k\u00e9sy","year":"2005","journal-title":"J Acoust Soc Am"},{"key":"R64-20260303","first-page":"66","article-title":"\u00dcber die Resonanzkurve und die Abklingzeit der verschiedenen Stellen der Schneckentrennwand.","volume":"8","author":"Bekesy","year":"1943","journal-title":"Akust. Z"},{"key":"R8-20260303","doi-asserted-by":"crossref","first-page":"141","DOI":"10.3389\/fnins.2017.00141","article-title":"Characterizing electrocochleography in cochlear implant recipients with residual low-frequency hearing.","volume":"11","author":"Bester","year":"2017","journal-title":"Front Neurosci"},{"key":"R9-20260303","doi-asserted-by":"crossref","first-page":"108353","DOI":"10.1016\/j.heares.2021.108353","article-title":"Electrocochleography triggered intervention successfully preserves residual hearing during cochlear implantation: Results of a randomised clinical trial.","volume":"426","author":"Bester","year":"2022","journal-title":"Hear Res"},{"key":"R10-20260303","doi-asserted-by":"crossref","first-page":"710","DOI":"10.1097\/AUD.0000000000001319","article-title":"Electrocochleographic patterns predicting increased impedances and hearing loss after cochlear implantation.","volume":"44","author":"Bester","year":"2023","journal-title":"Ear Hear"},{"key":"R11-20260303","doi-asserted-by":"crossref","first-page":"108094","DOI":"10.1016\/j.heares.2020.108094","article-title":"Cochlear microphonic latency predicts outer hair cell function in animal models and clinical populations.","volume":"398","author":"Bester","year":"2020","journal-title":"Hear Res"},{"key":"R12-20260303","doi-asserted-by":"crossref","first-page":"1451","DOI":"10.1097\/MAO.0000000000000451","article-title":"Intracochlear electrocochleography during cochlear implantation.","volume":"35","author":"Calloway","year":"2014","journal-title":"Otol Neurotol"},{"key":"R13-20260303","doi-asserted-by":"crossref","first-page":"180","DOI":"10.1159\/000478692","article-title":"Electrophysiological evidence of the basilar-membrane travelling wave and frequency place coding of sound in cochlear implant recipients.","volume":"22","author":"Campbell","year":"2017","journal-title":"Audiol Neurootol"},{"key":"R14-20260303","doi-asserted-by":"crossref","first-page":"1531","DOI":"10.1056\/NEJMra1904407","article-title":"Cochlear implantation in adults.","volume":"382","author":"Carlson","year":"2020","journal-title":"N Engl J Med"},{"key":"R15-20260303","doi-asserted-by":"crossref","first-page":"1370","DOI":"10.1097\/MAO.0b013e31822f09f2","article-title":"Detection of intracochlear damage with cochlear implantation in a gerbil model of hearing loss.","volume":"32","author":"Choudhury","year":"2011","journal-title":"Otol Neurotol"},{"key":"R16-20260303","doi-asserted-by":"crossref","first-page":"339","DOI":"10.1159\/000438742","article-title":"Extra- and intracochlear electrocochleography in cochlear implant recipients.","volume":"20","author":"Dalbert","year":"2015","journal-title":"Audiol Neurootol"},{"issue":"Suppl 2","key":"R17-20260303","doi-asserted-by":"crossref","first-page":"1140","DOI":"10.1121\/1.1912475","article-title":"Travel time in the cochlea and its determination from cochlear-microphonic data.","volume":"49","author":"Dallos","year":"1971","journal-title":"J Acoust Soc Am"},{"key":"R18-20260303","doi-asserted-by":"crossref","first-page":"510","DOI":"10.1121\/1.381086","article-title":"Production of cochlear potentials by inner and outer hair cells.","volume":"60","author":"Dallos","year":"1976","journal-title":"J Acoust Soc Am"},{"key":"R19-20260303","doi-asserted-by":"crossref","first-page":"463","DOI":"10.1121\/1.382345","article-title":"Narrow-band AP latencies in normal and recruiting human ears.","volume":"65","author":"Eggermont","year":"1979","journal-title":"J Acoust Soc Am"},{"key":"R20-20260303","doi-asserted-by":"crossref","first-page":"580","DOI":"10.1152\/jn.00446.2013","article-title":"Distinguishing hair cell from neural potentials recorded at the round window.","volume":"111","author":"Forgues","year":"2014","journal-title":"J Neurophysiol"},{"key":"R21-20260303","doi-asserted-by":"crossref","first-page":"108487","DOI":"10.1016\/j.heares.2022.108487","article-title":"Review: Clinical perspective on hearing preservation in cochlear implantation, the University of Iowa experience.","volume":"426","author":"Gantz","year":"2022","journal-title":"Hear Res"},{"key":"R22-20260303","doi-asserted-by":"crossref","first-page":"833","DOI":"10.1097\/AUD.0000000000000659","article-title":"Intracochlear electrocochleography: Response patterns during cochlear implantation and hearing preservation.","volume":"40","author":"Giardina","year":"2019","journal-title":"Ear Hear"},{"key":"R23-20260303","doi-asserted-by":"crossref","first-page":"1146","DOI":"10.1097\/AUD.0000000000000571","article-title":"Response changes during insertion of a cochlear implant using extracochlear electrocochleography.","volume":"39","author":"Giardina","year":"2018","journal-title":"Ear Hear"},{"key":"R24-20260303","doi-asserted-by":"crossref","first-page":"413","DOI":"10.1097\/AUD.0b013e31827e8163","article-title":"Cochlear implantation with hearing preservation yields significant benefit for speech recognition in complex listening environments.","volume":"34","author":"Gifford","year":"2013","journal-title":"Ear Hear"},{"key":"R25-20260303","doi-asserted-by":"crossref","first-page":"2592","DOI":"10.1121\/1.399052","article-title":"A cochlear frequency-position function for several species\u201329 years later.","volume":"87","author":"Greenwood","year":"1990","journal-title":"J Acoust Soc Am"},{"key":"R26-20260303","first-page":"74","article-title":"Extended applications for cochlear implantation.","volume":"81","author":"Hempel","year":"2018","journal-title":"Adv Otorhinolaryngol"},{"key":"R27-20260303","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1055\/s-2007-998358","article-title":"[Correlation of the latency shift and brain stem potentials in basocochlear hearing loss and the time course of the click stimulus-induced evoked wave in the cochlea].","volume":"68","author":"Janssen","year":"1989","journal-title":"Laryngorhinootologie"},{"key":"R28-20260303","doi-asserted-by":"crossref","first-page":"e654","DOI":"10.1097\/MAO.0000000000001906","article-title":"Intra-cochlear electrocochleography during cochlear implant electrode insertion is predictive of final scalar location.","volume":"39","author":"Koka","year":"2018","journal-title":"Otol Neurotol"},{"key":"R29-20260303","doi-asserted-by":"crossref","first-page":"e161","DOI":"10.1097\/AUD.0000000000000385","article-title":"Electrocochleography in cochlear implant recipients with residual hearing: comparison with audiometric thresholds.","volume":"38","author":"Koka","year":"2017","journal-title":"Ear Hear"},{"key":"R30-20260303","doi-asserted-by":"crossref","first-page":"e72","DOI":"10.1097\/MAO.0000000000003403","article-title":"Relationship between intraoperative electrocochleography and hearing preservation.","volume":"43","author":"Lenarz","year":"2022","journal-title":"Otol Neurotol"},{"key":"R31-20260303","doi-asserted-by":"crossref","first-page":"1222","DOI":"10.1097\/MAO.0000000000002773","article-title":"Intraoperative observational real-time electrocochleography as a predictor of hearing loss after cochlear implantation: 3 and 12 month outcomes.","volume":"41","author":"O\u2019Leary","year":"2020","journal-title":"Otol Neurotol"},{"key":"R32-20260303","doi-asserted-by":"crossref","first-page":"358","DOI":"10.1097\/AUD.0000000000001288","article-title":"Monitoring cochlear health with intracochlear electrocochleography during cochlear implantation: Findings from an International Clinical Investigation.","volume":"44","author":"O\u2019Leary","year":"2022","journal-title":"Ear Hear"},{"key":"R33-20260303","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/j.heares.2012.04.017","article-title":"Von B\u00e9k\u00e9sy and cochlear mechanics.","volume":"293","author":"Olson","year":"2012","journal-title":"Hear Res"},{"key":"R34-20260303","doi-asserted-by":"crossref","first-page":"400","DOI":"10.3390\/brainsci12030400","article-title":"In vivo basilar membrane time delays in humans.","volume":"12","author":"Polak","year":"2022","journal-title":"Brain Sci"},{"key":"R35-20260303","doi-asserted-by":"crossref","first-page":"1011","DOI":"10.1097\/MAO.0000000000002304","article-title":"Clinical applicability of a preoperative angular insertion depth prediction method for cochlear implantation.","volume":"40","author":"Rathgeb","year":"2019","journal-title":"Otol Neurotol"},{"key":"R36-20260303","doi-asserted-by":"crossref","first-page":"1305","DOI":"10.1152\/physrev.2001.81.3.1305","article-title":"Mechanics of the mammalian cochlea.","volume":"81","author":"Robles","year":"2001","journal-title":"Physiol Rev"},{"key":"R37-20260303","article-title":"WebPlotDigitizer.","author":"Rohatgi","year":"2024"},{"key":"R38-20260303","doi-asserted-by":"crossref","first-page":"131","DOI":"10.3109\/00206099409071874","article-title":"Cochlear delays and traveling waves: comments on \u2018Experimental look at cochlear mechanics\u2019.","volume":"33","author":"Ruggero","year":"1994","journal-title":"Audiology"},{"key":"R39-20260303","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1152\/jn.1987.58.2.379","article-title":"Timing of spike initiation in cochlear afferents: Dependence on site of innervation.","volume":"58","author":"Ruggero","year":"1987","journal-title":"J Neurophysiol"},{"key":"R40-20260303","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1007\/s10162-007-0081-z","article-title":"Similarity of traveling-wave delays in the hearing organs of humans and other tetrapods.","volume":"8","author":"Ruggero","year":"2007","journal-title":"J Assoc Res Otolaryngol"},{"key":"R63-20260303","doi-asserted-by":"crossref","first-page":"2660","DOI":"10.1073\/pnas.94.6.2660","article-title":"The location of the cochlear amplifier: spatial representation of a single tone on the guinea pig basilar membrane.","volume":"94","author":"Russell","year":"1997","journal-title":"Proceedings of the National Academy of Sciences"},{"key":"R41-20260303","doi-asserted-by":"crossref","first-page":"330","DOI":"10.3390\/brainsci13020330","article-title":"Multi-frequency electrocochleography and electrode scan to identify electrode insertion trauma during cochlear implantation.","volume":"13","author":"Saoji","year":"2023","journal-title":"Brain Sci"},{"key":"R42-20260303","doi-asserted-by":"crossref","first-page":"1503","DOI":"10.1121\/1.1354987","article-title":"DPOAE group delays versus electrophysiological measures of cochlear delay in normal human ears.","volume":"109","author":"Schoonhoven","year":"2001","journal-title":"J Acoust Soc Am"},{"key":"R43-20260303","doi-asserted-by":"crossref","first-page":"1379","DOI":"10.1097\/AUD.0000000000001379","article-title":"Postoperative impedance-based estimation of cochlear implant electrode insertion depth.","volume":"44","author":"Schraivogel","year":"2023","journal-title":"Ear Hear"},{"key":"R44-20260303","doi-asserted-by":"crossref","first-page":"1183116","DOI":"10.3389\/fneur.2023.1183116","article-title":"Cochlear implant electrode impedance subcomponents as biomarker for residual hearing.","volume":"14","author":"Schraivogel","year":"2023","journal-title":"Front Neurol"},{"key":"R45-20260303","doi-asserted-by":"crossref","first-page":"4655","DOI":"10.1007\/s00405-021-07204-7","article-title":"Increasing the reliability of real-time electrocochleography during cochlear implantation: A standardized guideline.","volume":"279","author":"Schuerch","year":"2022","journal-title":"Eur Arch Otorhinolaryngol"},{"key":"R46-20260303","first-page":"e63153","article-title":"Performing intracochlear electrocochleography during cochlear implantation.","volume":"181","author":"Schuerch","year":"2022","journal-title":"J Vis Exp"},{"key":"R47-20260303","doi-asserted-by":"crossref","first-page":"943816","DOI":"10.3389\/fneur.2022.943816","article-title":"Objectification of intracochlear electrocochleography using machine learning.","volume":"13","author":"Schuerch","year":"2022","journal-title":"Front Neurol"},{"key":"R48-20260303","doi-asserted-by":"crossref","first-page":"1181539","DOI":"10.3389\/fneur.2023.1181539","article-title":"Objective evaluation of intracochlear electrocochleography: Repeatability, thresholds, and tonotopic patterns.","volume":"14","author":"Schuerch","year":"2023","journal-title":"Front Neurol"},{"key":"R49-20260303","doi-asserted-by":"crossref","first-page":"2473974","DOI":"10.1177\/2473974X18800238","article-title":"A novel method for clinical cochlear duct length estimation toward patient-specific cochlear implant selection.","volume":"2","author":"Schurzig","year":"2018","journal-title":"OTO Open"},{"key":"R51-20260303","doi-asserted-by":"crossref","first-page":"145","DOI":"10.3766\/jaaa.26.2.5","article-title":"Preserved acoustic hearing in cochlear implantation improves speech perception.","volume":"26","author":"Sheffield","year":"2015","journal-title":"J Am Acad Audiol"},{"key":"R52-20260303","doi-asserted-by":"crossref","first-page":"23312165231220997","DOI":"10.1177\/23312165231220997","article-title":"Classification of acoustic hearing preservation after cochlear implantation using electrocochleography.","volume":"27","author":"Sijgers","year":"2023","journal-title":"Trends Hear"},{"key":"R65-20260303","doi-asserted-by":"crossref","first-page":"e33","DOI":"10.1097\/01.aud.0000444781.15858.f1","article-title":"Cochlear implantation with the nucleus slim straight electrode in subjects with residual low-frequency hearing.","volume":"35","author":"Skarzynski","year":"2014","journal-title":"Ear hear"},{"key":"R53-20260303","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1159\/000334948","article-title":"Validity of cochlear microphonics at high sound pressure levels as an important clinical aspect.","volume":"74","author":"Teschner","year":"2012","journal-title":"ORL J Otorhinolaryngol Relat Spec"},{"key":"R54-20260303","doi-asserted-by":"crossref","first-page":"722","DOI":"10.1097\/MAO.0b013e3181d279e0","article-title":"Consensus panel on a cochlear coordinate system applicable in histologic, physiologic, and radiologic studies of the human cochlea.","volume":"31","author":"Verbist","year":"2010","journal-title":"Otol Neurotol"},{"key":"R55-20260303","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1038\/s41592-019-0686-2","article-title":"SciPy 1.0: Fundamental algorithms for scientific computing in python.","volume":"17","author":"Virtanen","year":"2020","journal-title":"Nat Methods"},{"key":"R56-20260303","doi-asserted-by":"crossref","first-page":"1560","DOI":"10.1097\/AUD.0000000000000871","article-title":"Toward a better understanding of electrocochleography.","volume":"41","author":"Weder","year":"2020","journal-title":"Ear Hear"},{"key":"R57-20260303","doi-asserted-by":"crossref","first-page":"e1030","DOI":"10.1097\/MAO.0000000000003177","article-title":"Real time monitoring during cochlear implantation: Increasing the accuracy of predicting residual hearing outcomes.","volume":"42","author":"Weder","year":"2021","journal-title":"Otol Neurotol"},{"key":"R58-20260303","doi-asserted-by":"crossref","first-page":"3768","DOI":"10.1109\/TSP.2018.2833804","article-title":"Windowed state-space filters for signal detection and separation.","volume":"66","author":"Wildhaber","year":"2018","journal-title":"IEEE Trans Signal Process"},{"key":"R59-20260303","doi-asserted-by":"crossref","first-page":"4603","DOI":"10.1007\/s00405-024-08639-4","article-title":"Metronome-guided cochlear implantation for slower and smoother insertions of lateral wall electrodes.","volume":"281","author":"Wimmer","year":"2024","journal-title":"Eur Arch Otorhinolaryngol"},{"key":"R61-20260303","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1097\/MAO.0000000000002996","article-title":"Clinical utility of intraoperative electrocochleography (ECochG) during cochlear implantation: A systematic review and quantitative analysis.","volume":"42","author":"Yin","year":"2021","journal-title":"Otol Neurotol"},{"key":"R62-20260303","doi-asserted-by":"crossref","first-page":"077201","DOI":"10.1121\/10.0012825","article-title":"Celebrating the one millionth cochlear implant.","volume":"2","author":"Zeng","year":"2022","journal-title":"JASA Express Lett"}],"container-title":["Ear &amp; Hearing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/AUD.0000000000001652","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,3]],"date-time":"2026-03-03T04:00:23Z","timestamp":1772510423000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/AUD.0000000000001652"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,2,26]]},"references-count":62,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/aud.0000000000001652","relation":{},"ISSN":["1538-4667"],"issn-type":[{"value":"1538-4667","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,2,26]]}}}