{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T11:43:06Z","timestamp":1792755786709,"version":"4.5.0"},"reference-count":52,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","license":[{"start":{"date-parts":[[2025,5,22]],"date-time":"2025-05-22T00:00:00Z","timestamp":1747872000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,9]]},"abstract":"<jats:sec>\n                    <jats:title>Objectives:<\/jats:title>\n                    <jats:p>Cochlear implant companies manufacture devices with different electrode array types. Some arrays have a straight geometry designed for minimal neuronal trauma, while others are precurved and designed to position the electrodes closer to the cochlear neurons. Due to their differing geometries, it is possible that the arrays are not only positioned differently inside the cochlea but also produce different patterns of the spread of current and of neural excitation. The panoramic electrically evoked compound action potential method (PECAP) provides detailed estimates of peripheral neural responsiveness and current spread for individual patients along the length of the cochlea. These estimates were assessed as a function of electrode position and array type, providing a normative dataset useful for identifying unusual patterns in individual patients.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Design:<\/jats:title>\n                    <jats:p>ECAPs were collected from cochlear implant users using the forward-masking artifact-reduction technique for every combination of masker and probe electrode at the most comfortable level. Data were available for 91 ears using Cochlear devices, and 53 ears using Advanced Bionics devices. The Cochlear users had straight arrays (Slim Straight, CI-22 series, n = 35), or 1 of 2 precurved arrays (Contour Advance, CI-12 series, n = 43, or Slim Modiolar, CI-32 series, n = 13). Computed tomography scans were also available for 41 of them, and electrode-modiolus distances were calculated. The Advanced Bionics users had 1 of 2 straight arrays (1J, n = 9 or SlimJ, n = 20), or precurved arrays (Helix, n = 4 or Mid-Scala, n = 20). The ECAPs were submitted to the PECAP algorithm to estimate current spread and neural responsiveness along the length of the electrode array for each user. A linear mixed-effects model was used to determine whether there were statistically significant differences between different array types and\/or for different electrodes, both for the PECAP estimates of current spread and neural responsiveness, as well as for the available electrode-modiolus distances. Correlations were also conducted between PECAP\u2019s estimate of current spread and the electrode-modiolus distances.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      For Cochlear users, significant effects of array type (\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      = 0.001) and of electrode (\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      &lt; 0.001) were found on the PECAP\u2019s current-spread estimate, as well as a significant interaction (\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      = 0.006). Slim Straight arrays had a wider overall current spread than both the precurved arrays (Contour Advance and Slim Modiolar). The interaction revealed the strongest effect at the apex. A significant correlation between PECAP\u2019s current-spread estimate and the electrode-modiolus distances was also found across subjects (\n                      <jats:italic toggle=\"yes\">r<\/jats:italic>\n                      = 0.516,\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      &lt; 0.001). No effect of array type was found on PECAP\u2019s estimate of current spread for the Advanced Bionics users (\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      = 0.979).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>These results suggest that for users of the Cochlear device, precurved electrode arrays show narrower current spread within the cochlea than those with lateral-wall electrode arrays, with the strongest effect present at the apex. No corresponding effects of array type were found in the Advanced Bionics device. This could have implications for device selection in clinical settings, although the authors underscore that this is a post-hoc analysis and does not demonstrate a causal link wherein device selection can be expected to give rise to specific neural excitation patterns.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/aud.0000000000001673","type":"journal-article","created":{"date-parts":[[2025,5,22]],"date-time":"2025-05-22T00:00:26Z","timestamp":1747872026000},"page":"1355-1368","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":10,"title":["Assessing Array-Type Differences in Cochlear Implant Users Using the Panoramic ECAP Method"],"prefix":"10.1097","volume":"46","author":[{"given":"Charlotte","family":"Garcia","sequence":"first","affiliation":[{"name":"Cambridge Hearing Group, Medical Research Council Cognition & Brain Sciences Unit, University of Cambridge, Cambridge, United Kingdom."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert P.","family":"Carlyon","sequence":"additional","affiliation":[{"name":"Cambridge Hearing Group, Medical Research Council Cognition & Brain Sciences Unit, University of Cambridge, Cambridge, United Kingdom."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,5,22]]},"reference":[{"key":"R1-20260303","doi-asserted-by":"crossref","first-page":"2983","DOI":"10.1121\/1.5079636","article-title":"Development and validation of a spectro-temporal processing test for cochlear-implant listeners.","volume":"144","author":"Archer-Boyd","year":"2018","journal-title":"J Acoust Soc Am"},{"key":"R2-20260303","doi-asserted-by":"crossref","first-page":"790","DOI":"10.1097\/MAO.0000000000004242","article-title":"Clinical applications for spread of excitation functions obtained via electrically evoked compound action potentials (eCAP).","volume":"45","author":"Berg","year":"2024","journal-title":"Otol Neurotol"},{"key":"R3-20260303","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1177\/1084713810375249","article-title":"Probing the electrode\u2013neuron interface with focused cochlear implant stimulation.","volume":"14","author":"Bierer","year":"2010","journal-title":"Trends Amplif"},{"key":"R4-20260303","doi-asserted-by":"crossref","first-page":"572","DOI":"10.1097\/AUD.0000000000000296","article-title":"A novel algorithm to derive spread of excitation based on deconvolution.","volume":"37","author":"Biesheuvel","year":"2016","journal-title":"Ear Hear"},{"key":"R5-20260303","doi-asserted-by":"crossref","first-page":"2565","DOI":"10.1121\/1.422777","article-title":"Forward masked excitation patterns in multielectrode electrical stimulation.","volume":"103","author":"Chatterjee","year":"1998","journal-title":"J Acoust Soc Am"},{"key":"R6-20260303","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1080\/00016489.2018.1533993","article-title":"Impact of cochlear tonotopy on electrically evoked compound action potentials (ECAPs).","volume":"139","author":"Christov","year":"2019","journal-title":"Acta Otolaryngol"},{"key":"R7-20260303","doi-asserted-by":"crossref","first-page":"559","DOI":"10.1080\/14992020500258743","article-title":"A psychophysical forward masking comparison of longitudinal spread of neural excitation in the ContourTM and straight Nucleus\u00ae electrode arrays: Comparaci\u00f3n psicof\u00edsica con enmascaramiento anter\u00f3grado de la propagaci\u00f3n longitudinal de la excitaci\u00f3n neural con hilos de electrodos Contour TMy Nucleus\u00ae recto.","volume":"44","author":"Cohen","year":"2005","journal-title":"Int J Audiol"},{"key":"R8-20260303","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1016\/S0378-5955(03)00096-0","article-title":"Spatial spread of neural excitation in cochlear implant recipients: Comparison of improved ECAP method and psychophysical forward masking.","volume":"179","author":"Cohen","year":"2003","journal-title":"Hear Res"},{"key":"R9-20260303","doi-asserted-by":"crossref","first-page":"160","DOI":"10.1016\/j.heares.2005.11.005","article-title":"Psychophysical measures in patients fitted with ContourTM and straight Nucleus electrode arrays.","volume":"212","author":"Cohen","year":"2006","journal-title":"Hear Res"},{"key":"R10-20260303","doi-asserted-by":"crossref","first-page":"1815","DOI":"10.1007\/s00405-020-06260-9","article-title":"Is the spread of excitation width correlated to the speech recognition in cochlear implant users?","volume":"278","author":"da Silva","year":"2021","journal-title":"Eur Arch Otorhinolaryngol"},{"key":"R11-20260303","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1097\/MAO.0000000000000896","article-title":"Relationship between electrode-to-modiolus distance and current levels for adults with cochlear implants.","volume":"37","author":"Davis","year":"2016","journal-title":"Otol Neurotol"},{"key":"R12-20260303","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1016\/j.heares.2017.10.005","article-title":"An overview of cochlear implant electrode array designs.","volume":"356","author":"Dhanasingh","year":"2017","journal-title":"Hear Res"},{"key":"R13-20260303","doi-asserted-by":"crossref","first-page":"1081","DOI":"10.3390\/mi13071081","article-title":"Recent advances in cochlear implant electrode array design parameters.","volume":"13","author":"Ertas","year":"2022","journal-title":"Micromachines"},{"key":"R14-20260303","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1097\/01.AUD.0000134552.22205.EE","article-title":"Recognition of speech presented at soft to loud levels by adult cochlear implant recipients of three cochlear implant systems.","volume":"25","author":"Firszt","year":"2004","journal-title":"Ear Hear"},{"key":"R15-20260303","doi-asserted-by":"crossref","first-page":"1150","DOI":"10.1121\/1.1381538","article-title":"Speech recognition in noise as a function of the number of spectral channels: Comparison of acoustic hearing and cochlear implants.","volume":"110","author":"Friesen","year":"2001","journal-title":"J Acoust Soc Am"},{"key":"R16-20260303","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1007\/s00405-019-05680-6","article-title":"Comparative study of two different perimodiolar and a straight cochlear implant electrode array: Surgical and audiological outcomes.","volume":"277","author":"Garaycochea","year":"2020","journal-title":"Eur Arch Otorhinolaryngol"},{"key":"R17-20260303","doi-asserted-by":"crossref","first-page":"627","DOI":"10.1097\/AUD.0000000000001305","article-title":"SpeedCAP: An efficient method for estimating neural activation patterns using electrically evoked compound action-potentials in cochlear implant users.","volume":"44","author":"Garcia","year":"2023","journal-title":"Ear Hear"},{"key":"R18-20260303","doi-asserted-by":"crossref","first-page":"567","DOI":"10.1007\/s10162-021-00795-2","article-title":"The panoramic ECAP method: Estimating patient-specific patterns of current spread and neural health in cochlear implant users.","volume":"22","author":"Garcia","year":"2021","journal-title":"J Assoc Res Otolaryngol"},{"key":"R20-20260303","doi-asserted-by":"crossref","first-page":"591","DOI":"10.1007\/s10162-024-00966-x","article-title":"Investigating the effect of blurring and focusing current in cochlear implant users with the panoramic ECAP method.","volume":"25","author":"Garcia","year":"2024","journal-title":"J Assoc Res Otolaryngol"},{"key":"R21-20260303","doi-asserted-by":"crossref","first-page":"7045","DOI":"10.3390\/jcm11237045","article-title":"Robot-assisted electrode insertion in cochlear implantation controlled by intraoperative electrocochleography\u2014a pilot study.","volume":"11","author":"Gaw\u0119cki","year":"2022","journal-title":"J Clin Med"},{"key":"R22-20260303","doi-asserted-by":"crossref","first-page":"Article 1","DOI":"10.1038\/s41598-021-89932-8","article-title":"The effect of increased channel interaction on speech perception with cochlear implants.","volume":"11","author":"Goehring","year":"2021","journal-title":"Sci Rep"},{"key":"R23-20260303","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1007\/s10162-020-00758-z","article-title":"Using spectral blurring to assess effects of channel interaction on speech-in-noise perception with cochlear implants.","volume":"21","author":"Goehring","year":"2020","journal-title":"J Assoc Res Otolaryngol"},{"key":"R24-20260303","doi-asserted-by":"crossref","first-page":"3159","DOI":"10.1121\/1.4900634","article-title":"Pitch ranking, electrode discrimination, and physiological spread of excitation using current steering in cochlear implants.","volume":"136","author":"Goehring","year":"2014","journal-title":"J Acoust Soc Am"},{"key":"R25-20260303","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1016\/j.heares.2010.05.005","article-title":"Modeling the electrode-neuron interface of cochlear implants: Effects of neural survival, electrode placement, and the partial tripolar configuration.","volume":"268","author":"Goldwyn","year":"2010","journal-title":"Hear Res"},{"key":"R26-20260303","doi-asserted-by":"crossref","first-page":"1415","DOI":"10.1097\/MAO.0000000000000412","article-title":"The new mid-scala electrode array: A radiologic and histologic study in human temporal bones.","volume":"35","author":"Hassepass","year":"2014","journal-title":"Otol Neurotol"},{"key":"R27-20260303","doi-asserted-by":"crossref","first-page":"1160","DOI":"10.1097\/MAO.0000000000002366","article-title":"Matched cohort comparison indicates superiority of precurved electrode arrays.","volume":"40","author":"Holder","year":"2019","journal-title":"Otol Neurotol"},{"key":"R29-20260303","doi-asserted-by":"crossref","first-page":"228","DOI":"10.1097\/MAO.0000000000000672","article-title":"Intraindividual comparison of psychophysical parameters between perimodiolar and lateral-type electrode arrays in patients with bilateral cochlear implants.","volume":"36","author":"Jeong","year":"2015","journal-title":"Otol Neurotol"},{"key":"R30-20260303","doi-asserted-by":"crossref","first-page":"695728","DOI":"10.3389\/fsurg.2021.695728","article-title":"Robot-assisted electrode array insertion becomes available in pediatric cochlear implant recipients: First report and an intra-individual study.","volume":"8","author":"Jia","year":"2021","journal-title":"Front Surg"},{"key":"R31-20260303","doi-asserted-by":"crossref","first-page":"1358","DOI":"10.1002\/lary.29224","article-title":"Scalar translocation comparison between lateral wall and perimodiolar cochlear implant arrays\u2014a meta-analysis.","volume":"131","author":"Jwair","year":"2021","journal-title":"Laryngoscope"},{"key":"R32-20260303","doi-asserted-by":"crossref","first-page":"108591","DOI":"10.1016\/j.heares.2022.108591","article-title":"Influence of the spread of electric field on neural excitation in cochlear implant users: Transimpedance and spread of excitation measurements.","volume":"424","author":"Kopsch","year":"2022","journal-title":"Hear Res"},{"key":"R33-20260303","doi-asserted-by":"crossref","first-page":"145","DOI":"10.7874\/jao.2019.00164","article-title":"Effect of cochlear implant electrode array design on electrophysiological and psychophysical measures: Lateral wall versus perimodiolar types.","volume":"23","author":"Lee","year":"2019","journal-title":"J Audiol Otol"},{"key":"R34-20260303","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1016\/j.zemedi.2020.05.004","article-title":"Electrode translocations in perimodiolar cochlear implant electrodes: Audiological and electrophysiological outcome.","volume":"31","author":"Liebscher","year":"2021","journal-title":"Z Med Phys"},{"key":"R35-20260303","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1007\/s10162-013-0437-5","article-title":"Examining the electro-neural interface of cochlear implant users using psychophysics, CT scans, and speech understanding.","volume":"15","author":"Long","year":"2014","journal-title":"J Assoc Res Otolaryngol"},{"key":"R36-20260303","doi-asserted-by":"crossref","first-page":"e934","DOI":"10.1097\/MAO.0000000000002790","article-title":"Comparison of perimodiolar electrodes: Imaging and electrophysiological outcomes.","volume":"41","author":"Mewes","year":"2020","journal-title":"Otol Neurotol"},{"key":"R37-20260303","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1016\/j.heares.2008.04.005","article-title":"The clinical application of potentials evoked from the peripheral auditory system.","volume":"242","author":"Miller","year":"2008","journal-title":"Hear Res"},{"key":"R39-20260303","doi-asserted-by":"crossref","first-page":"2881","DOI":"10.1121\/1.402925","article-title":"Pitch discrimination and phase sensitivity in young and elderly subjects and its relationship to frequency selectivity.","volume":"91","author":"Moore","year":"1992","journal-title":"J Acoust Soc Am"},{"key":"R40-20260303","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1159\/000095966","article-title":"Measuring the refractoriness of the electrically stimulated auditory nerve.","volume":"11","author":"Morsnowski","year":"2006","journal-title":"Audiol Neurootol"},{"key":"R41-20260303","doi-asserted-by":"crossref","first-page":"1987","DOI":"10.1121\/1.413317","article-title":"Electrode ranking of \u201cplace pitch\u201d and speech recognition in electrical hearing.","volume":"98","author":"Nelson","year":"1995","journal-title":"J Acoust Soc Am"},{"key":"R43-20260303","doi-asserted-by":"crossref","first-page":"1016","DOI":"10.1097\/MAO.0000000000001125","article-title":"Electrode location and angular insertion depth are predictors of audiologic outcomes in cochlear implantation.","volume":"37","author":"O\u2019Connell","year":"2016","journal-title":"Otol Neurotol"},{"key":"R45-20260303","doi-asserted-by":"crossref","first-page":"e634","DOI":"10.1097\/MAO.0000000000003547","article-title":"The relation of cochlear implant electrode array type and position on continued hearing preservation.","volume":"43","author":"Perkins","year":"2022","journal-title":"Otol Neurotol"},{"key":"R46-20260303","doi-asserted-by":"crossref","first-page":"1385","DOI":"10.1007\/s00405-018-4943-2","article-title":"Imaging evaluation of electrode placement and effect on electrode discrimination on different cochlear implant electrode arrays.","volume":"275","author":"Ramos de Miguel","year":"2018","journal-title":"Eur Arch Otorhinolaryngol"},{"key":"R47-20260303","doi-asserted-by":"crossref","first-page":"1931","DOI":"10.1007\/s11548-020-02243-7","article-title":"A simple tool to automate the insertion process in cochlear implant surgery.","volume":"15","author":"Rau","year":"2020","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"R48-20260303","doi-asserted-by":"crossref","first-page":"1149","DOI":"10.1097\/MAO.0000000000003703","article-title":"Speech recognition performance differences between precurved and straight electrode arrays from a single manufacturer.","volume":"43","author":"Sharma","year":"2022","journal-title":"Otol Neurotol"},{"key":"R49-20260303","doi-asserted-by":"crossref","first-page":"108537","DOI":"10.1016\/j.heares.2022.108537","article-title":"3D-localisation of cochlear implant electrode contacts in relation to anatomical structures from in vivo cone-beam computed tomography.","volume":"426","author":"Sismono","year":"2022","journal-title":"Hear Res"},{"key":"R51-20260303","doi-asserted-by":"crossref","first-page":"108235","DOI":"10.1016\/j.heares.2021.108235","article-title":"Intraoperative transimpedance and spread of excitation profile correlations with a lateral-wall cochlear implant electrode array.","volume":"405","author":"S\u00f6derqvist","year":"2021","journal-title":"Hear Res"},{"key":"R52-20260303","doi-asserted-by":"crossref","first-page":"660","DOI":"10.1016\/j.ijporl.2015.02.008","article-title":"Effect of cochlear implant electrode array design on auditory nerve and behavioral response in children.","volume":"79","author":"Telmesani","year":"2015","journal-title":"Int J Pediatr Otorhinolaryngol"},{"key":"R53-20260303","doi-asserted-by":"crossref","first-page":"344","DOI":"10.1080\/14670100.2020.1788859","article-title":"Effect of age, electrode array, and time on cochlear implant impedances.","volume":"21","author":"Velandia","year":"2020","journal-title":"Cochlear Implants Int"},{"key":"R54-20260303","doi-asserted-by":"crossref","first-page":"e0287216","DOI":"10.1371\/journal.pone.0287216","article-title":"An analysis of the spread of electric field within the cochlea for different devices including custom-made electrodes for subtotal cochleoectomy.","volume":"18","author":"Wagner","year":"2023","journal-title":"PLoS One"},{"key":"R55-20260303","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1002\/lary.24728","article-title":"Impact of electrode design and surgical approach on scalar location and cochlear implant outcomes.","volume":"124","author":"Wanna","year":"2014","journal-title":"Laryngoscope"},{"key":"R56-20260303","doi-asserted-by":"crossref","first-page":"493","DOI":"10.1001\/archotol.1984.00800340005002","article-title":"Multichannel cochlear implants: Channel interactions and processor design.","volume":"110","author":"White","year":"1984","journal-title":"Arch Otolaryngol"},{"key":"R57-20260303","doi-asserted-by":"crossref","first-page":"228","DOI":"10.1159\/000229303","article-title":"Electrode interaction in cochlear implant recipients: Comparison of straight and contour electrode arrays.","volume":"71","author":"Xi","year":"2009","journal-title":"ORL J Otorhinolaryngol Relat Spec"},{"key":"R58-20260303","doi-asserted-by":"crossref","first-page":"e12467","DOI":"10.1016\/j.heliyon.2022.e12467","article-title":"Relationship between electrode position and temporal modulation sensitivity in cochlear implant users: Are close electrodes always better?","volume":"9","author":"Zhou","year":"2023","journal-title":"Heliyon"}],"container-title":["Ear &amp; Hearing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/AUD.0000000000001673","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,3]],"date-time":"2026-03-03T04:00:46Z","timestamp":1772510446000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/AUD.0000000000001673"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,22]]},"references-count":52,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/aud.0000000000001673","relation":{"has-preprint":[{"id-type":"doi","id":"10.31219\/osf.io\/wnf6d_v1","asserted-by":"object"}]},"ISSN":["1538-4667"],"issn-type":[{"value":"1538-4667","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,22]]}}}